Vahalla Scientific EN2500 Calibration 

Zenwizard Studios
Подписаться 2,9 тыс.
Просмотров 643
50% 1

First off let me say THANK YOU to all that have joined the lab and helped us get there we are today. Content is based of viewer questions and comments. And will continue to be. In this case this upgrade is so we can do some testing as requested by viewers specifically on 10Mhz references. So as always more is on the way.
Ways to support the channel:
Patreon - / zenwizard_studios
Paypal - Zenwizard@Zenwizardstudios.com
In this video we take a second pass at the 2500 EN this time we need to calibrate and Align the unit that was found to be out of specification in the last video. So after getting some resisters to use as loads in the lab and leveraging some Ohms law to help up bring the EN2500 up to specification.
** Repair exposes the Tech to mains electric and should only be done by trained personnel. Errors can be fatal. **

Наука

Опубликовано:

 

7 фев 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 7   
@jenniferwhitewolf3784
@jenniferwhitewolf3784 5 месяцев назад
With 14g wire, 1 foot out, 1 foot back, thats about 0.005 ohms. Not much, but at 10 amperes, that amounts to 50mV drop all by itself. This is quite the interesting project to calibrate.
@InssiAjaton
@InssiAjaton 3 месяца назад
Two things that i might do differently: First, I think I could get the fork connector cables folded over and just crimped that way. No soldering. Of course depends on, whether or not the forks actually take the folded cable end. The second thing is to make the highest current resistor as two in series and two of those in parallel. You would get 40 W resistor and avoid much of the thermal drift.
@ZenwizardStudios
@ZenwizardStudios 3 месяца назад
I have some true current shunts at 10 and 20 amps. Seems my fluke meter was still quite accurate. Needed a little adjustment but not to much on the 10A range.
@timgraham8975
@timgraham8975 5 месяцев назад
Wow that's Hot 650 Deg C aka 1202 Deg F.
@timgraham8975
@timgraham8975 5 месяцев назад
Why did you not just do the adjustments using the 7510 in DC current mode as your transfer standard, at least to the 100-mA range?
@ZenwizardStudios
@ZenwizardStudios 5 месяцев назад
This is mainly because of the accuracy range of the meters. The accuracy ranges tend to be a little looser on the current range than the voltage range. DC volt will be the highest accuracy. The service manual specifies a 3458A and wants 0.001% resisters for the adjustment process. Though I should have used the 10 amp range on the 7150 rather than the fluke. However the fluke served to be quite accurate when checked with an appropriate current shunt in the lab not the resister.
@wolfgangrichter6088
@wolfgangrichter6088 4 месяца назад
Why is everybody using the less better Davespeak instead of English ?
Далее
Tektronix Type 130 L C Meter Restoration
33:08
How to Measure Voltage with a Multimeter
0:47
Просмотров 505 тыс.
❤️My First Subscriber #shorts #thankyou
00:26
Просмотров 4,6 млн
ТОП 10 Худших игроков Евро-2024
30:22
Zen's Curve Tracer Buying Guide
39:49
Просмотров 1,5 тыс.
McIntosh MC-2105: Repair and Restoration
44:11
Просмотров 3,6 тыс.
Tektronix Type 130 Modernised Alignment
37:33
TM 503 Power Supply check in and repair VERY BAD PARTS!
32:37
How to Measure Current with a Multimeter
0:59
Просмотров 275 тыс.
Собери ПК и Получи 10,000₽
1:00
Просмотров 2,4 млн
ИГРОВОВЫЙ НОУТ ASUS ЗА 57 тысяч
25:33