Тёмный

How To Enable Sync Protocol on a Notifier NFS-320 or NFS2-640 

AlarmSystemTech
Подписаться 2 тыс.
Просмотров 14 тыс.
50% 1

Thanks for watching! If you enjoy my content don't forget to like, comment and subscribe!
Check out my eBay store: www.ebay.com/usr/firealarmsup...
Follow me on Instagram: / alarm.system.tech

Наука

Опубликовано:

 

29 авг 2020

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 18   
@vafirecollector9547
@vafirecollector9547 3 года назад
Thank you! This was very helpful, don't know why I couldn't figure this out.. even when I'm reading through the manual haha
@AlarmSystemTech
@AlarmSystemTech 3 года назад
Glad I could help. It's much easier explaining it in a short video than typing it all out lol.
@vafirecollector9547
@vafirecollector9547 3 года назад
@@AlarmSystemTech I do agree its easier seeing it in a video rather than in text sometimes. But! I just programmed the sync and works like a charm. But overall these are great panels, although I do have another question.. is its possible to expand off the 320, and make it a two or three bay panel with an AMG-1 attached kinda like your 640?
@AlarmSystemTech
@AlarmSystemTech 3 года назад
VAFireTech122 The 320 and AMG are not compatible. NCAlarms has confirmed this.
@eng-anwerkadhim5335
@eng-anwerkadhim5335 2 года назад
dear sir. thanks for supporting this was vary helpful. i really appreciate if can help me. how can add smoke detect that was deleted from system
@YZFR16666
@YZFR16666 3 года назад
I have a notifier 640 , after an annual inspection , we had 2 annunciators (acm-24at) and the udact go "inv reply" , a little trouble shooting i was able to get the udact to come back online by disconnecting the 2 annunciators from the system but when the annunciators are powered back up they take down the udact, any idea what i might have going on here?
@bob5074
@bob5074 3 года назад
I really wish Notifier would let us refer to the NFS-640 and 320’s NAC circuits in logic equations.
@JOSE20805
@JOSE20805 2 года назад
Hello, very helpful video. I’m trying to silence my horns but still keep strobes flashing. When I hit silence system everything including strobes turn off. Would you know what I need to do to get that function going ?
@AlarmSystemTech
@AlarmSystemTech 2 года назад
NFPA no longer allows audible silence. I’m guessing your AHJ wanted this. You have to go into point programming and select & for the strobe output. You’ll then see *FW change that to **W.
@JREQ-tv1wm
@JREQ-tv1wm 2 месяца назад
How to install printer?
@Roxxofoxxo
@Roxxofoxxo 3 года назад
Can each NAC do a different coding/sync option or no? If yes, how?
@AlarmSystemTech
@AlarmSystemTech 3 года назад
No
@Roxxofoxxo
@Roxxofoxxo 3 года назад
@@AlarmSystemTech Oh alright Thanks for the quick reply!
@muhammadjawadhaider2152
@muhammadjawadhaider2152 3 года назад
Hi, can u tell how to rectify "corrupt program" trouble?
@AlarmSystemTech
@AlarmSystemTech 3 года назад
Muhammad Jawad Haider You’ll need to upload and download the database with VeriFire Tools.
@muhammadjawadhaider2152
@muhammadjawadhaider2152 3 года назад
@@AlarmSystemTech programming is out of my scope, there is 3rd party to come and solve such issues. Is there any other way to solve that kind of issues?
@AlarmSystemTech
@AlarmSystemTech 3 года назад
@@muhammadjawadhaider2152 I'm afraid not.
@muhammadjawadhaider2152
@muhammadjawadhaider2152 3 года назад
Can we get device maintenance list from notifier system, like we can see in est3 systems?
Далее
Chapter 23  - Troubleshooting Panel NFS-320 NOTIFIER
8:35
Разоблачение ушные свечи
00:28
Просмотров 736 тыс.
Склеил девушку-курьера ❤️
01:00
Fire System Test (NFS-320R & ECC-50/100)
3:03
Anular y Habilitar equipos Notifier NFS-320 y 640
2:38
Auto Program NFS-320E@NFS2-640E
5:37
Просмотров 3,4 тыс.
How to bypass a Zone on a Notifier NFS2-3030 FACP
2:10
Systems In Action #9 - Notifier NFS-640 with NCA
6:09
Notifier NFS2 640 Programming Guide
28:30
Просмотров 26 тыс.
Проверил, как вам?
0:58
Просмотров 378 тыс.