This Schneider Electric switch has an extra terminal labelled loop. This loop terminalis not connected to any other part of the switch so is effectively a point to connect conductors together. In this video we see how it could be used to join the neutrals together if you take the feed to the switch.
🔔 Subscribe for more free electrical training videos ru-vid.com?s...
== 🕐 Time Stamps - Cut to the action 🕕 ==
00:00 - Why a loop terminal
00:05 - Terminals
00:14 - Neutral connections
00:35 - Testing
00:57 - Proving we have no connections
Videos are training aids for City and Guilds (C and G) and EAL courses Level 1, 2, 3 plus AM2, AM2S and AM2E.
You can follow me day by day on Facebook, Instagram, Twitter and TikTok lookout for "GSH Electrical”.
▶️ FACEBOOK / gshelectrical
▶️ INSTAGRAM / brihzmraygdtmjmdb9lunq...
▶️ TWITTER / gsh_electrical
▶️ TikTok vm.tiktok.com/ZMRBLFdhe/
#GSHElectrical #Electricaltrainingvideos #tt #electrician

Опубликовано:

 

6 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 22   
@BrianSu
@BrianSu 4 месяца назад
It's just there to help join 2 Neutral wires together without the need for a terminal block.
@curtisj2165
@curtisj2165 Месяц назад
You can also stick the earth in there
@SheikhMohammadZakaria
@SheikhMohammadZakaria Месяц назад
I am from Bangladesh,your Explained is very nice,all time I am follow you,,,
@redqutoxic3876
@redqutoxic3876 Месяц назад
Glad I’ve seen this, I’m doing my 2365 installation at college and all they have are these switches plus intermediates. Took me a while to work this switch out😅
@GSHElectrical
@GSHElectrical Месяц назад
Thanks for watching and good luck with your course
@m101ist
@m101ist Месяц назад
They should insert a common terminal connection into a intermediate switch for the black common wire.
@technicalraja-ld2mp
@technicalraja-ld2mp 28 дней назад
😊😊😊😊
@andysims4906
@andysims4906 Месяц назад
If it was me I would ignore that loop terminal and join the wires in a separate connector. If the switch is ever changed by a DIYer the less wires going to the back of the switch the better
@DavidLee-vi8ds
@DavidLee-vi8ds Месяц назад
I would prefer a switch without a loop terminal.
@PonNguyen-wu5rq
@PonNguyen-wu5rq Месяц назад
Tuyệt vòi
@chrisardern4594
@chrisardern4594 Месяц назад
Never seen one of these switches before at first look I thought it was a intermediate switch.
@m101ist
@m101ist Месяц назад
I noticed the terminal for the neutral connection is slightly larger.
@daved4547
@daved4547 Месяц назад
Those lights cables @ 1:22 are atrocious! 😳Copper showing as well. 🙄 😎
@ingy23
@ingy23 Месяц назад
To me would have made more sense to call it NC for not connected
@Tryingtimes007
@Tryingtimes007 Месяц назад
I would terminate the light switch then re-test. A TNCS system might prove otherwise
@spudhead169
@spudhead169 Месяц назад
Would a neutral be going to a switch?
@madmick8881
@madmick8881 9 дней назад
It can do for a number of reasons. .
@spudhead169
@spudhead169 9 дней назад
@@madmick8881 None of mine do, they're all line and switched line return only.
@madmick8881
@madmick8881 9 дней назад
I,ve never seen a loop terminal in a switch but an example of it's used is you may want to put a lampost type fittiñg outside your front door. If you have pulled a neutral into your switch you only need to run one twin and earth cable to your lampost from the switch.​@@spudhead169
@johnwarwick4105
@johnwarwick4105 Месяц назад
Typical solution to a problem that doesn’t exist. With the advent of waggo connectors or similar, connect the neutrals in the back of the box out of the way
@GSHElectrical
@GSHElectrical Месяц назад
Thanks for your thoughts
Далее
No More Wiring Additional Switches
1:28
Просмотров 2,4 тыс.
Concentric Cable - TN-C-S Cutout Connections
1:00
Просмотров 295 тыс.
WE COOKED A SHRIMP KEBAB  #recipe #barbecue #food
00:21
Просмотров 336 тыс.
Armeg Channelling Chisel
0:55
Просмотров 45 тыс.
Perfect Bend in Steel Conduit Every Time
6:12
Просмотров 2,9 тыс.
How Close Can You Install a Socket to a Sink?
2:36
Просмотров 10 тыс.
US smart socket
0:52
Просмотров 4
Threading Steel Conduit
1:47
Просмотров 1,8 тыс.