How to Configure an S7-300 Redundant PLC _ PART 2 

RealPars
Подписаться 1,1 млн
Просмотров 98 тыс.
50% 1

Опубликовано:

 

21 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 105   
@mortedeus1992
@mortedeus1992 6 лет назад
Thank you Real Pars your presentation was very clear and easilly understandable.
@realpars
@realpars 6 лет назад
You are very welcome! Thanks for watching.
@the2statescouple788
@the2statescouple788 7 лет назад
Such a good presentation on siemens plc i have seen so far. Good job friend. Can you upload a small example of program using redundancy technique. Thanks in advance.
@derina.maleek9408
@derina.maleek9408 5 лет назад
Your videos make me better in plc programming your videos are best in RU-vid I wish you best and thank you I am working in that field just because that knowlege you give me stay like that please and post more video. And I love you again
@realpars
@realpars 5 лет назад
Many thanks for your positive feedback! We are very happy to hear that. Happy learning!
@Oluwasedago
@Oluwasedago 9 лет назад
I really enjoy your posts and they give me a better understanding to PLCs. Can you please create a programming video using S7 for newbies like me. I have seen the Mixer programming and its good. Thanks again!
@AbdullahAhmed-vj2vi
@AbdullahAhmed-vj2vi 3 года назад
You deserve a million likes
@realpars
@realpars 3 года назад
Thank you, Abdullah!
@Hedger7541
@Hedger7541 8 лет назад
This is very helpful. The presentation was excellent.
@nagulavanchasubrahmanyam8430
@nagulavanchasubrahmanyam8430 4 года назад
thank you Realpars, the same way I need DCS information
@tanzilabedi9094
@tanzilabedi9094 8 лет назад
who are the two idiots disliking this video?? this series is such nice and helpful video series...thnk you so much...keep uploading
@realpars
@realpars 8 лет назад
LOL.... great to hear you enjoyed the video Tanzil!
@tanzilabedi9094
@tanzilabedi9094 8 лет назад
+RealPars lol... thanks for your reply...can you upload Siemens programming videos also?
@realpars
@realpars 8 лет назад
Welcome! We already have a few videos on that. Check out the links below if you have not already watch them: PLC Programming Tutorial for Beginners_ Part 1 ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-y2eWdLk0-Ho.html PLC Programming Tutorial for Beginners_ Part 2 ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-nYr8Q21nG0k.html
@ashishdeshmukh5220
@ashishdeshmukh5220 9 лет назад
I am very thankful to you. its very good explanation ,understanding the system is very simple.if possible please take more programming examples similar to mixer in which you can cover all functions of S7-300 (Counters,timers etc.) thanks.
@h20no63
@h20no63 7 лет назад
more on sf, bf, Olm's, terminating resistors on profibus, more on siemens in general great videos.
@ziad_ma4049
@ziad_ma4049 6 месяцев назад
Thank you very much for the information you provide, however I have a question, I couldn't see the point of doing such a system, I mean what if a failure happened to the io cards, and that's more common than failures in cpus, then both cpus with be in sf mode and the system will go down, I have faced such a problem before in a cement factory.
@amandeepsinghdhani2045
@amandeepsinghdhani2045 5 лет назад
You're great Sir..best explanation
@realpars
@realpars 5 лет назад
Thank you for your positive feedback!
@GameZone25253
@GameZone25253 4 года назад
Awesome 3D graphics helpful video.
@realpars
@realpars 4 года назад
Great to receive your feedback, Akhtar! Thanks for sharing.
@javierferrer4634
@javierferrer4634 6 лет назад
Thank you for the video, it’s very good !
@juntrang9871
@juntrang9871 9 лет назад
It's very helpful. Thank so much sir
@realpars
@realpars 9 лет назад
+Jun Trang You're very welcome!
@jackbaemer6879
@jackbaemer6879 9 лет назад
thank you very much sir......
@erdemfrat4834
@erdemfrat4834 4 года назад
Great job! I know working principle is the same but, Are there any differences between s7-1500 R/H system and s7-300 ?
@realpars
@realpars 4 года назад
There are a number of differences, including performance and form factor, but the underlying programming and interface concepts are nearly the same. To construct the same redundant setup as in the video except for an S7-1500R, you would only need to connect the CPUs via redundant ProfiNet cables (Profinet ring). For an S7-1500H, there is a synchronization module at each CPU connected by fiber optic cables. For the S7-1500, the redundancy is easier to install and configure, requires less hardware, and has much better performance.
@irajnoormanesh9805
@irajnoormanesh9805 8 лет назад
thank you very much
@realpars
@realpars 8 лет назад
+Iraj Noormanesh Thanks for watching!
@naderchinichian
@naderchinichian 8 лет назад
hi can you make video for software redundancy?
@mouadkech8279
@mouadkech8279 5 лет назад
i think there isn't a redundancy software because this redundancy is configured by hardware configuration
@junedmansuri6319
@junedmansuri6319 9 лет назад
very nice.. keep it
@huynguyenvan1909
@huynguyenvan1909 8 лет назад
Thank you so much
@ioannistsikriteas3807
@ioannistsikriteas3807 7 лет назад
Hi, I wanted to ask if the redundancy is possible using ethernet protocol and not a profibus one. I think that it is possible even if i don't know how it is done....and it is more easy at programming it
@realpars
@realpars 7 лет назад
For S7-300, you should use Profibus for having the CPUs working as a redundant system. But for S7-400 you can use Ethernet as well.
@Rupeshkumar-py1df
@Rupeshkumar-py1df 4 года назад
Hi dear I watched your every videos this is very helpful for me thank you. Dear plz make some videos for plc hardware wiring and it's control using software ❤️
@realpars
@realpars 4 года назад
Hi Rupesh! Thanks for your comment and your suggestion. I will pass this on to our course developers! Thanks for sharing and happy learning!
@sankhahalder5407
@sankhahalder5407 9 лет назад
very good............
@delvinmata5653
@delvinmata5653 2 года назад
Hello friends, what is the possibility that with the equipment you mentioned in this video we can implement a ring type network to have redundancy in case of a break in the Profibus cable that communicates the PLC with the ET200?
@realpars
@realpars 2 года назад
You will need to use CPU's and communications modules that support MRP (Media Redundancy Protocol) and have 2 ProfiNet ports (not the same as Profibus DP). I know the S7-1500 CPU and ET200SP remote I/O offer this feature. Some models of the S7-300 do, but you would have to use an ET200MP remote I/O system to get the Profinet connectivity.
@wenzhang7912
@wenzhang7912 4 года назад
I really like these!!!great!! Like SIEMENS!!
@realpars
@realpars 4 года назад
Thanks a lot!
@Nerrvas
@Nerrvas 6 лет назад
Hi, thanks for video. One question, after failure of master, slave kick in. After error was fixed does master overtake control from slave or it will stay as slave till new master fails ? Does one of them have higher priority than other or its manually set witch will be master by operator?
@realpars
@realpars 6 лет назад
Hi, you're very welcome. In this redundant system, when PLC A fails, PLC B is going to take over the control of the system and stays active regardless of the error being fixed for PLC A or not. None of the PLCs have a higher priority over the other. I hope this helps.
@delvinmata5653
@delvinmata5653 2 года назад
Thank you very much for the information, it is perfectly understood, now I have a question. What would happen if one of the ET 200 fails? Or, what would happen if the profibus cable that communicates one of the PLCs with one of the ET 200 suffers a fault? Would the backup ET 200 continue to send the required information transparently?
@realpars
@realpars 2 года назад
Yes, it would failover to the backup if the primary ET200 faulted or the cable was damaged. If the backup fails, the primary will continue to operate. In either failure case, diagnostic information will be available., indicating that the fault has occurred.
@delvinmata5653
@delvinmata5653 2 года назад
@@realpars Thank you very much for the information
@kamelhamdi2219
@kamelhamdi2219 8 лет назад
thanck you
@bolaheya6220
@bolaheya6220 5 лет назад
Big thumb up great content
@realpars
@realpars 5 лет назад
Thanks a lot, Boulaheya!
@abubkeralsiddig9146
@abubkeralsiddig9146 6 лет назад
thanks a lot for showing these important videos I have important question and I do really waiting for your answer what if PLC B go down ????? because I have a redundanc system with s7 400H and I but the reserve PLC on stop mode so what happened! all the system go down 😅
@CHIRANJIT79
@CHIRANJIT79 4 года назад
What is the difference between this configuration and hot redundent system ?
@realpars
@realpars 4 года назад
Hi Chiranjit, Thanks for your comment! That makes for a great topic suggestion, I will forward this to our course developers.
@faizanmoon8718
@faizanmoon8718 8 месяцев назад
Hello sir, I am facing node issues. We have Siemens S7-400 PLC. CPU 416 connected with multiple nodes. One of the node missed for short interval of time (200ms to 300ms). These node are addressed in diagnostic buffer. Kindly suggest what steps to take to resolve the issue
@realpars
@realpars 8 месяцев назад
Thank you for reaching out regarding the node issues you're experiencing with your Siemens S7-400 PLC. Addressing node communication problems can be complex, as they can be influenced by various factors. Given the complexity of node communication issues and the specific configuration of your PLC system, it would be best to reach out to the vendor of your Siemens S7-400 PLC for further assistance. They can provide specialized expertise and diagnostic tools to help identify and resolve the issue effectively.
@faizanmoon8718
@faizanmoon8718 8 месяцев назад
@@realpars Thank you for your reply. We are using S7-400 PLC CPU 412-2 DP (6ES7 412-2XG00-0AB0) We have connected multiple nodes through this CPU of S7-300 (IM 153-1 6ES7 153-1AA03-0XB0) Some of the nodes are disconnected after every 5 to 6 hrs for 200ms. We found this on diagnostic buffer of simatic Manager.
@Thippesh2016
@Thippesh2016 Год назад
I am very thank you❤🌹🙏
@realpars
@realpars Год назад
Always welcome!
@mohamadrezabahrizadeh6262
@mohamadrezabahrizadeh6262 5 лет назад
Hi What is the repeater for? Can we omit it and tie its inputs and outputs together, as we have in the software (hardware configuration)?
@realpars
@realpars 5 лет назад
Hi Mohammadreza, It is possible to connect up to 126 devices, both masters and slaves in a Profibus DP network. However, to operate the network with this number of bus stations, the bus must be divided into individual segments. The segments then must be connected by repeaters, devices capable of processing the network signal and handle disturbances or noises in a way to reject them and re-create a favorable situation to the physical layer. No, it is not possible to tie the inputs and outputs of an RS485 Profibus DP together at all! Thanks
@edevalddrovetto3763
@edevalddrovetto3763 3 года назад
Great video, it's possible to do a redundant system with 2 different CPUs with the same IO configuration? In example: one S7-315 and one S7-312, respecting memory and processing times by the slowlier CPU capacity?
@realpars
@realpars 3 года назад
I believe it is, as long as each CPU has the same I/O hardware configuration employed. Redundancy in an S7-300 system is software redundancy and is driven by program blocks configured in the CPUs. Normally, the CPUs are the same model, but as long as the same program can be executed in each of the CPUs you have listed, the redundancy approach should be possible.
@sachinmahindrakar2170
@sachinmahindrakar2170 5 лет назад
Is the switchover bumpless? If no then what is the switchover time.
@realpars
@realpars 5 лет назад
The S7-300 family of processors uses a strategy called "software redundancy". According to the Siemens Software Redundancy manual (A5E02171565-02), the transfer from primary to secondary takes 1 - 2 OB cycles (typically 30 - 200ms depending on program complexity). When a fault is detected, the outputs are frozen and the Process I/O Image (PIO) is transferred from the primary to the secondary. This is what takes 1 - 2 OB cycles.
@DracMastah
@DracMastah 4 года назад
Do you need to configure anything on the CPUs so they know they are working en redundancy mode and which one is the master? or do they seemingly detect they are redundant...? thanks!
@realpars
@realpars 4 года назад
With S7-300 redundancy, you need to configure the hardware configuration for redundancy as add programming via specific blocks (SWR_START, etc.) and interrupt blocks to make the switchover efficient and reliable
@hardysetiawan4703
@hardysetiawan4703 6 лет назад
thank you, can you make a sample of redundant program?
@realpars
@realpars 6 лет назад
You're welcome! We'll consider your suggestion for creating new videos.
@awjoykantibonik4017
@awjoykantibonik4017 6 лет назад
What is SCALANCE X208? Is this also use for the HMI like repeaters?
@realpars
@realpars 6 лет назад
Hi There, it's a Siemens SCALANCE X208 Managed Switch ‑ 8 Ethernet Ports. The switches are ideally suited for the design of Industrial Ethernet networks with 10/100 Mbit/s in line, star or ring structure. The integrated redundancy manager of the SCALANCE X-200 switches can be used to build redundant optical or electrical ring structures. The units feature extensive diagnostic options, such as PROFINET You can monitor field devices via HMI And PLCs. So in order to make a connection with them and reach your final desired movements, you can use this switch device to give orders constantly based on your power system plan. Hope this answers your questions.
@Rydklick
@Rydklick 9 лет назад
guyz, where will you connect your engineering station?... and... guyz, can you upload also about s7-200...
@uttamkhot3403
@uttamkhot3403 6 лет назад
Very useful vidio
@realpars
@realpars 6 лет назад
Thank you!
@swaminathan1248
@swaminathan1248 7 лет назад
can you explain about s7-200
@CHIRANJIT79
@CHIRANJIT79 4 года назад
If we can make a redundenency with normal CPU than what is more on H-CPU ?
@mdnzm31
@mdnzm31 3 года назад
1:38 "we have the same situation in Rack3",if rack2 and 3 both are same situation,then how do u conclude A is master?
@realpars
@realpars 3 года назад
Rack 2 and Rack 3 are connected to a redundant pair of PLCs, PLC A and PLC B. Racks 2 and 3 have 2 ET200M Link cards. The left-hand cards are connected to PLC A via a Profibus connection. The right-hand cards are connected to PLC B through a separate Profibus segment. When PLC A is the master, the left-hand Link cards are active; when PLC B is the master, the right-hand Link cards are active. At 1:38 in the video, the Active light on the left-hand Link cards are on, so PLC A is the active PLC in the redundant pair.
@llaease
@llaease 8 лет назад
I have read on Siemens forums that I/O redundancy for s7-300 cpus is not possible, but in this video it is possible, what does I/O redundancy mean exactly then?
@realpars
@realpars 8 лет назад
+AhmadWAyase Here there is one set of I/Os with two CPUs, meaning that you have the same I/Os but two CPUs. If for any reason the main CPU stops working the other one takes care of controlling the system.
@llaease
@llaease 8 лет назад
RealPars so here it is called I/O redundancy? if yes, why are they saying on the forums that I/O redundancy is not possible with 300 CPUs, and is it possible to do 300 CPUs redundancy using profinet and not MPI?
@TheGamaCom
@TheGamaCom 5 лет назад
fantastic
@realpars
@realpars 5 лет назад
Thank you!
@raguraman1238
@raguraman1238 3 года назад
Good
@abdessamadmoujoud5242
@abdessamadmoujoud5242 7 лет назад
Hi , i want to know how the CP 342.5 is connected to the CPU? because i have the same configuration as this video but with a CPU315-2PN/DP S7-300 and a CP342.5 and i dont know how to connect them together ?
@realpars
@realpars 7 лет назад
Hi there, the CPU is connected to the CP via Profibus network. You can do a Google search for CP342.5 manual for more details on how to do that.
@abdessamadmoujoud5242
@abdessamadmoujoud5242 7 лет назад
thank you but in the video this connection is not showen ?
@realpars
@realpars 7 лет назад
You're welcome! Have you watched the first part of this video. At the end of that video we talk about the network configuration in the software which I'm sure gives you a better idea on how to do that. You can watch the video here: ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-K3AXkW2Dp3M.html
@abdessamadmoujoud5242
@abdessamadmoujoud5242 7 лет назад
yes i watched it, you're talking about this part of video sorry i can't see the connection , thak you again
@abdessamadmoujoud5242
@abdessamadmoujoud5242 7 лет назад
sorry i can't post the screenshot here , so i sent it to you on facebook
@anonymoususer5959
@anonymoususer5959 5 лет назад
Could anyone please explain the difference between 300's soft redundancy and 400's hardware? Thanks.
@realpars
@realpars 5 лет назад
With software redundancy, two CPU's with the identical program are running at the same time. The master executes its program in it entirety. The standby program executes, but skips the fault-tolerant portion of the program (logic and setting of outputs). The master continuously updates the secondary's memory and PIO table. When a fault occurs, the secondary begins execution of the entire program and takes over as master. This may take a couple of cycle of the program to fully changeover. With hardware redundancy, two identical CPUs are connected to a redundancy module so that the synchronization of the data/memory spaces of the CPU's occurs through a high-speed fiber connection. This makes the synchronization of the CPU's much faster, and reduces the fail-over time when a fault occurs.
@anonymoususer5959
@anonymoususer5959 5 лет назад
@@realpars Thanks a lot. so the main disadvantage of soft redundancy is the swithover time?
@mnada72
@mnada72 4 года назад
In this configuration the redundancy is on the CPU level, but how to achieve redundancy on the I/O level ?
@realpars
@realpars 4 года назад
Thank you for the excellent question! To configure I/O redundancy, you will need to use an "H" series CPU, like the S7-400H. The manual for that CPU is here: cache.industry.siemens.com/dl/files/386/60458386/att_63953/v1/S7_400_h_en_en-US.pdf On the hardware side, you will need to read Chapter 13 of this manual to understand the concepts of "single-channel one-sided I/O" and "single-channel switched I/O". The use of specific IM interface modules is required as well. On the software side, understanding the concepts of activation and depassivation of I/O channels is critical, as is the use of specific functions (FC450-FC451) and function blocks (FB450-FB453). This takes a little practice and patience to set up your first redundant rack, but then it becomes easy to extend the concepts to additional racks. Special treatment of analog signals is required because analog cards behave a little differently in a redundant setup. This is all in the manual referenced above.
@mnada72
@mnada72 4 года назад
@@realpars Thank you for the detailed answer 💎
@ela11035991
@ela11035991 6 лет назад
Best
@abdelakderkameleddinemamme4739
How to Configure an S7-300 Redundant PLC HW and SsaftW in tia portal
@scottsommer5450
@scottsommer5450 5 лет назад
This is a complex question. Hardware redundancy is S7-3xx is not supported by Siemens. It is supported by certain S7-400 CPU's. You would configure a software redundant S7-300 PLC pair in TIA Portal in the same way that it is done in STEP7. You would need to configure 3 ProfiBus networks: 1) PLC-A CPU to an IM-153 module in each I/O rack; 2) PLC-B CPU to a separate IM-153 module in each I/O rack from the one used for PLC-A; and 3) a Profibus network connecting a CP module in the PLC-A rack to a CP module in the PLC-B Rack. More info can be found in Siemens document A5E02171565-02. This just scratches the surface of setting up the entire application.
@abdelakderkameleddinemamme4739
@@scottsommer5450 Can I do this at tia portal ?
@scottsommer5450
@scottsommer5450 5 лет назад
@@abdelakderkameleddinemamme4739 I have not tried this myself, but there is nothing that was configured in STEP7 in this video that is unique just to STEP7. The functions of NetPro are now handled by the various tabs in the "Devices & Networks" builder in the Devices tree of TIA Portal.
@abdelakderkameleddinemamme4739
@scott sommer Can you send me a link for software redundancy because I did not know how to downlowd it ?
@scottsommer5450
@scottsommer5450 5 лет назад
@@abdelakderkameleddinemamme4739 support.industry.siemens.com/cs/attachments/1137637/S7_swr_b_en-US.pdf?download=true Clicking on this link will download the applicable document to your Downloads folder.
@Shiva68
@Shiva68 5 лет назад
Wow ...
@derina.maleek9408
@derina.maleek9408 5 лет назад
I love you men
@EngFORAT
@EngFORAT Год назад
💐💐💐👍👍👍
Далее
How to Configure an S7-300 Redundant PLC _ PART 1
7:29
What is a Redundant Power Supply and How Does It Work?
6:49
What is a PID Controller? | DigiKey
22:19
Просмотров 86 тыс.
What is the Difference between Profibus and Profinet?
5:28
Introduction to ET 200SP Base Unit (Overview & Usage)
12:23
What is HART Protocol?
17:01
Просмотров 1 млн
What is the Difference Between PLC and DCS?
11:23
Просмотров 1,3 млн
PLC Analog Inputs and Signals
8:55
Просмотров 713 тыс.