Тёмный

When NOT to Re-Wire a House. In what you can do instead! 

Electrical Code Coach
Подписаться 63 тыс.
Просмотров 39 тыс.
50% 1

We offer the #1 Electrical Exam Prep Program
FREE VERSION
electricalcode...
PRO VERSION
www.electrical...
USB OR DVD PROGRAM FREE SHIPPING!!
electricalcode...
400x Practice Exam PDF Download for only 14.99 electricalcode...
2017 Tabs with FREE SHIPPING
electricalcode...
2020 NEC TABS with FREE Shipping
electricalcode...
2023 NEC TABS with FREE SHIPPING
electricalcode...

Опубликовано:

 

28 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 40   
@boneheded2819
@boneheded2819 Год назад
The rifle vs shotgun analogy is pure gold.
@swervomatic
@swervomatic Год назад
Its hard to get old homes to hold on AFCI/GFCI breakers because of the shared neutrals usually
@EHD351
@EHD351 Год назад
You are 100% on it. Thanks Sir.
@matt7iron
@matt7iron Год назад
I live in a one story house with a 4ft crawl space all under the house, do they have to destroy my walls to rewire
@smak1857
@smak1857 Год назад
Excellent explaination. I got a problem in my home. We purchased the property last month and the house was built in mid 70s. Lights and other appliances are working fine. I am renovating some rooms installaing dry wallsvceilings and some spot lights in every room. Our guy building ceilings when installed spot lights spreaded around the room are not completely ON. One side work others not. He is not a professional electrician but advice to rewire the house because low voltage. Rewiring a house is a long process. We called a professional electrician and he advised to change the old circuit breaker. We are willing to change but my question after replacing the circuit breaker box the problem will be solved where we have low voltage in our rooms? Thanks
@jlandor1
@jlandor1 Год назад
Awesome explanation!!
@patrickkavanagh6958
@patrickkavanagh6958 Год назад
Another reason we do a lot of house re-wires post 1950's is being here in Hawaii with all the salt and humidity in the air. Thanks for all you do Coach! 🤙
@jseen9568
@jseen9568 Год назад
My main issue is that our house was built in the 70s, the entire house other than the Stove, AC, and water heater is on two-60amp breakers. That's it. All outlets, all lights, all switches are all on the same breaker (there are also 2 outdoor outlets as well). I am curious if it would be worth it to either 1) rewire only parts (such as outdoor lights and outlets going to one breaker, fridge going to one breaker, rooms groups going to one breaker, and bathrooms going to one breaker). or 2) essentially rewire the entire house. Most of the junctions are in switch boxes, not the light fixtures (because there hardly were any). Most of the wires look in really good condition.
@ElectricalCodeCoach
@ElectricalCodeCoach Год назад
Great question! Every house is different, i would get with a qualified licensed electrician and make some strategic moves to help spread the load around! Consider asking them to educate you on AFCI and GFCI breakers
@PowerHourMat
@PowerHourMat Год назад
Thanks Coach
@lovelylisa.enterprises
@lovelylisa.enterprises 8 месяцев назад
thank you. may god continue to bless you
@alangivens7983
@alangivens7983 Год назад
Great content, thanks.
@befree9579
@befree9579 10 месяцев назад
My apartment in UK is 1965 build. Electrician is like it needs full rewire. Cause his excuse is the watts of machines, cooker is much higher now so it's too much strain. Mmm i don't want to spend $4k when my apartment has been renovated already.
@hammerridecycling7630
@hammerridecycling7630 Год назад
i bought a 1959 home this year i upgraded my panel.but the wires inside the wall has no ground wires.should i replace all the breakers on the panel with afci breakers?thanks
@ElectricalCodeCoach
@ElectricalCodeCoach Год назад
I would contact a qualified license electrician and ask them about dual function technology
@ProdSlime-yv8sg
@ProdSlime-yv8sg Год назад
bro has an mpc out here making beats and twisting wire nuts lmaooo
@ElectricalCodeCoach
@ElectricalCodeCoach Год назад
Haha about four people know I make beats who's this?
@ProdSlime-yv8sg
@ProdSlime-yv8sg Год назад
@@ElectricalCodeCoach i just saw the mpc respect the hustle
@ElectricalCodeCoach
@ElectricalCodeCoach Год назад
Lol Sweet bro I really appreciate it I saw some of your videos looking good!
@m.pav.8397
@m.pav.8397 Год назад
How can i find a good electrician that wont over price their work? I dont mind paying a fair price. How do i figure out a fair price?
@bigfish8280
@bigfish8280 8 месяцев назад
In the minority of cases, ( in my experience) 1950's or earlier. I would recommend a complete electrical upgrade. From soup to nuts. First of all, the value which is added to the property afterwards is significantly greater than the cost of the project. Secondly, why take the risk? Even with inspecting all visually accessible wiring, who's to say that the inaccessible wiring isn't compromised.
@ELgratitude
@ELgratitude 3 месяца назад
Thanks
@benefactionhindrance
@benefactionhindrance Год назад
Definitely update the panel and add branch circuits. Upgrade the service if you can afford it. EVs will be a thing whether you like it or not.
@robinsymonds5353
@robinsymonds5353 3 месяца назад
@burntrubber7458
@burntrubber7458 9 месяцев назад
Mine was built in 1890 and is "livable". No AC and needs everything redone! Quite the project. New electrical panel, lifted the floors with foundation work and had a new well drilled so far. Much more to go!
@David-mv5nh
@David-mv5nh Год назад
Excellent explanation brother, thank you for your time and effort putting this videos together!
@Neil-ym8vy
@Neil-ym8vy Год назад
Also most pre 1950 homes have either cloth or knob and tube or both. In which case most good electricians will not renovate it without doing a rewire. My uncle's house was pre 1950 and he lost money on ithe sale because he had knob and tube wiring.
@steveloux4709
@steveloux4709 Год назад
Knob and Tube is a wiring method that would be found generally 1941 or earlier. And the advice he shared applies equally to K&T. Just because it's there does not automatically mean it needs upgrading. Undisturbed by the unqualified, it is a very quality wiring system which can continue to serve the home well 80+ years later, particularly for general purpose branch lighting (the lighting and receptacle outlets of living rooms and bedrooms in particular).
@jarrydee2799
@jarrydee2799 Год назад
@@steveloux4709 Customers that can not afford a rewire that have knob and tube, I usually upgrade the service and install GFCI breakers, that way they can install 3 prong receptacles to code. We are not required to use AFCI in Michigan.
@windturbineclimber5412
@windturbineclimber5412 Год назад
Definitely glade I found this channel
@dylane330
@dylane330 Год назад
Another mention I might add is aluminum small wire branch circuits…. Either replacing receptacles and switches with Al/cu connections or using a listed connection to transition to cu and make the connection from there.
@georgeryan9139
@georgeryan9139 Год назад
You need wiring with proper amp, circuit breaker, wire gauge with ground and outlet.
@radsmack
@radsmack Год назад
what about the simple fact of just not having ground wires in any boxes for outlets and switches just bought the house and was trying to get new ones and noticed that
@suzannem7418
@suzannem7418 Год назад
Thank you for the info. Can you also comment on if I upgrade my pushomatic breaker box and do I need to add a ground and then if I add a ground, what do I need to do with all the outlets?
@JayKayOkie
@JayKayOkie Год назад
I have a 1960 house and would like to upgrade the panel, but I was never sure if that meant I would have to rewire the house to add a ground wire.
@vince6829
@vince6829 Год назад
Thank you for sharing your knowledge. Very much appreciated.
@lolol7110
@lolol7110 Год назад
I’m in the testing center . If you ask for 75 degree C , for a specific insulation , which is listed in the 75 degree c column , why is the answer wrong ? The correct answer was in the 90 degree c column . My wire was listed in both columns but the question asked about 75 degree C . I’m wondering because , 75 degree C has a column and I was correct when using it on another question so I’m like ... what happened ?
@ElectricalCodeCoach
@ElectricalCodeCoach Год назад
Hey bro just shoot me an email electricalcodecoach@gmail.com
@Arthiem
@Arthiem 7 месяцев назад
Hello fellow tennesseean here. Ive got a 1949 house that has undergone half modernization with expansions. But the original 3 bedrooms are completely ungrounded. And we have computers and stuff we just can't use. Is there anyway to be able to run ground wire to these older outlets, or a way to test if the steel boxes themselves were grounded by chance?
@donovanbeckford5370
@donovanbeckford5370 2 месяца назад
Keep up the good work!!!!
Далее
Knob and Tube Wiring: Top 5 Issues | Jesse Kuhlman
9:23
Avaz Oxun - Yangisidan bor
14:29
Просмотров 434 тыс.
Estimating Re-wires. 5 questions to ask..
12:22
Просмотров 8 тыс.
Pricing a house rewire- How Much
13:59
Просмотров 53 тыс.
Electrical Wiring Basics
23:40
Просмотров 2,9 млн
Issues with Old Electric Wiring | Knob and Tube
8:03
Просмотров 288 тыс.
When and Why to separate Grounds and Neutrals.
10:32
Просмотров 270 тыс.
House Rewire - Day One - Electrician Life
13:05
Просмотров 127 тыс.
Tracing Old Electrical Wiring
15:58
Просмотров 93 тыс.