This is a 13.5 KW diesel generator powered by a Lister-Petter LW3 three cylinder diesel engine. It ran fine a month ago, but three weeks ago we had a lighting strike that took out a lot of electronics and shut down our grid power. I tried to start the generator, which was NOT connected thru the transfer switch to the grid, and it would start and after a few seconds shut down, the start again, and shut down. Watch the fuel cutoff solenoid. Any help in trouble shooting would be appreciated. For some reason the sound does not match the actual running and shut down at the halfway part).

Опубликовано:

 

22 июн 2018

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 14   
@johntellerman
@johntellerman 9 месяцев назад
It was the AVR-Automatic Voltage Regulator. A small circuit board available on Amazon for about $30. It has to be adjusted on its small rheostat for voltage once installed.
@KevinSaari-tg2wy
@KevinSaari-tg2wy 7 месяцев назад
Can you provide the part number for the voltage regulator. I am having the same issue. Thanks
@earlathill3944
@earlathill3944 9 месяцев назад
Check the exciter coil.. when they burn they shut off.
@JohnSmith-lw2bm
@JohnSmith-lw2bm 4 года назад
For some reason the engine is being told to shutdown then, low oil pressure maybe????
@dnsfarmer
@dnsfarmer 4 года назад
Any Updates?
@user-zh4gg1zt6s
@user-zh4gg1zt6s 6 месяцев назад
I nèed help i have also seen these problems what is the reason behind?
@johntellerman1
@johntellerman1 6 месяцев назад
It was the small circuit board inside the lower black box. It was the AVR, or Automatic Voltage Regulator. It had a blown bit on the circuit board. We replaced the board ($28 on Amazon) and adjusted the voltage on it and it ran fine. It was due to a lightning strike nearby they traveled up the ground wire.
@mallireddypalli3150
@mallireddypalli3150 3 года назад
Remove engine oil If you put plenty like this stop automatic
@earlathill3944
@earlathill3944 3 года назад
Did you get it resolved? I have an LPW4 that’s doing the very same thing and I’m lost as to what else to do.
@johntellerman1
@johntellerman1 3 года назад
Turned out to be a small circuit board inside the generator itself on the side under a panel. It's the AVR or Automatic Voltage Regulator. It has to sense the generator producing voltage or it shuts the engine down.
@frazerlembalemba3551
@frazerlembalemba3551 9 месяцев назад
​@@johntellerman1I have also a dse mkii7320 is doing the same without displaying any warning sgn
@frazerlembalemba3551
@frazerlembalemba3551 9 месяцев назад
Please anyone who has an idea
@rorythompson5570
@rorythompson5570 5 лет назад
Did you get it fixed?
@johntellerman1
@johntellerman1 3 года назад
Yes. it was the AVR circuit board. Found one on Amazon for $29 so I bought two! It failed due to nearby lightning strike. It wasn't even on the grid but took the it thru the ground cable.
Далее
How To Fix A Generator That Won't Stay Running
4:01
Просмотров 331 тыс.
Diesel Generator - Bleeding Air From Fuel Lines
4:21
Просмотров 393 тыс.
Fuel System Bleeding
4:39
Просмотров 463 тыс.
Generator Runs A Few Minutes & Dies - Here's Why!
5:08
Generator Starting problems and troubleshoot
7:44
Просмотров 36 тыс.