Vaillant Ecotec Diverter valve change 

CP Utility Solutions
Подписаться 11 тыс.
Просмотров 30 тыс.
50% 1

DISCLAIMER:
This video is only intended for use by qualified Gas Safe Registered engineers. You must not attempt any work on your boiler if you are not qualified. You must always carry out 26.9 checks upon completion of works on a boiler.

Опубликовано:

 

18 сен 2021

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 70   
@macpatel7810
@macpatel7810 2 года назад
Another great video CP. Always good to see real life scenarios where it doesn't always go to plan.
@gmtplumbing8559
@gmtplumbing8559 2 года назад
Great vid been changing these occasionally for years never new about diverter mid position or purge mode ive made a note for next time, and keeping it real with the struggle you had 💪keep them coming✌
@petel5560
@petel5560 6 месяцев назад
Really helpful process tutorial. Best one i have found. Thank you CP Utility.
@cputilitysolutions
@cputilitysolutions 6 месяцев назад
Nice one 👍🏾
@Razz60
@Razz60 2 года назад
Love your videos bro thanks for taking your time to making these helpful vids big respect to you
@alanwild5890
@alanwild5890 10 месяцев назад
Thank for these instructions. Just replaced one using them 🏆
@cputilitysolutions
@cputilitysolutions 10 месяцев назад
Nice one 👍🏾
@sudhiradhikari19
@sudhiradhikari19 2 года назад
Came across your channel, very helpful, for new guy like me.
@ahmediqbal2828
@ahmediqbal2828 Год назад
Thank you for taking the time to make these videos!! Did my first diverter valve change today, myself and this video made it feel like a breeze so thank you bro. Your efforts are hugely appreciated!
@cputilitysolutions
@cputilitysolutions Год назад
Nice one glad it helped!
@GasTraining
@GasTraining Год назад
Are you a new engineer then? How you finding it? Currently doing portfolio, really interesting work.
@ahmediqbal2828
@ahmediqbal2828 Год назад
@@GasTraining I am bro yeah, I qualified around 9 months ago in gas . Really enjoying it. Been doing the plumbing for a few years and it all ties in perfectly. I've watched my boss do a few but never actually done much repair work myself but I'm slowly getting the hang of it. Hope your portfolio and exams go well!!
@user-li8gr8ur8l
@user-li8gr8ur8l 5 месяцев назад
Thanks again Chirag.❤ that was another excellent accurate video
@cputilitysolutions
@cputilitysolutions 5 месяцев назад
👍🏾
@gunsey876
@gunsey876 2 года назад
Nice work, I had to do one a few months back, the condense had leaked previously an rotted the bottom screw, made it a right treat 😡
@blipyoung2180
@blipyoung2180 2 года назад
Cheers mate for another great video.
@stevenjohnson6082
@stevenjohnson6082 2 года назад
for reference take copper pipe off first before removing screws also push turbine clip down its easier
@richardjones3112
@richardjones3112 Год назад
Great video,well explained,subbed.
@cputilitysolutions
@cputilitysolutions Год назад
Thank you 👍🏽
@Smokeblow
@Smokeblow 2 года назад
Beautiful😍… nice work too 😳
@geetee50
@geetee50 Год назад
Great job , I notice the insulation foam was shot. Normally on these the door foam goes brittle requiring a new door at £200+ due to seal failure so worth checking the burner seal with your analyser if you ever come across this condition of the foam insulation.
@Pb09120
@Pb09120 2 года назад
Top man brilliant work
@georgerobinson576
@georgerobinson576 2 года назад
good job , thanks for showing
@mcginn002
@mcginn002 2 года назад
Nice one mate 👍
@abualam4418
@abualam4418 2 года назад
Good job mate,
@raihankhan5638
@raihankhan5638 2 года назад
Very useful video
@dir5155
@dir5155 2 года назад
Greetings! The display from 242/3-5 can be put on Vaillant 242/3-3??
@user-ef2gw6df2f
@user-ef2gw6df2f Год назад
Some helpful tips 👍💪
@cputilitysolutions
@cputilitysolutions Год назад
Glad to hear it!
@cezars4155
@cezars4155 2 года назад
good stuff bud'!
@abchannel3737
@abchannel3737 2 года назад
Excellent
@snowmansp
@snowmansp 2 года назад
Hi, once this is done do you re test the gas and do flue readings or as it’s only on the wet side you just do Visual checks for leaks
@cputilitysolutions
@cputilitysolutions 2 года назад
Whenever you've removed a case off a boiler you should do your 26.9 checks 👍🏽
@paulrossiter9567
@paulrossiter9567 2 года назад
Good on ya 👌🏻
@dir5155
@dir5155 2 года назад
Молодец 👍
@dinosauraccounts1411
@dinosauraccounts1411 7 месяцев назад
Hi, I’ve changed the diverter valve. But ch-flow pipe getting hot when hot water is on. Another problem after Changing divertor - the hot water working fine - but heating goes one and rapidly heats up and cuts out - radiator symbol flashes. I did do P0 purging. Still no luck. Any help Would be really good.
@stevenjohnson6082
@stevenjohnson6082 2 года назад
if you turn boiler power off after draining it will tell you if the water pressure sensor is block, if blocked it will still show pressure ie 0.5 or 0.3
@brahimaitoukharaz3039
@brahimaitoukharaz3039 2 месяца назад
hello, I have a vaillant ecotec plus vcw 346 3-5 boiler that works with natural gas and I would like to run it with propane gas. Thanks a lot
@richardmoore8439
@richardmoore8439 5 месяцев назад
I can't get the screws out from the back . All my drivers keep slipping as there seriously tight
@cputilitysolutions
@cputilitysolutions 5 месяцев назад
Large flathead, tap it fairly hard (within reason) from an angle with a hammer to loosen it off anticlockwise
@leeedwards3783
@leeedwards3783 Год назад
What long length screwdriver set do you have for these. I have one where the screws are shot so i need to drill them out. Anyone any advise on which size drill bit i need to drill out the screws. Thanks. Enjoyed the video
@cputilitysolutions
@cputilitysolutions Год назад
I've got a 300mm bit holder that I use for these screws. I've had them chewed up before too but I've managed to free it by hammering a flat head onto the screw head and then able to tap it anti-clockwise to free it up
@leeedwards3783
@leeedwards3783 Год назад
@@cputilitysolutions thanks for the reply. Will have a go at tapping a flat head
@parmbansal1
@parmbansal1 2 года назад
Hi. Managed to follow your instructions. Thank you. I ended up draining the pump relief valve and now it's dripping outside on the copper pipe, what should I do, any tips what to do please? Thanks in advance
@cputilitysolutions
@cputilitysolutions 2 года назад
Yes - never drain from the PRV! Unless you're planning to change it! There's boilers have 2 drain off points, one on the flow and one on the return. You'll need to either clean and re-seat the PRV or replace it.
@parmbansal1
@parmbansal1 2 года назад
@@cputilitysolutions thank you so much for your guidance. I have taken it apart/cleaned the PRV sadly it still drips. I guess the only option is now to replace new one, hope that stops it. Thank you again! Any other tips would be much appreciated.
@SuspiciousPixels
@SuspiciousPixels 2 месяца назад
whats the part number mine has the black top and I want to replace it with the new one. My existing part is DIVERTER VALVE 252457
@adiivanuta2573
@adiivanuta2573 2 года назад
Hi, my boiler is vaillant vuw 260 . The problem is that if the chimney led flashing more than 90 seconds after it doesn't start, just running the pump forever. Any idea why? Thank you!
@cputilitysolutions
@cputilitysolutions 2 года назад
Hi, this would require a diagnosis whilst in front of the boiler
@adiivanuta2573
@adiivanuta2573 2 года назад
@@cputilitysolutions Thanks :(
@johnabiodun5540
@johnabiodun5540 2 года назад
Done the exact same job on the same boiler the other day and when I ran the hot tap nothing happened... No tap symbol on the display nothing! Had to put the old motor back in the new diverter then it worked. Have you ever come across this before?
@cputilitysolutions
@cputilitysolutions 2 года назад
Not come across that before mate, but I've come across a job where I thought it was the diverter as it was passing down heating, changed it and still doing same thing. Ended up being PCB not sending correct voltage to the motor to move it fully back and forth!
@stevenjohnson6082
@stevenjohnson6082 2 года назад
if you have right filling tap open no water comes out of hot tap
@johnabiodun5540
@johnabiodun5540 2 года назад
@@stevenjohnson6082 Water was coming out of the tap but the boiler was doing nothing.
@allsystemsdownagain9553
@allsystemsdownagain9553 Год назад
Nice.
@rodknee87
@rodknee87 2 года назад
Have you ever used the cartridge removal tool and just changed that instead of whole unit?
@cputilitysolutions
@cputilitysolutions 2 года назад
I've heard of it but I've never used it myself yet. May give it a try but I've heard mixed reviews about it. Works for some people, but others have said they've been recalled a short while later because it leaks
@seangribbin6329
@seangribbin6329 2 года назад
@@cputilitysolutions we use them all the time, as long as its installed correctly they are a dream
@leeedwards3783
@leeedwards3783 Год назад
Interesting. What's the cartridge removal tool.
@lloydm2883
@lloydm2883 4 месяца назад
Thanks for this video. Now l know it's a job for a pro.. not me. What would a plumber charge to do this job???
@cputilitysolutions
@cputilitysolutions 4 месяца назад
Labour I charge 150+vat mate 👍🏾
@1Patchilo
@1Patchilo 6 месяцев назад
👏
@cputilitysolutions
@cputilitysolutions 6 месяцев назад
Thanks 👍🏾
@kapilsammy
@kapilsammy 2 года назад
Bro didn't you forgot to take the diverter valve bracket mount screw when you started wiggling it and then said sh$t should come out lol nice video though
@seanmcgee5060
@seanmcgee5060 2 года назад
Take the pump out as well, so much easier
@cputilitysolutions
@cputilitysolutions 2 года назад
Funnily enough this is what I do when I change the complete pump! It's in my other video 👍🏽
@traleyton8057
@traleyton8057 7 месяцев назад
Clearly a very bad design of this 3 port valve. I guess the parts and labor cost exceeded £200. Almost criminal for a inherent bad design.
@cputilitysolutions
@cputilitysolutions 7 месяцев назад
Yeah around £300 total
@AC_Milan1899
@AC_Milan1899 6 месяцев назад
German build quality is so overrated
@cputilitysolutions
@cputilitysolutions 6 месяцев назад
🤣
Далее
Vaillant EcoTec Diverter Valve Replacement | FULL
27:33
QVZ PREMYER LIGA
00:18
Просмотров 448 тыс.
Vaillant ecotec plus loosing pressure
16:37
Просмотров 24 тыс.
Vaillant EcoTec Plus. New diverter valve
13:07
Просмотров 2,1 тыс.