Electricians Day On The Job // Fire Alarm . 

CJR ELECTRICAL
Подписаться 230 тыс.
Просмотров 37 тыс.
50% 1

Another day on the job , installing some extra call points onto a standard non addressable fire alarm system . Music by Joakim Karud Dreams and day good night .

Хобби

Опубликовано:

 

25 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 58   
@tonydavison3312
@tonydavison3312 6 лет назад
Get the tools away and “get the hell out of dodge” Great video top work dude!
@johnschlesinger2009
@johnschlesinger2009 5 лет назад
Great job (as usual).
@LukeWilson2003
@LukeWilson2003 6 лет назад
Great job as always
@jameseverett2433
@jameseverett2433 6 лет назад
Please make more videos of your installs of fire alarms, great video mate really enjoyed it!
@Danny-do2ov
@Danny-do2ov 6 лет назад
Top Video again mate. Keep up the good work bud.
@abrahamuk7403
@abrahamuk7403 4 года назад
Thank you, that's great
@nickbuckle646
@nickbuckle646 6 лет назад
Like the band strap idea. For round cables try the jokari tools great for fp. Have you tried the concrete screws like wall dogs for mounting your fire Alarm stuff no ralw plug required which I am told is the way to go these days.
@DanstheEngineer
@DanstheEngineer 6 лет назад
Thanks for the shout out. Someone told me about your videos. Keep it up. 😎
@LukeWilson2003
@LukeWilson2003 6 лет назад
Dans the Engineer and I wonder who that was....
@Baggiolyful
@Baggiolyful 6 лет назад
Love the smell of fp 😌
@TheFireAlarmChannel
@TheFireAlarmChannel 4 года назад
I know it's an old vid now but your not allowed to use plastic clips for fire alarm cable metal only, 300 on the horizontal 400 on the vertical
@shanestockton3871
@shanestockton3871 6 лет назад
Love how you made a tidy jobs of it but a shame the place blocks up one of the fire exits so you can't get out of it made me laugh.
@lukewheeler2586
@lukewheeler2586 6 лет назад
I can never see the band playing the laid back easy jazz music. Must be just off screen.
@Monkey3353
@Monkey3353 4 года назад
great job can you show me how to wire in a panel 👍👍👍
@williamsullivan5733
@williamsullivan5733 4 года назад
What you call "trunking" we call "wire mold" here in the U.S. also, our plenum wires have a string in them so you don't have to risk knicking the wire. Just strip an inch off the end and pull the string.
@WarrensRandomAndWeirdVideos
how stupid are you Americans
@Trade920
@Trade920 6 лет назад
Great videos enjoy your content, you mentioned about the end of line resistor, can you explain why they are needed in the circuit and are they only used when a radial zone/circuit is installed? any advice on this would be greatly appreciated
@county582
@county582 5 лет назад
It is to monitor the line in case someone takes a device off or one isn’t connected properly it will show a fault at the panel the panel will always look for a healthy resistance depending on panel type
@antonios4926
@antonios4926 3 года назад
@@county582 Thanks for that info
@asef698
@asef698 6 лет назад
Hi mate. Should metal rawlplugs be used when installing fire cable or is it just the fitting which needs to be metal.
@ahkeelahmed9423
@ahkeelahmed9423 4 года назад
Use walldawg screws made by dewalt they are fire rated and you dont need any rawlplugs
@AutoUnder
@AutoUnder 5 лет назад
Don't new call points require stopper covers now?
@piotr0290
@piotr0290 6 лет назад
Hi. What size of fp200 cable do you use for fire alarms? Cheers 👍
@Danny-do2ov
@Danny-do2ov 6 лет назад
1.5mm mate
@clandis5813
@clandis5813 4 года назад
you need to get a glow rod my guy
@antonios4926
@antonios4926 3 года назад
Thanks for the video. So an EOL resistor can be fitted on a manual call point too if that is the last device.
@nonamefornow1465
@nonamefornow1465 3 года назад
Yes
@antonios4926
@antonios4926 3 года назад
@@nonamefornow1465 Efharisto Demetri
@nonamefornow1465
@nonamefornow1465 3 года назад
@@antonios4926 nothing mate
@robcamm7584
@robcamm7584 6 лет назад
Hey mate, whats the tool bag you are using, looks pretty sweet, can you review/recommend please
@Cjrelectrical
@Cjrelectrical 6 лет назад
It’s the Stanley fatmax back pack I’ve done a review if you look back at my older videos .
@robcamm7584
@robcamm7584 6 лет назад
The cjrshop thanks, I actually saw it just after I asked, great vids mate, very informative, just qual’d myself and am geared up to go... like your approach, quite inspirational.. thanks
@crew4670
@crew4670 5 лет назад
how much would it be to install all that system just wondering because I need someone to install them in my house.
@Andrew_Tate_Personal
@Andrew_Tate_Personal 5 лет назад
kai gregory call your local fire alarm company. Prick
@crew4670
@crew4670 5 лет назад
@@@Andrew_Tate_Personal maybe because I don't want to spend a lot of money on a company that charges a lot for an hourly rate
@markdavies7212
@markdavies7212 3 года назад
Why didnt you just come off one of the devices in the same room you was putting the extra devices?
@antonios4926
@antonios4926 5 лет назад
Thanks for the video. What size resistor do we fit at the last device?
@antonios4926
@antonios4926 3 года назад
@Ronnie Roo Many thanks
@cantbelieveimhere2935
@cantbelieveimhere2935 3 года назад
Its a Ctec panel, so a capacitor goes EOL on the alarm circuits & a 6k8 resistor goes EOL on the sounder circuit. It looks for 470ohms to trip it into fire.
@antonios4926
@antonios4926 3 года назад
@@cantbelieveimhere2935 Thanks for the reply
@testlogs9005
@testlogs9005 6 лет назад
great video mate, i will have to admit i did cringe when you used the sticky back trunking, really not a fan of that stuff.
@Khanjan-si8me
@Khanjan-si8me 6 лет назад
Hi can you tell us the name mini trunk cutter .
@Cjrelectrical
@Cjrelectrical 6 лет назад
The ones I use are here enjoy www.cnspowertools.co.uk/rothenberger-52000-plastic-pipe-cutter-0-42mm?gclid=EAIaIQobChMI_5Hj7bHl3AIVZZPtCh1akguvEAQYAyABEgLbIfD_BwE
@jamchan6436
@jamchan6436 5 лет назад
What brand is the fire panel you installed ?
@LukeWilson2003
@LukeWilson2003 4 года назад
C-Tec
@mrhaydon
@mrhaydon 6 лет назад
When fixing the trunking back, should you also be using metal plugs?
@nathangatenby5744
@nathangatenby5744 6 лет назад
Why would you do that, the trunking would still melt in a fire.
@Cjrelectrical
@Cjrelectrical 6 лет назад
It’s still a very grey area at the moment manufacturers are taking a while to develop suitable fixings , you can buy screws which you drive straight into concrete or brick which are good , I always strap my cables directly above , so they would never hang over a doorway or exit .
@Cjrelectrical
@Cjrelectrical 6 лет назад
Raw plugs can melt and the whole lot would be hanging in an emergency exit .
@asef698
@asef698 6 лет назад
Nathan Gatenby the fixing and cable wouldn't be dangling and hanging down causing a hazard. I think it won't be long before all cable has to be tied back with metal rawl plugs along with fixings. One of the main reasons for fighter deaths is through getting tangled in fallen cable. Albeit this is only a small building.
@alexcantley9137
@alexcantley9137 6 лет назад
ashley sefton plastic rawlplugs are responsible for at least 50 000 fire fighter deaths a year .if you think about it grenfell was the biggest fire the UK has seen how many fire fighters or residents for that matter were killed by dangling cables .it's a case of a problem being invented by governing bodies after a bung has been recieved and solved by manufacturers after paying the bung call me cynical PS I think if your still in a burning building when the rawlplugs have had a chance to melt youve got bigger problems than dangling cables
@tombickerton5909
@tombickerton5909 6 лет назад
Get a vw caddy
@marjusdedja9408
@marjusdedja9408 3 года назад
Im a eletrician in albania
@antonios4926
@antonios4926 3 года назад
eleni foureira very nice
@samanranasinhe132
@samanranasinhe132 4 года назад
You're company please fire alarm job Sir your company no wakansis
@FinlaysFireSystemsElectrical
@FinlaysFireSystemsElectrical 2 года назад
alarm sense is cheap and not very good, its one of apollo's worst ranges if you ask me, your much better off with apollo xp95 or apollo series 65. apollo discorvery is also good but alarmsense is quite frankly shit.
Далее
Она Может Остановить Дождь 😱
00:20
False fire alarm activation in garage
6:59
Просмотров 29 тыс.
I love stripping out my own work!!
10:36
Просмотров 83 тыс.
CJR ELECTRICAL Fault finding someone else’s work!!!!
12:45
Are fire alarm systems supposed to be like this?
12:38
Что она делает?
0:34
Просмотров 12 млн
Пов: Несёшь цветы маме🥺
0:31
Просмотров 2,3 млн