Тёмный

Baxi Main Hydro Explained. Dr pipe 

Dr Pipe
Подписаться 12 тыс.
Просмотров 21 тыс.
50% 1

This video is about Baxi Main Hydro bloc assembly. An in depth explanation of how the Hydraulic section of one of the Most common boilers on the market for many years. In this I explain the Direction of the central heating flow the pump, Plate heat exchanger for hot water and various other things, together with explanations of many of the faults and how to understand whats what here. Thanks for watching.

Опубликовано:

 

21 мар 2019

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 83   
@cfgman1
@cfgman1 4 года назад
To take this amount of time to share this information especially to the younger inexperienced amongst is really soul uplifting... I don't know how you and Heating Geek have the time to do it... Keep up the good work.
@drpipe
@drpipe 4 года назад
Comment of the month there. Thanks very much. Honestly .. I don’t have the time.. and it’s certainly not for the 💰 I can promise you that. People complain a lot in the industry.. stop complaining and try and help where we can 🤷‍♂️. Trust me I’m not perfect in lots of areas. But I learn stuff everyday. From you guys and others. Thanks for watching 👍👍🙏🙏
@zeidahmed569
@zeidahmed569 Месяц назад
Love the content buddy, thanks a bunch. Keep them videos coming
@drpipe
@drpipe Месяц назад
Thanks 🙏
@smellslikethinice1107
@smellslikethinice1107 3 года назад
Thank you sir, i knew the sequence, but never to the depth you are talking about. A truly heartfelt thanks for your time and knowledge!!!
@drpipe
@drpipe 3 года назад
Appreciated
@willlomas2725
@willlomas2725 6 месяцев назад
I am just starting out and these videos are exceptional thank you.
@drpipe
@drpipe 6 месяцев назад
Welcome
@woodbine66
@woodbine66 5 лет назад
Nice! All brass - just as it should be. WB and Viessmann, please note. Thanks for another quality movie, Dr P.
@drpipe
@drpipe 5 лет назад
woodbine66 appreciate that 👍
@Razz60
@Razz60 5 лет назад
Am so happy i found your channel very well explained thanks
@drpipe
@drpipe 5 лет назад
Much appreciated.
@conand1413
@conand1413 3 года назад
Trying your best. And you are very much successful. Thank you for time, effort and resources for sharing this with us. I, very confidently can say that your videos of the hydraulic system of boilers are the best on the internet. Manufacturers should be very grateful for you as we are.
@drpipe
@drpipe 3 года назад
Much appreciated you took the time to Write that 🙏🙏 Always wished when I Didn’t know how they worked someone would explain in a way I understood. Beauty of doing this stuff is I learn too... I hear you saying but u know it 😂 easy to forget trust me 🙏🙏
@bernardmanners9657
@bernardmanners9657 4 года назад
i'm new to the channel , but these are really clear and informative videos. many thanks and keep up the good work
@drpipe
@drpipe 4 года назад
Bernard Manners pleased thanks 👍👍
@stephenmcgrath2976
@stephenmcgrath2976 2 года назад
Really enjoyed the video had to change my first diverted valve this week wish I had watched couple your videos first love the content only just found the page tonight will keep watching
@drpipe
@drpipe 2 года назад
Pleased you enjoyed
@jbhoyceltic4806
@jbhoyceltic4806 5 лет назад
Your a life saver glad I found you doing my course just now excellent content
@drpipe
@drpipe 5 лет назад
Thanks good luck with the course take a look at the other vids loads on here to help. Thanks for watching 👍
@jbhoyceltic4806
@jbhoyceltic4806 5 лет назад
@@drpipe thank you
@joncoke8208
@joncoke8208 4 года назад
Great video always wondered how the pump proving switch was made
@drpipe
@drpipe 4 года назад
Jon Coke now you know 👍
@raul835
@raul835 2 месяца назад
Brilliant explanation
@drpipe
@drpipe 2 месяца назад
Thank you 🙏 made my day 🙏🙏
@umark6695
@umark6695 5 лет назад
Well explained. Thanks
@ragnarjakobsen7722
@ragnarjakobsen7722 3 года назад
Good work 👍
@dzmalekvali1110
@dzmalekvali1110 3 года назад
THANKS boss, that is helpful indeed.
@trevbunn7407
@trevbunn7407 Год назад
truly excellent explanation!
@drpipe
@drpipe Год назад
Thank you 🙏
@antonybuckley2645
@antonybuckley2645 3 года назад
Great video
@WEYHARRY1
@WEYHARRY1 4 года назад
very good video
@richardbrazier5333
@richardbrazier5333 Год назад
very informative thank you
@drpipe
@drpipe Год назад
Thanks 🙏
@scottwilliams1094
@scottwilliams1094 3 года назад
Great video 👍
@drpipe
@drpipe 3 года назад
scott williams thanks bud.. lot went into that 🙏🙏
@dhani1011
@dhani1011 3 года назад
Great video! Really has helped me. Called out to a breakdown where both pins are rising when there is a hot water demand i have changed the diverter valve. Do you think it could be the filter on the hydro block on the right??
@b1h2u3p4
@b1h2u3p4 Год назад
Nice video
@drpipe
@drpipe Год назад
Pleased your enjoying the content 🙏
@maks1o
@maks1o 4 года назад
Very informative video. I've got Baxi 80E. Replaced diaphragm but hot water is only at high flow rates which is frustrating when doing dishes. What else should I check?
@snigie
@snigie 5 лет назад
It’s not a check valve. It’s a Venturi to give you the push pull motion on the diaphragm
@drpipe
@drpipe 5 лет назад
snigie my mistake I’m dyseleic but I’m sure you understood what I meant by a flow restrictor or whatever I said. That’s for watching.
@snigie
@snigie 5 лет назад
Dr Pipe easy mistake. Great videos by the way. 👍🏻
@drpipe
@drpipe 5 лет назад
I really appreciate what you said many thanks for that.👍
@timeyre9985
@timeyre9985 3 года назад
you are a bute mate!!!!!!!!! good on yer
@ek6868
@ek6868 5 лет назад
👌👍
@manohardevgun6543
@manohardevgun6543 Год назад
thank u for your video, very well explained. I got Baxi duo tec 28 DHW problem. I have changed Diverter, motor is working, Heat exchanger is cleaned, C/heating working, DHW is fine with C/heating But without CH not getting hot water. Can u advise me on this problem. Dev
@drpipe
@drpipe 5 лет назад
Quick Tutorial on a very Common Boiler.. baxi , Main, Potterton combi . Please like and subscribe to Motivate me to produce more Content. Thanks for watching 👍
@sunilchampaneri3208
@sunilchampaneri3208 3 года назад
Genius
@antonybuckley2645
@antonybuckley2645 3 года назад
If the bypass check valve had broken would that stop the pump prooving sw pin rising? What issues would cause a pin tgat didn't fully lift apart from diaphragm
@joneth781
@joneth781 5 лет назад
Can you do a video on the sequence of a boiler and what parts do what? And any tips in general? Thanks
@colin5064
@colin5064 3 года назад
Very helpful video well explained,just like to ask how much water loss to expect when cold water in isolation tap turned off and both gauze filters removed for service cleaning.
@drpipe
@drpipe 3 года назад
Colin 2-3 max litres
@colin5064
@colin5064 3 года назад
@@drpipe Thank you for your most kind help experience and knowledge.Don't wish to be red faced with too small a catch water container
@Anthony-hs8zi
@Anthony-hs8zi 5 лет назад
Thanks again .Any videos of your tools coming up
@drpipe
@drpipe 5 лет назад
Glad you enjoyed it.. won’t be long for the tool bag tour x2 maybe next month. I’m flat out at work and trying my best to put at least 1-2 videos a week ..Thanks for watching.
@TelstarTAK
@TelstarTAK 3 года назад
Thanks for a very informative video. On our Main Combi 30 HE boiler, which looks to have the identical components here, during hot water demand, water is escaping to the heating circuit giving intermittent hot and cold water at the taps. On observing the diverter valve during operation, both the hot water pin and heating pin are pushed out but the heating pin stays out even when there is no heating demand, only hot water demand. Does this mean the components in the diverter valve heating portion are at fault or is it another component inside? The boiler and central heating has been power flushed less than a year ago and all else seems fine. The diaphragm in the front hot water portion of the diverter assembly has been checked and is in good condition. A couple of engineers have visited giving different opinions including change the diverter valve, change the diverter valve and the secondary heat exchanger and of course, change the whole boiler. Another said the plate heat exchanger was blocked. Appreciate any advice.
@drpipe
@drpipe 3 года назад
Turn the iso off what happens 🤷‍♂️
@TelstarTAK
@TelstarTAK 3 года назад
@@drpipe apologies but what do you mean in layman terms? Appreciate your time.
@drpipe
@drpipe 3 года назад
Get a decent Baxi approved Engineer he should work that out in a Second.
@ianpye8690
@ianpye8690 3 года назад
The pin on top of the diverter is for monitoring the pump flow on heating and hot water
@mikewhiskee3498
@mikewhiskee3498 4 года назад
Dr Pipe! Visited a potterton today with this set up, will be going back again...it’s had replaced the div valve diaphragm & the section behind it, the push rod still barely wants to come out to make dhw switch...is this an issue with something at the rear of the valve or the pressure in the 2 thin copper pipes? Any help much appreciated for a vulnerable customer! Cheers
@drpipe
@drpipe 4 года назад
Matt The Gas check pump
@mikewhiskee3498
@mikewhiskee3498 4 года назад
Dr Pipe thanks mate sorted it, I rewatched the video & from your description worked out the venturi on the right hand block had fell to bits. Replaced it & all sorted! Very useful video, have never come across that issue in 15 years!
@timeyre9985
@timeyre9985 3 года назад
did you fix this???? I have same problem, changed all diaphragms, dhw sensor, pcb, still the the push rod barely moves, checked the thin copper tuber not blocked, the only thing have not replace/checked is the dhw filter but water pours out of the connection tubes.
@mikewhiskee3498
@mikewhiskee3498 3 года назад
@@timeyre9985 yes mate it’s the part on the video at 2:20 behind the brass plug on the right hand side. On the one I went to that check valve had disintegrated.
@leonwright9317
@leonwright9317 2 года назад
@@mikewhiskee3498 what did u use to remove the Venturi?
@philpullan8595
@philpullan8595 4 года назад
I believe that design of flow turbine is actually a plunger that rises as the flow it made.
@johnnysingh418
@johnnysingh418 5 лет назад
Excellent videos' new subscriber. any chance you could do one o a vaillaint vuw 242e. Thanks
@drpipe
@drpipe 5 лет назад
Johnny singh Thanks for stopping by.. I strip and video what I take out or what Subscribers Donate to the channel. I haven’t had the 242 for a while so when I do I will be sure to do a Vid on it. Thanks for watching
@michaelw4620
@michaelw4620 2 года назад
Been having an issue with my 105he that I needed to turn two hot taps on for the boiler to recognise the call for heat. 2 local plumbers came out both have said it’s the diaphragm. So got it replaced and the fault stayed. After educating myself I found the plastic cap (you unscrewed) on the non return valve broken off causing equal pressure to the change over diaphragm. Flow circuit non return valve (you said check valve it’s actually a non return valve) was the issue all along! £13.50 and all sorted. Super simple mechanical system. Fucking brain dead plumbers all just want a digital screen telling them an error code.
@drpipe
@drpipe 2 года назад
You watched then fixed the fault 👍💪
@michaelw4620
@michaelw4620 2 года назад
@@drpipe unfortunately not quite that easy but I would recommend plumbers start going back to basics and learn their craft.
@maxxsalimu4019
@maxxsalimu4019 8 месяцев назад
I changed diverter valve but wen I run hot water, left pipe heat up heating flow heats up
@none-qq9lg
@none-qq9lg Месяц назад
Main 24 HE filling loop is closed, but pressure gauge is over 2.5 to 3 bar upon which the PRV is releasing water outside. Would the culprit be the plate heat exchanger?
@drpipe
@drpipe Месяц назад
Not necessarily
@none-qq9lg
@none-qq9lg 28 дней назад
​@@drpipe what else could it be? When the heating is on the pressure increases and releases water outside
@nikquatty
@nikquatty 3 года назад
Can the CH water ever mix with the drinking water through the heat exchanger or anywhere else. On the boiler?
@drpipe
@drpipe 3 года назад
Split yes
@nikquatty
@nikquatty 3 года назад
@@drpipe A split inside the Exhanger ? Tell tale signs be discolouration of drinking water?
@valvemonky4734
@valvemonky4734 5 лет назад
HI i have a Potterton combi that has a problem with intermittent hot water. some times it will work ok but will take some time to get hot other times it will not give me hot water then after some time will start to give hot water then it will go cold again then it will go hot and it will run OK but some times it will get very hot . some times it will run cold and not give hot water at all till you turn the hot tap off and then on again . what could be the problem ? the only time i checked the divert valve it had operated the micro switch and the hot water was working. it would be great if some one could give me some advice on what could be the problem ?as it is a bit frustrating
@drpipe
@drpipe 5 лет назад
valve monky The list is Endless without seeing the job. Could even be a Shower valve thermostat causing the issue !
@valvemonky4734
@valvemonky4734 5 лет назад
@@drpipe thanks for the reply was a bit of a cheeky question i don't have a thermostat shower control valve but thanks again
Далее
Baxi Diverter How to service, Start to finish Dr Pipe.
20:34
Clowns abuse children#Short #Officer Rabbit #angel
00:51
Would you help?!😳
00:32
Просмотров 6 млн
Vaillant Ecotec Hydro Assembly Explained. Dr pipe
10:34
Baxi 105e hydro block
6:21
Просмотров 537
Clowns abuse children#Short #Officer Rabbit #angel
00:51