Vokera Linea Repair. Heating On With Hot Water. Combi Boiler Repair 

HeatingGeek
Подписаться 28 тыс.
Просмотров 52 тыс.
50% 1

I attend this after another engineer and found something weird. Vokera boiler repair.
To support this content and get access to the PDF files to go with this training click here: / heatinggeeks
The PDFs for this video are not done yet!!! SOON.
Injector cleaning tool: rover.ebay.com/rover/1/710-534...
To support the channel and see the tools used day to day by me check out the links below:
1) CARHARTT Tool Roll amzn.to/2yGiexO
2) BAHCO Screwdriver with LED amzn.to/2Op5Ug1
2)BAHCO Screwdriver without LED amzn.to/2yEhLML
3)WERA Kraftform Kompakt Screwdriver amzn.to/2OnOe4K
4)WERA 0.8x4x100 Flat screwdriver amzn.to/2RNcpra
5) KNIPEX Alligator amzn.to/2RNctqU
5)KNIPEX Cobra amzn.to/2PA5YWY
same size as the alligator above just the “cobra” version
6)BAHCO Spanner amzn.to/2IW3iR8
6)BAHCO Spanner with slimline jaw amzn.to/2yHCq2i
7)CK Wire cutters amzn.to/2RP19dW
7)CK Wire cutters (shorter version) amzn.to/2OnJwnB
8)KNIPEX bent long nose pliers amzn.to/2IW9uZ3
9)TESTO 510 Digital U gauge amzn.to/2Cfz36a
9)TESTO Bluetooth U gauge amzn.to/2IW4t30
10)Mirror tool amzn.to/2OpKVKl
11)Cheap as chips pick set!!! amzn.to/2OpK10o
12)FLUKE alert volt stick amzn.to/2PxCYPF
13)MONUMENT Tailing Spanner amzn.to/2OrypK8
14)Tee Bar 4mm amzn.to/2yDPRAr
15)Tee bar 2mm amzn.to/2yzbjGA
16)Tee bar 2.5mm amzn.to/2OqqSvd
17)Full Tee bar set amzn.to/2yAoIyk
18)10mm ratchet spanner (flex head) amzn.to/2IWCoZ9
19)8mm ratchet spanner (flex head) amzn.to/2IUDZP5
20)14mm/15mm spanner amzn.to/2Aa6wgZ
21)BAHCO small spanner amzn.to/2RRkKKH
22)Cheap Lock knife amzn.to/2IWatZf
23)Sharpie amzn.to/2IVrxPk
24)Injector cleaning pins link coming soon. Review to follow.
25)Rothenberger 18” heavy-duty pipe wrench amzn.to/2ChkRd6
These are the heat duty ones I use.
26)Knipex (large) amzn.to/2OrgfIm
27)BAHCO 12” (not wide jaw) amzn.to/2Aatuob
28)Fluke 115 multimeter amzn.to/2OqaFpF
Drain down hose amzn.to/2RM4ZEN
Gas Tap Grease amzn.to/2SE0jRL
Led lights for the ​van. amzn.to/2Bh7RTQ
Fluke 101 multimeter amzn.to/2PoLP5g
Extech EX330 amzn.to/2AYq872
Silicone grease amzn.to/2Rnls4F
Fluke Twist Guard probes
amzn.to/2CfwCz4
Commando drills
amzn.to/2L5f50u
Weed Sprayer amzn.to/2Ryx1Hh
Large LDF amzn.to/2I0ss4d
NTC Clamps:
amzn.to/2GVUWL5

Опубликовано:

 

12 авг 2018

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 127   
@Rickblues46
@Rickblues46 4 года назад
Love it with your logical step by step approach to fault finding your like a dog with a bone and don’t let em beat you ... and a total credit to the profession !
@HeatingGeek
@HeatingGeek 4 года назад
Thanks :-) I like fixing things and working out the logic of them. The logic a boiler works too is important to understand. :-)
@yensabi
@yensabi 6 лет назад
Another nice diagnostic repair / fault find , you are very methodical in your approach to the problem in front of you and the way you test and check each component is top notch......👍 Looking forward to another video soon Cheers.......👍
@HeatingGeek
@HeatingGeek 6 лет назад
Thanks a lot. There wasn't a fault with the boiler!!!! Crazy. ;-)
@simpsongary98
@simpsongary98 6 лет назад
Ave liked it before ave watched it cause I no it will be top notch 👍keep it up pal
@HeatingGeek
@HeatingGeek 6 лет назад
THANKS ;-) NOT MUCH TO THIS ONE
@MattCuddeford
@MattCuddeford Год назад
Thank you!! Your videos are priceless 🙏🏼
@HeatingGeek
@HeatingGeek Год назад
Glad you like them.
@BoilerMend
@BoilerMend 5 лет назад
Great work dude😎
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks. :-)
@markray9685
@markray9685 5 лет назад
This bloke knows his stuff. Top video.
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks.:-) I get things wrong all the time....
@bluenose007
@bluenose007 5 лет назад
@@HeatingGeek Was he charged for the parts that didnt need changing
@HeatingGeek
@HeatingGeek 4 года назад
@@bluenose007 No it was covered by the insurance company. :-)
@bluenose007
@bluenose007 4 года назад
@@HeatingGeek So it was charged
@HeatingGeek
@HeatingGeek 4 года назад
@@bluenose007 The customer paid the same monthly fee they always pay. So not directly.
@leaturk11
@leaturk11 5 лет назад
again a good insight
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks ;-)
@SuperJinxter
@SuperJinxter 4 года назад
Really interesting viewing. Cheers!
@HeatingGeek
@HeatingGeek 4 года назад
Glad you like it. :-)
@mdillon1976
@mdillon1976 3 года назад
Good vid nice one HG👍
@HeatingGeek
@HeatingGeek 3 года назад
Thanks 👍
@evgenigenchev2430
@evgenigenchev2430 4 года назад
you are better than a magician mate
@HeatingGeek
@HeatingGeek 4 года назад
I wish it was that easy all the time. :-)
@mikearthur2586
@mikearthur2586 4 года назад
so how did you fix the problem. I.e stopping the flow to rads on high temps without turning the timer on boiler off.?
@evgenigenchev2430
@evgenigenchev2430 4 года назад
yea everything is fixable ...hmm wish I can say that just like you do. Great vid
@HeatingGeek
@HeatingGeek 4 года назад
Most things are :-)
@woodbine66
@woodbine66 6 лет назад
It's true what they say - every day is a school day. Always learning. Don't know what all that LSX was about. Yeehaar!! O rings should have been sufficient to seal if they were good - if they were bad, they should have been replaced. Only thing to go on o rings should be a little sillycoon grease. Thanks for another fantastic vid, HG. Please keep them coming. Ian
@HeatingGeek
@HeatingGeek 6 лет назад
Thanks. :-)
@MrU2U8E
@MrU2U8E Год назад
great video very informative, any idea why my new diverter valve (vokera 28he) leaks through the pin when i turn the return valve on. there is no blockage in the housing is there supposed to be a seal between the valve and actuator.
@HeatingGeek
@HeatingGeek Год назад
the actuator should remain dry. so i guess you have a problem. i cant really help anymore without knowing more..
@yasernabiloo2499
@yasernabiloo2499 4 года назад
very good
@mechtechmechanical1571
@mechtechmechanical1571 5 лет назад
another great vid nevergive up is the name of the game
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks. :-)
@MrLibbyloulou
@MrLibbyloulou 5 лет назад
very good vid......what name are the heating clamps where would i find some? thanks
@HeatingGeek
@HeatingGeek 5 лет назад
K type clamps. :-) amzn.to/2GVUWL5
@matttate9155
@matttate9155 4 года назад
I like your videos man. Keep em coming! You’ve got a zen type depth of understanding all things boiler. Lol Question I have is, how much are you self taught with your own experiences, or how much manufacturers courses have you been on?
@HeatingGeek
@HeatingGeek 4 года назад
Up until a couple of years ago I never went on a manufactures course. Just be open to learning and trying new things. Play with boilers and phone manufactures all the time. :-)
@kombiklimaustasi
@kombiklimaustasi 6 лет назад
Good.
@HeatingGeek
@HeatingGeek 6 лет назад
THANKS ;-)
@monkmsm
@monkmsm 2 года назад
This is the part of the job I love, would have stopped years ago if it wasn't for fault finding and diagnosis. was really keen like you but I have lost the passion for it over last few years, so got lpg to reignite it few years back. Going to get oil as just moved to the sticks. so hopefully that will bring it back. you do much oil??
@HeatingGeek
@HeatingGeek Год назад
Not very much oil. I do like it but only when its outside or in a plant room.
@mmack3286
@mmack3286 5 лет назад
Have you ever replaced the expansion vessel on the vokera boiler? Do you need to remove the burner completely out?
@HeatingGeek
@HeatingGeek 5 лет назад
Im not sure. I don't remember ever doing it.
@gringo1
@gringo1 4 года назад
My baxi boiler did the same hw on then off the on again and dumping into the rads, heat/ex was blocked so maybe it's a safety measure
@HeatingGeek
@HeatingGeek 4 года назад
Could be. It might be a safety thing. I didn't think of that :-)
@cliftonpoynter388
@cliftonpoynter388 5 лет назад
I must have fitted dozens of Linea's and still service a couple i fitted 16 years ago (approx) and still going strong. Common problems were the front of hydraulic block plastic cover and guts available as service kit but very common problem was customer unable to generate hot water or not hot enough and rads not hot enough although both stats turned up full, the fault would be the plastic stat knobs had actually snapped, so although the stats were set at high they were'nt, the spindle behind the knob which inserted into to two variable resistors on the pcb were snapped hence knobs doing nothing. Vokera modified these so problem sorted albeit the first time I had this problem it must have took me 3 hours to find the fault, good boilers. Vokera brought out the Excel after this which came no where near the Linea. The new range very impressive.
@HeatingGeek
@HeatingGeek 5 лет назад
I thought the excel was older!! shite boiler.
@cliftonpoynter388
@cliftonpoynter388 5 лет назад
@@HeatingGeek Your right, it was older, Maxim aswell i think, utter shite.
@Shandanks
@Shandanks 3 года назад
So in normal operating conditions should the boiler be reaching 80+ degrees in DHW mode or is that due to it’s age and possible scale/restriction within the primary circuit. I understand why it dumps the heat into the CH system but wasn’t sure if it should be getting that hot in the first place
@HeatingGeek
@HeatingGeek 3 года назад
It shouldn't really be getting that hot :-)
@Rickblues46
@Rickblues46 4 года назад
With the Linea is there no internal auto- bypass to dump localised heat instead of utilising the heating circuit ???
@HeatingGeek
@HeatingGeek 4 года назад
I'm not sure tbh. A while ago this one.
@welshe222
@welshe222 4 года назад
I have this same issue and im afraid to call a plumber because of the price! is there some way i can tell and fix this issue myself? also one tap makes a massive loud noise when turned on for 1-2 seconds, thanks
@HeatingGeek
@HeatingGeek 4 года назад
Sorry, I cant help. You will need to get a local GasSafe registered engineer. Good luck and I hope you get it sorted.
@krosfala
@krosfala 5 лет назад
thank you so much for your videos man.There s been a few days i came across your vids and oh man!I saw in other vids you put links for some tools,could you tell me or put a link for this temp gauge on this vid.I use a thermal camera but this looks far more acurate.Thanks again man,hope life pays you back for the help
@HeatingGeek
@HeatingGeek 5 лет назад
Clamps: amzn.to/2GVUWL5 Sorry I took so long to get back to you. Im a bit stretched at the moment trying to get enough work in. :-)
@krosfala
@krosfala 5 лет назад
@@HeatingGeek Thanks so much.Hope everything goes smooth with work cause you deserve a really fat income man.
@HeatingGeek
@HeatingGeek 5 лет назад
@@krosfala Hopefully one day. :-)
@MrCannonfodder1
@MrCannonfodder1 5 лет назад
Boiler is repaired! Sorry about the s**t comment I left before, was absolutely no call for what I said and definitely no excuse for it!! I was being a knob, keep up your good work man 👍
@HeatingGeek
@HeatingGeek 5 лет назад
No problem. Glad you got it sorted :-) I don't even mind the comment!
@jonathanalder1206
@jonathanalder1206 Год назад
Had exactly this today. Diverter pin seized spike so changed the diverted valve. After which with just HW no heat down the flow but with HW and CH heat also went down the flow and to the hot tap. Question why is this a neat trick? I still don’t get the logic/advantage?
@HeatingGeek
@HeatingGeek 6 месяцев назад
If you have the heating on but run a bath for 15 min the heating will cool down. With this Logic on the boiler it will still send some heat out.
@buzzardc7
@buzzardc7 6 лет назад
Hey. Are the temp clamps made by Kane?
@HeatingGeek
@HeatingGeek 6 лет назад
NO.
@12subzer0
@12subzer0 5 лет назад
Hi could you explain what you were doing when testing the high and low with the manometer specifically what you where taking off from the gas valve and what this was simulating. Is this how you alternate from high to low with out using the display??
@HeatingGeek
@HeatingGeek 5 лет назад
I was pulling off the modulation lead so the gas valve dropped the gas pressure to "low".
@colinfleming2244
@colinfleming2244 4 года назад
Wish the company I work for gave me as much time as you to fault find
@lordjohn9191
@lordjohn9191 6 лет назад
as always great vid. David Iszchak at volkera will be happy with your review haha. im wondering if the previous engineer used his temp clamps or maybe just felt the pipes and presumed it was passing.
@HeatingGeek
@HeatingGeek 6 лет назад
TBH I JUST USE MY HAND USUALY. I ONLY GET THE CLAMPS OUT FOR YOU GUYS!!
@stephenmckenna8699
@stephenmckenna8699 Год назад
Hi i have one with a loud screeching noise seems to be near the diverter valve would replacement sort this? Thanks
@HeatingGeek
@HeatingGeek Год назад
is it on heating or hot water?
@stephenmckenna8699
@stephenmckenna8699 Год назад
Both when either switched on
@HeatingGeek
@HeatingGeek Год назад
@@stephenmckenna8699 It sounds like something vibrating when the pump runs. So diverter or bypass might be the cause.
@normanboyes4983
@normanboyes4983 3 года назад
Just catching up with your back catalogue. Love your logical fault finding approach.👍 If I followed the progression of this correctly there was never a fault with the boiler, the customer/engineer just did not understand the boiler control panel and the logic within?
@HeatingGeek
@HeatingGeek 3 года назад
Yep, I think so. :-)
@SalimKhan-gk1fh
@SalimKhan-gk1fh 6 лет назад
Another excellent video mate! keep them coming please LOL! In all honestly that non condensing boiler should be replaced on efficiency terms alone, but I suppose that’s their choice, What do you reckon of viessmann boilers ? I’ve been fitting them past 4 to five years now and I’m very impressed by them ,nice & easy to fit / work on, also the customers are pleased too , Especially in regards to quietness and efficiency Some saying savings of 40%!
@SalimKhan-gk1fh
@SalimKhan-gk1fh 6 лет назад
Jonny Mosquito Strawman at Large . Hi Johnny thanks for your comment and I suppose I have to agree with you. I’m from down south of England and here we replace boilers for no reason at all with new ones. I’ve seen them replaced when all they needed where diaphragms or thermistors. Some of the big companies are worse for replacing for no reason
@SalimKhan-gk1fh
@SalimKhan-gk1fh 6 лет назад
Jonny Mosquito Strawman at Large Yes I know what you mean mate, down here some guys don’t even take the cover off to have a look at the fault But simply condemn it as ‘end of life too old’! Looks like boilers are going down the fridge /washing machine route ie knackered after 5 years!
@HeatingGeek
@HeatingGeek 6 лет назад
Im not too familiar with Viessmann. It would nice nice to learn more about them (Hint Hint). I recon this boiler will/could outlast any boiler fitted today. All old boilers were made to Last.
@HeatingGeek
@HeatingGeek 6 лет назад
I agree. I wish I could buy a Vaillant Turbomax Plus for my house. Best combi boiler ever made I recon.
@HeatingGeek
@HeatingGeek 6 лет назад
Its how big companies make money. In London you have to buy a new van every 5 years or else TFL take your pants down. Its big business selling efficiency .
@TheRealBillyKent
@TheRealBillyKent 6 лет назад
Great vid again mate! Do you prefer the kane to anton?
@HeatingGeek
@HeatingGeek 6 лет назад
Kane. It dosen't take 45min to purge 10000ppm of CO out of it. I do like how quick Anton print and how small they are. I hate the water trap on Antons too.
@TheRealBillyKent
@TheRealBillyKent 6 лет назад
HeatingGeek completly with you on the purge and water traps! Pain in the backside mate, I have anton atm and always have had but thinking of making the swap 👌🏻. Did here that kanes tend to flap a bit when they get high amounts of co...?
@HeatingGeek
@HeatingGeek 6 лет назад
I found the Antons were worse!! It might just have been the one I had??
@TheRealBillyKent
@TheRealBillyKent 6 лет назад
HeatingGeek My antons have always been fine with high co, the new anton has a Bluetooth connection you can link to your phone which is good but feeling a change and the kane seems to be real popular 👍🏻
@MayYouLiveLongAndProsper
@MayYouLiveLongAndProsper Год назад
Good video ... Might I suggest a tripod or even a head cam to make your life easier
@davebayliss3142
@davebayliss3142 2 года назад
I live near you , can I come work was for you ??
@brendanfisher2528
@brendanfisher2528 6 лет назад
do you work for yourself or for a company or do you subcontract to companys?
@HeatingGeek
@HeatingGeek 6 лет назад
Both. And everyone
@Thegasman414
@Thegasman414 3 года назад
Question!! When the Boiler dumps water into heating side. This is obviously a Vokera design??? Just so I get it right But brilliant fault finding btw Dan
@HeatingGeek
@HeatingGeek 3 года назад
Yeah, must be .:-)
@colinfleming2244
@colinfleming2244 4 года назад
They also hav bad habit of the front display sticking on Co mode if turned from ch/hw mode to just hw if customers use that to turn ch off
@HeatingGeek
@HeatingGeek 4 года назад
I know. Vokera tell you to replace the knob (comes in 2 parts) , but that doesn't fix it. Whats the deal?
@colinfleming2244
@colinfleming2244 4 года назад
@@HeatingGeek always worked for me once I new about it quick easy way to tell if and it usually is the plate blocked quick whip out plate some coke and blast it with a pango I made up a hose and tapered plug to put in the hole just do it under water in a bucket or ye get coke all over yer self safer than chemicals
@HeatingGeek
@HeatingGeek 4 года назад
@@colinfleming2244 You use a pango!!! I never thought of using it for that. :-)
@jamiehunt7362
@jamiehunt7362 6 лет назад
Lsx is the devils work. You'll be back there soon to unblock the plate heat x where the lsx has blocked it!! Good work again tho!
@HeatingGeek
@HeatingGeek 6 лет назад
Not my LSX!!!!! I only use LSX for proper bodges!!!
@seychelles44
@seychelles44 5 лет назад
Was this OK after a few day's?
@HeatingGeek
@HeatingGeek 5 лет назад
Yes. it never came back as far as I know. I always leave my number with people to call me so I know if things have come back.
@seychelles44
@seychelles44 5 лет назад
@@HeatingGeek Thank you for your reply. But would you not have thought the boiler is old, has been running for years and probably in the heating and hot water mode before. But did not cause any issues previously!? I wonder if/did Vokera confirm there boilers do have that function and that it's not a faulty pcb?
@HeatingGeek
@HeatingGeek 5 лет назад
@@seychelles44 I never checked and the customer didn't call me so i assumed it was all ok. You could be correct.
@andylucas3724
@andylucas3724 3 года назад
Probably working on safety stat should modulate not go off blocked plate
@k20aa
@k20aa 6 лет назад
What was the cost to repair that ?
@k20aa
@k20aa 6 лет назад
The point i was trying to make was . The parts and labour was it worth it . The time it took they could have replaced it
@k20aa
@k20aa 6 лет назад
'Jonny' As for the cost, decent engineer's offer a no fix no fee or a fixed labour charge There is no way the guy could have changed that lot in a fast time How much would you want to sit in front of that hours worth of work Im sorry but the amount of hours that would have taken would not warrant that and the price of the spares . Fair play to the heating geek he is a very good engineer and really is good at fault finding . Glowworm etc etc will walk away from older boilers due to the crazy cost of parts its not economical . The cost of a new combi with 7 year warranty bad A I know what id rather have
@HeatingGeek
@HeatingGeek 6 лет назад
These are all fixed price repairs or insurance work. So the customer has paid a monthly charge or a one off fixed price.
@paulhughes2367
@paulhughes2367 5 лет назад
Walk through door '' sorry love its a vokera you need a new boiler ''
@HeatingGeek
@HeatingGeek 5 лет назад
No!!!! Keep it going as long as possible so the manufactures don't steal all the service and repair work. Some for 10 years now.
@colinfleming2244
@colinfleming2244 4 года назад
The vokera check for primary blockage is run hw if burner cuts out turn valve off so no water to hw if display goes above 90 blockage in primary circuit sorry prob preaching to the converted no bad boilers lines bog standard boilers but not great for hw flow
@HeatingGeek
@HeatingGeek 4 года назад
I didn't know that was the Vokera check!! I find it weird that the plate connection has anon-return valve in it. I like Vokera tbh. Also, the technical help is usually spot on.
@colinfleming2244
@colinfleming2244 4 года назад
@@HeatingGeek the bypass bobbin is a nightmare to get out and in again
@HeatingGeek
@HeatingGeek 4 года назад
@@colinfleming2244 In again??? :-)
@williammcgrattan9583
@williammcgrattan9583 6 лет назад
I take it, these are new tenants to this property? They just didn't wake up one day and notice that the rads were getting hot.
@HeatingGeek
@HeatingGeek 6 лет назад
No! the engineer made the mistake thinking it was still passing after he fixed it!
@daviddaywalker3844
@daviddaywalker3844 5 лет назад
Old ones are the best ones in some cases
@HeatingGeek
@HeatingGeek 5 лет назад
Old ones are defiantly better than new ones. Vaillant Turbomax Plus would be my choice of any boiler
@lazenbytim
@lazenbytim 4 года назад
I'd bet my dog there's a massive lump of LSX in the diverter valve. Intermittent fault.
@drone1028
@drone1028 4 года назад
What is LSX?
@BELHORIZON31
@BELHORIZON31 2 года назад
Purchase a fix camera!
@HeatingGeek
@HeatingGeek 2 года назад
Like what?
@anthonygreenwood4486
@anthonygreenwood4486 5 месяцев назад
Swap it
@HeatingGeek
@HeatingGeek 4 месяца назад
What?
Далее
Alpha CD35 C Combi Boiler Repair. Beginning to end.
23:39
I Wouldn't Do This For A Customer.....
36:36
Просмотров 29 тыс.
Vokera Compact 35 HE combi Boiler water leak repair.
14:25
Plumbers from hell left this behind
14:56
Просмотров 75 тыс.
The elbi diverter motor stripped down
6:53
Просмотров 8 тыс.