This was a walk in cooler that had been down for a few days. I found several issues with the unit, the unit had a bad contactor, compressor, txv, ect. I got the unit up and running the same day.
To support my videos please visit either of the links below
For Patreon / hvacrvideos
For Streamlabs streamlabs.com...
TOOL LINKS
Samsung Tab A amzn.to/2IZxSKY
Ottor Box case amzn.to/2ZWYIZZ
Fieldpiece JobLink probes amzn.to/2XeiKNI
For Optimizing my videos I use Tube Buddy
www.tubebuddy....
Please consider subscribing to my channel and turning on the notification bell by clicking this link goo.gl/H4Nvob
Social Media
Facebook / hvacr-videos. .
Instagram / hvacrvideos
For any inquiries please contact me at hvacrvideos@gmail.com

Опубликовано:

 

30 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 557   
@joevinski1
@joevinski1 5 лет назад
Haven’t watched it yet but I know it’s gonna be great !!! Can’t wait to explore with you Chris !!!
@JjMn1000
@JjMn1000 3 года назад
Yes
@whatevernamegoeshere3644
@whatevernamegoeshere3644 4 года назад
*click, bang, literal internal screeching* "Well that compressor sounds healthy!" That made me chuckle not gonna lie man
@joea2274
@joea2274 4 года назад
Oh come on that's how the new ones sound LoL
@edwardmyers1746
@edwardmyers1746 4 года назад
@@joea2274 yes! Gotta break in the internal components :)
@sherwinanago9106
@sherwinanago9106 4 года назад
👍👍❤❤
@charadremur333
@charadremur333 4 года назад
@@edwardmyers1746 or just break,
@prophetfgsm
@prophetfgsm 5 лет назад
That's a magic recovery tank. You can keep reusing it and it never fills up
@SombraLocs
@SombraLocs 5 лет назад
😂😂😂😂😂😂
@kelvincardona2397
@kelvincardona2397 3 года назад
Lol
@murfdog19
@murfdog19 5 лет назад
Don't you just love when you fix the issue and find another issue, then fix that issue and find another issue?
@lobehold2263
@lobehold2263 5 лет назад
Customer loves it even more I bet
@mikeodwyer7514
@mikeodwyer7514 5 лет назад
Great fun writing the bill , just gets bigger and bigger and bigger ! Might have been easier to price a new outdoor unit !! Great job done in the end all the same ! Love ur videos keep up the great work !
@jac01055
@jac01055 5 лет назад
I’m a software engineer and I feel this 😂
@Transit_Biker
@Transit_Biker 5 лет назад
Murphy's law? :D
@redeye619
@redeye619 4 года назад
That's the fun part lol
@rossr4222
@rossr4222 5 лет назад
I’ve learned quite a few things from you. 7 years in resi, now I’ve moved into commercial. Love you videos, best hvac vids on youtube
@proamlito07
@proamlito07 5 лет назад
Agree
@milotorres6894
@milotorres6894 4 года назад
Insights are spot on always..
@mojoemurphy
@mojoemurphy 5 лет назад
Ah, the sound of a screaming compressor
@2centsbear638
@2centsbear638 Год назад
A sound you never forget
@ryuranzou
@ryuranzou 4 года назад
Can really appreciate the wide skillset needed to do HVAC repair after watching this. I also love how thorough you are with diagnosing problems so the customer doesn't run into other problems right away.
@cityscene121
@cityscene121 5 лет назад
As usual, I was cemented in place until the end of this video. Your ability to express your investigative thought process is a great bonus to your videos. Your analytical process and deductions based on gauge readings are thorough and insightful, something I'm able to recognize at this point is a must-have skill. I appreciate the time spent without comment on soldering your joints and the inspection time. I think the point was made that taking your time will save on backtracking, and preventive measures to protect components during brazing is non-negotiable. Finally, the operating analysis, after all repairs were made is a great bonus to your videos. Thanks for bringing us along. Never a wasted moment.
@alexzapata692
@alexzapata692 4 года назад
OMG, he forgot to purge the hose before recovering the refrigerant to his cylinder. My first boss would've lectured me lol. Chris how long does it typically take you, changing a major component like the compressor along with the other components, filter drier, sight glass etc? Your video is edited for 55 mins but how much of the editing do you edit. Do you teleport to the supply house to get the compressor and the misc stuff? Are you some kind cyborg human like the terminator that terminates hvac equipment and doesnt need to eat lunch or take water breaks? Lol
@HVACRVIDEOS
@HVACRVIDEOS 4 года назад
This entire job took 10 hours including drive time, I will be going live on RU-vid this evening 11/25/19 @ 5:PM (pacific time) to discuss my most recent uploads, and answer questions from email’s , RU-vid comments, and the Live chat come on over and check it out if you can. ru-vid.comlive
@chottom
@chottom 5 лет назад
I understand it's sun protection, but if i saw a guy dressed like that on a roof with a torch i wouldn't presume he is repairing something 😄
@michaelt.3805
@michaelt.3805 3 года назад
I am Network Engineer, not an A/C guy, but after watching your videos, I have a whole new respect for what you guys go through and all the techniques you use to troubleshoot. Keep up the great work.
@2centsbear638
@2centsbear638 Год назад
Good thing you specified 'Network', because many of the technician guys especially old-timers have much disdain for refrigeration engineers 😅
@michaeldomansky8497
@michaeldomansky8497 5 лет назад
You, sir, are a real technician worthy of the title! As well as being a talented craftsman who cares about the product. Mega Kudos!
@dcj2045
@dcj2045 5 лет назад
I don’t get it, you changed almost the whole unit component; why not just replaced the unit itself?
@Jpalms123
@Jpalms123 5 лет назад
think about what you would have to charge a customer for that after you rent a lift or crane(it turns into a bigger project than just a rope). if the pieces are still made and the customer approves the repairs why get greedy and try to charge them more? theyll turn around and probably go for other bids and more than likely go with who they pick for that for future work.
@primetime758
@primetime758 5 лет назад
@@Jpalms123 true very true but it never hurts giving them... THE BEST OPTION brand new unit yes.. it would cost much more... but ? it would be faster.. especially if he can buy an indoor unit and put it on the roof and just build a dog house from sheet metal... or go for plan B repair whats up there
@anotheronebitesthedust246
@anotheronebitesthedust246 4 года назад
@@primetime758 it's always better to give the costumer look your unit it's old I can fix it. But I would recommend getting a new unit this one may failed in the future ( 6 month less of more) it's your option
@dondesnoo1771
@dondesnoo1771 4 года назад
Wouldn't be a good video 😉
@Badtxv
@Badtxv 4 года назад
I just made the transition from commercial/industrial hvac to refrigeration and I'm addicted to your videos I've learned more about refrigeration by watching a few hours of your videos than I have in my entire career.
@HVACRVIDEOS
@HVACRVIDEOS 4 года назад
Wow thanks for the nice words and thanks for the channel support! I will be going live on RU-vid this evening 12/30/19 @5:PM (pacific time) to discuss my most recent uploads and answer questions from emails and the chat, come check it out if you can ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-XNnsDZUitZQ.html
@elkumino
@elkumino 5 лет назад
I know you measured the pan you put the oil in and then subtracted it, but it might be easier if you just zero it out with the empty pan on. Then, it's just weighing the oil
@huntervelicky7502
@huntervelicky7502 4 года назад
i wanna work with this guy so bad i would do it for free and i'm not even remotely joking
@dougshakell8003
@dougshakell8003 4 года назад
I am in Ontario can come work with me I could teach u the right ways to repair this simple equipment
@Wolfhound.
@Wolfhound. 5 лет назад
wow talk about digging your way into a hole so the compressor died sending the pressure switch off and that made the switch go on and off till it failed so you get to dig your way into a literal cluster f
@larryhamel7662
@larryhamel7662 3 года назад
by pass dosnt mean bad comp its hi pressure because txv bad contactor bad couse short cycling comp could be bad but i would have got gas out see if comes out of by pass if did would tell u restriiction just a thought we do our best and try to do whats right
@davidperry4013
@davidperry4013 5 лет назад
That bad compressor sounded like a sci-fi horror movie scene.
@EnderMalcolm
@EnderMalcolm 4 года назад
Kinda reminds me of a Warp Core Breech on USS Voyager.
@xishxander8510
@xishxander8510 5 лет назад
Legend. I'm 2yrs deep (mostly residential) and I've been running commercial for 3 months. Just saw my first molitron on call yesterday. Entire career has been trial by fire to this point, but I'm still here. I've watched many of your videos, but this is exceptionally beautiful. Workflow, procedure, troubleshooting, it's all here. You're a true professional. THANK YOU SO MUCH. I finally got a day off and watching this video is the most productive thing I will probably do today. The editing on this video is perfect and the number of topics you discussed is absolutely mind boggling, and yet, you make it seem almost effortless. As a green guy cutting their teeth in the field finding reliable mentors is a joke, so I am writing this to express my sincere gratitude for taking the time and putting in the effort to create such an enriching educational experience. You are the best! Thank you!
@HVACRVIDEOS
@HVACRVIDEOS 5 лет назад
I will be going Live on RU-vid tonight 8/12/19 at 5:PM west coast time to discuss my recent uploads and answer questions from emails,the chat, and RU-vid comments come check it out if you can ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-Os9rV7YWjzo.html
@stephenphillips8692
@stephenphillips8692 4 года назад
My wife wonders why I was on a service call for 9 hours!!
@memyselfandifarmer
@memyselfandifarmer 5 лет назад
No matter what, I vacuum out the tank for a deep vacuum.
@memyselfandifarmer
@memyselfandifarmer 5 лет назад
Wear gloves while working with refrigerant, it's cold. Frost bite blows.
@dandfgarage986
@dandfgarage986 4 года назад
I love how he does everything right. Unlike MY boss
@HVACRVIDEOS
@HVACRVIDEOS 4 года назад
I'm not perfect
@dandfgarage986
@dandfgarage986 4 года назад
HVACR VIDEOS my boss does not do anything right. He replaced a compressor with me and there was a WHOLE BUNCH of fried wires and he just said “leave it” he also throws away the filter covers for ac units. He’s very bad
@dandfgarage986
@dandfgarage986 4 года назад
paul beenis how about you mind your own business. I have no idea why YOU would care you low life. Leave me alone you hater. I did nothing wrong. I’m talking with somebody else NOT including you. And your the one that’s pity. You dummy. I would do things better then you would any day.
@plasmachicken
@plasmachicken 4 года назад
@@dandfgarage986 no you would not
@dandfgarage986
@dandfgarage986 4 года назад
PLASMA chicken yeah the fuck I would.
@joevinski1
@joevinski1 5 лет назад
Lol love the “some peoples kids “ hahahahaha
@roberthvacpro
@roberthvacpro 5 лет назад
At what point do you change the whole condenser? The only thing left is the coil
@HVACRVIDEOS
@HVACRVIDEOS 5 лет назад
This was a time sensitive issue a new condenser would have required a crane and we didn't have time for that, this happens alot in restaurant work, sometimes you gotta get it fixed
@HVACRVIDEOS
@HVACRVIDEOS 5 лет назад
I will discuss this on my stream tonight, I will be going Live on RU-vid tonight 8/12/19 at 5:PM west coast time to discuss my recent uploads and answer questions from emails,the chat, and RU-vid comments come check it out if you can ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-Os9rV7YWjzo.html
@TheNemosdaddy
@TheNemosdaddy 5 лет назад
Ty for taking the time to walk through the whole replacement. Although not my trade, I enjoy seeing what you go through to repair things properly. Stay cool in that heat!
@HVACRVIDEOS
@HVACRVIDEOS 5 лет назад
I will be going Live on RU-vid tonight 8/12/19 at 5:PM west coast time to discuss my recent uploads and answer questions from emails,the chat, and RU-vid comments come check it out if you can ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-Os9rV7YWjzo.html
@cranium33333
@cranium33333 5 лет назад
High pressure switch designed to save the unit. Actually ends up in this case destroying the unit.
@HVACRVIDEOS
@HVACRVIDEOS 5 лет назад
Yep
@dougshakell8003
@dougshakell8003 4 года назад
Nothing was wrong with hp control. With a mic find condenser a restriction or underfeeding txv will cause exessive pressure. It was doing its job.large compressors have a time delay to prevent short cycling caused by unacceptable conditions.the hp switch cycling burnt contactor coil.
@jonathanschulz5841
@jonathanschulz5841 4 года назад
Rich Davis high pressure switches with MANUAL RESETS save units, the auto resets are the ones that kill. Only HP switch i will install is manual reset
@edwardwilliams8261
@edwardwilliams8261 4 года назад
I haven’t watched the whole video yet but it seems that if it’s short cycling on the high pressure switch and when you bypass it your compressor internal relief valve opens then you have a pretty bad restriction in the system. How was the drier that you replaced?
@steveblake8766
@steveblake8766 5 лет назад
#203 Thumbs up! Love these long videos
@MEATZBMX
@MEATZBMX 5 лет назад
I had a leaking recovery tank a few weeks back. Super annoying
@HVACRVIDEOS
@HVACRVIDEOS 5 лет назад
I will be going Live on RU-vid tonight 8/12/19 at 5:PM west coast time to discuss my recent uploads and answer questions from emails,the chat, and RU-vid comments come check it out if you can ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-Os9rV7YWjzo.html
@HVACRDUDE
@HVACRDUDE 5 лет назад
Loving the longer videos! Badass repair! Have you tried to point the recovery machine fan on the tank? It helps alot..don't even pull out my moleculizer anymore..sweet little trick
@mychoclabwinston
@mychoclabwinston 5 лет назад
Chris you need a helper, to get all that stuff on and off the roof
@mccutcheonservicesllc81
@mccutcheonservicesllc81 5 лет назад
Nice job 👍 I'm a little disappointed that you didn't show that you verified the compressor was a 3-phase before you installed. 🤣
@gregmercil3968
@gregmercil3968 4 года назад
"We'll get this guy pulled out, and the new one set in, and we won't open the plugs until we pipe it..." ***that's what she said*** Sorry I had to. 😂😂😂
@gadgetroyster
@gadgetroyster 4 года назад
I have been retired about 10 years and never upgraded to those "Fieldpiece" gauges as they were pretty new at the time. Sure wish I had sprung for the superior tools. Walking up and down from the roof to the evap section sure became a pain in the ass.
@hddm3
@hddm3 5 лет назад
Man I wish I understood more of what your saying. Wow your a true professional man.
@HVACRVIDEOS
@HVACRVIDEOS 5 лет назад
I will be going Live on RU-vid tonight 8/12/19 at 5:PM west coast time to discuss my recent uploads and answer questions from emails,the chat, and RU-vid comments come check it out if you can ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-Os9rV7YWjzo.html
@squirrelwood8008
@squirrelwood8008 Год назад
Binge watching the older videos here.... another walk in cooler that's not walkin' :)
@thomasmleahy6218
@thomasmleahy6218 Месяц назад
Yes, the walk-in cooler.
@skywave12
@skywave12 5 лет назад
80 % Electrical 20% Refer. hehe
@JeffreyGroves
@JeffreyGroves 4 года назад
I can tell that you may not have had any climbing experience since you step on your ropes. Then again, you’re not relying on that rope to carry your body weight. Stepping on the rope forces dirt and grit into the rope which causes them to wear rapidly under tension.
@K7DFA
@K7DFA 4 года назад
Not only that, but rope doesn't really provide a good surface for walking on (I'm a former combat engineer, and our instructors drill that part about the rope wearing out more rapidly into the trainees brains), the other part becomes obvious when you end up taking a pratfall (or two), while stepping on a rope!.
@leonvivieros6440
@leonvivieros6440 5 лет назад
I was always told not to sweat out filters because if moisture was in the system the heat to that filter would release it back to the system. What you guys think?
@HVACRVIDEOS
@HVACRVIDEOS 5 лет назад
I will discuss this more on my stream tonight, I will be going Live on RU-vid tonight 8/12/19 at 5:PM west coast time to discuss my recent uploads and answer questions from emails,the chat, and RU-vid comments come check it out if you can ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-Os9rV7YWjzo.html
@milwaukeephil2548
@milwaukeephil2548 4 года назад
You were concerned about overcharging this unit, yet you have a receiver that at 80% max fill capacity there would be plenty of room to add 2# over full charge. My guess that system could handle 10#+. On headmaster controlled units in cold environments, I usually charge @ 80% receiver capacity. I too put my hat in the ring for StayBrite 8 on liquid lines and suction lines. I reserve braze for discharge lines only. I’ve never had any issues. I’m more concerned about damaging components from overheating them than reaching any burst points. You can usually skip the nitrogen flow too with solder. Curious on your thoughts.
@hvac01453
@hvac01453 4 года назад
thats 45 fluid ounces by volume, not 45 ounces by weight. They are different.
@jeffhall2958
@jeffhall2958 5 лет назад
Nice job on everything. I like watching young people in this field, when they discover the process of troubleshooting and the somewhat instant gratification it gives. Nothing is better than solving a puzzle no one else can solve. It's better than drugs, because you can get your "fix", simply by going to work, being thorough, and doing a good professional job. BTW, you may want to put some of that heat-sink on the liquid line service valve in the future, it has teflon and o-ring seals in it. Just saying. :D Great job! Keep doing these vids and posting them. You're going to find new ways of doing things as you get older and better at this job. Keep sharing them. Good luck and keep up the good work!
@JustMe-tz2lh
@JustMe-tz2lh 4 года назад
This is almost like Minecraft.
@brianpiper3188
@brianpiper3188 5 лет назад
Thank you for another great video! As someone who used to be a frozen manager in a grocery store and now getting to see the technical side of HVACR systems, maintaining routine temp logs are absolutely no joke.
@HVACRVIDEOS
@HVACRVIDEOS 5 лет назад
I will be going Live on RU-vid tonight 8/12/19 at 5:PM west coast time to discuss my recent uploads and answer questions from emails,the chat, and RU-vid comments come check it out if you can ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-Os9rV7YWjzo.html
@larryhamel7662
@larryhamel7662 3 года назад
if txv was bad stuck closed probly y in by pass when in by pass
@hvac01453
@hvac01453 5 лет назад
I noted you burnt your sight glass like I did using that stuff in a plastic Jar. I may considering using staybrite 8 in the future, just for sign glasses. I know supply houses useto carry them with 6" extended ends to help with that issue. That oil looked black, why didn't you use an HH drier?
@primetime758
@primetime758 4 года назад
using an HH filter is for only when the system is grounded or Flooded
@hvac01453
@hvac01453 4 года назад
@@primetime758 the activated charcoal sweetens the oil and if the system becomes acidic later on, it helps keep the oil from burning up the windings. Cheap insurance. If the oil is black, its burnt!
@primetime758
@primetime758 4 года назад
@@hvac01453 if the oil is Black that doesn't mean its necessarily burnt.. but if in certain cases as this one ... the compressor is back leaking means the oil came to a point of no lubrication anymore.. so i would of put a normal Suction filter .. not HH
@commanderosis435
@commanderosis435 5 лет назад
I'm glad to see I'm not the only one that checks power even with the exop down. Getting electrocuted scares the crap out of me.
@stillthakoolest
@stillthakoolest 5 лет назад
Just curious why you chose to replace the fan motors at this call? Did you suspect they may be bad?
@ickipoo
@ickipoo 5 лет назад
I think he explains at the end that he thought it might have been high condenser temperatures that killed the compressor?
@throttlebottle5906
@throttlebottle5906 5 лет назад
sounded like it went straight into over pressure and bypassing with the high pressure switch unhooked, that made me think major restriction somewhere before your gauge, then again, without seeing/knowing the whole system layout I'm probably shooting blindfolded in the dark lol
@stephennichols4815
@stephennichols4815 8 месяцев назад
Wasn't you decreasing the super heat and I always check the discharge line temperature also even though the high pressure was looking close other problems causing a high discharge temperature will overheat the discharge valves and breaks easily with hifh pressure but I enjoy watching your videos even though I'm retired after 40 years in the HVAC INDUSTRY iearn and find the new technology very interesting and you have good work ethics and pride in what you do
@alsavage1
@alsavage1 Год назад
Hmmm. @41:00 you seem to be confusing ounces avoirdupois (that is, the weight) with fluid ounces (that is, volume). Liquids are almost always measured via their volume; solids are usually measured via weight. "Ounce" can refer to either measurement system, but they are not the same. So, saying that the mfgr specs "40 ounces" of a liquid (volume) doesn't mean that you can compare that to the weight of 35 oz. of oil. Bear in mind, phase-change refrigerants _are_ measured by weight, so you're used to thinking in that metric.
@Super10091974
@Super10091974 5 лет назад
Love your videos!!!!! Do job link probes operates in such low temps?
@HVACRVIDEOS
@HVACRVIDEOS 5 лет назад
No they actually dont work well past 0 degrees.
@HVACRVIDEOS
@HVACRVIDEOS 5 лет назад
I will be going Live on RU-vid tonight 8/12/19 at 5:PM west coast time to discuss my recent uploads and answer questions from emails,the chat, and RU-vid comments come check it out if you can ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-Os9rV7YWjzo.html
@vipleather
@vipleather 5 лет назад
Oh boy I remember the smell that comes with that. Kinda burning chlorine smell.
@throttlebottle5906
@throttlebottle5906 5 лет назад
uhhh, that's called Phosgene gas, make sure you breathe deep? /end sarcasm ill just leave this here... en.wikipedia.org/wiki/Phosgene
@tarlvinrandall7009
@tarlvinrandall7009 5 лет назад
Dude you are inspiring. Thorough trouble shooting at its best. Most service techs just want to get in and get out for fast money, excellent job.
@douro20
@douro20 4 года назад
Is that unit only serving the one evap? If that's the case I don't see any reason why it should be a pressure controlled unit. Does Worthington make recovery cylinders?
@pavelkolp
@pavelkolp 5 лет назад
Hey Chris, were did you do your training for HVACR? Your knowledge is amazing!
@HVACRVIDEOS
@HVACRVIDEOS 5 лет назад
I did attend a community college hvacr program but other than that I just did a bunch of research and Im a very curious person, I will be going live this evening 9-2-19 @ 5:PM (pacific time) to discuss my most recent uploads and answer questions from emails, the live chat, and RU-vid comments. Come on over and check it out if you can! ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-n540KJDIk6A.html
@HansakaChaturanga
@HansakaChaturanga 3 года назад
i guess TXV bulb was not touch the pipe properly ,so didnt sens suction temp correctly, coz of that valve not operate properly, then some tech adjust the TXV, refrigerant got extra block, compressor valve receive over weight and internal bypass occur, HP switch got fault itself due to continue open and closed , comp contactor got fault due to comp on and off continuelly coz no time delay or manual reset option. if ever i saw comp bypass first i remove refrigerant ,make 0 psi, on the unit charge refrigerant slowly till again by pass, and the note down the refrigerant weight and pressure and comp AMP at which point its bypass, off the unit reduce pressure little, on unit again, while running under pressure check pipe line is there any unusual temp drop like after condensor , after filter drier, after Liquid receiver, after sutoff valve, if found it mean that part is blocking refrigerant, if not found any , check TXV, make heat the bulb and check open close opration, check TXV adjustment, use screwdriver as a stethoscope and check refrigerant passing sound before and after the TXV, and if sound not constant open and check TXV strainer, could be block, if no unusual pressure and temp drop or refrigerant block, and still comp cant hold the appopriate refrigerant volume without bypass, ill go to final decision as comp is mecanically fault.
@JaegerWrenching
@JaegerWrenching 4 года назад
It's awesome to see you run through issues using deductive reasoning. That is what makes a great engine tuner as well. Probably 80% of the time i get a vehicle in that "just needs a tune" i have to fix issues that guys thought i could just "tune out." What most people lack is the overall understanding of the entire process, whether it be AC systems, engines, electronics, you can't run through and diagnose issues if you don't understand how the entire system works as a whole. Just to give some context of My night, it started with my water heater leaking and i went looking for info on a Tankless one and somehow ended up here lol. I will say i'm glad i found your channel as i've already learned a ton more about refrigerant systems and i will use it in the future on cars.
@g2gequipment789
@g2gequipment789 2 месяца назад
Great job - this is how I train all my guys to tidy up. - excellent job and clean brazing and getting all future issues too
@stephennichols4815
@stephennichols4815 8 месяцев назад
I always preferred c cutting out the drier too prevent releasing any moisture they might have in them . Back long long time ago we used to reuse the d 48 core driers and put them in a oven heating them up release the moisture lots of drier cores used on grocery store start ups foundunits that high pressure problems have realeased some moisture and it freezes in the expansion valve and the vox tep raises up to 3233 degrees and starts operating again until freezes in txv again when you change the compressor and do it properly you remove the moisture and any non condensables that may have entered system from lowrefrigerant leaks on the low side failed low pressure switch
@Portuguese-linguica
@Portuguese-linguica 5 лет назад
What's more annoying is fixing other people's mess-ups . My dad always told me and I always say if you're not going to do it right the first time . Move the hell out of the way and let the guy who's eager to do the job right the first time do it .
@HVACRVIDEOS
@HVACRVIDEOS 5 лет назад
I will be going Live on RU-vid tonight 8/12/19 at 5:PM west coast time to discuss my recent uploads and answer questions from emails,the chat, and RU-vid comments come check it out if you can ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-Os9rV7YWjzo.html
@aa999xyz
@aa999xyz 5 лет назад
the restaurant should give you a free lunch if it's something you like
@stephenconnell
@stephenconnell 5 лет назад
Glad to see your looking after yourself with the portable shade. No good you over heating along with the machine also a working lifetime of unprotected exposure to the sun can lead to nastier problems later on in life.
@HVACRVIDEOS
@HVACRVIDEOS 5 лет назад
I will be going Live on RU-vid tonight 8/12/19 at 5:PM west coast time to discuss my recent uploads and answer questions from emails,the chat, and RU-vid comments come check it out if you can ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-Os9rV7YWjzo.html
@redeye619
@redeye619 4 года назад
I watch alot of you videos and enjoy them, often jealous at how much room you have to work in with alot of these units just by pulling a one piece cover off etc, too often I've gone to to this sort of job too often I've been to replace compressors etc and the entire unit I'm working on would just about fit into the space you've got around the compressor alone, especially the temperzone and carrier units I've delt with
@shakeyjakey35
@shakeyjakey35 5 лет назад
love watching your videos how you take pride how you explane things from start to finsh
@lewisb7800
@lewisb7800 4 месяца назад
Bro u gotta do a vid explaining how much you charge..so us new techs can see wat we should be charging the customer..
@chriscooley906
@chriscooley906 5 лет назад
Great video Chris, those jobs always test ones patients, nice systematic approach, and a happy ending for all, thanks for the insight as always I appreciate you sharing your experiences well done bud !!
@HVACRVIDEOS
@HVACRVIDEOS 5 лет назад
I will be going Live on RU-vid tonight 8/12/19 at 5:PM west coast time to discuss my recent uploads and answer questions from emails,the chat, and RU-vid comments come check it out if you can ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-Os9rV7YWjzo.html
@jellogaming2051
@jellogaming2051 3 года назад
I work at a grocery store and our walk ins keep going down overnight and the company calls our store about high temps, and my manager said that he just pushes a button and it starts running again, high pressure switch?
@Goldstacker1972-kp2bh
@Goldstacker1972-kp2bh 6 месяцев назад
Why don't you tie the te defrost timer pump down into the defrost timer? Or maybe I just misunderstood what you said?
@alaaibrahim9742
@alaaibrahim9742 5 лет назад
You are a great teacher. thank you for the useful information.
@chessplayer8019
@chessplayer8019 4 года назад
which brand is your brazing torch..?and nozzil size? it is good flame...pls answer...
@ryanw.k.2840
@ryanw.k.2840 5 лет назад
I noticed you did that trick where you take the cap off the marker with your teeth, I used to do that but now i keep a retractible sharpie in my shirt pocket. Anyway, great video as always. Thank you for putting so much time into what you do! Keep up the good work sir
@crforfreedom7407
@crforfreedom7407 5 лет назад
Yep! The retractable dry up a little quicker, but not NEAR as fast as the ones I've bitten and cracked the caps on!
@Brendan_Keyport-WA7BMK
@Brendan_Keyport-WA7BMK 4 года назад
Out of curiosity, why did you bother to check the old compressor oil? Did it really matter?
@rigakit
@rigakit 4 года назад
Crazy call! ,I have a problem Telling the customer then selling the truth of it !
@akachuck99
@akachuck99 5 лет назад
I'm not a HVAC guy I work EMS but I really enjoy your videos especially the longer the ones
@viston100
@viston100 5 лет назад
When you have multiple jobs on a given day do you take changes of uniform with you?
@HVACRVIDEOS
@HVACRVIDEOS 5 лет назад
Yeah I usually will keep an extra set of clothes in the van however I hardly ever use it.
@abujamie3763
@abujamie3763 5 лет назад
Put Silfos on the joint before you sweat it off and it’ll be super slick when you slide it into the next compressor
@akhermit5213
@akhermit5213 5 лет назад
The discharge pressure always blows my mind. Our ambient never gets near what you have there. Average hot days here are low 80s. Anything above that and systems are struggling here.
@jac01055
@jac01055 5 лет назад
Your work and your tools are amazing. Huge respect. Subscribed. Thanks for sharing.
@herogibson
@herogibson 4 года назад
thank you for giving me these videos that i never knew i wanted! this is a subject you would never ask for, but there is a LOT going on here. this is very interesting stuff to see this side of the coin when your walk-in takes a shite lol
@johnjohnston214
@johnjohnston214 4 года назад
Don’t panic when hot oil shoots into your left eye. Wear safety glasses.
@petreebobalong
@petreebobalong 4 года назад
I am in the process of starting my own HVAC maintenance and service business, I can only hope to be as half as professional as you!
@memyselfandifarmer
@memyselfandifarmer 5 лет назад
Comment as we go, Always wear safety glasses while testing electric . Contractor- lug or screw. Pressure controls that are the pig tail style are junk.
@evanthelegend7610
@evanthelegend7610 4 года назад
Just what I needed a sleeve hung compressor to fall asleep to. Makes me laugh
@evanthelegend7610
@evanthelegend7610 4 года назад
Some times auto correct is mean
@Goldstacker1972-kp2bh
@Goldstacker1972-kp2bh 6 месяцев назад
OHave you ever had to change a 4DA-2000-TSK?
@williewill46
@williewill46 4 года назад
I enjoy watching your repairs, but, you talk to fast for me, I'm trying to follow you in what you are trying to explain.... but, never the less I really enjoy it
@memyselfandifarmer
@memyselfandifarmer 5 лет назад
112 outside temperature = fry some baloney , sandwich with miracle whip!
@steve19841117
@steve19841117 5 лет назад
thank you MR. Stephen you are doing a such great job. i was watched everysingle of you videos thank you sir.
@The5599-b8e
@The5599-b8e 3 года назад
Knew it was a bad compressor a few seconds in. Those torches are way to high as well.
@herogibson
@herogibson 4 года назад
oh man.. hopefully thats a corporate place. thats gonna be a LARGE bill. this is a major part of the reason why you NEVER want to open a restaurant lol. unless you got money you don't mind just setting on fire
@teeckg
@teeckg 4 года назад
how much this bill $2000 ?
@lylefjeldstrom1408
@lylefjeldstrom1408 3 года назад
Noticed you brazing without safety glasses bad boy
@sahmyung4228
@sahmyung4228 3 года назад
Why did u have the recovery tank upside down to recover the gas?
@larsjansson2625
@larsjansson2625 3 года назад
God job. Just a little tip. Move the buld into a horisontel posisiton. The liquid in it will work better when it is in contact with the kapillär, Sorray for my bad english. Greatings from Sweden.
@larsjansson2625
@larsjansson2625 3 года назад
Should be bulb - not buld......; )
@coleherndon701
@coleherndon701 4 года назад
Wheres the ptrap on that evap lol
@harryjames5904
@harryjames5904 3 года назад
Why did you change the working condenser motors and sight glass? You were a few components with the exception of the receiver and time clock from making it feasible just to change the condensing unit.
@HVACRVIDEOS
@HVACRVIDEOS 3 года назад
I will discuss this on my Livestream this evening 3/22/21 @ 5:PM (west coast time) come over and check it out ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-4C3S2VG1qC8.html
@matthewgregory8218
@matthewgregory8218 3 года назад
Or it’s the blower wheel that’s done maybe the belt Is to loss and the pulleys
@johnjohnston214
@johnjohnston214 4 года назад
Please put your safety glasses on. Make it a habit.
@DWAYNE2ism
@DWAYNE2ism 4 года назад
Appreciate the your workmanship.
Далее
BEER WALK IN DISASTER
41:17
Просмотров 311 тыс.
R-290 REFRIGERATOR NOT WORKING
1:05:38
Просмотров 367 тыс.
Se las dejo ahí.
00:10
Просмотров 4,5 млн
Barno
00:22
Просмотров 753 тыс.
Learning about Electrical panel.
4:23
Просмотров 2
Walk-In Cooler Warm and Compressor Is HOT
12:26
Просмотров 15 тыс.
THIS IS WHY I LIKE TO DO EVERYTHING MYSELF
32:39
Просмотров 122 тыс.
LATE NIGHT WALK IN COOLER CALL.....
55:00
Просмотров 214 тыс.
KITCHEN AC NOT WORKING
20:58
Просмотров 53 тыс.
CAN THE BEER WALK IN BE TOO COLD??
52:44
Просмотров 247 тыс.
THIS WAS A TOTALLY UNNECESSARY SERVICE CALL
48:34
Просмотров 125 тыс.
LATE NIGHT WALK IN FREEZER TRIPPED BREAKER.........
35:11
BORROWED TIME IS AN UNDERSTATEMENT
43:30
Просмотров 92 тыс.