A short demonstration, on-site, of a Zs test carried out with a Kewtech KT63or KT63DL multifunction tester.

Опубликовано:

 

9 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 13   
@lloydmccooky9080
@lloydmccooky9080 2 года назад
JOHN THANKS . YOU ARE A PROFESSIONAL FOR SURE
@julianpearce218
@julianpearce218 2 года назад
Yesterday I posted requesting a video requesting a demonstration of the Ze test (in LOOP High mode) . I suggested that the KT63 should be used in 3-wire mode. THIS WAS WRONG and I have deleted my posts. I have since found the KEWTECH KT63 Operating manual that describes a 2-WIRE configuration for the test leads (Page 16) Basically join the Blue and Green leads together at the Probe/Croc-clip end. Also Note that the Operation Manual specifies on page 16 and page 18 to ONLY use the KT63 LOOP HIGH mode with a TWO WIRE configuration.
@julianpearce218
@julianpearce218 2 года назад
Hopefully not infringing any copyright here but I think this is necessary. KEWTECH KT63 Operating Manual pdf can be found here: docs.rs-online.com/63b7/0900766b8124513e.pdf
@danielokoro6685
@danielokoro6685 6 лет назад
The mains it’s on the ON position I guess As it’s a live testing,I’m just not sure Thanks
@simonb1996
@simonb1996 6 месяцев назад
Mine trips off Eaton RCBOs [and some others] when trying to do a No Trip test. Why?
@democracyforall
@democracyforall 3 года назад
You got three leads going out of the meter, where is the third connected?
@dmcolemanmarc647
@dmcolemanmarc647 4 года назад
Mine fires up a polarity warning whenever I try to test rcbo's, does it need an earth lead that the neutral also slots into for this test?
@zippymo672
@zippymo672 2 года назад
What if there is no rcd im an old installtion. Do you set it to high?
@AC400V
@AC400V Год назад
A pokaz wszystkich pomiarów? Prosze:)
@geoffball5803
@geoffball5803 4 года назад
I get hugely inaccurate Zs readings on the KT63 no trip setting, can only rely on the high current test
@Kewtechcorp
@Kewtechcorp 4 года назад
Hi Geoff, have you been in touch with Kewtech about this? 01494792212.
@alang7846
@alang7846 3 месяца назад
This video seriously misrepresents the time this thing takes to do a no-trip loop test. Each time you connect it to a circuit it needs to go through the pre-test (approximately as shown here from 1:11) before it will do a loop test. If you set it to "hands free" it will do the sequence automatically. Otherwise you need to press the test button in the middle of the process. Minimum 9 seconds from connection to getting a reading.
Далее
KT66DL Introduction Video
18:47
Просмотров 8 тыс.
Domestic EICR walkthrough
46:32
Просмотров 31 тыс.
ДОКАЗАЛ ЧТО НЕ КАБЛУК #shorts
00:30
Просмотров 906 тыс.
Новый уровень твоей сосиски
00:33
Dropping In from the Clouds 🌁
00:17
Просмотров 1,3 млн
The Kewtech KT65DL | Multi Function Tester. (42)
34:37
Earth loop impedance test, ZE test
4:56
Просмотров 67 тыс.
RCD Testing with a KT63
2:30
Просмотров 30 тыс.
Ze and PFC Electrical Tests on a 3 Phase Board | PTT
6:23
Loop Impedance Testing
15:04
Просмотров 289 тыс.
Ring Final Circuit Testing (Domestic)
14:22
Просмотров 38 тыс.
ДОКАЗАЛ ЧТО НЕ КАБЛУК #shorts
00:30
Просмотров 906 тыс.