Тёмный

Connections in 3 Switch Fuse Connection Units (Switch Fuse Spurs) Layout of the Terminals Explained 

GSH Electrical
Подписаться 145 тыс.
Просмотров 83 тыс.
50% 1

In this video I look at the connections in 3 different switch fuse spurs (switch fuse connection unit). The layout of the terminals and how the labels differ between brands for the terminals. This video has been produced to help my learners in the electrical workshop at Tresham College.
🔔 Subscribe for more free electrical training videos ru-vid.com?s...
== 🕐 Time Stamps - Cut to the action 🕕 ==
00:00 - Connection in a fuse spur
00:29 - 3 different types
00:43 - BS1362 fuses
01:12 - Feeding hand dryers etc
01:42 - Connection unit 1
03:27 - Connection unit 2
05:16 - Connection unit 3
Videos are training aids for City and Guilds (C and G) and EAL courses Level 1, 2, 3 plus AM2, AM2S and AM2E.
You can follow me day by day on Facebook, Instagram, Twitter and TikTok lookout for "GSH Electrical”.
▶️ FACEBOOK / gshelectrical
▶️ INSTAGRAM / brihzmraygdtmjmdb9lunq...
▶️ TWITTER / gsh_electrical
▶️ TikTok vm.tiktok.com/ZMRBLFdhe/
#GSHElectrical #Electricaltrainingvideos

Опубликовано:

 

8 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 65   
@manuelabayomi3276
@manuelabayomi3276 7 месяцев назад
Your explanation for the third one was what I was looking for. Thanks
@julianfisher6373
@julianfisher6373 Год назад
Again all fully explained & crystal clear !! Many thanks & keep your videos coming.
@GSHElectrical
@GSHElectrical Год назад
Thanks for the support 👍🏻 Gaz
@kierandoherty1420
@kierandoherty1420 2 года назад
Great stuff cleared up my confusion on supply & load 👍
@rabk5702
@rabk5702 20 дней назад
The second had me confused as it was the same as the one, I have and I was not too sure about it as I not seen this type before, but your video help me thank you 😁😁
@GSHElectrical
@GSHElectrical 20 дней назад
Thanks for the feedback
@PickleJim
@PickleJim 5 лет назад
Thanks Gary, clear concise and informative as ever.
@GSHElectrical
@GSHElectrical 5 лет назад
Thanks 👍
@Mark_Thompson_Author
@Mark_Thompson_Author 2 года назад
Brilliantly explained!Thanks.
@tonydemetrios1251
@tonydemetrios1251 5 лет назад
So glad I stumbled across your you tube channel. I’m a complete novice doing my part p 18 edition wiring course mid September. And find your videos so informative. Keep them coming 🤣🤝
@GSHElectrical
@GSHElectrical 5 лет назад
Hi, thanks for the wonderful comment and good luck in your studies. Gaz 👍
@efixx
@efixx 5 лет назад
Have you checked-out Gaz and Joe’s website Efixx.co.uk and the RU-vid channel Efixx 👍. Thanks 👍
@davidroche6973
@davidroche6973 5 лет назад
Helpful video as always 👍
@tobycoombs2446
@tobycoombs2446 5 лет назад
Another great video for your learners 👍🏻
@GSHElectrical
@GSHElectrical 5 лет назад
Many thanks for the positive feedback and comment. GAZ
@errickmagar3928
@errickmagar3928 4 года назад
Really helped! Thank you GHS
@GSHElectrical
@GSHElectrical 4 года назад
ERRICK MAGAR thanks for watching 👍
@adnanidf94
@adnanidf94 3 года назад
Great video. Very clear to understand.
@GSHElectrical
@GSHElectrical 3 года назад
Thanks 👍
@richardwash6678
@richardwash6678 4 года назад
Another useful video Gaz 👍
@GSHElectrical
@GSHElectrical 4 года назад
Thanks Richard 👍
@brightspark263
@brightspark263 5 лет назад
Great video as usual Gaz. I wish manufacturers standardised the locations of the terminals so they are in the positions of the first FCU you showed. I've used FCUs with the terminals laid out in the second example and it's really fiddly to get the wires in neatly because they are spread across the back of the FCU, whereas with the first example you can bend the cables easier to fit into the backbox.
@rickprobert5189
@rickprobert5189 2 года назад
Fab video, thanks!
@GSHElectrical
@GSHElectrical 2 года назад
Thanks Rick 👍🏻
@user-bz3wn1zo7e
@user-bz3wn1zo7e 2 месяца назад
Great, thanks!
@GSHElectrical
@GSHElectrical 2 месяца назад
Thanks
@michaelcostello6991
@michaelcostello6991 10 месяцев назад
Great detail. Thanks
@GSHElectrical
@GSHElectrical 10 месяцев назад
👍🏻
@fostexfan160
@fostexfan160 3 месяца назад
can you connect another 2.5mm wire into the supply terminals to continue the supply or is it better to use a junction box?
@jeanclaude2794
@jeanclaude2794 4 года назад
hello from toronto canada cheers!!!
@GSHElectrical
@GSHElectrical 4 года назад
👍😊
@imonw3b
@imonw3b Месяц назад
Hi can I add fcu from fcu as the other spur socket is going out to the garden. Thanks
@earlofgriefem
@earlofgriefem 5 месяцев назад
I'm doing a job where I need to re-box in some boiler pipes. The old boxing had one of these switches and I plan to replace. So I understand the load is the kitchen extracor fan but I have 2 other cables feeding in, one is from a plug socket and one presumably is connected ti the consumer unit, I was wondering should both of these cables classed as supply (in) ?
@davidb3537
@davidb3537 3 года назад
Great factual video clearly pointing out the inconsistencies relating to terminations within accessories. While my personal preference is for the MK unit, I do find the flex cable grip difficult to use on any cable with conductors over 1mn csa. Considering how long accessories have been in production it is surprising the lack of uniformity from manufacturers.
@GSHElectrical
@GSHElectrical 3 года назад
Thanks for commenting and the feedback. Gaz 🦾
@spencera.8453
@spencera.8453 8 месяцев назад
Got a video for wiring a 3 Pole Fan Isolator Switch c/w 3 Amp Fuse?
@rickgreaves67
@rickgreaves67 10 месяцев назад
Great video. Can I spur of a main ring socket with a fused spur, to almost make like a radial circuit to carry on going outside. Or do I need to cut into the main ring with the fused spur. Thanks.
@yaqubkhan8092
@yaqubkhan8092 11 месяцев назад
Great video for guidance
@mixer7586
@mixer7586 3 года назад
Is the fused spur switch double pole? If so does the fuse just break the line conductor.?
@dilligaf2386
@dilligaf2386 2 года назад
Superb explanation
@GSHElectrical
@GSHElectrical 2 года назад
Thanks 👍🏻
@SinsofMathetes
@SinsofMathetes 2 месяца назад
So I have the first switch fused, all electrics works as should but when I switch off at fuse electrics still work, even when I take fuse out!
@michaelcostello6991
@michaelcostello6991 8 месяцев назад
Is there a video on where there may be dangerous high voltages present in a factory etc etc eg at transformers . Places we need to keep well away from.
@zedman442
@zedman442 5 лет назад
Great Job. One takeaway... Choose MK 😉
@GSHElectrical
@GSHElectrical 5 лет назад
😉👍
@Marcel_Germann
@Marcel_Germann 5 лет назад
For the protective earth I would always use the the terminal most far away from the flex entry. Then the PE conductor is always longer than the L and N of the flex. If someone rips out the flex cable and the strain relief is failing, the protective earth connection will fail as the last connection. I always make the PE ~20mm longer than L and N. Sometimes this is ensured by the construction, for example of a plug. The BS1363 for example, the PE conductor is the longest wire, and through this it will fail at last.
@mrj4264
@mrj4264 Год назад
Load would also be used for an inline fan?
@hermanliu8637
@hermanliu8637 2 года назад
Very good RU-vid learning. Please advise if i) a switched fuse spur for a boiler should be 3 amp or 13 amp ? ii) if the former, would it be ok if the fuse spur's 13 amp be just replaced by a 3 amp fuse ? iii) how come my switche fuse spur just has one hole for Earth ? Many thanks.
@user-yv9ui6co6r
@user-yv9ui6co6r 2 года назад
Hello what will happend if I use this fuse in 12 volt system , the fuse will let the current enter to the load ( 12v load ) ? Or the 12 volt current won’t be able to enter to load ?
@papillonbougie7080
@papillonbougie7080 Год назад
when you test continuity between live in supply part and live in load part there is no continuity so how current flows to the load
@Ianw236
@Ianw236 2 года назад
Are there any smart switches available that can replace these fused switches ?
@ibrootsc2867
@ibrootsc2867 4 года назад
Can you please do a video on wiring p.i.r. Motion sensor to existing lights?
@dg2908
@dg2908 5 лет назад
Good educational video. Kept it factual too rather than telling us that the second example was a rubbish design. Would it be more accurate though to state that the fuse must be selected to protect the outgoing cable rather than the connected load? I know practically speaking that you'd want to coordinate all three.
@whatliesbeneathurbanexplor1631
@whatliesbeneathurbanexplor1631 2 года назад
GSH ELECTRICAL hi see the way if you have two double sockets coming from a 13 fused switched spur from a 20amp trip switch. Can you add two 3amp fused spurs for lightning at the second double socket Thanks
@GSHElectrical
@GSHElectrical 2 года назад
Wiring a Light From a Socket Outlet and Safe Isolation of a Switched Fuse Connection Unit (Spur) ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-E6AxYPlnl_s.html
@LocoSajoca
@LocoSajoca 3 года назад
Hi Gary, can I ask.. Could you wire straight into an fcu a 6mm twin and cpc cable and bypass a socket that is spurred from it? For instance a cooker cable. Just wondering if this would be possible with a 13A fcu
@JD_London
@JD_London 3 года назад
Why would you bypass the socket bud?
@LocoSajoca
@LocoSajoca 3 года назад
@@JD_London for example, my cooker is flat twin and earth 6mm cable that wires into a cooker outlet which is spurred from a cooker switch (traditional red switch type) so it isn't doesn't have a plug because it is not a flex. The reason i ask is if someone moved and kept their cooker but the new place has a socket outlet spurred from an fcu spurred from a cooker switch, could you just wire into the fcu or would you have to replace the cable?
@shaunbeard593
@shaunbeard593 5 лет назад
Hi Gaz could this be used to step down from a ring main to run a light in my she'd. With the appropriate wire and fuse. Many thanx
@GSHElectrical
@GSHElectrical 5 лет назад
Hi Shaun, you would have many other considerations before carrying out the process you have stated. Thanks as always for your comment and all the best. Gaz 👍
@shaundavies2169
@shaundavies2169 4 года назад
Great video very informative, a question I got from a relative who had to replace a fused swit h but because the manafactuarar must of been different so he couldnt copy the wiring he is unsure is he fitted properly as in putting the supply to supply and load to load he got the correct wires in as earth neutral and live but if he mixed the supply and load around would it still work? and isit dangerous? Thanks again buddy
@GSHElectrical
@GSHElectrical 4 года назад
Shaun Davies hi it will still work
@shaundavies2169
@shaundavies2169 4 года назад
@@GSHElectrical thanks for the quick reply! Still all safe then?
@papillonbougie7080
@papillonbougie7080 Год назад
I do apology yes there is contiguity, my socket switch was off that is why there was no continuity
@richardcook1987
@richardcook1987 2 года назад
no not clear.
Далее
SPURS ON SPURS Extending Circuits
19:23
Просмотров 55 тыс.
What turned out better to repeat? #tiktok
00:16
Просмотров 3,4 млн
100❤️
00:19
Просмотров 4 млн
How to Wire a 13 Amp FCU - Fused Connection Unit
8:59
Просмотров 1,8 тыс.
5 Mistakes Everyone Makes Changing Sockets ❌
11:44
Просмотров 480 тыс.
How to Extend Short Wires | Easy Fix Anyone Can Do
6:52
Spurs on Sockets in Electrical Installations
4:45
Просмотров 11 тыс.
What turned out better to repeat? #tiktok
00:16
Просмотров 3,4 млн