How do you wire a zone valve? What is a zone valve? During this zone valve wiring for beginners video, I simplify the confusing and overwhelming task of wiring for diagnosing defective zone valve wires.
Need a website for your contracting business? Check out Footbridge Media for their amazing special on not only a website but SEO services for only $249/month! www.footbridge...
I used HIK Micro B20 thermal camera to verify working equipment
amzn.to/3BkJC5Q and I wear Brunt pants and boots available here: bruntworkwear....
Tired of HouseCall Pro? Don't wanna be ripped off with ServiceTitan? Try ServicePal for free for 30 days! app.servicepal...
(You can thank me later)
Please take a moment and click that 👍 button! Much appreciate the support from the community.
Check out my Uncensored channel: / mikeypipesuncensored
Oval raised silver stickers are from:
Armored Decal Company Inc.
35 Victoria St. E, Unit 9
Alliston, Ontario L9R 1T3
(p) 705-435-6665
(e) ken@armoreddecal.com
(Tell them Mikey Pipes sent you)
Please support this channel and Mikey Pipes and consider the following…
UPDATED: 12/15/22
PIPE DOCTOR FLEX FIT HATS only $40 each shipped USPS! Or 2 for $70
PIPE DOCTOR & BOSCH long sleeve shirts are available in sizes 2XL
Minimum donation of $21 is appreciated. Or (2) for $35 delivered within the US.
Shopping on Amazon? Please use my referral link amzn.to/2PjjS4v
Sticker Requests:
Do you want a sticker to show your support of this channel? Email your request to me! mike@mikeypipes.com
Name
Address
City, State, Zip
Consider making a donation of $5.00, or ANY amount, to the postage fund! I literally mail out stickers all over the globe. I've sent stickers to HVAC guys in Afghanistan, New Zealand & all over Europe.
PayPal is: office@pipedoc.net
Venmo: @PipeDoctor
CashApp: $mikeypipesny
Want to send a love letter, note or gift? Our mailing address is:
Mikey Pipes
C/O Pipe Doctor Home Services, Inc.
80 E Hawthorne Ave
Valley Stream, NY 11580
Join our team! PIPE DOCTOR HOME SERVICES is expanding to the great State of South Carolina!
WE ARE ACTIVELY HIRING:
SERVICE PLUMBERS
HVAC TECHNICIANS
DISPATCHERS
For our location in:
NORTH CHARLESTON, SC

Опубликовано:

 

4 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 196   
@pets7164
@pets7164 29 дней назад
He is like a magician using sleight of hand. He want you to know but he doesn’t really want to let you know.
@PipeDoctor
@PipeDoctor 29 дней назад
Don’t be annoying
@douglasmayherjr.5733
@douglasmayherjr.5733 Год назад
Wiring is one of the hardest concepts for guys to learn, when they get it, it’s like a light bulb turning on in there heads. I have been teaching HVACR Apprentices for close to 20 years, on and off. Really Good Video, Mike. Some guys learn by seeing a diagram, some by reading a book, some by watching a video and others need to put there hands on it and do it over again. In the trades it’s usually the hands on type, not being disrespectful at all, I don’t care how someone learns, as long as they learn. 👍🏻👍🏻
@Stormy2510
@Stormy2510 Год назад
I generally don't comment on these videos, but my goodness.. This was simply phenomenally done. Very detailed, but easy to follow and understand. And most importantly, it wasn't boring. This allowed me to watch it completely without skipping through and missing important things... Well done, sir. You certainly earned my subscription.
@jondolan8551
@jondolan8551 Год назад
Man you don't know how refreshing it is to watch you cut that cluster fn mess and it is simple to do a neat n tidy job.
@paulkenney5846
@paulkenney5846 Год назад
Mike, I wish I had a mentor like you. I worked in maintenance for 45 years. Maintaining and repairing specialty wire production machines. Extruders cable machines. First 10 years none of the old-timers would show me anything. After gaining knowledge on my own any time a new mechanic came into my shop I would show him everything I knew. I watch your videos every day you were the man.
@MannistoCay
@MannistoCay 18 дней назад
Learning every time. Cheers
@PipeDoctor
@PipeDoctor 18 дней назад
Thanks so much for posting your feedback. Remember if you’re looking for a local plumber call 516-348-6300.
@alanburris463
@alanburris463 Год назад
Great video. Sir you know your shit. These guys working for you have a great opportunity to learn the right way and make a great living. I’ve got a couple years in plumbing and looking forward to get my hvac license. Good luck in Florida!!!
@neildesposito1492
@neildesposito1492 10 месяцев назад
Mike incredible informative video thank you
@falconxlc
@falconxlc Год назад
please, more of these educational videos! Perhaps your own HVAC course? haha thank you for these videos.
@eddiew.6485
@eddiew.6485 Год назад
We use to call wiring like that a “Rats nest”! I would do like you did, cut back all the excess, organize the wires by pair, and put Brady tags on them making it easier for the next tech. Great job as always, Mikey👍
@wilthomas7766
@wilthomas7766 Год назад
Willlie from Phillie, “ love your video’s “ giving us newbies the skiils that will bring back respect 4 the tradesman! Thank you so very much ! -Willie
@davefoisy8751
@davefoisy8751 Год назад
Mikey … can’t thank you enough for this one my hvac guy was lost … watched your video and BOOM ALL IS WELL !!! Thanks
@albertcaushi9343
@albertcaushi9343 Год назад
You can’t know how spot on you are with the part where u said what your sisters watch
@oscarreyes3175
@oscarreyes3175 9 месяцев назад
It’s my first time watching your videos and you’re great My whole family is from New York, my mom lives in Oceanside and my cousin in island park and Long Beach. From Indianapolis enjoying your videos
@PipeDoctor
@PipeDoctor 9 месяцев назад
Welcome!!
@mattwittneben443
@mattwittneben443 Год назад
Since watching your channel I can now look at my boiler and identify all the parts. Maybe even attempt to fix something if it breaks. Mikey Pipes taking over the world.
@Pure_H2O_Center_LLC
@Pure_H2O_Center_LLC 10 месяцев назад
As a fellow HVAC Professional, I was side by side until the Green wire! ;) And then you confirmed it at the end. You are a humble and professional, well deserving of the title as an educator. I too just like Stromy2510, have for the first time subscribed to a GURU in high regards! Great Job!
@scoobywrx05dw
@scoobywrx05dw Год назад
One statement you made I strongly agree with. Let's make the trades industry professional again. I get very tired of the half a$$ work that 80 percent of these heating guys do now a days. I run into more messes like you ran into with this than I do clean installs anymore. Not sure if it's because some people don't know what they are doing or if they are just lazy or a combo of both. Thank you for installing "pride in your work" to your apprentice and if your apprentice is reading this, that pride in your work is what will land you jobs for the rest of your life.
@davidb.2355
@davidb.2355 7 месяцев назад
Thank you! Best video I've seen yet!! I definitely learned something. Great video!
@PipeDoctor
@PipeDoctor 7 месяцев назад
Glad it was helpful!
@ATSNorthernMI
@ATSNorthernMI Год назад
You appreciate us watching and we appreciate you teaching us. I learned so much watching you just like an apprentice learning from a master being right there and listening to you explain what's going on is priceless. I couldn't get one contractor to take me through the trade because they have to pay me a decent wage. They'd rather hire a guy that can make them stacks of cash without having to "baby sit" them all the time. It's hard to survive in a world of lazyness and being cheap. Someone has to make that decision of do I want to waste 50k a year on someone or pocket that money. Because of that, I work at walmart stocking produce barely surviving. I used to build 480v service's, run conduit, romex, doing a lot of residential work such as wiring entire houses by myself to struggling to stay afloat. Where I am, there isn't a lot going on and learning a new trade is always a plus, especially when that guy decides to drop 50k a year on an apprentice, they better step up to the plate.
@Spoiler5081
@Spoiler5081 9 месяцев назад
DC voltage Oneway street… AC Voltage 2 lanes… helped me get my head wrapped around it when it was being taught and explained to me great video!
@takedeadaim8671
@takedeadaim8671 Год назад
Nice job of cleaning up a goat rodeo. I do this a lot of this, I hope some day WAGO will follow, but I was taught to do these with terminal blocks mounted to a board somewhere near the valves. In later years I went to running the thermostat wiring in plastic push lock air tube to eliminate pinching loose wires. It looks great on multi zone radiant systems and it’s easy to install drill a hole pop in a rubber grommet and use a zip tie to retain.
@alexrapp4253
@alexrapp4253 Год назад
A rats nest of wiring always gets me excited, love a good challenge, good work mike!
@scottvolage1752
@scottvolage1752 Год назад
The Rubes are strong with this one. Nice Video Mike and Peter. Bring on the waygos.
@chuckquinn8026
@chuckquinn8026 Год назад
Mikey is always 100% confident and fearless in his wiring skills and never lets us down 👍👍
@bruceelias2732
@bruceelias2732 Год назад
Thanks Mike
@josetineo223
@josetineo223 Год назад
Best detailed video of wiring
@josetineo223
@josetineo223 Год назад
Best detailed video. I had the same mess and without your help, I would have not been able to upgrade to my modern wifi thermostat. I'm currently happily following you. Thank you!
@JohnSmith-cp2yg
@JohnSmith-cp2yg 10 месяцев назад
Great video I'm not even know why HVAC or nothing but I want to get into it and I'm learning a lot of stuff from you thanks Mikey I'm putting in my own boiler
@brokensmile8487
@brokensmile8487 Год назад
I just love seeing that wago jump back in your case. 😂
@stanleykania7184
@stanleykania7184 11 месяцев назад
Nice work
@jacktorres8691
@jacktorres8691 Год назад
professor freaking pipes, zero doubts mr. pipes knows what he is talking about .btw....you like john deer tractors?
@nonoyrafael9505
@nonoyrafael9505 7 месяцев назад
remarkable! the best
@PipeDoctor
@PipeDoctor 7 месяцев назад
I’m very happy you enjoy this video. Hopefully you got something out of it. Learn something new every day let’s go.
@pawelpaluchniak4416
@pawelpaluchniak4416 11 месяцев назад
Thanks mikey
@tomcarrigan902
@tomcarrigan902 11 месяцев назад
Great job brother
@PipeDoctor
@PipeDoctor 11 месяцев назад
Thanks 👍
@myboy051
@myboy051 Год назад
I sold my old and purchased my house a year ago. I’m a Automotive tech of 20 or so years now. I do all the Diagnostic / programming work and electrical repairs. In my new house I have 5 zone valves that all work fine. However the wire management is D~ work. One part of me says just leave it alone the bigger part says clean it all up and redo it.
@b3d3g69
@b3d3g69 Год назад
Nice Video! If i may make a suggestion for future videos. Wire up only one zone valve so we can see and follow better. Then, proceed the way you normally wire them. I was following ok at first, but starting getting a little lost as you were adding more wires...
@robertcooke3500
@robertcooke3500 Год назад
This guys does such a good job explaining everything
@EB1156
@EB1156 Год назад
You made this very simple to understand with your... descriptive explanations! Thanks for the Vid!
@myf1165
@myf1165 Год назад
Wow Mike u make it look all eezy peezy
@Eddy63
@Eddy63 Год назад
Nice explanation and clean-up on aisle 4 ... You made it look so easy ... Thx Mikey Pipes ...
@martilmedrano624
@martilmedrano624 Год назад
I always coil up the extra wiring to make it look a little better, great work!
@megawhitesox0574
@megawhitesox0574 Год назад
you confused me when you hooked the green wire to t stat , downstairs i saw you use blue for common , glad you fixed it....great video five stars....hopefully the god you mention is the god of Abraham because thats my god..
@Ssplumbingandheating
@Ssplumbingandheating Год назад
Mike very knowledgeable video, thanks for your effort and well explained video. I recently learned the basic electrical and it all made sense ( I am plumber my self and learning electrical has been a huge plus for me). Thanks again Mike 🔥
@jspinosa50
@jspinosa50 Год назад
Neatness counts! Nice job!
@allisteclinton1186
@allisteclinton1186 Год назад
Great Video!!! Educational, Entertaining, Real. I just subscribed.
@daviddunn9898
@daviddunn9898 Год назад
Thanks for taken the time explain exactly what you're doing in walking through the steps I have been in HVAC for 3 year's It's great to see someone take pride in there work I have been in construction for long time I take pride in my work Any I can learn is greatly appreciated thanks for the video take care and Marry Christmas and Happy New year
@scottapt5291
@scottapt5291 Год назад
Nicely done Mr. Pipes. Good concise method and instruction. Thanks for spreading proper technique.
@impsquared
@impsquared 10 месяцев назад
absolutely a clean and detailed video!!! 🔥🔥🔥
@PipeDoctor
@PipeDoctor 10 месяцев назад
Glad you liked it!!
@angelruiz9549
@angelruiz9549 2 месяца назад
Good stuff 🎉
@jaas9457
@jaas9457 9 месяцев назад
I know my way around AC wiring, ever even seen a boiler. My brother moved to Iowa and asked me flr help with his boiler. This video showed me exactly what I needed to know. Thank you. I have a question tho. Why are the two thermostats next to each other? Doesn't that mean it'll never know the actual temp of the zone it's heating?
@gasfitter78
@gasfitter78 Год назад
Very interesting I'm a heating engineer from the UK. 90% of our zone valves and controls are on 230-240 volts and the 2 most common systems in the UK are called S-plan or Y-plan. The basic concept is the same. Keep creating great content and have a prosperous New Year.
@donduck6621
@donduck6621 Год назад
why dont they change that... much safer at low volt
@gasfitter78
@gasfitter78 Год назад
That mean retrofit step down transformer to millions of central heating wiring centre when this has been the normal for 40 yr
@williamserver4332
@williamserver4332 Год назад
My first hvac job was with an oil company in 99 before zone control boards were common. The hornets nest of wires was intimidating but now it's so easy. Important to know which t stat wire goes to which zone valve before tearing it apart to clean up. Great video
@verticallines212
@verticallines212 Год назад
they were not labeled so Mikey buzzed them out, that why he tore it apart like an animal.... lmao
@puranpaliwal5613
@puranpaliwal5613 Год назад
Best video
@jacksonHuynh-ou4ul
@jacksonHuynh-ou4ul 6 месяцев назад
Good video
@PipeDoctor
@PipeDoctor 6 месяцев назад
Thanks for the visit
@williamreick2669
@williamreick2669 Год назад
Steve lav, is the king of oil!
@Alex-jo2oi
@Alex-jo2oi Год назад
Great vid Mikey. Learned a few things.
@jth1699
@jth1699 Год назад
I have been a electrical controls guy for 40 years - if you want to confuse a kid just start using the term "common"... to explain circuits. In control circuits it's a switched hot until it goes through a coil or motor then it is a neutral. And all your doing with multiple stats like that is parelling them so when a stat closes it opens a zone valve and the switch in the zone valve turns on the boiler IF the boiler temp is below the set temp... you should build a teaching board to teach boiler and ac electrical to the beginners ...and some of the more experienced guys that still dont get it...
@josecarrasco4895
@josecarrasco4895 Год назад
that was very educational video good job Mike
@DodoLuca-s8v
@DodoLuca-s8v Год назад
Good job and I thank you very much I'm at an old timer I need help One thermostat works the other one does not work if I switch it around the one that I switched to it works and the other one doesn't work any advice I thank you and have a great day keep up the good work
@jimlafferty
@jimlafferty 11 месяцев назад
Hey, this is fantastic, and thank you for sharing. One *minor* quibble - can you add text overlays when you're asking the guy early on "what is this called?" I can't hear his replies and I'd like to know what they're called. Thank you.
@paulierluva
@paulierluva Год назад
excellent educational video Mikey p. great job!!!
@920HVAC
@920HVAC Год назад
Thanks Mikey! Your the man🤙
@arjunmali7195
@arjunmali7195 Год назад
Excellent work
@scottmaz4063
@scottmaz4063 Год назад
Great video mikey 👏
@robertpenczar8930
@robertpenczar8930 Год назад
Excellent job your the man
@PatrickBMoore
@PatrickBMoore Год назад
There's something weird about RU-vid when you watch it this video on Roku. Watching this video on the phone fine but when you get to 7 minutes and 14 seconds on RU-vid through Roku it gets out of sync. Meaning the audio and the video itself is no longer in sync. It's kind of like watching a dubbed Japanese monster movie. But it still was a very interesting and educating video. Great job.
@Joop5000
@Joop5000 Год назад
Those HoneyWell zone valves have 4 long wires, but not long enough! What do i mean? Well I like to wire all the low voltage wires into a junction box and make my connections in it. With Taco zone valves this allows me to do just precisely that, which in turn makes for a cleaner, neater job. I do like those new age wire connectors you used here, they are quite neat indeed! Don't get me wrong, i know this is not a new install, so we have to deal with things the way they are most of the time in heating service. BTW Congrats on your licensure endeavors.
@MarcHord-mk5ff
@MarcHord-mk5ff Год назад
Heck looks normal, always switched the ground or common. Check the wiring manual for how to hook them up.Easily done.
@JutanatuJ
@JutanatuJ Год назад
This video was extremely helpful and almost identical to my system with some minor differences. My (old) boiler has two external 24v transformers for a 5 zone system. I wired just as described, but my nest thermostat is only showing ~12 volts at the thermostat for the C wire. Do I need a new 24v transformer with more amperage? Thanks!
@JutanatuJ
@JutanatuJ Год назад
​@@PipeDoctor Any thoughts to why my thermostats would show ~12 volts for the C-wire, but a multimeter shows 28v across the R and the C? Thanks!
@amitsiyak7000
@amitsiyak7000 Год назад
1 no video
@bennymoz3091
@bennymoz3091 Год назад
Mikey fucking pipes!!! Thats the reason you are the fucking bossssss!!!! THE GOAT!!! 🐐🐐
@ItsTheCostanza
@ItsTheCostanza Год назад
You will make bank during hurricane season in Florida.
@ItsTheCostanza
@ItsTheCostanza Год назад
@@PipeDoctor Hurricane Mikey is coming
@patrickf310
@patrickf310 Год назад
Not in the trade. But I gotta say, after your channel popped up on my YT ( guessing cuz I’m in Nassau County? ) I’ve learned so much about HVAC. Besides that, this is my daily dose of education and comedy. I look forward to daily to seeing your videos Good Sir!
@ItsTheCostanza
@ItsTheCostanza Год назад
@@PipeDoctor you should donate your Mercedes Benz sprinter van to Steve Lav, he just said his truck is dead 💀
@claudioinga4364
@claudioinga4364 Год назад
You make me laugh at that that punch
@compactc9
@compactc9 Год назад
I'm not Jewish, but I definitely know about the Mohel! I just about chocked on laughter with that!
@stevelamm2366
@stevelamm2366 2 месяца назад
That mess looks just like what I have in my home at the moment. 3 zone boiler system with Honeywell zone valves. I want to redo it and your video was real helpful. Thanks! Are the two reds and yellows on a zone valve interchangeable for wiring purposes?
@shiprarao476
@shiprarao476 Год назад
liked a lot
@chrisjohns8041
@chrisjohns8041 Год назад
Great Video. 👍
@MedinaCliff
@MedinaCliff Год назад
U DA MAN!
@mayankbajiya5977
@mayankbajiya5977 Год назад
Very good
@myleshunnel3252
@myleshunnel3252 Год назад
Thank you again Mikey pipes. I enjoy all your videos and wish you the best. Happy new years and hope you had a great Christmas/hanukkah. You should just turn to the dark side and get rid of siri. Love you brother and I feel like your apprentice. I started 2019 in Wyoming after 18 years in the kitchen. #mikeypipesapprentice Keep on learning. Don't ask someone to do something you are not willing to do yourselfe.
@kisusola
@kisusola Год назад
Full support 🔥
@carllinton
@carllinton Год назад
Great educational a video👍🏾
@ashokmehta5272
@ashokmehta5272 Год назад
Soo nice video
@lokeshgurjar6396
@lokeshgurjar6396 Год назад
Keep it up
@SajidKhan-vw3em
@SajidKhan-vw3em Год назад
Well done
@sunilsaini2497
@sunilsaini2497 Год назад
Good ♥️
@arunsharma7841
@arunsharma7841 Год назад
Soo good
@sushilraja
@sushilraja Год назад
excellent job 🤟
@msbcas012
@msbcas012 Год назад
EXCELLENT!
@rajsolanki6865
@rajsolanki6865 Год назад
Fantastic
@jamesruane382
@jamesruane382 9 месяцев назад
Love the channel. Quick question. My WM boiler keeps short cycling. Any reasons why?
@PipeDoctor
@PipeDoctor 9 месяцев назад
Not enough load
@soufianemess7681
@soufianemess7681 10 месяцев назад
Great vdeo, thank you for your time for doing it! I was wondering if I send you a simple schematic with 2 valve zones (the 1361 of White Rodgers and the 672b of Motorola) would you be able to just validate it that is correct? Especially that I want to replace and old TStat for a wifi one that needs an extra wire which is C. Thank you
@travis1185
@travis1185 Год назад
Man you where making sense to me. Then towards the end you just started sticking wires without the explanation of why
@windellwalker7487
@windellwalker7487 Год назад
Exactly should have done a single zone
@richards5843
@richards5843 Год назад
In order for me to understand the wiring I would have to start with the thermostat and work my way down to the switches. Your wiring is still better than it was before, good job. Peter is learning so much from you because you are a great teacher and I can see you want Peter to succeed . What I would like to know is why are there two thermostats on one wall? Thanks.
@abm2958
@abm2958 Год назад
Probably hooked up to a secondary heat source like electric heat or an outdoor wood boiler.
@rickc9873
@rickc9873 Год назад
Great ! But I think I missed why two thermostats One for heat and one for AC ?
@verticallines212
@verticallines212 Год назад
correct the other therm for A/C only, sloppy therm install
@michaelhouser4673
@michaelhouser4673 Год назад
Can you do a video on wiring a taco sentry zone valve please
@rahulrastogi40
@rahulrastogi40 Год назад
Not bad
@aaronsabel
@aaronsabel Год назад
Very helpful, thanks. Question, if the top and 1st floor not heating how did plumbing contractor think changing one valve would fix it? Was the initial problem the commons on those two floor therms not matched up correctly?
@Keegeth
@Keegeth Год назад
I think they put the zone valve on the circulator to use as a flow check
@throttlebottle5906
@throttlebottle5906 Год назад
or possibly just for the end switch, but maybe both. at one point integrated flow checks were not a thing, so you'd need to use a relay box and flow check both. the other zone controller likely cannot switch both line voltage(for circ.) and low voltage end switch at once, or it's combined in a group of others. hard to say/guess without looking it all over. they may be stupidly running that circ. pump dead-headed by closing the zone valve and letting it run with the rest of the circs. and boiler.
@deepakajwani9563
@deepakajwani9563 Год назад
🔥🔥🔥🔥🔥🔥
Далее
PERFECT PITCH FILTER.. (CR7 EDITION) 🙈😅
00:21
Просмотров 3,4 млн
Purging Air From A Boiler System (Residential)
14:34
Просмотров 75 тыс.
Smart Meter Disaster!!
16:33
Просмотров 453 тыс.
18 Year Old HVAC Technician
12:48
Просмотров 110 тыс.
How a Zone Valve Works - Hot Water Heating
11:03
Просмотров 349 тыс.
Wire Y Plan System &  3 Port Valve Replacement
47:44
Просмотров 11 тыс.
PERFECT PITCH FILTER.. (CR7 EDITION) 🙈😅
00:21
Просмотров 3,4 млн