With over 12,000 votes on a community poll, 2 out of 3 people voting were incorrect when asked if a GFCI outlet needs a ground to provide ground fault protection. In this video, I will walk you through the reason a GFCI outlet still provides ground fault protection with or without a ground wire. I will also outline why I have used this installation in the past to make my properties safer.
Wago 221 Lever Nuts
Starter Kit: amzn.to/3LuMRdE
My Favorite Kit: amzn.to/3DmNPWl
Assortment Pack: amzn.to/3JVAlDn
3 Wire Connector (50 pack): amzn.to/36DM62Z
2 Wire Connector (100 pack): amzn.to/36Yx2wO
Free Home Maintenance Checklist
everydayhomerepairs.com/home-...
DISCLAIMER: This video and description contain affiliate links, which means that if you click on one of the product links, I’ll receive a small commission.

Хобби

Опубликовано:

 

5 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 847   
@baire702
@baire702 2 года назад
You are awesome and so is your information! I have ADHD and find it difficult to understand a lot of people's descriptions on how to do things, but you make your information clear, even for me! Thank you!
@protoman247
@protoman247 2 года назад
Nice detail at 4:25. I was wondering why my tester wouldn’t trip the gfci. I figured it was cuz there was no ground. Makes sense. 👍
@ericyoung772
@ericyoung772 2 года назад
20 years ago I was buying an older triplex with 2 wire outlets and the home inspector mentioned putting in a GFI to protect people and eliminate those adaptors. I am glad he shared the information just as you are. Thanks.
@mweezy
@mweezy 2 года назад
I had a conversation with a school instructor and he said, every device box must have its own GFCI receptacle based on the Canadian Electrical Code book. Now that can get pretty expensive and I don't know if people are doing that.
@im2yys4u81
@im2yys4u81 Год назад
@@mweezy Here in the US you can put the GFCI on the first receptacle in the circuit and it will protect the other receptacles downstream.
@hinspect
@hinspect Год назад
@@im2yys4u81 Ground fault Breakers are available too
@im2yys4u81
@im2yys4u81 Год назад
@@hinspect When I did my panel swap a few weeks ago I went with dual function breakers, then had to go through the house and remove the GFCI receptacles.
@fromagefrizzbizz9377
@fromagefrizzbizz9377 11 месяцев назад
@@mweezy I think you misunderstood that. The rule is that every outlet must have GFCI protection, but not the actual GFCI device. You can either chain them with a GFCI first from the panel, or use a GFCI breaker. In fact, the rules are becoming stricter, and virtually all general purpose outlets must be AFCI/GFCI. The AFCI part can only be done in the panel.
@Tom-In-Ga
@Tom-In-Ga 2 года назад
Perfect explanation even though there are always those that will argue the point 'till hell freezes over. Remember, the question was if you "NEED" ground for gfci to work. The answer is no. If the question was if it was preferred, then yes.
@fromagefrizzbizz9377
@fromagefrizzbizz9377 2 года назад
In fact, you NEED GFCI to work on groundless circuits in order to bring two-wire circuits up to code when you make a modification to it. [When you modify an existing circuit, the code requires you bring that circuit up to current code. The code's being nice to you by allowing GFCIs as a legal alternative to tearing up walls to install 3 wire.]
@Tom-In-Ga
@Tom-In-Ga 2 года назад
@@fromagefrizzbizz9377 Agreed. I'm just amazed at how so many people answered "no" to the simple question of whether it will work or not without ground.
@stevelopez372
@stevelopez372 2 года назад
@@Tom-In-Ga Yes I am amazed as well. I remember when it first hit the NEC about 1972. I was in High School and worked construction during the summer in SoCal. And even after my 35 years as a Building Inspector, there is still confusion about this device. ARC- Fault as well. Lol.
@MarkEmerAndersonII
@MarkEmerAndersonII 2 года назад
@@Tom-In-Ga Yeah - the beauty of GFCI is how it measures the small differences in hot and neutral currents to trip. If the ground wire had to be involved it would be hard to detect it fast enough and still provide safety.
@fromagefrizzbizz9377
@fromagefrizzbizz9377 2 года назад
@@Tom-In-Ga It demonstrates I think wilful ignorance of a LOT of code/diy publications saying EXACTLY what GFCIs are intended for, and why they do work. On the other hand, such polls are pretty meaningless. Do they mean ground wire, or alternate grounding path. From the perspective of personal safety, it doesn't matter if there is one or not. If there is one, it trips, and saves you. If there isn't one, no current flows, no electrocution, and it can't hurt you even tho the GFCI doesn't trip. Then you get the pedants saying they don't work without a ground path - technically true. But misleading in terms of above. Then you get into how qualified are the respondents? If the guy answering doesn't do any wiring, what difference does it make? The only bad part is those making recommendations in videos or on comments, that say that GFCIs don't work without a ground wire. That's just plain wrong, and is in contradiction to code, official code-guides and everything else.
@billmongiello4885
@billmongiello4885 7 месяцев назад
many guys are talking about this application on youtube but your explanation is the most complete that i have seen...it explaines every aspect of replacing a 2-prong receptacle outlet with a gfci...thanks
@OhDannyBoy2k
@OhDannyBoy2k 2 года назад
Fantastic video. I've never seen this called out so clearly.
@millomweb
@millomweb 2 года назад
But wrong !
@sherrykendrick1765
@sherrykendrick1765 2 года назад
@@millomweb how so?
@wellsnapyeah
@wellsnapyeah 2 года назад
@@millomweb how so?
@millomweb
@millomweb 2 года назад
@@wellsnapyeah They work on detecting an alternative current path than the pair of power wires that are supposed to be the only wires carrying current. The only way there's going to be an alternative current path is when that alternative path is complete. So if that path involves the use of 'ground', 'ground' has to be connected in to the circuit AT THE OTHER END - which usually means to the neutral wire - and that wire is connected back to the GFCI - so even without an identified earth/ground wire to the GFCI, there is actually still a ground connection. to it. WITHOUT that connection, an alternative circuit would not exist to cause an imbalance in the 2 wires supposedly providing the power. Having bought a generator about a year ago, I've spent SOME time getting my head around how all this works. If there's not alternative current path, the GFCI cannot trip (and is not actually needed ! BUT IF a circuit should happen it would work and would be a useful safety device.
@-agent-47-80
@-agent-47-80 2 года назад
Thank you for explaining WHY to those who didn't know this situation......I work on older homes where adding a ground is financially impossible..... otherwise adding a ground to every outlet is advisable
@trek520rider2
@trek520rider2 2 года назад
To make life more bearable you only need one GFCI outlet per circuit on the outlet nearest the circuit breaker. Finding the outlet nearest the breaker can be a challenge!
@theward1244
@theward1244 Год назад
How does one find out which outlet is the first one in the line?
@-agent-47-80
@-agent-47-80 Год назад
@@theward1244 shut off power to the circuit remove hot(black) wires to outlets...turn on power and check which one has power.... that's your first one in line
@shanecompton2428
@shanecompton2428 Год назад
@@trek520rider2 true but tell that to Section 8 people. I ended up switching all 2 prong plugs to gfci
@SiPuedesTambien
@SiPuedesTambien Год назад
@@shanecompton2428 you could also use a GFCI and to make it even better, a AFCI/GFCI breaker type. In this case the receptacles in that circuit are protected.
@MrTrashcan1
@MrTrashcan1 Год назад
Without a ground wire, I couldn't figure out why the GFCI worked. This was the best description I've heard and completely clarifies it. Thank you very much!
@2manycatsforadime
@2manycatsforadime Год назад
Doing this project today and ran into every confusion mentioned. Wow everything explained clearly. Thank you.
@ryn022
@ryn022 Год назад
4:26 - saved me! Swapping out old outlets and then using my old plug-in GFCI tester and nothing was tripping. Thought I'd weird everything incorrectly. Thank you for explaining. Great video.
@poncho6784
@poncho6784 Год назад
This totally changes my plan for my class B camper van build. I wasn’t going to include a GFCI on the 120v system because I had read they wouldn’t add any protection without a true earth ground. The exception being of course if you’re connected to shore power where the supply is supposed to be grounded to earth. So much for experienced electrical “experts” on the ‘net. Thanks for the helpful vid!
@EverydayHomeRepairs
@EverydayHomeRepairs Год назад
You bet! Best of luck on the project, sounds fun 👍
@cjtzioumis686
@cjtzioumis686 2 года назад
That was beautifully explained. You also put my mind to rest, as my daughter's apartment has those labels on some of the outlets and we were unsure what sort of protection they actually provided.
@andrewtoth9876
@andrewtoth9876 4 месяца назад
Thank you. With your instructions, I just completed the installation of multi GFCIs. My Family is safer now given your gracious assistance. Bless you!
@ReclusiveMountainMan
@ReclusiveMountainMan Год назад
I just re-did all the two prong outlets in our place, which was built in the early 1950s. Was wondering why the Klein tool did not trip the non-rounded GFCI outlet. Great that there will be some protection from the GFCI outlet by itself. Thanks for the education.
@dandearman2871
@dandearman2871 11 месяцев назад
With a non-grounded outlet there is no path to ground to make any fault current for the GFCI to see. If you want to test your GFCI outlets plug your Klein tester into a cheater plug and then into your GFCI outlet. Find an electrical ground and run a wire from it to the grounding tab on your cheater plug and now the test button should trip the GFCI.
@fromagefrizzbizz9377
@fromagefrizzbizz9377 8 месяцев назад
@@dandearman2871 This is unnecessary. A gfci does not need a ground, the test is by drawing a small current with some of it bypassing the detection coil. If a gfci tester (or test buttons) fails to trip a gfci the gfci is either defective or it’s being supplied thru the load terminals, not the line ones.
@ragmanintx
@ragmanintx 2 года назад
These things are great for old homes without a ground wire. Love the option.
@sminthian
@sminthian 2 года назад
These cost like $20 vs a normal $1 outlet. You might as well just do it correctly and run some 3-wire Romex out to it....
@TylerTron21
@TylerTron21 2 года назад
@@sminthian without pulling permits or without an electrician? Because it cost a ton of money to run Romex everywhere, to code. Especially through solid walled homes.
@hammerridecycling7630
@hammerridecycling7630 2 года назад
just bought a house 1960 and no ground wires.gfci not grounded so this helps understand now.and i still have that zinsco panel😪
@TylerTron21
@TylerTron21 2 года назад
@@hammerridecycling7630 I had a zinsco as well and just had it replaced by my electrician friend for 1200$. New panel with new circuits. Definitely recommended, mine was faulty and the main breaker didn't even cut power.
@vlad1889
@vlad1889 2 года назад
@@sminthian Where I live everything needs to be piped pretty much. So good luck.
@herbiesnerd
@herbiesnerd 2 года назад
By code, GFCI’s must trip between 4-6 mA’s. A Hubbell rheostat type tester is a great tool to properly test a GFCI. It ranges from 1-7 mA, 1 mA at a time so when it pops, you know exactly what mA set it off. Anything less than 4 mA that trips it is considered a nuisance. Anything over 6 mA is not enough protection. Toss the GFCI for a new one if it’s outside the 4-6 mA range.
@alistair1978utube
@alistair1978utube 2 года назад
By code, apostrophes aren't used to form plurals.
@jcwoods2311
@jcwoods2311 2 года назад
@@alistair1978utube They're just being possessive..................(On my period, don't judge me!)
@ronb6182
@ronb6182 2 года назад
@@alistair1978utube who the blank cares. The point is made . Go and teach all the Hispanics to speak English you would be better off. There are hundred's of reason's why!. 73
@sherrykendrick1765
@sherrykendrick1765 2 года назад
@@alistair1978utube who cares. We get the meaning.
@alistair1978utube
@alistair1978utube 2 года назад
@@sherrykendrick1765 people with an IQ over 90 usually care about getting things right...
@NativelyBornAmerican
@NativelyBornAmerican 2 года назад
Thanks for your excellent explanation! I knew all this but your explanation is much clearer than mine when trying to explain it to others.
@jolyonwelsh9834
@jolyonwelsh9834 2 года назад
They also make DFCI receptacles (dual function) which provide ground fault and arc fault protection as well. They are the same size and shape as a standard GFCI receptacle and can also be used for the same application.
@richardberryhill718
@richardberryhill718 2 года назад
Very informative video! Been a lab tech do-it-yourself for years and never knew about GFCI and grounding! Super to learn!
@markricci1361
@markricci1361 7 месяцев назад
That's a terrific explanation and the way you were so deliberate in your delivery made it clear how important the topic is and to take the time to fully understand it.
@danjoe22
@danjoe22 2 года назад
something I already knew but great explanation of the safety feature a gfci can provide when there is no equipment ground.
@tek4
@tek4 2 года назад
GFI or GFCI are a wonderful device. They measure the current that travels out on the hot lead, and what returns on the white Neutral wire. If there is any difference it will shut off, and potentially protect you. Normally it will trip at 10 miliamps and has saved many many people. If you took the Hot and Neutral and pretended they were on a sea saw, if they get out of balance, the circuit will open with a GFI. Its one of my favorite upgrades as a electrician to bring a house up to code with minimal investment for the customer. Ideally I would do a whole house rewire, because that would make me more money, however, this option is not really great most of the time because of the amount of labor it is to run new circuits threw the home. Arc Faults are finally getting better then when they were introduced are a different animal that works by listening to the wire and tripping of there is any arc. Different job, reason and purpose.
@eapbg
@eapbg 2 года назад
Small correction. A GFCI does not measure the current. It uses "one simple trick". When both hot and neutral wires pass thrugh the same current ransformer their magnetic fields cancel. The current transformer does not register any current. Only when there is an imbalance does the current transformer register a current. So effectivly the GFCI measures the imbalance of current, not the current itself.
@johnd5398
@johnd5398 Год назад
good thing you were here to parrot what the fucking video just said...
@rogerk1710
@rogerk1710 2 года назад
Thanks for the info on a very informative video. I’m a licensed GC and I installed GFI’s on an old apartment. I labeled the load outlets with the No equipment label but I didn’t put the GFCI protected labels. I will do so in the future! Thanks
@rhoonah5849
@rhoonah5849 Год назад
Excellent explanation. I had always wondered "why" a GFCI was still advised with an ungrounded outlet.
@Wirenutby
@Wirenutby 4 месяца назад
I was going to make a video explaining this exactly as you stated for my friend. You nailed it. Your video was very detailed and easy to understand you. Great job!
@hdcrow
@hdcrow 2 года назад
You always explain things so clearly. Thank you.
@millomweb
@millomweb 2 года назад
But wrong ! The GFCI needs a ground - and if it doesn't look like it has one, it'll use the neutral wire as that will be connected to ground usually somewhere.
@nicwelch
@nicwelch 2 года назад
@@millomweb Can you provide a source or a statute? I don’t see how what he said is wrong. It doesn’t need a ground to work. Edit. In fact I just double checked and you don’t seem to know what you’re talking about.
@josemunoz2464
@josemunoz2464 2 года назад
Great video! I have an outdoor GFCI outlet mounted to a plastic box and was going insane trying to figure out how to ground it. This was very educational.
@donwolfjr1
@donwolfjr1 7 месяцев назад
Excellent information, thank you!!! I just rewired my entire house (born in 1942) and I obviously installed a couple gfcis but EVERYTHING I did is grounded!! If it wasn't before, it is now!!!
@GettingSoberAgain
@GettingSoberAgain 2 года назад
I've been looking for these answer over 30 different videos. THANK YOU
@flashesofblack4128
@flashesofblack4128 2 года назад
Super great and concise video. Maybe I am nitpicking but the only thing a might change is the bare copper is the grounding conductor, the white is the grounded conductor, and the black is the ungrounded conductor.
@lawrence8840
@lawrence8840 2 года назад
Thanks for the link to the GFCI electric outlet tester, I ordered the one with the LCD display thru your link as well as the Wago connectors which I had been wanting...
@mpdonn317130
@mpdonn317130 Год назад
Great info. You are my go-to channel for electrical questions. Well-deserved subscription! MD
@shortypalmer2560
@shortypalmer2560 Год назад
I watched your previous video where you were fixing someone's receptacles. I am glad I did, I just ran into that at my daughter's house in Tampa. She had a relative install a gfci on an interior wall so they could be put a outside receptacle in. The gfci would not stay on. There was no ground, just the old two wires with like a cloth outside. I took apart the inside gfci and separated the wires. They had two whites on the line side and two blacks on the line side. I determined the gfci was bad ( I was wrong). Bought a new one, installed with only the line side with one white and one black, everything else went on the load side. Still did not work. Took apart the outside receptacle, they put a jumper from ground to white side. Needless to say, everything worked, I already knew without a ground it would be ok from having watched your previous video. Thanks. not an electrician, previous carpenter lol
@XTeCnOX
@XTeCnOX Год назад
This was a GREAT VIDEO! with all the details needed on this subject. Thank you very much for your service!
@makim-k5850
@makim-k5850 Год назад
This is what I thought. Thanks for the info. I'm an Ironworker and I'm rewatching an old Csi episode where a construction worker dies from electrocution and the super says a gfci won't work if the tool's ground prong is cut. But I KNEW that couldn't be correct.
@MrTooTechnical
@MrTooTechnical 2 года назад
Great vid. Another point to consider is that gfci should never be used in series on the same circuit. If multiple gfci’s are to be on the same circuit they must be connected to the line side to line side NOT load side to line side. Or else the most upstream gfci will trip and be a nuisance. Nice.
@kenbrown2808
@kenbrown2808 2 года назад
note that daisy chaining GFCIs will not cause malfunctions - it will just be annoying because a fault may trip multiple devices.
@andypoe1966
@andypoe1966 2 года назад
Awesome explanation, simple and concise. Thank you
@ednovak2224
@ednovak2224 2 года назад
OK, I was one of the 66% that had this wrong. Great explanation. Clear, concise, simple and Very Useful! Thanks..
@gloriousapplebees
@gloriousapplebees 8 месяцев назад
Thanks! Great info I'll be using this if a complete rewire is too big of a job.
@arthurfricchione8119
@arthurfricchione8119 2 года назад
Great info. Your channel is very informative. I have taken home electric courses and I’m a Diyer so everything you share is very helpful. Thanks for sharing your knowledge 😊 Artie
@bobpratt7083
@bobpratt7083 2 года назад
Good info video. Most older homes, post knob & tube era and pre romex era have BX cable attached to metal electrical gang boxes. Most of the breaker panels in those post k & t homes are grounded, and the BX cable continues that ground up to the boxes. By using that gray grounding adapter and screwing it onto the outlet plate screw a grounding path will occur. An easy test should be performed to confirm that the screw is part of the house's panel ground.
@yani365
@yani365 Год назад
Came here to say this.
@byron2521
@byron2521 Год назад
Yeah, I wondered about this. I live in an older home. I had the fuse box upgraded to a proper breaker box about 15 years ago. I also have had to change outlets to GFCI around the bathroom and kitchen sink about 12 years ago. But I still run into issues with DYI electrical issues that I am not always sure if it is O.K. Since it is an older home, at some time (don't know when) extra wiring has been added to handle more modern appliances. One issue is a 30-amp wiring to a large window AC unit. The AC is the only thing on that circuit (nothing else upstream or downstream). However, testing all the outlets I found out that one is not grounded. However, all the normal 15-amp outlets throughout the home are grounded. The AC unit itself has a breaker on the plug (so my understanding is that essentially acts like a GFCI to the unit itself). The outlet has a 3-prong outlet with an open ground. I was not sure if this was safe with no ground. Even though the cord has a breaker, I should still probably install a GFCI to prevent possible elicitation (especially being 30-amp).
@chuckhall5347
@chuckhall5347 7 месяцев назад
I have never heard of the labels. Great information as always from this channel.
@davidlyle9645
@davidlyle9645 Год назад
Great Info! Clarity is paramount!!
@mikeallen6317
@mikeallen6317 Год назад
Thank you for all your very informative clips and outstanding presentations. I did use your Amazon link to order several of your recommended tools.🔌
@edpowell5754
@edpowell5754 2 года назад
From Buffalo, N.Y. Thank You explaining this. It does most certainly help.
@enduringpursuit
@enduringpursuit 2 года назад
Thank you for another great video. the information you provide is so precise and to the point.
@patricianelson5807
@patricianelson5807 Год назад
excellent explanation. Our home inspector did highlight for us that, while recepticles had been changed from 2-prong to 3-prong (not GFCI) the underlying wires had not been changed. He described this as "common". (No label, either.) He did recommend GFCIs be put in wet areas. Based on your and other youtube input, we will be letting him know he is not giving the best advice to potential home buyers.
@okaro6595
@okaro6595 11 месяцев назад
Yes, when you do not have a ground wire it is always GFCI. The wet rule is for new installations with a ground wire.
@luminousfractal420
@luminousfractal420 Год назад
Cheers. Ive got one that has a load output on the back, but only had two wire inputs for that outlet, didnt seem right. Didnt know if i had to short the input ground to load ground.
@Michael-nt7yx
@Michael-nt7yx 2 года назад
I already knew the answer to the poll because I watched your 2 prong to gfci install before doing it myself 💪
@millomweb
@millomweb 2 года назад
Actually, the GFCI will most likely be grounded via the neutral wire.
@Michael-nt7yx
@Michael-nt7yx 2 года назад
@@millomweb I feel like you responded to the wrong person
@guygrotke8059
@guygrotke8059 3 месяца назад
Great! You mentioned how to replace other two prong outlets in the circuit after the GFCI, by connecting them to the load terminals. That was a bit of info I've sought for long time. At 5:30, you showed the cover plate for a normal three prong outlet with the two labels. That three prong outlet would have no ground wire, but would still be protected by the upstream GFCI.
@thebnbaldwin
@thebnbaldwin 2 года назад
I didn't know about the tester not working w/o a ground, thanks. Also, the GFCI has to be installed in the location closest the the breaker in order to protect all outlets upstream.
@mariamartin5186
@mariamartin5186 Год назад
Nicely put. Slow & clear. Thanks
@PhilFamolaro
@PhilFamolaro 9 месяцев назад
Excellent and very thorough explanation. Thank you.
@EverydayHomeRepairs
@EverydayHomeRepairs 9 месяцев назад
You bet!
@danielleg2616
@danielleg2616 Год назад
Very clear explanation. Do i need to ground my whole house or gfci in garage outlet?
@Quietvibes07
@Quietvibes07 Месяц назад
Thank you! I couldn’t figure out why my GFCI tester wasn’t making it trip while testing it.
@Bigfoot14000
@Bigfoot14000 2 года назад
An excellent discussion of the issue. Thanks for this video.
@skirwan78
@skirwan78 2 года назад
Great video, can't thank you enough for breaking things down to simple explanations. Would you then recommend replacing 2 outlets over to 3 prong GFCI over using the 3 prong adapters for safety? (if you have an old house like you mentioned)
@kenbrown2808
@kenbrown2808 2 года назад
yes. if you know the circuits aren't using combined neutrals, and you have a newer model breaker panel, you can use GFCI breakers - or better yet, combination GFCI.AFCI breakers, since older homes frequently use circuit designs that would have you needing to put a GFCI in every receptacle location.
@JorgeHernandez-ib1px
@JorgeHernandez-ib1px Год назад
They are now highly recommending gfci/afci for these scenarios, more safety coverage. I would love to hear you take on that or if you already covered it provide the RU-vid link. By the way, great channel.
@OrdinaryDude67
@OrdinaryDude67 2 года назад
You did a great job explaining this. 👍🏼
@apackwestbound5946
@apackwestbound5946 2 года назад
Outstanding electrical education and explanations!
@MrNorthstar50
@MrNorthstar50 2 года назад
Great explanation , I learned something today( The more you know the more you know you don't know).
@scapriglione8642
@scapriglione8642 2 года назад
Great video - useful and well explained info. Thank you!
@johnrobinson7336
@johnrobinson7336 Год назад
My 1961 home in Thousand Oaks had two prong receptacles. Installed GFI's on two wire wiring.
@ieatleftytears1953
@ieatleftytears1953 2 года назад
Thanks. You got my subscription. I have a home built pre1860
@GarryAReed
@GarryAReed 2 года назад
Excellent, thank you for the refresher ! 👍👍👍👍👍
@dandearman2871
@dandearman2871 2 года назад
One thing people shouldn't do is make their own extension cord with a standard GFI in a box on the end. For the GFI to work there must be power to it from the hot and common wire. If the cord would somehow get damaged and the neutral wire breaks, the GFI will no longer trip leaving the hot side of the GFI energized. The commercially made GFI extension cords have a voltage monitoring circuit that removes both hot and neutral from the receptacle if there is a break in either conductor. If you still want to make your own GFI extension cord, Hubble sells a cord end that has a GFI and the voltage monitoring circuit together.
@tek4
@tek4 2 года назад
I can see the logic, but if someone was dead set on doing the box on a cord route, I would hope the minimum would be a gfi outlet on it.
@fromagefrizzbizz9377
@fromagefrizzbizz9377 2 года назад
If you wire an extension cord with a GFCI on the end, and the neutral in the cord breaks yes, the GFCI won't trip. But, while the hot wire is still energized it likely will still trip if the hot conducts any current (like thru you to a copper pipe). Because the neutral current flow is zero, and the hot isn't.
@MarkLawry
@MarkLawry 2 года назад
Thanks for pointing that out. Makes sense.
@xHadesStamps
@xHadesStamps Год назад
Ideally it's plugged into a GFCI protected outlet. Ideally.
@okaro6595
@okaro6595 11 месяцев назад
That is why in Europe, at least in Finland RCDs need to be voltage independent i.e. not electronic. As there is no electronics it works even without power. But if you make an extension cord it is better to put the protection to the plug so it protects if the cord gets damaged and you get shocked from it.
@dngriffiths8105
@dngriffiths8105 Год назад
Important and very well explained, well done.
@tonym6920
@tonym6920 2 года назад
Very good information, thanks!👍👍.
@dougc78
@dougc78 2 года назад
67% I got it wrong too! Thanks for another excellent and informative video.
@gileon6212
@gileon6212 Год назад
I immediately subscribed because you answered the question immediately instead of stringing it out
@freelanceminion7396
@freelanceminion7396 Год назад
I have a house from the 1960s and many (but not all) outlets do NOT have a ground, and I am glad to learn a GFI will make the circuit at least more safe if not entirely as safe.
@babyyoda2219
@babyyoda2219 Год назад
Hi thanks for the video. I'll be installing an electric shower head in Mexico. Fairly sure the heating unit doesn't have any internal short/trip protection. The house is brand new but no idea on how up to code it is in terms of proper neutral. Theoretically Will the GFCI without ground be enough for safety to trip protection if something goes wrong with the unit/water gets in the circuit etc
@randyaivaz3356
@randyaivaz3356 Год назад
Just Like to add to your good info. Many look at the Hot Leaking or touching to ground as the Cause of Tripping, Neutral touching ground will also cause it to Trip, as Ground would be carrying Current. Hot and Neutral need to Draw Equal, any Difference, then they Trip.
@javiervaldes5884
@javiervaldes5884 Год назад
Thank you my friend you have been a great help.
@keithlong2788
@keithlong2788 Год назад
Great video! Had a fee questions. I have a home that was built in 1955 and had a lot of thise two prong outlets that were replaced with 3 prong outlets. Some of the circuits have a ground back to the panel and some don't. Most outlets were converted from one gang to two gang. There are also some outlets added to existing circuits via metal junction boxes that are not grounded because there were no grounds to bond the box. These GFCI sound like they could make my situation safer. I will replace the breaker though instead of individual outlets so the whole circuit is protected. If I put the GFCI breaker in will circuits that have ungrounded metal junction boxes be protected as well as any otjer ungrounded outlet. Also, can I continue to use the 3 prong outlets with no grounds as long as I have a GFCI breaker in and I label the outlet "not grounded"? In other words does the gfci have to be in the outlet because of the 3 prongs or is the gfci breaker ok?
@RadioRich100
@RadioRich100 Год назад
This jackass wont know.
@StephenBradley2317
@StephenBradley2317 2 года назад
Box clearance is an issue in my old home, as is the fear of damaging these old wires. An electrician said that replacing my breakers with combination arc-fault/GFCI breakers might be a good idea, however I thought the lack of a ground wire negated that?
@ronmartinkus4135
@ronmartinkus4135 Год назад
Fabulous Video. THank you, Sir.
@marcellaschechter7411
@marcellaschechter7411 2 месяца назад
Thank you. You answered all my questions
@humbertorivera1718
@humbertorivera1718 2 года назад
Thanks for the information is very helpful.
@briansiedenburg2514
@briansiedenburg2514 2 месяца назад
Great video! You mentioned the duplex outlet that run from the load side for GFCI protection - Im looking to do this, do have a video detailing that by chance? Half of my house is ungrounded and looking to do that.
@gordduncan5859
@gordduncan5859 2 года назад
I was raised in a home built in the early 1940's with post and tube wiring. When Dad put bedrooms in the attic he used Romex with no ground. I had a couple of Short Wave radios up there and to improve the reception we ran a bare ground wire beside the septic tank stack down to the basement where it was connected to the copper pipe bringing our water in from the street. My Mother was vacuuming my room when the vacuum cleaner's metal wand contacted the bare copper wire with a bright blue spark and the fuse blew. We were fortunate no-one was electrocuted! I have worked since then in a large metal stamping plant and noticed that heavy bare ground wires in the open had green insulation. We tend to think that a bare ground wire is safe because it is at zero volts; BUT combine it with a hot appliance or tool in your hand and it now very dangerous!!
@KevinT3141
@KevinT3141 2 года назад
In that particular case it was the vacuum cleaner that was dangerous, the exposed ground just highlighted the problem for you before it killed someone. Edit to add: A GFCI outlet would have prevented the blown fuse.
@michaelholliday100
@michaelholliday100 2 года назад
Ground Wires never carry electricity to ground unless there is a short circuit.
@goodun2974
@goodun2974 2 года назад
@@KevinT3141 , There are advantages to our modern vacuum cleaners and double-insulated power tools made with plastic cases: it's far less likely that the user will contact a hot or live chassis in the event of an internal fault in the device. I can remember getting zapped as a kid when using my dad's old metal-case Stanley power drill while standing on the basement concrete floor barefoot or in damp sweaty leather mocassins. A few years later we upgraded to double insulated double insulated Bosh tools with plastic cases, which didn't give you shocks even though they did not have a grounded cord. This was of course in the long ago days when powerfull cordless tools weren't available.
@jagwindowtintingtreatments2431
@jagwindowtintingtreatments2431 5 месяцев назад
well done! Nicely explained. Thank you.
@TheFearlessFitness
@TheFearlessFitness 6 месяцев назад
Thanks for this awesome video!!!! Quick question. So if I am using a GFCI on an ungrounded outlet, I shouldnt get electricuted if I plug a heating pad into the same outlet correct?
@okaro6595
@okaro6595 6 месяцев назад
You would not get electrocuted even without it. It always requires an equipment fault for the risk to actualize. With a GFCI the power is cur before you get a dangerous shock. It may still sting.
@MrLinkiscute
@MrLinkiscute 2 года назад
On old two wire systems, can you pigtail the ground lug to the white to make the tester work?
@okaro6595
@okaro6595 2 года назад
No and the question is strange anyway. Why would you want the tester to work? The proper way to test is the test button.
@Uruguay714
@Uruguay714 2 года назад
In an old condo, where the ground is provided by the metal conduit attached to the breaker panel, and metal conduit is used to connect all the outlet locations, CAN you screw a short piece of wire to a metal outlet box then to the ground on the GFCI ? Would that possibly have ground? How do you test for ground?
@bravebluechickadee
@bravebluechickadee 2 года назад
Thank you. I was wondering about this just the other day.
@EverydayHomeRepairs
@EverydayHomeRepairs 2 года назад
You bet 👍
@millomweb
@millomweb 2 года назад
The ground to a GCFI will most likely be provided by the neutral wire. If not then a GFCI is not needed !
@mikealadams1885
@mikealadams1885 2 года назад
Outstanding explanation. Thank you!
@EverydayHomeRepairs
@EverydayHomeRepairs 2 года назад
Thanks!
@gordongustafson9686
@gordongustafson9686 2 года назад
Great explanation. Thank you
@nroman1977
@nroman1977 Год назад
You forgot about a few places like Cook County Illinois where we use metal conduit and Romex is prohibited. The metal conduit acts as ground and is routed back to the Fusebox as such. In situations that have flexible metal conduit over 6ft or over a specific amperage you must run a dedicated ground back to the nearest rigid conduit metal box.
@samueladams4145
@samueladams4145 11 месяцев назад
Does running a bare jumper from the neutral post to the ground post on the GFI receptical, and the downstream recepticals, help? Thanks for the reply.
@johnmason5488
@johnmason5488 Год назад
Thank you very much for this informative video
@margaritam8140
@margaritam8140 9 месяцев назад
I have a ridiculous situation here. We have an old house in Pittsburgh probably 110 years old and i really love learning about all things electrical and feel i totally missed my calling so thank you for all your informative videos! ANYWAY, I popped open an old outlet here with what looked like a ground wire BUT some sneaky SOB 😸 had simply ran a copper wire from that outlet to another outlet directly on the other side of that wall. Now, I'm wondering if i should do the same with the GFCI outlets I'm about to install or if i should completely just yank that "wanna-be ground wire" out of the wall? Will it even serve any purpose? Everytime i think I've seen it all in this house, i find something new to shock and awe 😸. Hopefully not shock, literally though 😹. Thank you again!!!
@fromagefrizzbizz9377
@fromagefrizzbizz9377 8 месяцев назад
That wannabe ground was likely legal when it was done, but it was usually done to a water pipe. Code has changed, in part because plastic pipe is so common even in Reno’s. The only way to be sure is to ask a local inspector, who’ll likely say leave it alone, just don’t do any more. Do NOT do it with the gfci outlets, it’s totally unnecessary. Once an outlet is protected by a GFCI the only reason to have a real ground is to provide a quiet ground reference for high end audio equipment or amateur radio.
@chrisunderwood4865
@chrisunderwood4865 2 года назад
Good info here.Thanks.
@JacquiVreeken
@JacquiVreeken 2 месяца назад
Thanks for the simple explanation. My remaining question is: does one GFCI on each circuit protect any remaining two-prong outlets on the same circuit? Or would each outlet need to be replaced with a GFCI in order to provide that level of protection? Thank you!
@architectofheaven
@architectofheaven 2 года назад
I tried to install a Leviton GFCI in my home - which is wired with old BX and relies on the armor to ground out the metal boxes. In this particular location, a bathroom, some moron had mounted the box flush to the STUD and so there was a layer of drywall and a layer of ceramic tile in front of it ... so the outlet had to float way off the box. Because of this, you couldn't get a reliable ground from contact with the box. My experience is that, in this situation where the GFCI was not connected to ground, the device would not energize ... it would trip as soon as you put power to it and would not reset. I had a box of these GFCIs and tried three different devices and all had the same behavior. In the end, I ran a screw into one of the holes in the back of the metal box, put a ring terminal on a piece of ground wire, and connected that to the ground terminal of the GFCI - problem solved and all worked as expected. So, I think at least some of these devices require a ground connection.
@UntouchedWagons
@UntouchedWagons 2 года назад
There's a Technology Connections video that goes into detail about how GFCIs work that's quite good.
@robert.arnone
@robert.arnone Год назад
For the labeling of outlets, I know this is mandatory from NEC. Does the Canadian CEC have similar requirements?
@johnmunaretta5290
@johnmunaretta5290 Год назад
Your exactly right been saying this for years ground is good but GFCI reads between hot and neutral not ground and will trip if different amps between hot and neutral 5 Mil amps! Back in the day sharing neutral with another phase will not work with GFCI Breaker . Example A Phase pulls 12 amps on its own so Neutral pulls the same 12 amps GFCI WILL NOT TRIP. But if you share Neutral with B phase that pulls 10 amps the Neutral will have 2 amps on it the difference between the two loads , the GFCI sees this as a fault and will trip since A phase hot has 12 amps on it and the Neutral will only have 2 amps since is sharing the 10 amp B phase load
@bungalowlivin
@bungalowlivin Год назад
Question....is it better to install GFCI/AFCI Combo Receptacles to replace older homes 2 prong receptacles or just GFCI type?
Далее
Incredible magic 🤯✨
00:53
Просмотров 10 млн
КОРОЧЕ ГОВОРЯ, ШКОЛА БУДУЩЕГО
10:40
How to Fix an Open Ground
13:05
Просмотров 615 тыс.
Can 15 Amp Outlets Be Used On A 20 Amp Circuit Breaker
8:13
Can You Replace A 2-Prong Outlet With A 3-Prong?
12:55
What is a Suicide Cord and Why It Could Kill You
16:28
People Are Adding Deadly Hacks to Outlets
8:54
Просмотров 1,1 млн
Replacing A Standard Outlet With A GFCI Outlet
7:38
Просмотров 659 тыс.
Fix Open Ground Outlets | 4 Options
6:40
Просмотров 7 тыс.
Get Yours From Our Profile Description 🙏
0:19
Просмотров 19 млн
Slow Mo Spiral
0:11
Просмотров 21 млн
easy game filter 😎
0:12
Просмотров 7 млн