Тёмный

Vokera excel 25 boiler red light fault 

jay Gardner
Подписаться 35
Просмотров 30 тыс.
50% 1

Red light solution for the vokera excel 25 boiler system

Игры

Опубликовано:

 

22 ноя 2018

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 62   
@DeltaV3
@DeltaV3 Год назад
Thank you. One small additional bit of info. I had to keep turning my dial past the power symbol to the "radiator with a line through it" symbol. Then it reset. Thanks again.
@smikabis2717
@smikabis2717 4 месяца назад
Legend!
@mahbub7mib
@mahbub7mib 4 года назад
Had the same problem 2 months ago, had to call engineer to fox it. Same problem today and watched your video and bingo! The little power reset symbol is easily missable! Thanks for the help, mate!
@lmtt123
@lmtt123 4 года назад
I have been using this boiler for two months without any problems until the gas went off today. No hot water this morning and radiators seemed ok, until i looked at the boiler and saw the red alarm bell light. Switched system off and it didn't work. Tried the dial to power icon (bit stiff at first but clicked with a little pressure) and turned thermostat up high. It's firing on high now so fingers crossed! Thanks for sharing.
@Kidderman3
@Kidderman3 5 лет назад
Had a panic call from my daughter earier today. Boiler had stopped working. No heating or hot water. Just a static red light. Googled model number. Found your video. Same boiler, same problem. Turned knob as per your discovery. Boiler reset itself and is now working perfectly. You have my gratitude.
@jaygardner9659
@jaygardner9659 5 лет назад
Excellent stuff, glad it's helped
@rosst3mp
@rosst3mp Год назад
Jay, I wish I could buy you a pint or two - I came home from work and could hear a gurgling sound coming the boiler. Sussed out it was likely the condensate trap blocked, it was, so I removed and cleaned it, draining a fair amount of water from the condenser in the process. Unfortunately after rebuilding it wouldn't fire up, I eventually found this video and it's now back working! Legend!
@gulnaarhussain7891
@gulnaarhussain7891 4 года назад
Thank you thank you thank you!!! I had problems with my gas meter and after the engineer recommissioned the meter, the boiler just would not reset. I did what you did and ran the hot tap and hey presto!!! Light turned green. Thank you so much for uploading this!
@rogerbillings5081
@rogerbillings5081 3 года назад
Thanks for posting - did this and boiler fired up first time. Its been -4 outside all week so this is a life saver. Thanks again!
@scottrhampton
@scottrhampton 10 месяцев назад
Thank you. This worked for me. I had powerd off several times. I was bleeding radiators and increasing the water pressure. Nothing worked apart from this. Nice one. Probably saved me a nasty bill.
@jaygardner9659
@jaygardner9659 10 месяцев назад
Makes me glad I made the video reading comments like this.
@sassdaddy7078
@sassdaddy7078 3 года назад
Thanks mate you’re a life saver! My elderly mum has this boiler. It had turned off and I couldn’t get it to restart. I was thinking I’d call an engineer but as you say, I thought I’d have a look at You Tube first and found your video.
@Andrew_Fernie
@Andrew_Fernie Год назад
Thank you for this. I have the Excel 29 which had stopped due to frozen condensate pipe. I emptied the condendate and like you, turned the power off and on to no avail. I also had not noticed the power symbol on the dial. Turned it off and on again with the dial and hey presto ! Sorted.
@mantonythe1st
@mantonythe1st Год назад
Thank you! I can't believe this actually worked, for some reason I was convinced it just wouldn't work for me, but problem solved! I came home this evening after a week away and boiler had exactly the same issue. Can't believe a solution this simple fixed it. Engineers don't want you to know this one simple trick, and for good reason haha
@desdiamond5700
@desdiamond5700 8 месяцев назад
😂this is not a trick it’s in the manufacturer’s instructions how to reset it. No a secret.
@TruckKun
@TruckKun 2 года назад
Thank you!! I was freezing here, mine was vokera excel 29 and worked just fine
@jaygardner9659
@jaygardner9659 2 года назад
Brilliant, glad it's helped, have a great Christmas
@edcassidy6584
@edcassidy6584 3 года назад
Lifesaver, thanks for posting this
@NatTosh1993
@NatTosh1993 3 года назад
YOU ARE A LIFE SAVER! thank you so much 🙏🙏
@jaygardner9659
@jaygardner9659 3 года назад
You're welcome, glad I can help
@hitjiemuhii5640
@hitjiemuhii5640 4 года назад
Thanks mate had sleep in cold 🥶 for a day call engineer whole..and use you way work 💯 thanks a lot you a star ..
@jaygardner9659
@jaygardner9659 4 года назад
Glad it's helped, thank you
@smcgarvie
@smcgarvie 2 года назад
What a help this morning many thanks for thinking of helping other. Top Bloke
@jaygardner9659
@jaygardner9659 2 года назад
Brilliant, many thanks
@tonylewis472
@tonylewis472 2 года назад
Hi Jay this was very helpful for me so thanks a lot, i did what you suggested and happy to say it solved the problem.. great vid thanks
@jaygardner9659
@jaygardner9659 2 года назад
Hi, thats great to hear, thanks
@JeffLloydsouthport
@JeffLloydsouthport 4 года назад
thanks mate that did the trick and got it going again!
@jaygardner9659
@jaygardner9659 4 года назад
Excellent, glad to help
@tuhin9910
@tuhin9910 4 года назад
What settings should i put it on. Sometimes the radiators are on for ages even when the thermostat is off
@crusadersgaming2630
@crusadersgaming2630 Год назад
Nuce one mate.Thank you!
@drhayleytrower
@drhayleytrower 2 года назад
Thank you!
@jaket2142
@jaket2142 2 года назад
Thank you!!!
@jaygardner9659
@jaygardner9659 4 года назад
Brilliant, glad it helped
@vixxy9255
@vixxy9255 4 года назад
Could you please tell me Is the yellow valve always supposed to be straight down like that not horizontal?
@jonathancollins2682
@jonathancollins2682 4 года назад
@@vixxy9255 inline with the pipe, in this case vertical, means open, turned so across the pipe, in this case horizontal, means closed. Yellow is the colour used to identify gas. If the yellow valve has been in the off position, gas off, and the boiler has tried to fire up the boiler will decide that there is a fault as it won't be able to light or stay lit (if it does initially light) due to no gas supply and will need resetting - as per the video; turn the left hand dial anticlockwise to 9 o'clock (as per a clock face), which is power off, for a couple of seconds then turn the dial back to the required setting. Incidentally turning the dial anticlockwise to 7 o'clock(ish), where the tap symbol is, turns the central heating off but allows the boiler to function for hot water only, known as summer mode. So irrespective of what the thermostat and timer might be telling the boiler to do the heating will not come on as central heating is deactivated at the boiler.
@narfedelacruz9954
@narfedelacruz9954 4 года назад
Hi Jay, have same boiler model but don't know how to top up it's pressure. Pls advise, many thanks
@jaygardner9659
@jaygardner9659 4 года назад
Hi, mine has a filling flexy pipe with a tap on each end, check underneath for it, hope it helps
@simonhendy4255
@simonhendy4255 4 года назад
Thanks mate, did the job 👍.
@krzysztofdrzymala
@krzysztofdrzymala 7 месяцев назад
Hello, I have a Vibe 25a gas stove. I have a problem with turning on the stove.The furnace has a problem with starting. When I hit the integrated circuit board, the furnace starts.The question is which relay is responsible for starting the furnace.
@jaygardner9659
@jaygardner9659 7 месяцев назад
Good morning, unfortunately I'm not a boiler or heating engineer but hopefully there will be someone reading this who is able to help, good luck
@khadijanoor8165
@khadijanoor8165 2 года назад
My boiler is vokera Excel 29, it's working but no hot water, what can I do please help me, many thanks.
@amandagallagher9284
@amandagallagher9284 5 лет назад
I’ve had same problem, tried all that, and it only stays on for 5-10 mins, then goes back to red
@jaygardner9659
@jaygardner9659 5 лет назад
Tbh I've had them out twice since making this video to fix the pressure valve as it's only 6 months old, hope you get yours fixed asap
@Lycanthias
@Lycanthias 4 года назад
hello. i am living in a shared house and the house has the same model, normally when it buil water you only can see one red light in the top( the top one) sometimes it stop to buil water without know why, and the light number 3 is one in red and the top one in green and it doesnt warn up the water
@Lycanthias
@Lycanthias 4 года назад
do you know why it could be?
@jaygardner9659
@jaygardner9659 4 года назад
To be honest I only put this video up on RU-vid to help others who might come across the same issue, I don't claim to be a heating or boiler engineer, what I have found with mine thou is if you run the cold tap anywhere in the house the boiler will fire up straight after...Not sure why that is but it's never bothered me
@lolpot7780
@lolpot7780 4 года назад
So we had a power cut, found the little notch to switch it to like you suggested but it still goes back to red afterwards, tried running water and everything like you guys have suggested. From my slight experience I feel like I'm missing the pilot light clicking on, it feels like it wants to fire up, but I have no idea even if we can do anything about it. I've not lived in this house through the winter (I rent) so I haven't the foggiest and it seems even engineers that come out to you guys don't either! Bit worried to say the least, any help would be appreciated
@jaygardner9659
@jaygardner9659 4 года назад
@@lolpot7780 hi, there's not really much more I can suggest really other than have you tried any other gas appliances in the house to make sure there is gas? If other gas appliances work and the on/off switch doesn't work then I'm guessing the boiler has some sort of fault and you should contact a heating engineer, hope you get it sorted soon
@jaygardner9659
@jaygardner9659 4 года назад
@@lolpot7780 Oh and obviously check the remote thermostat is working ok an the demand for heat is there I.e turn it to manual and turn up the temp
@RB-jq6gh
@RB-jq6gh 2 года назад
I think when the system has been turned off then on it goes through a purge on startup...don't think it's a serious fault.
@afizah44
@afizah44 2 года назад
My boiler is exact same and i just cannot seem to get it to work😭😭
@jaygardner9659
@jaygardner9659 2 года назад
Hi, so I take it you've tried the restart as in the video? Failing that make sure it has power an gas supply, and the water pressure is above 1, let me know if you get it sorted, best wishes
@afizah44
@afizah44 2 года назад
@@jaygardner9659 hi Jay yes it does have power and gas. I did it step ny step as your video and the green light is just flashing. Thanks for replying to me
@jaygardner9659
@jaygardner9659 2 года назад
Green light is good, I'm guessing it just needs the temperature turning up on the remote? But I'm no heating expert, just hope you get it sorted as no1 needs the boiler playing up at this time of year
@afizah44
@afizah44 2 года назад
@@jaygardner9659 thankyou so much. Done all that still no joy. Thanks
@farooqahmed8658
@farooqahmed8658 8 месяцев назад
Goof video but dragged, even 2 minutes seem long these days since tiktok has been around
@thebadgerbhoy5694
@thebadgerbhoy5694 2 года назад
Thank you!
Далее
Fault Finding Webinar Highlights
6:15
Просмотров 9 тыс.
QVZ PREMYER LIGA
00:18
Просмотров 841 тыс.
Vokera Linea 28 No Hot Water
4:31
Просмотров 27 тыс.
Vokera riello excel 25 boiler leak
3:09
Просмотров 95
Vokera Compact 25A service modes
2:21
Просмотров 6 тыс.
Vokera Boiler Tutorial
7:32
Просмотров 120 тыс.
S.T.A.L.K.E.R. 2: Heart of Chornobyl - Really, Again?
0:45