Тёмный

Week 6 Electrical Exam Prep Video Series, Journeyman and Master Electrician Exam Series 2017/2020 

Electrical Exam Coach
Подписаться 5 тыс.
Просмотров 32 тыс.
50% 1

We offer the #1 Electrical Exam Prep Program
FREE VERSION
electricalcodecoach.com/free-...
PRO VERSION
www.electricalexamcoach.com/m...
USB OR DVD PROGRAM FREE SHIPPING!!
electricalcodecoach.com/shop/...
400x Practice Exam PDF Download for only 14.99 electricalcodecoach.com/shop/...
2017 Tabs with FREE SHIPPING
electricalcodecoach.com/shop/...
2020 NEC TABS with FREE Shipping
electricalcodecoach.com/shop/...
2023 NEC TABS with FREE SHIPPING
electricalcodecoach.com/shop/...

Опубликовано:

 

24 сен 2021

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 35   
@tr_micks
@tr_micks 2 года назад
Yes, would go to Mars and getting through the exam in time
@Electricalexamcoach
@Electricalexamcoach 2 года назад
Keep grinding bro!!
@notgeo4564
@notgeo4564 Год назад
I feel like week 5 got cut off or there is something missing between weeks 5 and 6. Help Coach!
@tallkatt303
@tallkatt303 Год назад
Same here
@srlewis76
@srlewis76 Год назад
For 2023 - equipment grounding conductor fill remains the same as 2020. 2023 - 314.16(B)5 (last sentence): A 1/4 volume allowance shall be made for each additional equipment grounding conductor that enters the box, based on the largest equipment grounding conductor entering the box.
@trestoncoleman85
@trestoncoleman85 Год назад
I would go to mars. Get a clean slate and get to test my cool ideas where no one else is. I have no fears. Conquering my drug addiction taught me that fear is just being held back by oneself.
@ulisesramirez6623
@ulisesramirez6623 Год назад
Professor the way you explain everything is so Amazing you have a gift I can believe how clear I can understand every topic thank you so much for your time and big Help.
@Electricalexamcoach
@Electricalexamcoach Год назад
Let's Go!!
@scottyladeuche
@scottyladeuche Год назад
brotha, it seems like the beginning of this lesson was cut off...we just jump straight to box calculations after the intro, but without really setting it us as usual. Am i processing this incorrectly?
@art-fl8kg
@art-fl8kg 2 года назад
thank you brotha! this video is so helpful
@JoseMoreno-sf6ib
@JoseMoreno-sf6ib Год назад
that ill forget to pray the day of the exam.
@williamspencer4008
@williamspencer4008 6 месяцев назад
The one way ticket threw me off,one way means you're not coming back,How bout a round trip ticket to Mars so I can come back and tell everyone how it was.💙 My my only fear about taking the test is ,I won't pas on the first try! Thx coach YOU ROCK. When I take my test in March/April and pass ,Can you please give me a shot out.Thz in advance 🙏🏾🙏🏼👍🏾
@Duzten
@Duzten Год назад
are you counting the first 4 egc"s as 1cu in? its my understanding they count as 1 based off the largest conductor. example. if all conductors are #12, then the first 4 egc's will equal 2.25. not 1.
@Electricalexamcoach
@Electricalexamcoach Год назад
Not one cubic inch, but one conductor and then I multiply it out by the cubic inch volume of the number #12.
@arnieselectric007
@arnieselectric007 Год назад
at 6:54 your answer for MAX volume should be minimum volume being that is the name of the column...Correct..?
@Electricalexamcoach
@Electricalexamcoach Год назад
It's minimum for the manufacturer, it's maximum for you and me.
@tomedavtube
@tomedavtube 7 месяцев назад
First slide about 2020 EGC says says "1/4 INCH" volume for each additional EGC after 4. HOWEVER, 2020 code says: "single VOLUME allowance" up to 4 and "quarter VOLUME allowance" (NOT INCHES) for each additional EGC Confusion with this question: 3#12 Hot + 3#12 Neutral + 1#12 EGC+ 3#14 Hot + 3#14 Neutral = 27.27 Answer '27.75' is based on 2017 code not 2020 Same example If 2020: 3#12 Hot + 3#12 Neutral + 1#12 EGC + .5#12 EGC + 3#14 Hot + 3#14 Neutral = 28.875 Is this correct??? Confusion with this question: 7#12 EGC Discussion says "1/4 INCH" but calculation is based on "1/4 VOLUME" Same with this question: 6#12 Hot + 6#12 Neutral + 6#12 ECG Discussion says "1/4 INCH" but calculation is based on "1/4 VOLUME"
@amudasesay2396
@amudasesay2396 2 года назад
Hello Coach, thanks for all the videos. For the 6 EGC #12awg, the first 4 is 2.25. Then 1/4 volume of 2.25 should be 0.5625 and not .25 Please verify, I could be wrong. Thanks
@Electricalexamcoach
@Electricalexamcoach 2 года назад
Yes the .56 is the converted number. but .25 * 2.25 is the same number.
@steveterry54
@steveterry54 Год назад
I would not go to Mars for any reason. My greatest fear of taking the test is the time it takes to do the back and forth in the book finding answers for questions with which I'm not familiar.
@chicokali936
@chicokali936 7 месяцев назад
the last answer is also in 230.10
@ryanvelez6367
@ryanvelez6367 2 года назад
Lord I hope they allow a calculator in the testing center
@Electricalexamcoach
@Electricalexamcoach 2 года назад
Most testing centers do or provide a digital one.
@shmekoaltham1798
@shmekoaltham1798 Год назад
??230.90 deals with overcurrent protection, and doesn't say anything about overhead clearance(47:33 last question)
@lackey2447
@lackey2447 Год назад
Yeah that's in the 2023 Nec ,I was confused too and I couldn't find the clearance over doors and windows in the 2023
@ryanvelez6367
@ryanvelez6367 2 года назад
Wait here youre talking about a free Exam prep on your website. Is that different from this one?
@Electricalexamcoach
@Electricalexamcoach 2 года назад
It* puts it in order and tracks your progress
@arnieselectric007
@arnieselectric007 Год назад
At 29:32 6 #14 should be 2.00 which is 12+ 4.5 for 2 X largest wire which is 2.25...am I right or wrong here..?
@Electricalexamcoach
@Electricalexamcoach Год назад
Great question! it is based off the largest wire connected to the device
@ammaraldulaimi3237
@ammaraldulaimi3237 Год назад
For 2020 EGC you should add 1/4 " to the volume not 1/4 of the conductor
@Electricalexamcoach
@Electricalexamcoach Год назад
I appreciate the angle, but it's the same math.
@jlgroethe
@jlgroethe Год назад
I think the 2020 code says to add a 1/4 volume based on the EGC size, not 1/4 inch. That’s how I read it.
@juiceboy2961
@juiceboy2961 2 года назад
confusing that your teaching the 2017 version of EGC.
@Electricalexamcoach
@Electricalexamcoach 2 года назад
Keep watching, we cover the 20/20 as well. Half of the country still on the 2017 and will be for the next several years.
@carbq5280
@carbq5280 Год назад
No, mars is fake and my biggest fear is that I'll pass my test.
Далее
Top 25 Electrical Tables and How to Read Them!!
1:05:21
2023 NEC Box Fill Lesson
15:48