Комментарии
@ahmedomar7743
@ahmedomar7743 14 дней назад
Great video, can this work for a solar geyser?
@bolandsystems9707
@bolandsystems9707 14 дней назад
1. If the temp probe can be alstuck on where the heat of the water can be measured. 2. It then provides a relay for any power to be switched on/off via a combo of time & temp.
@ahmedomar7743
@ahmedomar7743 14 дней назад
Thanks sir what putty glue was used?
@bolandsystems9707
@bolandsystems9707 14 дней назад
​@@ahmedomar7743Den Braven Glue Screws
@GGLMalan
@GGLMalan 23 дня назад
Boer maak 'n plan! Clever my friend. Congratulations. We need innovators like you!
@KamenKr
@KamenKr 2 месяца назад
What does this Smart text mean?
@nielkotze
@nielkotze 3 месяца назад
Hi. Regarding your setup that allows a 2nd geyser to be heated if the 1st one is already hot: What is the name of the "relay" that you refer to in your video? ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-fIXeK_-b12c.html I am currently running my geyser on SmartLoad. No issues there. On a sunny day, my batteries are fully charged and my geyser is hot before midday. The rest of the day, my panel power is mostly wasted. I was considering powering an additional geyser using your "relay" setup. Perhaps you have more information on how it works or could supply the part name or a link that explains how to set it up. Thank you in advance.
@bolandsystems9707
@bolandsystems9707 3 месяца назад
Hi Niel. The relay is a common DIN rail 20A relay powered by 220Vac. Most electrical suppliers should have one. (CHNT model NCH8-20/11) My Smart load goes to both, but the 2nd geyser's power 1st goes through the relay's N/C. That means, when the Smart Load power switches the 1st geyser on, it also powers the relay to open the N/C contact to the 2nd geyser. When the 1st geyser's thermostat switches off, the power to the element is cut. The relay is therfor wired onto the element of the 1st geyser. I also added DIN rail LEDs to indicate which one is on. 1 - connected to feed from element to relay 2 - connected to feed to 2nd geyser's tripswitch (better to connect to it's element input) You should strongly consider a 200l geyser & 2kW element (with screw connectors on element) as your spare geyser BEFORE your main geyser's input. Water flows through 2nd geyser to 1st (main) geyser The main geyser's temp is regulated (50°C) and the spare geyser is dependant on excess solar, set to 70°C (fluctuating) So add a wifi timer to your main geyser, preferably via an auto change-over (SL or timer input to power geyser 1) If it rains, the timer will switch on & heat the main geyser. 90% of the time your SL will heat both. Let me know if you need a sketch.
@nielkotze
@nielkotze 3 месяца назад
@@bolandsystems9707 Hi. Please send me a sketch if you can 🙂
@fikridusakabinoglu2744
@fikridusakabinoglu2744 4 месяца назад
Very late notification thank you for sharing video
@haniefbhat6695
@haniefbhat6695 4 месяца назад
Whats the setting all my noti8fcation are on even the calling notification but my phone isnt ringing
@hssnbt6557
@hssnbt6557 3 месяца назад
That’s Same problem coming to mee
@weforfix
@weforfix 25 дней назад
Same
@vusimuzivilakazi4563
@vusimuzivilakazi4563 4 месяца назад
Good day, can I get your contact number I want to connect a system that can run a geyser and I need some advice.
@SafeAndSecureAlarmsTV
@SafeAndSecureAlarmsTV 5 месяцев назад
Hi love these videos. What is your experience with the thermals vca detection in moderately dense folioage - pine trees and large bushes. Does it still detect human intrusion? Thanks
@bolandsystems9707
@bolandsystems9707 5 месяцев назад
Hi. No, it detects heat, therefor it needs a clear line of sight. A cleared strip of about 2m is usually requested outside the fence. Max. & min. sizes must also be tested near & far
@marcoferreira3350
@marcoferreira3350 5 месяцев назад
How to program the micro sd card to work? and take the prints
@bolandsystems9707
@bolandsystems9707 5 месяцев назад
The SD card is in the monitor. In the programming on the monitor, you can format and set it up. You have to tick the box in programming to do recordings
@marcoferreira3350
@marcoferreira3350 5 месяцев назад
Is there a video demonstrating this process ?@@bolandsystems9707
@ChidoriTensen
@ChidoriTensen 5 месяцев назад
Does it work vertically?
@mohamadrashid5854
@mohamadrashid5854 5 месяцев назад
Hello i have a question I also use smart load on my deye 6kw inverter I put my conditions for 50% 55% for the battery and the 1000w for PV For the on condition it is doing alright (when pv is higher than 1000w and lithium battery it kicks on) but for the off condition it only kicks on when the battery is below 50% and ignores the PV condition Can you explain that to me please
@sakkieplakkie204
@sakkieplakkie204 5 месяцев назад
Good day Nice Installation. Do you mind sharing your drawings please. Regards
@JAMESJAMES26000
@JAMESJAMES26000 6 месяцев назад
Does it have motion detection?
@bolandsystems9707
@bolandsystems9707 6 месяцев назад
No, it will drive you crazy. You can add the image to your NVR with very basic motion detection recording, but is seldom needed. With an SD card in the monitor it records: 1. A picture snapshot of the one ringing 2. A voice message can be left if no-one is home.
@marcoferreira3350
@marcoferreira3350 5 месяцев назад
@@bolandsystems9707 This configuration is already the factory default. Or do we have to configure some setting for this?
@bolandsystems9707
@bolandsystems9707 5 месяцев назад
No. Only recording a snapshot on ringing. You can pull in the gate station's camera on a NVR, with motion detection, but currently it is only very basic motion detection (not AI)
@ThePonderi
@ThePonderi 6 месяцев назад
You should consider more panels they are getting cheaper.. especially that you have 2 geysers. Solarways warehouse have better prices for the panels.
@ThePonderi
@ThePonderi 6 месяцев назад
Very inteeresting. How lon do you heat up a single geyser? I understand they are 2kw ?
@bolandsystems9707
@bolandsystems9707 6 месяцев назад
It depends on how empty (cold) it was. If almost fully empty (cold) a 150l will take 1h30min on 3kW. If heated with solar power, I turn it up to 60°C to last till the morning. I have a 200l with 3kW element in, but use little water to pre-feed a regulated temp geyser (Harver 30l induction) If fully empty, I guess a 200l, 2kW will take around 3h. With enough sun, it's ideal. Smart Load starts around 10:30am (summer) You then have until 4pm to heat the geyser (4.4kW panels as minimum)
@ThePonderi
@ThePonderi 6 месяцев назад
Excellent setup on your geysers...
@schunkelndedschunke6914
@schunkelndedschunke6914 6 месяцев назад
Well done. Greetings from Austria.
@bolandsystems9707
@bolandsystems9707 6 месяцев назад
Thanx.
@ulasvergili3160
@ulasvergili3160 6 месяцев назад
Bok😂
@dieselodesa
@dieselodesa 6 месяцев назад
My Deye invertor, Smart Load "on" only 100% battery. :(
@bolandsystems9707
@bolandsystems9707 6 месяцев назад
You can set the SOC% for ON & OFF at any %. I choose 90% On, because I want some reserve charging left over for the battery. Once my Volta reaches 100%, any load > PV will let the SOC drop with only a trickle charge feeding it (will not charge to 100% again before it drops below 90%)
@dieselodesa
@dieselodesa 6 месяцев назад
@@bolandsystems9707 you can't do less than 100% on my deye. The inverter does not allow you to change this setting. That's why SMART doesn't start for me. And in general, everyone praises Deye, but I don't like it, there is a lot in it, but it doesn't work, or it doesn't work normally.
@nielkotze
@nielkotze 3 месяца назад
​@@dieselodesaMy Deye 5KW inverter is the same. The ON battery SOC % cannot be changed. I ran into the following issue (but there is a workaround): My standard backup load is around 500W and my geyser is 2000W. I figured the logical "Power" setting under SmartLoad should be 2500W, which can run backup load and smartload without needing the battery to help. On heavy cloudy days, I only reached 2500W solar out much later in the day. By then, the battery managed to recharge back to 100% with less than 2500W available solar power. The BMS on my Volta Stage 1 batteries ( 2 of them in parallel) does not keep the battery at 100% SOC. Not long after reaching 100% SOC, they will drop down to 99.9% SOC. And now for the issue: When solar output did reach 2500W, my batteries were 99.9% SOC and SmartLoad would not turn on as the batteries are not 100% SOC. The workaround was to change the "Power" value to a lower value (1500W). Now, when the batteries do reach 100% SOC, SmartLoad turns on because the "Power" value is met. The drawback is that the battery will need to supplement power if there is less than 2500W. If there is for example 2000W solar power available, the inverter draws 2000W from the panels and 500W from the battery. This is not a problem in general as the battery will only drop to the OFF SOC % setting in a worst case scenario. In most cases, I do draw a bit of battery power until solar output reaches 2500W. I hope this helps.
@bolandsystems9707
@bolandsystems9707 3 месяца назад
Depending on your firmware, when you choose Smart Load, the the % appears under Micro Inverter. Change the % settings there. (When you tick Micro inverter, you will see the % changes, thus those blocks are used for both SL & MI... confusing, I know)
@bolandsystems9707
@bolandsystems9707 7 месяцев назад
Look for the full video from PIPL
@LaxmanLaxman-sf5fn
@LaxmanLaxman-sf5fn 7 месяцев назад
Please tell me the configuration
@mrmacknackers
@mrmacknackers 7 месяцев назад
Can i call you ? Setting this up
@husainalli
@husainalli 8 месяцев назад
What will a geyser control box setup like this cost?
@bolandsystems9707
@bolandsystems9707 8 месяцев назад
Hard to say. I do not know your setup. Ideally: a 2nd 200l geyser connected to the Smart Load output (electrician) replacing the 4kW element with a 2kW (plumber). Add an auto change-over switch & smart wifi timer. Optional: add relay powered by main geyser's element to switch between 2 geysers. Electricals +-$300 (R6000) 2nd geyser +-$600 (R12000) You should not need to use grid power ever again, other than cloudy rainy days. Temp is much more controlable than solar geysers which tend to overheat
@husainalli
@husainalli 8 месяцев назад
@bolandsystems9707 thanks. How can I get hold of you?
@Vkara01
@Vkara01 5 месяцев назад
Where did you get the Changeover switch that has the WiFi capability?
@bolandsystems9707
@bolandsystems9707 5 месяцев назад
@@Vkara01 no, the WiFi switch is left of the auto-change over. It provides grid power to the change over if SL was not enough
@dannyvermeulen8570
@dannyvermeulen8570 8 месяцев назад
Can you please upload some videos on the variety of HIKVision Ax Pro products? I am not finding many videos online. Ive just started to install some of these products and will currently run two systems side by side until i have enough products of the HIKVision Ax Pro.
@bolandsystems9707
@bolandsystems9707 8 месяцев назад
Hi Danny. You 1st have to see which products are available locally. The outdoor & indoor PIRs, siren(ind/outd), remotes, panic buttons, magnets, relays, transmitters for 3rd party sensors should be available. You can then use their TX in any other wireless sensor like Optex/Takex if Hik does not have a simular product. You loose a few nice features (walk test), but nothing serious. As installers we work with the Hik-PartnerPro App for setup & management, but you should be able to do it all on Hik-Connect as well (or download HPP) It is pretty intuative.
@fernandobainotti1084
@fernandobainotti1084 8 месяцев назад
Good Job! 👏
@malikmansoor4960
@malikmansoor4960 8 месяцев назад
Could you please share alarms
@malikmansoor4960
@malikmansoor4960 8 месяцев назад
Please share all alarms how do they sound
@bolandsystems9707
@bolandsystems9707 8 месяцев назад
Alarms?
@Maxol744
@Maxol744 9 месяцев назад
What camera model is this?
@bolandsystems9707
@bolandsystems9707 8 месяцев назад
Sorry for the late response... It is the DS-2TD2628-10/QA
@marcoferreira3350
@marcoferreira3350 9 месяцев назад
Hello, good evening, I purchased an Intercom kit (video intercom) from Hik Vision of the Model - DS-KV6113-WPE1(C), I have already programmed it completely but there is a situation missing that has to do with intrusion or movement detection. I have already inserted a micro SD card and still the device does not recognize it or says that there is no card inserted. Because my goal is when the doorbell detects movement I get notified and I save an excerpt of that moment. If you need to send some prints to show something, say so. Waiting for reply Thank you,
@bolandsystems9707
@bolandsystems9707 9 месяцев назад
The monitor should accept an SD card (insert right way round). If enabled in its settings, it will record snapshots of visitors and they can leave a message when there is no answer.
@marcoferreira3350
@marcoferreira3350 9 месяцев назад
Olá, boa noite eu comprei um kit de Intercom (vídeo porteiro) da Hik Vision do Modelo - DS-KV6113-WPE1(C), eu já o programei completo só que falta uma situação que tem haver com deteção de intrusão ou movimento. Eu já coloquei um cartão micro SD e mesmo assim o aparelho não reconhece ou diz que não tem nenhum cartão inserido. Porque o meu objetivo é quando a campainha detetar movimento ser notificado e guardo um excerto desse momento. Se for necessário enviar alguns prints para mostrar alguma coisa diga. Aguardo Resposta Obrigado,
@Dolly-Days
@Dolly-Days 10 месяцев назад
Very nice setup! I know I’m just the 8 cameras I have, it was about $2,000
@talisonzambonbreitenbach2961
@talisonzambonbreitenbach2961 11 месяцев назад
What is the name of the app ?
@bolandsystems9707
@bolandsystems9707 8 месяцев назад
Hik-Connect 6 - for Hikvision
@yacoutraore9926
@yacoutraore9926 11 месяцев назад
please the name of the application😢
@yacoutraore9926
@yacoutraore9926 11 месяцев назад
please the name of the application
@michaelh5722
@michaelh5722 Год назад
Really enjoyed learning some extra tips I can do with my own installation. People in my part of the world don’t take security as seriously as this.
@bolandsystems9707
@bolandsystems9707 Год назад
Yeh, we sit with mostly petty crime committed by people who will steal whatever they can get to pawn for food. That then escalates to cable theft or any other copper (metal) product, to sindicates aimed at electronic equipment.
@Quadraphoria
@Quadraphoria Год назад
Our cameras and lights were mounted similarly, however the camera and light was stollen. We had to reinstall inside the yard with electric fence and perimeter beam
@nayakacreativity3639
@nayakacreativity3639 Год назад
How much storage did you use to record all of that cameras ?
@bolandsystems9707
@bolandsystems9707 Год назад
4TB. Triggers are accurate, so not to many unneccesary recordings. More than a month's rec.
@jameswells3657
@jameswells3657 Год назад
Please tell me what speaker you are using. I would put the speaker separate from the camera so that attention is not directed towards the expensive camera, which could be vandalized.
@bolandsystems9707
@bolandsystems9707 Год назад
TOA 10W, 15W 8ohm combined with an amplifier PCB placed in a small water tight box so we can access volume settings. 100W 12V amp PCB with vol. pod (TOA has a 12V powered horn, but I find this PCB better & cheaper) Other cheaper PCBs don't have a pod. www.robotics.org.za/XH-M542?search=100w%20amp
@bolandsystems9707
@bolandsystems9707 Год назад
Inwill be posting a video of our latest project with the newer QA-model, combined with DS-2T46G2-ISU/SL Acusense cameras, horn speakers, 4-button IP video intercom, gate motor with FLUSS Bluetooth App triggered gate, UPS with small LiFePO4 battery (change-over period till generator kicks in) We had to add 48V batteries to one PoE Dahua rugged switch, which is not on the UPS. (PFS3106-4P-60)
@alroylewis1603
@alroylewis1603 Год назад
Woow love the set up question the external speaker are they 12 volt r 120 volt
@bolandsystems9707
@bolandsystems9707 Год назад
12Vdc. See comment higher up for info
@allplayza
@allplayza 2 года назад
Lyk goed ! Sien Eskom by die hek @10:18....jou krag af?😄
@amirm1553
@amirm1553 2 года назад
Great video! Whats the detection range on that thermal cameras and what modell do you use?
@MrBoomin
@MrBoomin 2 года назад
These seem to be Hikvision thermal cameras and set up
@bolandsystems9707
@bolandsystems9707 Год назад
Sorry for late response... The new bi-spectrum QA-models spec 77m, but we don't push past 60m. You need around 8-10m deadspot coverage under each camera by the previous camera overlapping. DS-2TD2628-10/QA www.hikvision.com/africa/products/Thermal-Products/Security-thermal-cameras/heatpro-series/ds-2td2628-10-qa/
@bluecavemen
@bluecavemen 3 года назад
Hi I been going over this in my head. I want to purchase this doorbell (DS-KV6113-PE1 Door Station). I want to connect this to my iPad. Which would be mounted to my way using PoE. I figure this would be cheaper and very modern look to my house. I want to connect all two devices using PoE. But my question I don't see any videos about how easy the apps would be to download it on my iPad to connect to the doorbell. Do you have any video on this ? If so this be very very helpful.