Glowworm Ultimate Not Lighting. HeatingGeek Boiler Repair. No Pilot 

HeatingGeek
Подписаться 28 тыс.
Просмотров 72 тыс.
50% 1

Injector Tool Back In Stock :
INJECTOR CLEANING TOOL.
rover.ebay.com/rover/1/710-534...
How I fix this boiler after another engineer couldn't find the issue.
Check out this video: • Gas boiler repair. Inj...
1) CARHARTT Tool Roll amzn.to/2yGiexO
2) BAHCO Screwdriver with LED amzn.to/2Op5Ug1
2)BAHCO Screwdriver without LED amzn.to/2yEhLML
3)WERA Kraftform Kompakt Screwdriver amzn.to/2OnOe4K
4)WERA 0.8x4x100 Flat screwdriver amzn.to/2RNcpra
5) KNIPEX Alligator amzn.to/2RNctqU
5)KNIPEX Cobra amzn.to/2PA5YWY
same size as the alligator above just the “cobra” version
6)BAHCO Spanner amzn.to/2IW3iR8
6)BAHCO Spanner with slimline jaw amzn.to/2yHCq2i
7)CK Wire cutters amzn.to/2RP19dW
7)CK Wire cutters (shorter version) amzn.to/2OnJwnB
8)KNIPEX bent long nose pliers amzn.to/2IW9uZ3
9)TESTO 510 Digital U gauge amzn.to/2Cfz36a
9)TESTO Bluetooth U gauge amzn.to/2IW4t30
10)Mirror tool amzn.to/2OpKVKl
11)Cheap as chips pick set!!! amzn.to/2OpK10o
12)FLUKE alert volt stick amzn.to/2PxCYPF
13)MONUMENT Tailing Spanner amzn.to/2OrypK8
14)Tee Bar 4mm amzn.to/2yDPRAr
15)Tee bar 2mm amzn.to/2yzbjGA
16)Tee bar 2.5mm amzn.to/2OqqSvd
17)Full Tee bar set amzn.to/2yAoIyk
18)10mm ratchet spanner (flex head) amzn.to/2IWCoZ9
19)8mm ratchet spanner (flex head) amzn.to/2IUDZP5
20)14mm/15mm spanner amzn.to/2Aa6wgZ
21)BAHCO small spanner amzn.to/2RRkKKH
22)Cheap Lock knife amzn.to/2IWatZf
23)Sharpie amzn.to/2IVrxPk
24)Injector cleaning pins link coming soon. Review to follow.
25)Rothenberger 18” heavy duty pipe wrench amzn.to/2ChkRd6
These are the heat duty ones I use.
26)Knipex (large) amzn.to/2OrgfIm
27)BAHCO 12” (not wide jaw) amzn.to/2Aatuob
28)Fluke 115 multimeter amzn.to/2OqaFpF
Drain down hose amzn.to/2RM4ZEN
Gas Tap Grease amzn.to/2SE0jRL
Led lights for van. amzn.to/2Bh7RTQ
Fluke 101 multimeter amzn.to/2PoLP5g
Extech EX330 amzn.to/2AYq872
Silicone grease amzn.to/2Rnls4F
Fluke Twist Guard probes
amzn.to/2CfwCz4
Commando drills
amzn.to/2L5f50u
Weed Sprayer amzn.to/2Ryx1Hh
Large LDF amzn.to/2I0ss4d
NTC Clamps:
amzn.to/2GVUWL5

Опубликовано:

 

31 янв 2019

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 238   
@HeatingGeek
@HeatingGeek 5 лет назад
Sorry about the sound. Don't know how to sort it!!!!!
@TomPalacki
@TomPalacki 5 лет назад
Sound it's not a problem 👍Content matters
@proteus1
@proteus1 5 лет назад
HeatingGeek sounds like the camera pre amp. Or reset software and reformat card. Your a fault finder. Dodgy cable with broken wire perhaps.
@HeatingGeek
@HeatingGeek 5 лет назад
Its fine in the editor. If I export earlier versions of this video the sound is fine. I need someone to help me who knows about Davinti Resolve software.
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks. :-)
@alanmurphy3584
@alanmurphy3584 5 лет назад
HeatingGeek what happened to the link for the cleaning pins ?
@mramicus6917
@mramicus6917 5 лет назад
THIS IS ONE OF THE GOOD GUYS ! YOU CAN TELL HE'S BEEN WELL TRAINED ! I CALL HIM TO FIX MY BOILER AS I KNOW HE WOULDN'T RIP ME OFF !!!
@HeatingGeek
@HeatingGeek 5 лет назад
No ned to rip people off. There is enough money in this job for most people. :-)
@leaturk11
@leaturk11 5 лет назад
Nice to see a fellow gas engineer doing a proper job. Nice one
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks. :-)
@itsrubes9779
@itsrubes9779 3 года назад
Brilliant and knowledgable video heating geek, I’m learning so much from you, thank you, keep posting, top man.
@user-li8gr8ur8l
@user-li8gr8ur8l 5 месяцев назад
Another cracking diagnosis. Nobody goes through the obvious basics like you do Ollie. True legend
@HeatingGeek
@HeatingGeek 5 месяцев назад
Thank you. Going back and watching the Old videos now. ;-)
@peterbeck493
@peterbeck493 2 года назад
Fixed one today thanks for the help Ollie. That burner adjustment is poorly designed too much in the way. Come back soon. Your vids are spot on mate
@lucanspittle8213
@lucanspittle8213 5 лет назад
Excellent video for newbies like myself. I fixed my aunts and bought some injector cleaners too before I saw this. However it's very thorough!
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks. :-)
@henrybartlett1986
@henrybartlett1986 2 года назад
These are great boilers, shame so many have been taken out. Excellent presentation as ever.
@jf6624
@jf6624 5 лет назад
@HeatingGeek Thanks for the videos, I’ve learnt so much from them! 👍
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks for watching them. ;-)
@Stillbusy105
@Stillbusy105 5 лет назад
Solid fault finding as always 👍 nice test to see if the pilot solenoid was open too, I’ll have to remember that one!
@HeatingGeek
@HeatingGeek 5 лет назад
Its the simple tests that people often forget. I do too. :-)
@DuskHorizon
@DuskHorizon 2 года назад
This was lovely, thank you. I had an electrical fault on mine which turned out to be the overheat thermostat being "engaged" without the button sticking out. Your video was helpful in knowing what to expect with the case off and how to get the control box out & open.
@HeatingGeek
@HeatingGeek 2 года назад
I'm glad it helped. All up and running now?
@DuskHorizon
@DuskHorizon 2 года назад
@@HeatingGeek all good, it hasn't popped again. I had a bad PCB in my BoilerMate II; it was buzzing and the pumps didn't work very well. Must have driven the boiler and not taken the hot water away well enough. One of those that makes total sense in hindsight.
@Memories4lifemedia
@Memories4lifemedia 5 лет назад
Thanks for getting more of the injector cleaners I have managed to order one now thanks
@HeatingGeek
@HeatingGeek 5 лет назад
They are a pain to get hold of. Took over a month. Be gentle with it and it will last. (I have broken 2 in a couple of years)
@gasmark340
@gasmark340 5 лет назад
Pukka vid... keep them coming. I used to do installs and now do repairs and breakdowns mainly. Your vids are brilliant!
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks. I have some good ones coming. When I have time.
@MikeDee79
@MikeDee79 8 месяцев назад
Wish I found this video last week as had same issue. Nicely done and helpful 👍👍
@richgreeeat8736
@richgreeeat8736 5 лет назад
Thanks so much for these videos and your channel, it's helping me a lot mate.
@HeatingGeek
@HeatingGeek 5 лет назад
No problem. Im glad it helps. :-)
@gonzalomartinez1630
@gonzalomartinez1630 5 лет назад
Great diagnostic skills, another happy customer! Thanks for sharing!
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks for watching something with audio this bad!!! :-)
@paulmc3870
@paulmc3870 5 лет назад
Really good video, proper fault finding skills for all to see
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks. :-)
@DubSalvation
@DubSalvation 5 лет назад
Reading the comments, you seem to have alot of fans! Good for you bro.
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks. :-)
@theplumbersmate2471
@theplumbersmate2471 5 лет назад
Another great vid keep up the good work. I’m also a gas safe engineer it’s good to see how other engineers work and the tools they use. I like your logical thinking when fault finding . Great content no swearing and no silly nonsense so refreshing. 👍🏻
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks.for watching it. The sound is really bugging me!!! :-)
@boilers24-7
@boilers24-7 5 лет назад
Keep them coming mate.... always looking forward to your videos
@HeatingGeek
@HeatingGeek 5 лет назад
I will got loads filmed. no time to edit
@robwood1983
@robwood1983 5 лет назад
Another great vid regardless of the sound!
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks. Im glad you liked it. Got another one coming soon. :-)
@tomstrutton4351
@tomstrutton4351 5 лет назад
Blocked injector really common on them, excellent video
@HeatingGeek
@HeatingGeek 5 лет назад
Very very common. Love this fix too.
@yensabi
@yensabi 5 лет назад
Another good diagnostic video HG........pity the sound was bad , thought you had turned into a darlek......😀 cheers mate....👍
@HeatingGeek
@HeatingGeek 5 лет назад
I didn't hear it on editing. I will try and sort it out.
@Anthony-hs8zi
@Anthony-hs8zi 5 лет назад
Absolutely brilliant video again thanks
@HeatingGeek
@HeatingGeek 5 лет назад
Good glad it helps. :-)
@Stillbusy105
@Stillbusy105 4 года назад
Great video, helped me on a repair today 👍 my injector pins were still too big to fit the injector holes tho 😏 I only purchased them as I see they come in handy on your vids 😅
@HeatingGeek
@HeatingGeek 4 года назад
You should buy my injector pin then. Very Very small. Does 99% of them. rover.ebay.com/rover/1/710-534...
@Aw4ken3d
@Aw4ken3d 2 года назад
@@HeatingGeek can you lead us to good injector pin at the moment? Cuz this link dont lead you to the one :)
@javidmohammed9498
@javidmohammed9498 3 года назад
Well done good video always learning something new.
@HeatingGeek
@HeatingGeek 3 года назад
Glad to hear it
@AllenHart999
@AllenHart999 5 лет назад
I feel honoured that you add me and PB Plumber in your tags, Great videos, and very interesting channel. Keep up the good work.
@HeatingGeek
@HeatingGeek 5 лет назад
Im Honoured you commented on one of my videos. You have been doing this a long long time and I didn't realise how big Gaschat etc was!!! Well done! :-)
@HeatingGeek
@HeatingGeek 5 лет назад
I spell your name wrong I think!!!
@alanmurphy3584
@alanmurphy3584 5 лет назад
Allen Hart all 3 of you are doing a Stella job, picked up some good info from all your vids, thanks to PB I got myself a veto pro pack and I love it, literally have everything I need to do most jobs in one easy to carry bag, no need for back and forth trips to the van
@AllenHart999
@AllenHart999 5 лет назад
@@HeatingGeek I notice you tagged me in a few different versions of my name in other videos 😂👍😂👍I am sure your channel will take over us both as you have much better content. 👍
@HeatingGeek
@HeatingGeek 5 лет назад
If I spell it wrong so will other people????? Then they find me :-) Im just winging it at the moment. I can fix boilers. Not sure I have the youtube thing yet. Hope you don't mind me hanging on your coattails.
@HeatingGeek
@HeatingGeek 5 лет назад
I will have a look on Sunday. Working tomorrow
@reghy2008
@reghy2008 5 лет назад
Another great video.. Thank you so much for sharing...
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks. :-)
@richardtittle351
@richardtittle351 2 года назад
Great video. I have the exact same boiler (over 20 years old but still ok) with gas valves that seem to be a bit sticky, they sometimes take a while to open or don't open at all. Can they be replaced and/or refurbished economically?
@normanboyes4983
@normanboyes4983 5 лет назад
Thank you for directing me to this video. Yes that is the same boiler that I own and I have had exactly the same problem, diagnosed and solved the same way. Its a pity you cannot remember why the other guy fitted a new gas valve assembly and pretty damning that he left the customer without a working boiler for such a simple problem no doubt after extracting the maximum £££ out if the customer. It is a pity that Gas Safe do not police this sort of activity and weed out the charlatans and incompetents.
@HeatingGeek
@HeatingGeek 5 лет назад
The customer didn't pay anymore than their monthly premium. The engineer has since told me the gas valve wouldn't adjust but after he replaced it, it wouldn't light. The only issue is the customer left without HTG and HW.
@carlton683
@carlton683 5 лет назад
Ok mate you do a good job I wish you lived in Birmingham as you could service my boiler thanks Tony
@HeatingGeek
@HeatingGeek 5 лет назад
There are loads of great engineers out there. Find one and use him.
@TheDs1969
@TheDs1969 4 года назад
Thanks for info on this boiler great all the best
@HeatingGeek
@HeatingGeek 4 года назад
No problem. Do you have this boiler?
@bobsempires
@bobsempires 5 лет назад
Thank god that on all latest boilers they are dropping pilot flame concept altogether, it's allways pain to maintain, had 2 boilers fail last week because of clogged pipe (that you cleaned in video). Great video as always.
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks a lot. Its a good picture too.
@normanboyes4983
@normanboyes4983 5 лет назад
If you assess that as a 'pain' good job you are not exposed to real engineering problems.
@bobsempires
@bobsempires 5 лет назад
@@normanboyes4983 Sure. In most instances, where gas quality is fine, these things last forever (best ive seen 10 years without maintanence). But in many specific cases where for some reason gas quality is bad i have to change/clean them every year or so. Pilot flame on big boilers is fine. However im questioning its design choice on smaller ones like junkers hidromax. Excess complication with many possible failiure points.
@normanboyes4983
@normanboyes4983 5 лет назад
RD Hey most guys when servicing boilers do not strip the pilot injector nozzle and clean it so with or without maintenance is the same situation. Of course the gas is always clean debris is introduced by new pipe installation.
@bobsempires
@bobsempires 5 лет назад
@@normanboyes4983 Oh it's worse than that. :) First of all, 2 junkers floor boilers in cascade installed 14ish years ago, they ran it on LPG gas at start but then now they switched it to NatGas 2 years ago. The reason why I had to clean injector for pilot flame was because there was literally no other way, pilot flame was so small it would never touch Ionization electrode, even after switching electrode to new one it would still fail to recognize the flame. After blowing injector and copper pipe with compressed air it started running fine again (bigger flame, reached ionization electrode). I believe the reason why injector got clogged with gray residue is something related to the way copper pipes react with NatGas that boiler companies don't want to talk about. They (Or some unwanted additive) produce these gray flakes that sometimes heavily clog rough filters before gas regulator. Still have to wait to determine the root cause of clogs but if it happens once every 2 years then obviously something is wrong in gas piping or filtering. However there may be something Ive failed to check or missed.
@gabrielsirghie
@gabrielsirghie 3 года назад
Thanks man, saved me few hundred £ probably 👍 cleaned and works perfect.
@HeatingGeek
@HeatingGeek 3 года назад
Great to hear!
@ThunderBolt-rm8cr
@ThunderBolt-rm8cr 5 лет назад
great work as always
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks. :-)
@stewartharrod1706
@stewartharrod1706 2 года назад
You are a boiler god 🙏
@carlton683
@carlton683 5 лет назад
Hi there just one point I thought it like the burner needed cleaning as the flame looked very orange many thanks for your videos keep them coming thanks again tony
@alanmurphy3584
@alanmurphy3584 5 лет назад
Anthony Stanley I thought the same until he reduced the burner pressure and it looked bang on
@HeatingGeek
@HeatingGeek 5 лет назад
It did look bad. But until its set up to the MI's I wouldn't clean anything. :-)
@mrman3509
@mrman3509 5 лет назад
Great video. Very helpful
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks. ;-)
@lazenbytim
@lazenbytim 4 года назад
Nice video again buddy.
@tayyabk92
@tayyabk92 5 лет назад
Great work 👍👍
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks. :-)
@TheYetty84
@TheYetty84 5 лет назад
I’ve been in this game 20 years now and think this is One of the easiest boilers to work on. If the top of the case is warm and not sparking go straight to the fan with zoom oil for a temp fix.
@HeatingGeek
@HeatingGeek 5 лет назад
Great boilers!!
@johnnysingh418
@johnnysingh418 5 лет назад
Another good video as always .my luck's in as I finally managed to get one off them injector tool" just bought one. Better check the euro .
@HeatingGeek
@HeatingGeek 5 лет назад
Check the euro??
@johnnysingh418
@johnnysingh418 5 лет назад
@@HeatingGeek I just felt lucky because I finally managed to get hold of the injector tool' as they sell out quickly. But no luck with the Euro lotto. Wish I had that tool two weeks ago" had a blocked injector on a gloworm spacesaver ' which I think caused the gas vale to go which was changed by br..... Gas under contract' but they never checked the injector.
@HeatingGeek
@HeatingGeek 5 лет назад
That sound about right. Pilot injectors are getting blocked all the time nowadays. Lack of proper servicing.
@jsmid
@jsmid 5 лет назад
You really do put some engineers to shame that was basic stuff a little cleaning! That customer obviously paid for another guy just to turn the gas off. Great job as always
@HeatingGeek
@HeatingGeek 5 лет назад
I think the original fault was more than that. Im a bit brain dead at the moment and cant remember what was going ok.
@jsmid
@jsmid 5 лет назад
@@HeatingGeek ohh my bad, I thought that was the only problem good job anyway 👌🏾😊
@HeatingGeek
@HeatingGeek 5 лет назад
Im sure it was more.
@HeatingGeek
@HeatingGeek 5 лет назад
Im sure it was more than that. :-)
@michaeltrimmer8899
@michaeltrimmer8899 4 месяца назад
Another great video
@HeatingGeek
@HeatingGeek 4 месяца назад
Thanks for taking the time to watch and comment. I do appreciate it. :-)
@keithbrueton
@keithbrueton 5 лет назад
Excellent video sound was not a problem
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks. It annoyed me that it rendered like that. I don't know why which is even worse. :-)
@thomasredrup4674
@thomasredrup4674 4 года назад
Hi, great video. Like the guides and tutorials. Im having trouble with one of these at the moment. Boiler is continuously relighting. Sometimes lights instantly, sometimes takes a lot of sparking to light. sometimes runs fine for 5-10 mins and stays lit after multiple restarts but then will go back to constantly lighting and going out and repeating. Case seal ok, combustion ok. New recon fan fitted. run out of ideas., maybe air pressure switch
@HeatingGeek
@HeatingGeek 4 года назад
Gas valve or PCB I reccon. :-)
@thomasredrup4674
@thomasredrup4674 4 года назад
HeatingGeek thanks to your video I worked it out. Had a blockage in one of the little holes in the injector. The pilot flame wasn’t good enough so wasn’t always making contact with the flame rectification probe! Thanks
@hvacgas5292
@hvacgas5292 5 лет назад
👍👍nice work.
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks :-)
@TomPalacki
@TomPalacki 5 лет назад
Great Video👍
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks. I can't find the issue with the audio at the moment but will have to redo it. Pain in the ass when I don't have a clue about this stuff.
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks. :-)
@scottwilliams1094
@scottwilliams1094 3 года назад
Great video 👍
@HeatingGeek
@HeatingGeek 3 года назад
Glad you enjoyed it. Thanks for watching it.
@naturelover_9211
@naturelover_9211 3 года назад
Brilliant video thank you.
@HeatingGeek
@HeatingGeek 3 года назад
Glad you enjoyed it. Thanks for watching. :-)
@amritbishokarma5660
@amritbishokarma5660 4 года назад
Hi my boiler when I 1st switch on manually it turns on for 1 or 2 after that it switches off it self. I can see small 🔥flame on standby. Please can you advise? Thank you
@HeatingGeek
@HeatingGeek 4 года назад
Does the boiler still tick?
@quadrantheatingelectricspl2907
Excellent video As ever, I am a big fan of yours. Don't miss a single video. Are you based in Watford ?
@HeatingGeek
@HeatingGeek 5 лет назад
No. I live in Cheshunt Hertfordshire. Work all over though.
@melvinanezi9236
@melvinanezi9236 5 лет назад
Logical diagnosis procedure.The objective is always to achieve and that is what you do 👍🏼
@andreag7530
@andreag7530 2 года назад
I have this but don’t know anything about them. It was serviced today but I wasn’t in when the guys came to do it so couldn’t ask but When heating water On a timer (I only have it on for 1 hour in the morning and 1 in the evening) the pilot light will come on , and stay on for a few minutes then switch off for about 5. It then comes back on for another couple mins then back off again. Is this meant to do that?
@tomsalmon4693
@tomsalmon4693 4 года назад
Nice work.
@HeatingGeek
@HeatingGeek 4 года назад
Thank you! Cheers!
@thpxs0554
@thpxs0554 5 лет назад
Excellent diagnostic procedure. In a step by step method. Applies to any faultfinding. A lot of people just say change this or that but that’s poor work.
@HeatingGeek
@HeatingGeek 5 лет назад
Glad you got through the sound issue. Thanks. Fault finding is all step by step and is the only way to be sure. :-)
@proteus1
@proteus1 5 лет назад
Adjusting the gas valve, you can open hot tap & turn cylinder stat up temp at same time to get readings.
@HeatingGeek
@HeatingGeek 5 лет назад
I don't understand? Sorry
@erdogan330
@erdogan330 2 года назад
great video thank you
@k20aa
@k20aa 5 лет назад
Good I work I too have had that fault so many times with them crap must just fail straight into it
@dzmalekvali1110
@dzmalekvali1110 5 лет назад
Thanks king
@zamanhaidar
@zamanhaidar Год назад
Thank you sir.
@HeatingGeek
@HeatingGeek Год назад
Most welcome
@kevinshales
@kevinshales 3 года назад
You just saved me a hundred quid minimum, blocked burner nozzle, went first time once cleaned...... here’s to a warm winter, huge thanks !!
@j.j8114
@j.j8114 Год назад
No words.... there's a good reason why you get a pro in to work on gas appliance's, yes to get it working, but mainly what your paying for is that it is safe, no gas leaks, no co leaks, case seal ok which is vital on gw ultimates. Not worth the risk to save a few quid...
@MSKChess
@MSKChess 5 лет назад
Solid logic, panic over, problem solved.
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks. :-) Nice easy one.
@johnboy1232
@johnboy1232 5 лет назад
Have one of these boilers and have worked on a lot of them over the years , this is a common occurrence. You have to be very careful how you disassemble the pipe especially if they have not been taken apart in a while ,they are very narrow and can shere around the olive .I have tried several methods to clean the pilot ,It seems a particular difficult one .The best results for me anyway is using a 12 volt tire compressor with the plastic cone shaped adapter cut down so it makes a good seal into the pilot injector This seems to work very well and there is no chance of reamering out the injector .The other common fault as the boilers get older is the PCB which usually shows as the boiler fan repeatedly stoping and starting. The other thing is I seem to remember a pilot restrictor that fits into the pipe at the valve end ,this can drop out when you are handling the pipe ,suspect that would show up straight away with the pilot picture. PS make sure you hang on tight to the injector when you start up the compressor!
@HeatingGeek
@HeatingGeek 5 лет назад
The pins clean them out really well. You do have to be careful not to damage the injector when cleaning.
@HeatingGeek
@HeatingGeek 5 лет назад
@steve french Maybe. :-)
@johnboy1232
@johnboy1232 5 лет назад
In the past I have tried boiling in a pan of hot water with not much success,The 12 volt compressor does work very well, I used a 12 v battery charger with male / female insulated connectors on both the outlet ends of the 12v side of the battery charger and the 12v wires going to the compressor .To make more portable for inside use. The other thing I used it for was clearing sludge blockages in microbore , disconnecting valve end from rad connecting suitable fittings and I had a piece of 8mm insertion tube that fitted tightly into the thumb valve of the compressor ,turn on the rad valve , turn on the compressor for 5sec ,then remove the end of the insertion tube into a bowl and with a bit of luck the sludge runs out , repeate if required. Of course there is a chance you push the sludge somewhere else but that never happened to me . Microbore is not as common today as it was in my time .but I can assure you this little dodge saved me hours and hours .very useful for where the microbore come off a 4 way inline manifold and sludge tended to settle blocking of the bottom tube.
@mmack3286
@mmack3286 4 года назад
I would love to see you service a Intergas boiler
@HeatingGeek
@HeatingGeek 4 года назад
Why? :-)
@robert500s
@robert500s 5 лет назад
Who’s downvoting this ? Have a word with yourself. Much appreciated as always bro
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks. I appreciate it. Cant fix the sound at the moment.
@hankattack
@hankattack 5 лет назад
Maybe people who think there shouldn’t be videos on RU-vid encouraging people who don’t know what they’re doing to mess with gas appliances when being untrained to do so? Do anything for them views tho.
@heatservicebwcuk1545
@heatservicebwcuk1545 5 лет назад
Chris Freeman he makes them to help other engineers out. If people want to dice with it then they will anyway. Ollie has never said on any videos to have a go yourself save some money infact the opposite
@alanmurphy3584
@alanmurphy3584 5 лет назад
Chris Freeman crawl back down your hole you helmet
@heatservicebwcuk1545
@heatservicebwcuk1545 5 лет назад
Chris Freeman don’t agree with you. Why are you watching can I ask ?
@bertybollocks
@bertybollocks 5 лет назад
Another top vid besides the audio but hey ho, could I ask u in the near future if poss and you have time could you do a vid on a boiler electric preliminary checks before a gas service thanks again man love your vids very informative too man 👍🏻👍🏻👍🏻
@HeatingGeek
@HeatingGeek 5 лет назад
What, like safe isolation etc?
@bertybollocks
@bertybollocks 5 лет назад
HeatingGeek yes exactly if poss like thanks
@bertybollocks
@bertybollocks 5 лет назад
Like the earth continuity. Safeisolation,polarity checks just theorelim checks before agas safety inspection on the boiler stuff like that
@HeatingGeek
@HeatingGeek 5 лет назад
@@bertybollocks Ok I will try and do it but it won't be soon.
@bertybollocks
@bertybollocks 5 лет назад
HeatingGeek mate anytime u can like Would be much appreciated thanks
@recall2880
@recall2880 2 года назад
We have one of these and every time it lights it makes two loud clicks and clunks. I’ve been told it’s normal but why would a boiler lighting be so loud?
@CarlosArruda77
@CarlosArruda77 Год назад
Great video but as I have seen your analizer on Natural Gas, that flame picture yellow shouldn't it be blue? The meter man sees that and that's a meter capped off! lol. Great insight on how to roubleshoot this.
@HeatingGeek
@HeatingGeek Год назад
The flame is only yellow because the case is off. :-) Once on you can see the flame goes blue
@CarlosArruda77
@CarlosArruda77 Год назад
@@HeatingGeek That did make me wonder. Too much oxygen being mixed with the gas? Much appreciated for the reply mate. Have a good weekend.
@colinford7427
@colinford7427 4 года назад
Did you check to see how many rads were on the system before you decided to adjust the valve to 10.8mb as I noticed it had the option of max 12.7 for 60.000 btu or doesn't it really matter as its only 5.000 difference, just wondering im not picking holes as I like your work,
@HeatingGeek
@HeatingGeek 4 года назад
If you look at the data badge it was set up for this burner pressure when the houses were built. :-) Little red arrow.
@colinford7427
@colinford7427 4 года назад
@@HeatingGeek Oh thanks for that I never noticed,
@hikmatmakdasi9256
@hikmatmakdasi9256 4 года назад
I have same boiler when switch on it will works continually for 15 minute then it will turn of for around 2minute and on for around 5 minute and keep on and off like that till the water get worm and the cylinder thermostats switch the boiler off is that normal or dose that mean the flame is too high of the pressure more than 10.8
@HeatingGeek
@HeatingGeek 4 года назад
That sounds normal for that type of boiler.
@hikmatmakdasi9256
@hikmatmakdasi9256 4 года назад
@@HeatingGeek thanks alot
@HeatingGeek
@HeatingGeek 4 года назад
@@hikmatmakdasi9256 No problem
@tonyjarv
@tonyjarv 5 лет назад
Next level shit this, I’ve fixed this a hundred times but never been in the hot burner pressure knowledge bracket, Did I read your teaching if so where at?
@HeatingGeek
@HeatingGeek 5 лет назад
Just doing it every day since I was 16.
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks :-)
@HS-vz8rj
@HS-vz8rj 3 года назад
Dear Heating Geek Need some advice pls....my boiler glowworm ultimate 40bf...if fires up for 5 minutes and then goes back to pilot light...and then after 15min it fires up again for 5mins...pls help...what could be the culprit....the thermostat are all on full.....not sure why it keeps shutting after 5minutes
@HeatingGeek
@HeatingGeek 3 года назад
Blocked, slow pump, air in system, Just a few for you there.
@normanboyes4983
@normanboyes4983 3 года назад
Boiler water return stat set too low?
@robertskinner4148
@robertskinner4148 5 лет назад
I liked this video "STRAIGHT AWAY"
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks. The sound is sh#$ and I don't know why. ;-)
@tonycosgrove6433
@tonycosgrove6433 5 лет назад
Nice video a apart from the sound.
@HeatingGeek
@HeatingGeek 5 лет назад
Yeah sorry. Still don't know why. Only becomes apparent once rendered. The sound is good in the editing software.
@jackhoskins722
@jackhoskins722 5 лет назад
Great video if we the crackle effect
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks :-)
@anthonynewcome128
@anthonynewcome128 5 лет назад
glow worm logic....use one nut and one wing nut.......would love to have been at that meeting.....lol
@HeatingGeek
@HeatingGeek 5 лет назад
I think its because the access is tight so they changed it. Weird though,
@benjaminfrost4363
@benjaminfrost4363 5 лет назад
did someone fit the gas valve because the pilot injector was blocked?
@HeatingGeek
@HeatingGeek 5 лет назад
I cant remember now. I think there was more too it than that.
@MrDazman56
@MrDazman56 3 года назад
I have a 21 year old glowworm ultimate and is wasn't heating up called gas man round and all it needed was the pilot light cleaning it was blocked. Soaked in hot water and it worked fine just charged me call out fee.
@benjaminfrost4363
@benjaminfrost4363 5 лет назад
was the electrode cracked mate?
@HeatingGeek
@HeatingGeek 5 лет назад
No it looked in very good condition to me.
@ek6868
@ek6868 5 лет назад
👌
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks. ;-)
@tomstrutton4351
@tomstrutton4351 5 лет назад
Where's the link? Can't find it..... is that how we can support your Chanel ?
@HeatingGeek
@HeatingGeek 5 лет назад
www.ebay.co.uk/itm/333049011957 Its in the description??? I think...
@HeatingGeek
@HeatingGeek 5 лет назад
Every little helps :-)
@jazzmiah8953
@jazzmiah8953 5 лет назад
What paste did u use?
@martingreen6410
@martingreen6410 5 лет назад
Looks like jet blue plus
@HeatingGeek
@HeatingGeek 5 лет назад
Yes Jet Blue Plus. Doesn't spill!!
@martingreen6410
@martingreen6410 5 лет назад
@@HeatingGeek This takes Me back. I used to work for glowworm and service repair there range of products. Popular back then was the hot water express combi. Changed its name to the swift flow. I used to put injectors / jets in a cup of hot water then blow through or replace. Especially on Lpg where the gas was attracted to the brass👍. Good fault finding very methodical.
@HeatingGeek
@HeatingGeek 5 лет назад
Thanks. :-) I hated swiftflows!!! Glad there gone.
@inityo
@inityo 2 года назад
How do you increase the pressure?
@HeatingGeek
@HeatingGeek 2 года назад
What pressure?
@inityo
@inityo 2 года назад
@@HeatingGeek boiler pressure like on new boilers you just open the valves. I feel that my hot water has very low pressure but the temperature is extremely hot with this boiler
@HeatingGeek
@HeatingGeek 2 года назад
@@inityo Unfortunately the pressure you talk about on new boilers is the pressure within the heating system. Not at all related to the hot water pressure. You probably have a hot water cylinder filled via a tank in your loft. The height difference between this tank and the hot water outlet you are using is what gives you the pressure of your hot water. I hope this explains it for you.
@inityo
@inityo 2 года назад
@@HeatingGeek so there is no way to control the pressure ? Do these boilers require you to keep filling a tank ?
@HeatingGeek
@HeatingGeek 2 года назад
@@inityo The tank fills with a ball valve. :-)
@ArksE8
@ArksE8 Год назад
Pilot tube snapped today. Gas valve side after I replaced the gas valve.
@HeatingGeek
@HeatingGeek 4 месяца назад
Sorry I didn’t respond to this comment. I didn’t see it in my feed. :-(
@darrenjowett8032
@darrenjowett8032 Год назад
Can you come and fix mine I’m in leeds
@HeatingGeek
@HeatingGeek 4 месяца назад
Sorry I didn’t respond to this comment. I didn’t see it in my feed. :-(
@mmack3286
@mmack3286 4 года назад
Nice old boiler
@HeatingGeek
@HeatingGeek 4 года назад
I agree. One of the best. :-)
@jamiemerchant7933
@jamiemerchant7933 5 лет назад
Surprised that a really knowledgable engineer like yourself would use any sort of tool to clean an injector
@HeatingGeek
@HeatingGeek 5 лет назад
I knew someone would eventually say that. I would think that too if I had done done it hundreds of times. British Gas allow their engineers to clean pilot injectors with a similar tool. Im not reaming it out. Just clearing the hole. If I refitted the injector and the flame was elongated I would replace the injector. This isn't making the hole any bigger, just clearing it. Give it a go. If it works, boiler fixed. If it doesn't boiler STILL broken. (nothing to loose) :-) Thanks for watching and commenting. :-)
@jamiemerchant3327
@jamiemerchant3327 5 лет назад
HeatingGeek Thanks for your reply It’s not a criticism I really enjoy your videos your knowledge of electronics is 2nd to none And even after for 41 years in this industry I’m still learning but I’ve never felt the need to put any sort of object through an injector hole I just drop it in boiling water for a couple of minutes and then blow it through that seems to work without the risk of enlarging the whole Keep up the good work as a say you are a top engineer thanks
@HeatingGeek
@HeatingGeek 5 лет назад
@@jamiemerchant3327 I didn't take it as a criticism. It exactly what I believed until recently. I haven't enlarged one yet but that may happen. I have never tried boiling water tbh. Tried air duster and WD40 but didn't find it very effective. I will try boiling water on the next one and see how it works. :-)
@davidmarsden8868
@davidmarsden8868 3 года назад
Can’t believe the 1st engineer couldn’t diagnose that
@HeatingGeek
@HeatingGeek 3 года назад
Lots of newer engineers would miss this. They don't see these boilers very much. :-)
@davidmarsden8868
@davidmarsden8868 3 года назад
@@HeatingGeek true, I enjoy working on the older stutt Got an old concord to look at tomorrow
@darrellbutler8585
@darrellbutler8585 Год назад
Was gas turned off all this time lol
@jsmid
@jsmid 5 лет назад
I thought sound was just me
@HeatingGeek
@HeatingGeek 5 лет назад
unfortunately not. :-(
@D_pawson
@D_pawson 5 лет назад
Repair ?? or service🤔😂😂😂
@HeatingGeek
@HeatingGeek 5 лет назад
Errr... Repair kinda... ;-)
@TheBendalina
@TheBendalina 4 года назад
the first engineer changed the valve but couldn't clean a pilot injector? He needs to be better trained.
@HeatingGeek
@HeatingGeek 4 года назад
indeed. :-)
@andreag7530
@andreag7530 2 года назад
I have this but don’t know anything about them. It was serviced today but I wasn’t in when the guys came to do it so couldn’t ask but When heating water On a timer (I only have it on for 1 hour in the morning and 1 in the evening) the pilot light will come on , and stay on for a few minutes then switch off for about 5. It then comes back on for another couple mins then back off again. Is this meant to do that?
Далее
Faulty thermocouple Glowworm spacesaver
3:47
Просмотров 2,3 тыс.
Boiler Broke Down - Fan Fixed for only €2
16:48
Просмотров 1,7 тыс.
НАШЛА У СЕСТРЫ СЕКРЕТИК
00:36
Просмотров 298 тыс.
Я читаю переписки сына
00:18
Просмотров 597 тыс.
Gloworm Micron 40 FF flashing burner light
1:30
Просмотров 25 тыс.
How To Replace a Fan Glowworm Ultimate 40FF
15:19
Просмотров 2,2 тыс.