Boiler Blowing Black Smoke From Chimney! 

Jeff’s HVAC Adventures
Подписаться 5 тыс.
Просмотров 8 тыс.
50% 1

In this video I clean and service a very dirty, completely packed with soot, Peerless Oil Boiler.
Later, I replace the main board on a Brand New Bosch Heat Pump!
Like and Subscribe!
Support the Channel!
PayPal: ​⁠@JeffsHVACAdventures
CashApp: $JeffsHVACAdventures
Venmo: @JeffsHVACAdventures
Get you a Inficon D-Tek Stratus! Use the link below
amzn.to/45O78on
Check out the whole Inficon product line here!
amzn.to/3sD6wne
Use the link below to get 10% off on the TOPTES PT520B Professional Combustible Gas Leak Detector! Use promo code R98D8JH8
amzn.to/43Wti6D
Also check out the TopDon TCView Thermal Imaging Camera for Android or iPhone. Use the links below for a sweet discount!
Thermal Camera TC001 for Android amzn.to/45e9rAO
Thermal Camera TC002 for iPhone amzn.to/3OesV1s
Questions, comments or to just say Hi, email me
jeffshvacadventures@gmail.com

Опубликовано:

 

29 авг 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 18   
@susanschultz2752
@susanschultz2752 5 месяцев назад
How come techs do not clean the inside of peerless burners anymore. Last time I saw an older guy clean our old peerless was 15 years ago. I'm watching videos now to learn how to do it myself. We just had ours serviced, and the guy didn't do it.
@user-sx2xy8dn9v
@user-sx2xy8dn9v 11 месяцев назад
Another great video Jeff! 👏👍☝️💥
@JeffsHVACAdventures
@JeffsHVACAdventures 11 месяцев назад
Thanks!
@BlueDinnie
@BlueDinnie 11 месяцев назад
Holy barbecue Batman
@Bob.W.
@Bob.W. 11 месяцев назад
Like a Steve Lav video. Get out the old soot saw. :). Thanks.
@briancarlisi2224
@briancarlisi2224 11 месяцев назад
Great video. Can you do a before and after combustion analysis on your next boiler cleaning? It would be interesting to see the improvement in performance. Thanks!
@JeffsHVACAdventures
@JeffsHVACAdventures 11 месяцев назад
When they are this sooted up, you can’t do a before reading, it would damage the sensors in the analyzer.
@phoenixlee7949
@phoenixlee7949 5 месяцев назад
Have you ever dropped your brush down one of those openings?
@JeffsHVACAdventures
@JeffsHVACAdventures 5 месяцев назад
I’ve broke one off in there before. Had a hell of a time getting it back out. Almost said F it. But I ended up getting it from the firebox side.
@Ruben-sg4xu
@Ruben-sg4xu 11 месяцев назад
Hey Jeff can low refrigerant cause a compressor to go into thermal overload? Or in short, cutout ot start?
@JeffsHVACAdventures
@JeffsHVACAdventures 11 месяцев назад
Yes it can. Hopefully the system would have a low pressure cutout switch installed to protect the compressor but some don’t. And yes the lack of refrigerant return to the compressor could cause a overheat/overload situation. An overload condition is more likely to happen due to a faulty capacitor, worn electrical windings or a dirty condenser, but it’s not unheard of to happen in a low refrigerant condition.
@Ruben-sg4xu
@Ruben-sg4xu 11 месяцев назад
@@JeffsHVACAdventures Thanks for the info. I think I'm experiencing exactly that right now in my system. Hard to pinpoint though.
@jmc1771
@jmc1771 11 месяцев назад
What caused the soot? Usually soot production comes with dangerously high carbon monoxide
@JeffsHVACAdventures
@JeffsHVACAdventures 11 месяцев назад
Usually, until you clean it. I didn’t even do a before CO ready because it would have tore up my sensor.
@dock_yard1149
@dock_yard1149 11 месяцев назад
Wrong or malfunctioning nozzle in oil burner. Wrong air inlet setting on oil burner. (Bad draft over fire)
@ChingusTheOneAndOnly
@ChingusTheOneAndOnly 11 месяцев назад
Mostly over looked is insufficient make up air in boiler room and air bands , burner blower wheel plugged up with dust or pet hair
@CDX825
@CDX825 11 месяцев назад
Too much excess air at 9.4 CO2.
@franks6837
@franks6837 11 месяцев назад
Where a mask when doing carbon cleanings please. I knew a guy who did them for a living and he basically died of black lung I'm not taking 50 years ago either
Далее
Goodman A/C NOT COOLING!  More Than Just The Obvious!
14:47
HVAC Companies HATE That You Can Do This Yourself.
25:51
BADLY SOOTED WALLSTAR OIL BOILER ALL SORTED
16:41
Просмотров 10 тыс.
How to Clean a Boiler Heat Exchanger - Video #9
13:27
This Heat Pump changes EVERYTHING | R290 Heat Pump
7:33
Easy Riello Burner Repair
10:03
Просмотров 119 тыс.
OIL FURNACE ANNUAL SERVICE
14:19
Просмотров 15 тыс.