Welcome to my channel! Here I post all about my fire systems and systems I see in the field! There are even some Field testing videos up! If you like what you see please consider subscribing! Thanks for viewing!
Hi Sir, could you please any advise . In my alarm panel have one trouble : No power supply inst . power supply is ok, i made reset also, still showing this strouble.
I would never in a million years spend that much on this panel, it's cool and all but no where near worth that price. I've had a few problems with them lately
I actually did myself a FireLite ES-50X panel a couple of weeks ago. I am going to install it in a garage building. However I am short on one smoke detector because someone jacked it off my porch. And then I am getting 3 more alarms later on. Currently I have two System Sensor SpectrAlert Advances, one is a P2W, and the other is a P2WK. Then later I am getting two SCWLs and one PC2WL. Then I am going to have a conventional FireLite BG-12L being monitored by an MMF-300 monitor module
I actually have recently started working for an EST dealer called Southern Signal. I’ve learned a lot about EST products and have actually messed around with an EST4. A video of that is on my channel. EST is actually not bad after learning about how it works. The trick is really knowledge and then it actually becomes decent if not good. The quirks become issues really when not installed or serviced correctly and with the right equipment. Here’s a tip for you: Buy a SIGA-HDT for the signature series devices. You can use it to make troubleshooting signature series devices so much easier. Plus, it can program individual device addresses and do a plethora of functions without needing a control panel. I have one and made great use of it so far.
This is the power of notifier DVC systems, you can literally modify everything even MXL-V audio tone. This is one of the best voice evac system on E-Commerce.
I am a fire alarm service technician. Besides that point, though, what kind of person would go out of their way, troubleshoot a notification circuit, bring a 6-foot ladder with them, and verify the problem for no reason? And how would that said person do it without permission
I'm programming the dvc-kd in vft, trying to figure out how to page individual speaker circuits on a daa2 amplifier. Do I map control to the local microphone PAM point or is it done another way? Any help is appreciated
@FireTech7 I'm using a relay module for two conventional panels, and 2 two wire detector modules for the two conventional bg12's and the conventional I3 in the panel closet.