Welcome to my channel! Here I post all about my fire systems and systems I see in the field! There are even some Field testing videos up! If you like what you see please consider subscribing! Thanks for viewing!
Edwards EST-3 Demonstration
4:02
Месяц назад
Hotel Fire Alarm Test
2:50
3 месяца назад
Notifier Fire Alarm System Test 27
3:49
5 месяцев назад
Silent Knight "6808" Shenanigans Part 2
10:28
5 месяцев назад
Silent Knight "6808" Shenanigans Part 1 of 2
11:00
5 месяцев назад
Gamewell-FCI S3 Demo
7:48
6 месяцев назад
NEW Fire Alarm System Test 26
9:03
6 месяцев назад
Notifier System 5000 Demonstration
6:25
7 месяцев назад
Notifier Fire Alarm System Test 24
1:06
8 месяцев назад
2024 New Years Fire Alarm Sound Off
2:41
9 месяцев назад
Fire-Lite MS-9600UD Resurrection
2:22
9 месяцев назад
Honeywell Vista 32FBPT
2:42
9 месяцев назад
Notifier Fire Alarm System Test 22 (New Alarm)
1:34
10 месяцев назад
Silent Knight 6820EVS Test
4:11
11 месяцев назад
Siemens Cerberus Pyrotronics MXL-IQ Test
6:06
11 месяцев назад
Siemens FC922 Fire Alarm System Test (wip)
5:51
11 месяцев назад
Simplex 4007ES Fire Alarm Test
2:51
Год назад
Siemens FC922
8:53
Год назад
Fire Alarm System Test 20
9:04
Год назад
Duct Detector Testing
4:22
Год назад
Notifier NFS2-640 & NCA-2 Test
4:20
Год назад
Fire Alarm Test #19 + Updates
7:50
Год назад
Комментарии
@FanFanFan777
@FanFanFan777 5 часов назад
How did you wire that system by yourself? Im curious?
@patcarbone1753
@patcarbone1753 8 часов назад
Looks awesome!!
@Fire-Lite457
@Fire-Lite457 13 часов назад
You got a microphone for your DVC. 👍
@OklahomaStateSirens
@OklahomaStateSirens 14 часов назад
What’s the primary recall for?
@FireTech7
@FireTech7 14 часов назад
That was just a relay module tripping the other system. The writing was on it before I got it
@terrellstorms
@terrellstorms 5 дней назад
Can these 50 point panels be programmed fully through the menu or do you need a laptop?
@FireTech7
@FireTech7 4 дня назад
Laptop needed, very limited through the keypad
@ZackKilleen
@ZackKilleen 5 дней назад
That sounds like a true alert
@FireTech7
@FireTech7 4 дня назад
Same horn pretty much
@clips0292
@clips0292 7 дней назад
Do you have a video disabling the nacs for this panel?
@OklahomaStateSirens
@OklahomaStateSirens 10 дней назад
Could you just plug it into an outlet? Or did it have to be hardwired into the breaker box?
@FireTech7
@FireTech7 9 дней назад
Yes, all of my panels are just plugged into the outlets
@dantesparda-b7c
@dantesparda-b7c 12 дней назад
Lee Michelle Hall Betty Robinson Helen
@firealarm421
@firealarm421 15 дней назад
How did you do 2 wire audible silence? I have a fire lite es50x but mine doesn’t support 2 wire audible silence. I can’t fine sync mute anywhere.
@firealarm421
@firealarm421 15 дней назад
If you put the 5208 in fire drill mode, does that activate the dialer
@FireTech7
@FireTech7 15 дней назад
If the dialer is programmed it would send a fire drill signal
@Robloxsafetyalarms
@Robloxsafetyalarms 15 дней назад
Yo I visit you're roblox group
@Txdcblues
@Txdcblues 16 дней назад
Never knew these could work without SBUS
@LA_roleplay_channel
@LA_roleplay_channel 18 дней назад
The first one is my schools fire alarm one
@hariharasudhane5432
@hariharasudhane5432 20 дней назад
Sir detector alarm valve and pre alarm valve how to reset?
@xuemingxia
@xuemingxia 22 дня назад
Simplex is best, only.
@luannemikos9816
@luannemikos9816 22 дня назад
Dose the panel need to be normal for it to activate
@FireTech7
@FireTech7 21 день назад
No
@turyanazrogluclilov9045
@turyanazrogluclilov9045 22 дня назад
Hi Sir, could you please any advise . In my alarm panel have one trouble : No power supply inst . power supply is ok, i made reset also, still showing this strouble.
@FireTech7
@FireTech7 22 дня назад
What's the slc address of the power supply
@jaydeniverson3373
@jaydeniverson3373 23 дня назад
I was thinking of saving up and buying the Silent Night 6820EVS. Is it a good fire alarm panel and worth $3,500.
@FireTech7
@FireTech7 22 дня назад
I would never in a million years spend that much on this panel, it's cool and all but no where near worth that price. I've had a few problems with them lately
@DJ-Legend
@DJ-Legend 24 дня назад
There is a way to disable the back door passcode.
@FireTech7
@FireTech7 23 дня назад
How?
@curtisciampo137
@curtisciampo137 27 дней назад
How do you tie in speaker strobes to the ES50x
@FireTech7
@FireTech7 27 дней назад
You get a voice panel, that's how
@IanGSully
@IanGSully Месяц назад
I actually did myself a FireLite ES-50X panel a couple of weeks ago. I am going to install it in a garage building. However I am short on one smoke detector because someone jacked it off my porch. And then I am getting 3 more alarms later on. Currently I have two System Sensor SpectrAlert Advances, one is a P2W, and the other is a P2WK. Then later I am getting two SCWLs and one PC2WL. Then I am going to have a conventional FireLite BG-12L being monitored by an MMF-300 monitor module
@FireTech7
@FireTech7 Месяц назад
Neat
@jacksonicecreamtruckrailfa1370
@jacksonicecreamtruckrailfa1370 Месяц назад
Was this at Walt whiteman mall in Huntington ny
@FireTech7
@FireTech7 Месяц назад
No
@gi7490tiger
@gi7490tiger Месяц назад
How to troubleshoot a pull station with voltmeter?
@FireTech7
@FireTech7 Месяц назад
What are troubleshooting?
@TemiAbiel
@TemiAbiel Месяц назад
Great content. Keep the good work up.
@Loganetics1
@Loganetics1 Месяц назад
No way bro just spawned in an EST3
@pfefferwal
@pfefferwal Месяц назад
what company is this logo with the barcode?
@FireTech7
@FireTech7 Месяц назад
It's called building reports scan series. We use it for inspections
@iashbanen
@iashbanen Месяц назад
Trouble maker panel
@achannelwithnopurpose1977
@achannelwithnopurpose1977 Месяц назад
I actually have recently started working for an EST dealer called Southern Signal. I’ve learned a lot about EST products and have actually messed around with an EST4. A video of that is on my channel. EST is actually not bad after learning about how it works. The trick is really knowledge and then it actually becomes decent if not good. The quirks become issues really when not installed or serviced correctly and with the right equipment. Here’s a tip for you: Buy a SIGA-HDT for the signature series devices. You can use it to make troubleshooting signature series devices so much easier. Plus, it can program individual device addresses and do a plethora of functions without needing a control panel. I have one and made great use of it so far.
@patcarbone1753
@patcarbone1753 Месяц назад
Great video!
@NewEnglandAviaton987
@NewEnglandAviaton987 Месяц назад
HR
@tornado0833
@tornado0833 Месяц назад
Do the hotel rooms have Low frequency sounders
@FireTech7
@FireTech7 Месяц назад
Nah just normal sounder bases
@ActiveDirectoryUAC
@ActiveDirectoryUAC Месяц назад
How do u power up your simplex 4007 can u take a picture & send it to me I just bought my panel today trying to figure how to power it up.
@omarionscott4368
@omarionscott4368 Месяц назад
Not good
@DJHazemBrewog
@DJHazemBrewog Месяц назад
This is the power of notifier DVC systems, you can literally modify everything even MXL-V audio tone. This is one of the best voice evac system on E-Commerce.
@FireTech7
@FireTech7 Месяц назад
Agreed, it's awesome
@successforpoor3369
@successforpoor3369 Месяц назад
How can i know more information about fa panel
@successforpoor3369
@successforpoor3369 Месяц назад
Hii bro ,i am a fire alarm technician but l want to know more information about fa panel .
@MR33EE
@MR33EE Месяц назад
Bro he has to use his middle finger 💀
@ratneshkumar996
@ratneshkumar996 Месяц назад
Are you supply the panel?? Required the 5 panel from India Delhi
@FireTech7
@FireTech7 Месяц назад
No
@Talonicipaint
@Talonicipaint Месяц назад
Could you tell me what sweatshirt you were wearing
@manisharya5475
@manisharya5475 Месяц назад
Atleast hold your camera properly
@FireTech7
@FireTech7 Месяц назад
Does that make you feel cool saying that?
@ConnorMartchenke
@ConnorMartchenke Месяц назад
Why did you have to copy Simplex, Notifier??
@unerringsalt6325
@unerringsalt6325 2 месяца назад
Did you get permission to do this?
@FireTech7
@FireTech7 2 месяца назад
I am a fire alarm service technician. Besides that point, though, what kind of person would go out of their way, troubleshoot a notification circuit, bring a 6-foot ladder with them, and verify the problem for no reason? And how would that said person do it without permission
@unerringsalt6325
@unerringsalt6325 2 месяца назад
@@FireTech7 it's because I didn't know
@unerringsalt6325
@unerringsalt6325 2 месяца назад
Also was the alarm replaced with a new one?
@FireTech7
@FireTech7 2 месяца назад
Most likely, I was not the one who came back to replace it though
@graememcrae9284
@graememcrae9284 2 месяца назад
I'm programming the dvc-kd in vft, trying to figure out how to page individual speaker circuits on a daa2 amplifier. Do I map control to the local microphone PAM point or is it done another way? Any help is appreciated
@satheeshchandran23
@satheeshchandran23 2 месяца назад
Hai brio trigga panel if any detector is activating but sounder not working but if press evacuation that time its working why
@FireAlarmsAndTrains
@FireAlarmsAndTrains 2 месяца назад
Hows that monitor getting power? I have mine powered by the nacs and slc
@FireTech7
@FireTech7 2 месяца назад
Monitor modules are not supposed to get power. They only need SLC. I think you're referring to a control module
@FireAlarmsAndTrains
@FireAlarmsAndTrains 2 месяца назад
@FireTech7 I'm using a relay module for two conventional panels, and 2 two wire detector modules for the two conventional bg12's and the conventional I3 in the panel closet.
@LukeDoyle-fl4wd
@LukeDoyle-fl4wd 2 месяца назад
different fire alarms in one building, love it!
@FireTech7
@FireTech7 2 месяца назад
Multiple buildings
@winneric
@winneric 2 месяца назад
No bushing on the box?
@FireTech7
@FireTech7 2 месяца назад
Box was removed entirely afterward. For some reason, I paid no attention to the single gang box that was in the wall already