@JoeLinux2000
@JoeLinux2000 5 лет назад
Recently I've been looking at a lot of Furnace description and diagnostic videos. This is absolutely one of the best.
@3videnc3
@3videnc3 5 лет назад
I agree!
@oscarmosca1234
@oscarmosca1234 3 года назад
this guy knows how to teach.
@jaykesapalaran5434
@jaykesapalaran5434 Год назад
Thank you for sharing your knowledge,
@jman0870
@jman0870 5 лет назад
A run capacitor's job isn't to store power like a battery or give more power to the motor. In fact, it's very unlikely that little run capacitor will store energy for more than a second or two after the disconnect is turned off. Single phase inductive loads generally push your current and voltage out of phase with each other. This is true for all PSC motors. The capacitance of the capacitor counter acts the phase shift between your current and voltage caused by inductance and gets them back in line with each other. Without the capacitor the motor will pull too much current, create a ton of heat, possibly fail to start, and cause the motor to cycle on internal overload leading to a very short life for the bearings and windings of the motor.
@izzymoney85
@izzymoney85 5 лет назад
Thanks Ryan very informed on 80% to 90% furnaces and ECM models keep up the good work I would like to see videos on ECM models and troubleshooting them to which I would deeply appreciate Thanks sincerely Esmar
@TECTubefilms
@TECTubefilms 5 лет назад
There are several ECM Troublshooting videos in our Motor playlist. They were done by Genteq. ru-vid.com/group/PLoR_O4JRNc26An0QF_ygah4LX72Vj8URd
@brando8024
@brando8024 3 года назад
Tremendous information. Thanks. Well done!
@tntheatingandairllc
@tntheatingandairllc 4 года назад
Great video
@andresgabrielaguilera763
@andresgabrielaguilera763 3 года назад
this was super helpful, thanks a lot!
@emmywelsh6374
@emmywelsh6374 6 лет назад
found your channel today, so happy with your content. thanks!!
@syedbasheer3909
@syedbasheer3909 3 года назад
Thank you very much sir
@alexc4524
@alexc4524 5 лет назад
great video thanks
@Tracks777
@Tracks777 7 лет назад
I look forward to more videos.Keep it up!
@seshachary5580
@seshachary5580 6 лет назад
Very educative thank you regards
@PBS-nm1uu
@PBS-nm1uu 6 лет назад
thanks for all info do you have any trouble shooting videos??
@TECTubefilms
@TECTubefilms 6 лет назад
For furnaces? Check out our "playlists" and go to the one for furnaces. There are several for motor troubleshooting, airflow, etc., and we are working on more.
@gromero1414
@gromero1414 6 лет назад
Is it possible for those tubes in the secondary heat exchanger to get clogged or crack. And what would cause that? Thanks. Awesome video btw
@TECTubefilms
@TECTubefilms 6 лет назад
They could get clogged. If they are clogged on the inside, it could be due to incomplete combustion, debris in your combustion air, or other factors. If they are clogged on the outside (the fins), it would be due to your return air being dirty (i.e., lack of filtration)..
@TECTubefilms
@TECTubefilms 6 лет назад
Cracks are more likely to occur in the primary heat exchanger where the temps are the hottest. This is usually due to too high of a gas pressure or too little airflow. Cracks in the secondary would be uncommon.
@DaveIngle1
@DaveIngle1 3 года назад
Do you gas analyzers to test for proper operation and if so what is normal? My service tech says it's the only way to prove correct operation. He provided me the numbers and said I needed additional service. Thanks!
@TECTubefilms
@TECTubefilms 3 года назад
Yes, you can use a combustion analyzer on a furnace, just like you can use it on a boiler. That may be a good subject for our next video...
@Broabeluciano
@Broabeluciano 4 года назад
You sure know your stuff...
@MRMilade
@MRMilade 4 года назад
where is part 2?
@TECTubefilms
@TECTubefilms 4 года назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-KOZeiT3q0-s.html
@captainamerica6521
@captainamerica6521 4 года назад
do the condensed air gas furnace made by carrier pull all the poluution and pollen and molds into home i tested my drain tube water coming out its positive for toxic molds and noticed when gas is off it pumps cold air through vents when fan running
@TECTubefilms
@TECTubefilms 4 года назад
All brands of condensing furnaces work the same. They can be installed to pull combustion air from outside (2-pipe) or from inside the home (1-pipe). However, when combustion air is pulled from outside (where pollen comes from), it just runs through the heat exchanger and then back out the exhaust. It does not mix with the indoor home air.
@TECTubefilms
@TECTubefilms 4 года назад
Some homes, in addition to combustion air, also have intakes for fresh outdoor air. In those cases, pollen can enter the home, so good filtration is recommend.
@TECTubefilms
@TECTubefilms 4 года назад
Condensate water, for all brands of furnaces, has an acidic nature and products of combustion. It should not have mold, though. Perhaps mold is growing in your condensate pan on your evaporator and it shares a drain with your furnace. Or perhaps mold is growing in your furnace condensate trap and it needs to be cleaned.
@TECTubefilms
@TECTubefilms 4 года назад
If you have your thermostat fan setting in the "on" position (or you have a ventilation intake system also controlling the fan), then the fan will be running when the heat is off. This is normal. If the air is cold, you may have leaky ductwork in an unconditioned space sucking the cold air in.
@stephfong4577
@stephfong4577 3 года назад
Why does no one make a video on an electric furnace?
@TECTubefilms
@TECTubefilms 3 года назад
Try searching for "air handler" or "fan coil," instead. In many parts of the country, including Chicago where we are from, the term "electric furnace" is not used.
@JustPlumDucky
@JustPlumDucky 6 лет назад
What kind of camera are you using?
@TECTubefilms
@TECTubefilms 6 лет назад
twentysixmiles John Paul Mungo Photography uses Sony ax53 with a rode go mic... I bought that one because the optical image stabilization in phenomenal. And it was on sale. Ha
@PBS-nm1uu
@PBS-nm1uu 6 лет назад
is the 24v ac or dc ??
@TECTubefilms
@TECTubefilms 6 лет назад
24 vac
@captainamerica6521
@captainamerica6521 4 года назад
single stage carriers suck people! junk class action lawsuits for years for carrier knowinly making crap parts
@TECTubefilms
@TECTubefilms 4 года назад
There was one class action lawsuit that we are aware of regarding Carrier furnaces. They stopped using that style of heat exchanger in 2012. They also have been replacing those failed heat exchangers and/or giving the consumer an option to change to a different style furnace. Manufacturing warranty failures happen for all brands and all industries. We measure the brand based, in part, on how well they respond and react to any issue that happens.
Далее
Furnace Troubleshooting Step by Step with Multi Meter.
26:33
А ВЫ УМЕЕТЕ ПЛАВАТЬ?? #shorts
00:21
Просмотров 840 тыс.
Gas Furnace Ignition Sequence
6:17
Просмотров 52 тыс.
Top 5 Furnace Problems and How to Fix Them
20:11
Просмотров 1,4 млн
Watching A Furnace Run With A Cracked Heat Exchanger
6:36
Mastering Gas Heat in 10 Minutes
32:32
Просмотров 20 тыс.
Setting Gas Pressure on a Modulating Gas Furnace
19:15
Sequence of operation
19:05
Просмотров 474 тыс.
Furnace Troubleshooting - Top 10 Furnace Problems
43:03
Yearly Furnace Cleaning And Maintenance Pro Tips
8:56
Просмотров 959 тыс.
Gas Furnace Turning Off? Here's What Might Be Happening
15:56