Here I talk about possible causes of backdrafting and the signs you can look for to see if you have a backdrafting issue in your home via water heaters or HVAC systems. Backdrafting is the reverse flow of gas in the flues of fuel-fired appliances that results in the intrusion of combustion byproducts into the living space. This is a serious issue as it could cause harm or death to the occupants via carbon monoxide poisoning.
#hvac #backdraft #hvacmaintenance
-------------------------------------------------------------------------------------------------
Website: rigidinspections.com/
Blog: rigidinspections.com/articles/
Facebook: / rigidinspect. .
Instagram: / rigidinspec. .
Twitter: / rigidinspection
Zac Knoblauch CMI, ACI
IL License: 450.011629
Rigid Inspections, LLC
636-614-3234
Master Certified, ASHI Certified, serving St. Louis County and Saint Charles County.
Free Thermal Imaging included with every inspection.
_____________________________________________________________
**TOOLS I USE FOR HOME INSPECTIONS**
Gear Light Flashlights: amzn.to/3q4zAAO
Klein Tools Receptacle Tester: amzn.to/2MW2MbJ
Spectora Inspection Software: www.spectora.com/
GVS Elipse P100 Respirator: amzn.to/3EvQYT7
GVS Hard Carrying Case: amzn.to/3bqo3mR
GVS Elipse P100 Filters: amzn.to/2ZH6pc8
Headlamp for attics and Crawls: amzn.to/3GI9FF5
Xtend & Climb 15.5ft Ladder: amzn.to/3CEIs3F
Xtend & Climb 15.5ft Ladder: amzn.to/3GNcZyu
Werner 2ft Step Ladder: amzn.to/3jZbweV
AWP 15" Tool Bag
Flir e8 Thermal Camera: amzn.to/2ZLunmm
Flir c3x Thermal Camera: amzn.to/2ZLfZuY
Craftsman 4ft Level: amzn.to/3mDbtHm
Dewalt 20v Screwdriver: amzn.to/3rpFsCi
Extech Moisture Meter: amzn.to/3rqRzie
Klein Voltage Tester: amzn.to/3oSF7WM
Craftsman 25ft Tape Measure: amzn.to/2MFgQ9R
Sperry 240v+ Receptacle Tester: amzn.to/3oSe7Xx
Smoke Detector Extendable Tester Pole: smdetpole.com/
Extendable Magnet: amzn.to/31k4r1X
Extendable Mirror: amzn.to/3w8WqIB
Collapsible Cup: amzn.to/3CiiiUv
WORKPRO Foldable Utility Knife: amzn.to/3mBliWj
Wearable Carbon Monoxide Detector: amzn.to/3pYZW7c
General Tool Combustible Gas Detector: amzn.to/3nUJMcm
DJI Mavic Air 2 Drone: amzn.to/3jZMyw0
Johnson Roof Level and Slope Gauge: amzn.to/3ByFQ60
Dewalt Driver Bit Set: amzn.to/2ZW3WL7
Extech Circuit Load Tester: amzn.to/3BEub5C
UEI Pocket Folding Thermometers: amzn.to/3BHlzeB
Rubber Drain Stoppers: amzn.to/2ZLXt4Y
Dupont Disposable Tyvek Suits: amzn.to/3mDNRST
Mechanix Disposable Gloves: amzn.to/3GKjYbO
Tub-O-Towels Wipes: amzn.to/3EGwvLg
Craftsman 2.5 Gallon Shop Vac: amzn.to/2YalSAZ
Airthings Corentium Pro Radon Monitors: www.airthings.com/pro
Amazon Tripods: amzn.to/3CEremU
Mold Air Sampling Kit: amzn.to/3CIZYne
Water Pressure Test Gauge: amzn.to/3jZmmBJ
Disposable Shoe Covers: amzn.to/3q0Ol7H
4ft Water Hose: amzn.to/3GLBADR
WORKPRO 20pc Socket and Ratchet Set: amzn.to/3GJhjPq
Racket Ball: amzn.to/3k2sJEd
Electrical Tape: amzn.to/3nVGztn
Needle Nose Plyers: amzn.to/3nOZcyZ
As an Amazon Associate I earn from qualifying purchases.

Опубликовано:

 

10 дек 2022

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 30   
@Number11FS
@Number11FS Год назад
Please continue to upload informational videos like this. You’re channel is a hidden gem on RU-vid that will take off eventually
@asiakevin
@asiakevin 5 месяцев назад
Knowledge is power. Thank you
@monarokilla
@monarokilla Год назад
Nice work man 😉
@jamesrecknor6752
@jamesrecknor6752 4 месяца назад
Excellent
@takearidewithme3589
@takearidewithme3589 Год назад
You are spot on in your diagnosis. The flue being too close to the roof probably isn’t harming this unit I realize it’s not code. We always line the chimney with a 4” liner when pulling out an 80% furnace and installing a 90%. The return needs to be blocked off and the furnace should have the air intake put to the outside.
@mts7274
@mts7274 Год назад
If a venting flue is installed to go up and through the roof, it will always be 'too close' to the roof. Also, isn't this guy in the basement of the home he's looking at in this vid?
@Margi183
@Margi183 Год назад
@@mts7274 What's your point tho?
@mts7274
@mts7274 Год назад
@@Margi183 What's your elemental implication?
@ScubaCat3
@ScubaCat3 Год назад
there should be enough makeup air in that size room. I'd take out that return duct at the bottom though for sure.
@tedlahm5740
@tedlahm5740 Год назад
Makeup air drawn from the basement? Unbelievable install.
@ScubaCat3
@ScubaCat3 Год назад
I think the main issue is the immediate near-90 and then that long 3 inch horizontal run. Not nearly enough vertical there right off the top. There should be enough makeup air in that size room to accommodate although that return duct at the bottom of the stack isn't helping that situation either.
@ericmichaud3331
@ericmichaud3331 8 месяцев назад
Major one is the size of the exhaust venting. Those flies need to be appropriately sized to the appliance and 4” into that much larger flue can cause issues of no draft especially when cold out
@HybelFever
@HybelFever Год назад
How do you remember all this information? its just crazy to me that you know all this :D Are you ever going to make a video about how to become/what its like to be a inspector?
@rigidinspections
@rigidinspections Год назад
Just repetition engrains it I guess lol. I can make a video like that, I’ll put it on a list of to do’s
@HybelFever
@HybelFever Год назад
@@rigidinspections yeah makes sense😅🤝🏻 maby you also can tell som intresting storys too, i bet you have seen some wild shit!
@Michael-cr4gq
@Michael-cr4gq 7 месяцев назад
I too am trying to learn why my water heater is back drafting. And thus, my question. In my mind a new furnace replacement should not cause the existing pipe to be too big as 6 months of the year the water heater only is using that pipe. Is it a cold pipe that does not draw in the winter?
@Lusandro
@Lusandro 6 месяцев назад
Can the plastic port collars be replaced? Do they leak when they melt?
@buckJuddson
@buckJuddson 5 месяцев назад
I dont recommend 90 degree elbows straight off the top of the hood vent , maybe a 45 but not 90 unless you have some kind of fan sucking the exhaust out . Second i know they say 1 inch of rise for every foot of distance but i recommend way more rise on that 3 inch pipe .
@mts7274
@mts7274 Год назад
So, it's not definitive that the water heater flue setup is causing the backdraft, correct? You mentioned it could actually be a couple of other things related to the furnace setup.
@ScubaCat3
@ScubaCat3 Год назад
I think that's the main issue. it's horizontal for too long
@Margi183
@Margi183 Год назад
What actually IS the problem here, that the backdraft causes? Just trying to learn how things function. BTW thanks for your videos!!!!! 👍
@rigidinspections
@rigidinspections Год назад
The backdraft allows Carbon Monoxide to enter the home
@Margi183
@Margi183 Год назад
Oh GOSH really!!? Oh I'm glad I'm trying to learn!... thanks you are a STAR! (I'd entirely missed yr menttion that the hot water heater was a natural gas appliance. (I'm used to electric hot water heaters.) Was the carbon monoxide alarm going off :o (or did you just notice the water? leak above the 2 melted seals, the seals - which alerted you that there would be a carbon monoxide leak and confirmed what you thought, after you saw the outside 1 ft exhaust, too short, roof exhaust pipe? And esp that the exhaust pipe was now too large to successfully eliminate gases after the furnace was replaced.) So the furnace and previous one are/have been running off natural gas also I yake it right?) Gosh! Seriously well done that you spied 4 things that could lead to a major dangerous potential outcome!
@ricklee827
@ricklee827 8 месяцев назад
I put the responsibility of this on the furnace replacement they should be held accountable for the fact that the flue pipe after the furnace has been changed is now inadequate for the appliances going into the chimney
@dumdiversaspapalbull1452
@dumdiversaspapalbull1452 Год назад
It was working fine until the Hvac unit was changed. Pipe that make up air outside and or change that water heater to an electric one. Cover that return register. Turn the unit off and see if the direction of the air in the hood changes first off.
@Zandermp77
@Zandermp77 29 дней назад
What does backdraft smell like?
@abiku2923
@abiku2923 Год назад
Bump
Далее
Is Your Water Heater Backdrafting?
4:55
Просмотров 25 тыс.
Don't ignore your water heater...
17:15
Просмотров 250 тыс.
Zlatan embarrasses Speed 😂 #ishowspeed
00:32
Просмотров 4,6 млн
What’s Going On with this DECK?
2:34
Просмотров 19 тыс.
Water heater draft testing
7:23
Просмотров 35 тыс.
Water Heater Vent Pipe Inspection Failure and Fix
18:06
How to inspect high-efficiency furnace venting
13:02
Просмотров 40 тыс.
WORST Roof Install EVER on New Home Build
4:58
Просмотров 3,1 тыс.