Тёмный

Fast and Easy Clean Out of Condensate Lines on an Air Conditioner! 

AC Service Tech LLC
Подписаться 498 тыс.
Просмотров 1,5 млн
50% 1

In this HVAC video, I go over several easy ways to clean out the Condensate Line Trap on an Air Conditioner. A P-Trap, U-Trap, or Running Trap may clog without the preventative maintenance of cleaning the trap and line. I discuss the Emergency Condensate Safety Switch on the secondary drain pan outlet which can avoid damage from occurring if there is a problem such as a clogged condensate line. Supervision is needed by a licensed HVACR Tech while performing tasks as Experience and Apprenticeship garners Wisdom and Safety.
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our Related Videos
• Why a Condensate Trap ...
• Does a Wall Mounted MI...
• Why the Furnace Pressu...
• Fast and Easy Clean Ou...
• HVAC Installation Trai...
• Condensate Drain Traps...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Educational Books, E-Books, Workbooks, Cards, Posters, and PowerPoints:
All Our Educational Products on Our Site: www.acservicetech.com/store
All Our Educational Products on Amazon: amzn.to/48pDd82
Mini Split Book and E-Book on Our Site- www.acservicetech.com/mini-sp...
Mini Split Paperback on Amazon- amzn.to/3ytHJSs
Mini Split Paperback on TruTech Tools- www.trutechtools.com/BooksGui...
Refrigerant Charging Book and E-Book: www.acservicetech.com/ac-book
Refrigerant Charging Paperback on Amazon: amzn.to/46xTeHf
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Our HVACR Online Resources!
Our HVAC Calculators: www.acservicetech.com/hvac-ca...
Our Newest Articles: www.acservicetech.com/articles
Try our HVAC/R Quizzes! www.acservicetech.com/quizzes
Our Other Resources: www.acservicetech.com/resources
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Tools Used in Our Videos!
Tool Links on Our Site: www.acservicetech.com/tools
Our Tool List on Amazon: www.amazon.com/shop/acservice...
Support the Channel by purchasing tools through TruTech Tools!
Use this link www.trutechtools.com/?aff=8
Save 8% at checkout using code "acservicetech"
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Follow Us On Our Social Media & Podcasting Channels!
Patreon: / acservicetech
Facebook: / acservicetech
Instagram: / acservicetech
X: / acservicetech
LinkedIn: / ac-service-tech-llc
Tiktok: / acservicetech
Spotify: open.spotify.com/show/74KXLz5...
Apple Podcasts: podcasts.apple.com/us/podcast...
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
⚠️ Disclaimer:
Information in this video is intended for educational purposes only. Any work related to the topics in this video should be performed by licensed technicians or by apprentices under the supervision of licensed technicians. AC Service Tech LLC is not responsible for any possible damages or injuries caused by the use or misuse of any information provided.
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
#hvacr #hvacr #hvactrainingvideos #hvactraining #hvactraining101 #acservice #acservicetech #acunit #airconditioner #function #install #airloss #drain #draintrap #condensatedrain #condensate #condensateline
▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal.

Опубликовано:

 

12 май 2018

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 401   
@acservicetechchannel
@acservicetechchannel 6 лет назад
Tool List- www.amazon.com/shop/acservicetech Support- www.patreon.com/acservicetech For those that are looking for the tools used in the videos: (Linked Below) Here is the link for the Rectorseal SS2 condensate float switch-amzn.to/2rEQJBb Here is the link for the Rectorseal SS3 condensate float switch-amzn.to/2jkry4X Here is a link to the Hydrex Condensate tablets- amzn.to/2z4DAno Here is the link to the RectorSeal EZTrap 230 U-Trap with float switch amzn.to/2IbL7cT Here is the link for the nitrogen blowout tool- amzn.to/2IeOpfi Here is the Link for the newer UEI DL479 Multimeter with temp sensor- amzn.to/2jtsUbJ Here is the Link for the FieldPiece ST4 Dual Temp Meter- amzn.to/2AhR6ph Other tool links can be found in the video description section. Shop through Amazon! Your Purchases through Amazon provide a means for channels such as mine to earn advertising fees from all purchases after clicking through. Prices are the same as normal- www.amazon.com/shop/acservicetech All of the ACSERVICETECH Playlists- ru-vid.com/show-UCOZR-1IqsAer9wzlvFgb4mAplaylists?view_as=public
@reelivin8112
@reelivin8112 9 месяцев назад
Retired hvac/mechanical 42 + years, native Floridian who has dealt with these issues my entire life. Best quick fix is to use a small shop vac for 2 reasons, 1- the hose end actually fits over the 3/4” line end nicely and you can feel the water/algae/ etc coming through the hose, 2- less messy and cumbersome, once cleared just take a quart or so of water with 2 oz of bleach and pour into your empty system. The small amount of house bleach will not hurt a thing along with the new water from condensation. We do this every 45 days at our residence from April until November just do to algae and particulate buildup in the lines, high humidity does not help. Hope this helps
@funkycowboy
@funkycowboy 9 дней назад
Where do you connect the shop vac to, the inside PVC or the outside PVC where is drains to the outside?
@CampRocknRoll
@CampRocknRoll 9 дней назад
@@funkycowboy outside
@so-what5991
@so-what5991 8 дней назад
@@CampRocknRollI just unclogged my drain. I was having weak airflow. Is this a symptom of this. It seams like it’s working better.
@funkycowboy
@funkycowboy 8 дней назад
@@CampRocknRoll I'm in a second floor condo and the HVAC is in the attic. The PVC run is probably 40 feet to the outside.
@CampRocknRoll
@CampRocknRoll 8 дней назад
@@so-what5991 Your drain won’t affect airflow. If you have a float switch, then when it clogs it shuts the compressor down while keeping the fan on. What you’re experiencing is when the compressor is off then there’s no cooling happening and it harder to feel the air when it room temp
@samquinn6427
@samquinn6427 5 лет назад
I lived in FL for 20 years and a small shop vac connected to the outside with best way to clear the line. First pour a cup of white vinger into the inside line near the air handler and wait 5 minutes and then shop vac from the outside. Clears the line every time.
@acservicetechchannel
@acservicetechchannel 5 лет назад
Yes that will work very well for lines that are not pitched correctly and have standing water stuck in the pvc line within the building. If the tubing is pitched correctly then only a very small amount of water will come out but if it is not pitched correctly then a lot of water will end up in the vacuum container, thanks Sam!
@collingrimes2646
@collingrimes2646 4 года назад
Thanks, Sam. I tried this before I went and bought supplies and it worked like a charm.
@singletilltamed
@singletilltamed 4 года назад
Lol the thought to this yesterday night just came to me and man did it work amazingly well. The gunk in pipes were no match for my 50gallon wet vac.
@howardhightower5904
@howardhightower5904 3 года назад
I tried that & it didnt work. Have > 20 feet of pipe laying nearly flat in attic. Outside with vac could suck out water but then would not drain during use.. But if I did not pour cup of vinegar down each day, water stopped draining. I used 5% & 30% vinegar every day for 3 weeks. Then BIG bubbling inside when I poured down & since then = no problems. Builder STUPID put ac in attic with no roof exhaust fan. Extra hot stress on unit. Richmond, VA can get 90-100 typical day = 135-155 in that attic.
@livingadreamlife1428
@livingadreamlife1428 3 года назад
Live in Fl and have to don this regularly
@markushorner1991
@markushorner1991 3 года назад
Having worked as a handyman for many years. I can say that this method is the best way to solve your problem.
@bobstratton6362
@bobstratton6362 3 года назад
I always use a wet-dry vacuum, sucks out the junk and you can clean the unit and area. carrying in a bottle a bottle of gas is another trip.
@Scooter9480
@Scooter9480 3 года назад
I wanted to thank you so much ! I did have a clog. You saved me hundreds, no doubt. Thanks, guy ! Very grateful !!!
@acservicetechchannel
@acservicetechchannel 3 года назад
Glad it helped!
@michaellevine9847
@michaellevine9847 2 года назад
This was the suggestion that worked for me and I will know to maintain it later. Thanks for saving me some bucks and giving me some confidence
@marcusdarnell3348
@marcusdarnell3348 4 года назад
Thanks I have learned so much from your videos! This is online training at its best!
@acservicetechchannel
@acservicetechchannel 4 года назад
Glad to help Marcus!
@westcoastrepairshandymanse4682
@westcoastrepairshandymanse4682 4 года назад
Outstanding video with some great tips.
@electronixTech
@electronixTech 3 года назад
I subscribed and bought the e-book. I don't work in the HVAC field but have been working on my own central AC at home and this e-book is the best source of information I have come across. It's answered a lot of questions I haven't been able to find anywhere else and well worth the money. Thanks.
@CampRocknRoll
@CampRocknRoll 9 дней назад
illegal
@electronixTech
@electronixTech 9 дней назад
@@CampRocknRoll Wrong!
@annjansen4687
@annjansen4687 Месяц назад
Excellent video. Concise and clear. THANK YOU!!
@emmakateodwyer345
@emmakateodwyer345 10 месяцев назад
Inexpensive with lots of power. Provides cool air needed during the hot Sacramento summers!
@rumplestillskin6157
@rumplestillskin6157 3 года назад
Great video. Well thought out and consistent info and explanation.
@acservicetechchannel
@acservicetechchannel 3 года назад
Much appreciated!
@thedauberstopperbymacp1773
@thedauberstopperbymacp1773 4 года назад
Very helpful information AC Service Tech LLC, thanks! Incidentally, we have a product that protects the exterior opening on the emergency condensate lines by keeping insects out.
@bernieclement3373
@bernieclement3373 6 лет назад
I like to use shop vac with some clear hose and use foam tape to fit the shop vac end and a little as needed to fit drain line, also can see the gunk you get out. Works great in buildings with fan coil units.
@acservicetechchannel
@acservicetechchannel 6 лет назад
That is certainly a great way! thanks Bernie!
@3boymom3
@3boymom3 11 месяцев назад
So thankful for this video.
@donnierobertson3088
@donnierobertson3088 3 года назад
Nice job and video like always
@user-wh8lw6xo9x
@user-wh8lw6xo9x Год назад
*Easy to instal **Fastly.Cool** As described.*
@sylnyiasmith6183
@sylnyiasmith6183 6 лет назад
love your work. I learn something every day from your videos. If possible, could you make a video on removing/replacing slanted coils?
@acservicetechchannel
@acservicetechchannel 6 лет назад
Thanks Sylnyia, I will keep that in mind
@keithhoward8651
@keithhoward8651 6 лет назад
Nice, Thanks for the info.
@acservicetechchannel
@acservicetechchannel 6 лет назад
Thanks Keith!
@markeylaguyton216
@markeylaguyton216 5 лет назад
Thanks to this video ❤ i was able to restore my ac on my own
@acservicetechchannel
@acservicetechchannel 5 лет назад
Thanks!
@DV7777-
@DV7777- Год назад
Will be very helpful for the future. Apparently I used too much water and the A/C shut off. I called my A/C company but they could not make it out for 4 days since it's been 100+ degrees these past few days. I was going to contact my neighbor for help also but decided first to blow my box fan on the unit and within an hour, the A/C came back on. Lucky or it just cleared on it's own. But like I said, will use your helpful info in the future. Thanks; very easy to follow your instructions.
@1MNUTZ
@1MNUTZ 6 лет назад
best hvac channel on youtube
@acservicetechchannel
@acservicetechchannel 6 лет назад
Thanks 1MNUTZ!
@petera.knight-sewall8208
@petera.knight-sewall8208 3 года назад
Good video, keep up the great job!!!🙂🙂🙂
@acservicetechchannel
@acservicetechchannel 3 года назад
Thank you! Will do!
@medievalmusiclover
@medievalmusiclover 5 лет назад
So great very professional guide. Than You.
@acservicetechchannel
@acservicetechchannel 5 лет назад
Thanks Medievalmusiclover!
@tankttehctiw8776
@tankttehctiw8776 6 лет назад
Another great video
@acservicetechchannel
@acservicetechchannel 6 лет назад
Thanks Tank!
@florantemanuel5000
@florantemanuel5000 4 года назад
An old air mattress inflator (corrugated) tubing connected to the air compressor blower/gun sealed with duct tape does the trick too. The idea is to get into the p-trap and blow air into it.
@whitesheatingairappliancer7101
Great video thank you.
@acservicetechchannel
@acservicetechchannel 6 лет назад
Thanks Ron!
@sidfinley6087
@sidfinley6087 5 лет назад
Very helpful, thanks!
@acservicetechchannel
@acservicetechchannel 5 лет назад
Thanks Sid!
@sitocuh
@sitocuh Год назад
I love your videos.
@deanmartin1966
@deanmartin1966 6 лет назад
Great tip
@acservicetechchannel
@acservicetechchannel 6 лет назад
Thanks DeanMartin1966!
@bertotrevino9043
@bertotrevino9043 3 года назад
Sweet baby Jesus! Thank you. I've been trying to make something for those t fittings.
@jacklabloom635
@jacklabloom635 3 года назад
That AC drain switch is a good idea, but be careful, I had one connected like the one shown in the video and water still leaked from the pan without shutting off the unit, because the water level raise needed to activate the cutoff switch was higher than the pan overflow. This leaking water caused considerable damage over time. The water was going into the plenum located beneath the house. Mold grew and one day we came back to our cabin and the house smelled terrible. The insulation inside the sixty foot long plenum was full of mold. It cost a lot of money to have all the insulation removed. All the air ducts and plenum then had to be cleaned. The truck used to evacuate the plenum and duct work had a huge suction machine that pulled every lose particle out while the workers inserted spinning brushes inside the air ducts and plenum. Once clean, the plenum was sprayed with a chemical that killed the mold. The the entire House and air duct system had to be gassed with Chlorine dioxide to kill any mold in the interior. . The guys who did this wore suits and breathing gear. They looked like astronauts. The house then had to sit for three days unoccupied. The plenum was then insulated on the outside. My total cost was five thousand dollars. I solved that switch problem on my unit by adding an offset coming directly out of the unit which allowed me to place the cutoff switch a half inch lower down. Now it works perfectly like it was designed to work. After my experience, I would never place that cutoff switch straight out level on any unit. I also added cutoff valves and a water hose input to my drain pipe, so I can flush my entire drain pipe ( 23 feet long ) twice a year with my water hose. I never want to have another stopped up drain pipe on an air conditioner again.
@DLmohh
@DLmohh 2 года назад
Damn
@gaylefriedman3773
@gaylefriedman3773 Год назад
I'm so happy you had all this work done. Wow, it was costly. This is another reason why I don't like Condensers on a Roof-Top. You can't get to this Unit, and it needs attention. I expected after 40 Years of Residential/Commercial A/C, that there would be little to no problems. Keep in touch.
@CrustyChucky
@CrustyChucky 9 месяцев назад
Almost exactly what happened to me. The float was never raised by the water.
@BayAreaMCs
@BayAreaMCs 4 года назад
Thank you!
@MsSexyDiva4Lyfe
@MsSexyDiva4Lyfe 3 года назад
Great video! My air man told me to pour a cup of bleach each month down that drain to prevent clogging. Of course I ain’t do it in 6 months and now...here I am! Update!!! I went to the store, bought a tube, put it down the pipe and blew....checked later and my drain pan drained itself! Thanks for this video! Saved me a ton, called an AC company and they said $150 just to come out!!! I bout a $3 roll of tube and fixed it myself!!!
@stevenmoomey2115
@stevenmoomey2115 3 года назад
Salt will work just as well as Bleach and is much safer. It works by a Osmosis. Put a couple Tablespoons of Ordinary Table Salt or Rock Salt, in the Drain, so it sets in the trap.
@stevenduplantis9436
@stevenduplantis9436 5 лет назад
U taught me something! Thanks
@acservicetechchannel
@acservicetechchannel 5 лет назад
Thanks Steven!
@writebrained
@writebrained 3 года назад
Dude, ur a lifesaver. Thnx!
@acservicetechchannel
@acservicetechchannel 3 года назад
Happy to help
@jackfarrell4727
@jackfarrell4727 3 года назад
Thank you for the information
@acservicetechchannel
@acservicetechchannel 3 года назад
My pleasure
@sam999ber
@sam999ber 2 месяца назад
Great video
@hornmtn
@hornmtn 17 дней назад
Thank you!!!!!
@jwsnotruth7106
@jwsnotruth7106 3 года назад
i use boiling water when i do my tune ups i liked your video alot !
@OthmanAlikhan
@OthmanAlikhan Год назад
Thanks for the video =)
@acservicetechchannel
@acservicetechchannel Год назад
My pleasure!
@ezorro5920
@ezorro5920 2 года назад
I also pour a capful or two of chorine down the trap once or twice in the A/C cooling season to help prevent molds from growing in the water.
@r-l2536
@r-l2536 9 месяцев назад
Thank you. Very informative. When you blew out the line, you didn't put much air volume through. How do you handle buildup below the trap?
@Redspeciality
@Redspeciality Год назад
I used a shop vac on the outlet side, cleaned the blockage right out!
@gaylefriedman3773
@gaylefriedman3773 2 года назад
Thank You for necessary advice when it comes to cleaning away algae from A/C line. This only happens when you don't use your A/C Unit during Colder Months. I add water along mixed with bleach. I was told not to use bleach, vinegar only. I used this vinegar idea, and it caused the switch to overflow. There's so many voices, after a while who to believe? I find maintenance is getting overpriced. Maybe I'll learn to be a maintenance woman. I do it all. I just didn't clean coils, or install Units. I do the rest. Thank You. If you have any other Excellent Suggestions, do tell.
@Moondoggy1941
@Moondoggy1941 Год назад
Have fish aquariums and no one says use Vinegar to clear up algae, I would use bleach. Do it after the season on the last day. Algae does not grow where there is no light.
@markwilson7643
@markwilson7643 3 года назад
I tried a sealed hose vacuum at the outside drain for 20 minutes without resolve. Then tried from the other direction with your idea of taping a hose and it worked perfectly. Clear in 3 seconds. Used water instead of air compressor. Ran for 5 minutes to completely clean. Thx
@ronreyes9910
@ronreyes9910 3 года назад
If you have a shop vac, set it up for water and apply vacuum to the outside drain point.
@charlessaco4495
@charlessaco4495 5 лет назад
Thanks you for this wonderful video. What pipes do you recommend for installing the condensate lines, 3/4" or 1/2"? Thanks.
@acservicetechchannel
@acservicetechchannel 5 лет назад
Usually 3/4 is connected to your evaporator coil drain and 1/2" is connected to the furnace drain but you could make that bigger if needed. If it is light commercial and a large unit then 1" would come off the drain, thanks
@vieuxacadian9455
@vieuxacadian9455 3 года назад
replace the 90 with a T and that T with a 4 way cross . put threaded plugs on them and viola . fast multi point maint /service access . take a small flexible pvc tube , adapt it to fit a portable wet vac hose and viola , vacuum the trap then recharge it .
@toneblair
@toneblair 6 лет назад
Great video. If there is a long drain, would that amount of time be sufficient to clean it out? Or would you have to blow it out longer?
@acservicetechchannel
@acservicetechchannel 6 лет назад
The more water that you put into the drain before blowing it out the better. This was a shorter drain. Also if it is pitched correctly then typically there wont be a problem with clogging in the middle, thanks
@kevinmccool3719
@kevinmccool3719 3 года назад
I diluted a little bleach in water and blew the line several times on mine. Seems to help clean it out better for longer periods.
@DJ-Art-Morris
@DJ-Art-Morris 19 дней назад
Where my p trap comes up there’s no cap and it’s just cold air blowing out. I’ve read mixed things online about this. Can you please answer if it should be capped?
@chrisscinto889
@chrisscinto889 5 лет назад
I just add unions before and after the trap, if I have the room. If I don't have the room I'll make the room for 2. Once that's in place all you have to do every year is undo the unions and flush the trap out, after that put it back together and pour a liter of water into the pan with a small amount of simple green. The simple green mixture will then sit in the pipe and eat away any gunk if there is any in there. Also I forgot to mention I use hot water to clean the drain. I find that blowing out drains only pushes things down the line, especially with a lot of turns and bends. I like to make a process out of cleaning the drain because it's more worth taking the time then paying for a ceiling and sometimes more. Do you think I have a good process going on?
@vovobillinbrazil
@vovobillinbrazil 2 года назад
Craig. My Trane was installed in March of 2003. The installer never put in a P Trap. However. My condensate line leaves the Air Handler, makes a 90 to the right, then a 90 down to a line that runs below the slab. Then makes a 90 and heads west (under the slab) about 15 feet where it comes up above grade and goose necks. I have rarely had any issues. Should there still be a P Trap?
@jtra1122
@jtra1122 Год назад
Hi, a question for ya. I haven't found it being discussed on the net and just thought throw this out here since we're talking about similar topic -- condensation line. I notice that there're cold air blowing out of the AC drain condensation line in the attic. The air is cool up in the attic when AC is running. Don't think it should do that under normal circumstances right? The doors & air ducts are completely sealed thus I have no way to diagnose it unless I slice open the seal & tapes. Any suggestions are greatly appreciated? thnx...
@jimhoran5445
@jimhoran5445 3 года назад
Miami Dade county requires a 2 inch drain line now! From the floor to the outside! Going in and going out is reduced down to three-quarter pipe
@doeboy319
@doeboy319 10 месяцев назад
My main drain line is clogged. Could I use a shop vac to suck out the debris on the main line without damaging anything?
@LC-ns4ji
@LC-ns4ji 2 года назад
Vacuum on 1 end and flush with water other end, job done
@thomasjacques5286
@thomasjacques5286 2 года назад
I bought a drain gun with CO2 cartridges. My HVAC line is about 10 feet long from the side of the unit to my basement floor drain. Plus the builder installed a clear plastic trap that is easily removed. So I can see any debris in the trap.
@christyholguin8595
@christyholguin8595 Год назад
Where did you get the CO2 cartridges? Do you need a license for that?
@Stuart68505
@Stuart68505 3 года назад
There is a need to vent the drain pipe to help it drain properly. When the evaporator blower creates significant vacuum it can stop the water from flowing down the drain if there is no vent to break the vacuum force against the drain.
@joleaiperlis5347
@joleaiperlis5347 Год назад
Does the vent need to be before ptrap or after, or does it mater at all??
@dukedesolo5669
@dukedesolo5669 10 месяцев назад
The vent is after the trap.
@funkycowboy
@funkycowboy 9 дней назад
How do you clean from the inside of the unit? Right of the T? Can you get in there to clean it?
@andrewpolasek5524
@andrewpolasek5524 Год назад
I also use the shop vac from the outside method and let it run for several minutes. The extended run time removes more stuck-on grunge inside the pipe than a quick blast. But if you do use the blast-out method, make sure your customer is not standing anywhere near the exit end of the condensate line (unless you want an ex-customer!)
@bradrobinson8326
@bradrobinson8326 Год назад
Question for you: My condensate line exits in a upstairs bathroom sink. Does that probably mean there's no way for me to do the outside shop vac method? Or is there likely another drain line exiting outside?
@andrewpolasek5524
@andrewpolasek5524 Год назад
@@bradrobinson8326 If the drain line is accessible in the bathroom, you can hook up the shop vac there and vacuum out the line.
@Orrphan
@Orrphan 10 месяцев назад
The shop vac will clear initial blockage, but won’t remove stuck on stuff off walls of pvc. Always good to shoot water afterwards multiple times up line and let gravity drain.
@tylermccall1600
@tylermccall1600 2 года назад
best way to clear a drain line is to have the p trap be removeable hence dont glue your trap into the threaded adaptor for the coil pipe seal works just fine and makes it removeable and cleanable without having to cut and re do not to mention doing it this way works on most set ups
@rgnldwllms
@rgnldwllms 4 года назад
Thanks.
@acservicetechchannel
@acservicetechchannel 4 года назад
Thans Reginald!
@tjyork1983ia1
@tjyork1983ia1 27 дней назад
What size vinyl tubing do you suggest?
@skylamorrison6973
@skylamorrison6973 3 года назад
Hey I live in Florida I have a water to air ac. The water supply going in is fine but the return is low what is the best way to clean it out?
@electricboogie709
@electricboogie709 6 лет назад
Thank you! On commercial, I usually have to open it up on both interior and exterior. Gets nasty.
@acservicetechchannel
@acservicetechchannel 6 лет назад
Got ya, thanks!
@runningcoyote3897
@runningcoyote3897 5 лет назад
do you prefer to use copper sulfate or condensate tablets.
@robwebnoid5763
@robwebnoid5763 3 года назад
Hello, I need help on this too. For the first time, because of summer heat, there an inch of water on the water pan underneath the air handler which is sitting on a wooden pallet which then sits inside the pan. Because of that, I'm afraid the water is going to ruin the pallet. This is how the builders constructed it. It's upstairs. I had to use a small sump pump. There are 2 pipes going to the outside where they are placed near the eaves of roof. One pipe comes out of handler with the trap & cap as shown here in video. The other pipe seems to be a drain for the water pan, except I don't see it draining the pan. So should I try the mouth blowing technique shown here? I could send a photo of it for clarity. We have used a service before but it was to change the blower motor & that was a hefty $800, even after he helped with a discount. I don't want to pay for service to clean out condensate pipe because it will probably be at least $75-100 just for the visit. The pan is getting water again, so need to sump pump again. I assume the pan drain pipe is also somewhat clogged too. Please help.
@dianarego1799
@dianarego1799 2 года назад
Can you link the size of the vinyl tubbing pls
@carefulconsumer8682
@carefulconsumer8682 3 года назад
Should you see the water/vinegar drip out of the condensate pipe outside after you do this?My landlord poured vinegar down that tube and cleaned it out that way. There was no cap on my tubes.
@CarolCityCane305
@CarolCityCane305 Год назад
What do you do when your attic is super hot in Florida and your ac unit is up there the refridant pipes have covers on them but the cool pipe and the heat are causing it to drip on my ceiling what do I do
@mizzoutx59
@mizzoutx59 4 года назад
Cleared the line where the trap was. Didn't seem to be the problem. Water is dripping from where the unit meets the pipe connection into the pan. Is there a way to clean the area back to the unit to see if it's clogged at the unit's base?
@jamescc2010
@jamescc2010 3 года назад
Refrigerant Filled Tubing is making crackling noise inside in my garage next to HVAC unit. We can also hear crackling noise outside next to compressor unit. What is the cause? It constantly making noise regardless if AC is not on/off or furnace heater is on/off. Very strange. Maybe coolant in the pipes or moisture, metal contracting due to cool air?
@AmbreeQuijada
@AmbreeQuijada Год назад
What is that cap for? I've noticed my Lennox HVAC has to pipes that point up like that without a cap.
@johngranato2673
@johngranato2673 3 года назад
I spliced in a hose barb and use the garden house to blow out the line. After flushing the line, I pour in some Clorox. If you don't fill int "P" trap, the dripping water will refill it.
@iwinzeazy
@iwinzeazy 5 лет назад
I hooked up my vacuum hose over the trap for 2 minutes and no more leaking, I will do this weekly for preventive maintenance and also poured bleach after clearing it😎
@acservicetechchannel
@acservicetechchannel 5 лет назад
Yes, if you are having an ongoing problem then the tube may not be pitched correctly at least 1/4" pitch downward going away from the unit, thanks!
@tomh9470
@tomh9470 3 года назад
iwinzeazy Avoid bleach. Use high acidity white vinegar instead. The reason is bleach fumes will destroy the anti-corrosive coating on the heat exchange coil inside the air handler.
@ldd7060
@ldd7060 20 дней назад
How do you get inside the other line? Where the pvc pipe attaches to the coil?
@samson23
@samson23 14 дней назад
Do you need to turn off the AC in order to do this maintenance?
@Mitch2294
@Mitch2294 2 года назад
From years of experience just take a couple 3/4 couplings cut the trap out and wash it out with the garden hose saves a call back and insures its good to go vs pushing slime around also pour a good amount of water down the line to wash out the rest of the gunk. Just my recommendation clearing condensation lines is a low price item and you make even less money coming back to blow it out twice.
@rudyespinoza6781
@rudyespinoza6781 4 года назад
Thank you for the training
@acservicetechchannel
@acservicetechchannel 4 года назад
Any time!
@gonzo1124
@gonzo1124 3 года назад
I recently came back to a completely clogged drain on my A/C. Tried the shop vacuum, water from the hose, etc., no go. The only thing that worked was the air compressor. Nasty crap came out all over and it had been professionally cleaned 5 months ago! Compressed air is the best, not sure about blowing air into a tube, unless it’s pretty clean already or as a preventive measure.
@jsparlin1
@jsparlin1 3 года назад
they have chlorine tablets to keep mold under control
@josebenedico7379
@josebenedico7379 3 года назад
What's the best product or liquid to clean the coils
@iwiredit
@iwiredit 5 лет назад
I installed the Cost Gard condensate drain seal on my unit which eliminates the Trap all together. So no more water sitting in a trap I have a blow through system and will never have to clean out a trap. Best alternative on the market I even did a video on it. Titled: How to never clean your AC condensate drain line.
@acservicetechchannel
@acservicetechchannel 5 лет назад
Great Job Jonathan!
@mariar3424
@mariar3424 3 года назад
Hello! Thanks for the tip. I live in the 4th floor of a building, so the line is pretty long. Would this work as well? Should I do some extra?
@kevinmccool3719
@kevinmccool3719 3 года назад
Do this and ad some bleach
@mariar3424
@mariar3424 3 года назад
@@kevinmccool3719 Thank you!
@lynettefields1027
@lynettefields1027 2 года назад
Mine is horizontal rather than vertical so what's the best way to use the vinegar?
@andusgarza497
@andusgarza497 3 года назад
at my girlfriends place. there is no cleanout but its clogged im sure! because its leaking. so i will install one. theres another hole next to it open though. is that a second drainage? because i see water flowing.
@elasiaapb8645
@elasiaapb8645 10 месяцев назад
If i have problems with a drain i like to install a jones valve, makes things easier
@mike32oo
@mike32oo 6 лет назад
One of the problems I've found just blowing out the p-trap is you risk pushing the debris further inside the drain without removing it. The ezt clear p-trap is by far the cleanest and easiest way to service a p-trap.
@acservicetechchannel
@acservicetechchannel 6 лет назад
U-traps are nice. I actually linked the one you are referring to in the comment and description sections. It is weird, its one of those things. I found that customers with the U-traps that I don't have a service agreement have more problems with clogs when they forget to clean them out than p-traps but yes U-traps allow you to vac it, brush it, or blow the debris out, thanks
@Scorpio-tn4vy
@Scorpio-tn4vy 2 года назад
It breaks it up and allows it to flow through.
@lovelylouro
@lovelylouro 5 лет назад
Hi, Texas mom here, my unit does not have a cap and there is water in there and I can see black along the inside of the pvc but no globs in the water and no leaking, no problems, or anything. I maintenance my machine professionally once a year before putting on my heater, but I skipped this year. Do I need to do this? I've heard the tech guys saying to pour bleach down in there and then hot water, but my Lennox is about 30 years old and came with the house when I bought it 4 years ago and I'm afraid to do anything to it. But it's insured and whenever it goes out, we're ready to replace it, but it's still cold-cold in our Texas Summer heat, and Warm-warm right now in our baby Winters, so I don't mess with it. Haha! Any suggestions for me, besides prayer! LOL.
@acservicetechchannel
@acservicetechchannel 5 лет назад
Did you check this video out yet- ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-guf3TESb3V0.html
@teslamr7333
@teslamr7333 3 года назад
I live in a condo and my a/c line has been getting clogged a lot, already 3 times in the last three months. It seems like it happens when it rains a lot. Do you think the main line where it drains could be clogged?
@kevinmccool3719
@kevinmccool3719 3 года назад
It's full of algae and dirty gunk. Blast air in it, some bleach and hot water several times.
@johncote2776
@johncote2776 6 лет назад
Never thought to add water before cleaning. I've flushed out really dirty ones with a vacuum cleaner. I've always wondered if a vinegar/water solution would mess with the glue/primer?
@acservicetechchannel
@acservicetechchannel 6 лет назад
Yeah, its that hydraulic affect. Some hydrex tablets in the pan before it gets to the trap can help for the future, thanks Blue Collar!
@raindogs451
@raindogs451 Год назад
If, instead of a first 90, a T was installed with a female adapter and 3/4 black plug, you now have a plug front and center to remove and clean the evap outlet. I use black because PVC plugs warp and cross thread. You can---for just a couple dollars more----install a deeper preformed clear trap that is outstanding and comes with a brush attached. That first T still acts like a regular 90 but now with a forward cleanout.
@AGRANT716
@AGRANT716 4 года назад
I used a shop vac to clear my lines, now the other line with sensor is overflowing. Is there a valve somewhere that closed because of the vacuum
@henryheckler8917
@henryheckler8917 3 года назад
lol negative pressure from the unit. prime your traps after you clear.
@deepb249
@deepb249 2 года назад
My condensation pipe outside house is dripping water. It stops drips may be 2 gallons then stops sometimes for a day or 2 and repeats. What is going on here? What can I do to fix this?
@Pilot_the_Dune
@Pilot_the_Dune 2 года назад
I ran a cutoff valve before my trap so I could run 100 psi through the line with no back feed issues. Blows anything out the line.
@kidbowjb
@kidbowjb 6 лет назад
I have a question if I may. Nothing is clogged but there is water dripping from far right of air handler in the plastic safety tray. Any idea why this would be happening
@acservicetechchannel
@acservicetechchannel 6 лет назад
The air handler could be sitting out of level, the pan could be cracked, or the pan outlet could be clogged. Also the refrigerant charge could be low which could be making the coil freezing and then thawing when off, thanks
@TheDylonias
@TheDylonias 3 года назад
Is that the outside unit or the inside unit
@thebigmachine98
@thebigmachine98 4 года назад
Hello, can you still put water if the hole to put the water in is not directly on that curved location? I have a pipe where you can put water in, but it is not directly above the curved area and is a little to the side
@thebigmachine98
@thebigmachine98 4 года назад
So basically the AC piping was designed Like to the left you have the pipe going straight down where the water goes You go more right and you see the hole where you put the warm water Go further right and you see the curved piping where the water usually gets clugged Go further right and that's where the AC system is mounted
@JacobLeebuddha87
@JacobLeebuddha87 6 лет назад
Thank you for video. Anyone know what is name of the pipe part which connect with the air conditioner ? It looks like its size and thread are standard. Anyone know where I can buy it ?
@acservicetechchannel
@acservicetechchannel 6 лет назад
3/4 pvc male adapter, home depot, lowes, hvac supply house, thanks
@JacobLeebuddha87
@JacobLeebuddha87 6 лет назад
Thank you very much. It helps a lot!
@charleslauter5035
@charleslauter5035 3 года назад
I have been doing this for years except that I use White Vinegar instead of water. Vinegar kills the stuff that grows in the drain pipe.
Далее
HVAC Contractors Hate Me For Sharing This Secret
10:21
Просмотров 717 тыс.
How to Clean Out a Condensate Pump
5:27
Просмотров 147 тыс.
Cleaning AC Drain Line (Routinely) Using Vinegar
2:54
Просмотров 531 тыс.
NEW HVAC Maintenance  - Flushing the Condensate Line
1:46
HVAC DIY Maintenance - Float Switch Explained
10:05
Просмотров 250 тыс.
AC Drain Clogged P Trap last place I looked
15:09
Просмотров 50 тыс.