In this edition of Training Tuesday, Baxi trainer Richard shows you how to check the Hall Effect sensor on a boiler (such as the Baxi Duo-tec or Platinum combi boiler) without using a multimeter.
For full details of our product range, head here: www.baxi.co.uk/our-boilers
Check out our training courses here: www.baxitraining.co.uk
Join our Baxi Works installer loyalty scheme here: www.baxiworks.co.uk
Please note: This video is intended for Gas Safe registered engineers only and is subject to our full video disclaimer which can be found here: www.baxi.co.uk/video-disclaimer

Наука

Опубликовано:

 

11 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 15   
@smalltounboy
@smalltounboy 2 года назад
Thanks for the screw hack, I would never have thought of that
@petermoussot8757
@petermoussot8757 Год назад
Thanks, great video! Had a hot water issue. This allowed me to trouble shoot. Sensor is ok so now I know to change the Magnetic flow sensor. You solved my problem!
@MH-er4fs
@MH-er4fs 2 года назад
Thanks very much.. you guys have the simplest most effective tips and your training courses are brilliant.. Baxi all day every day!!
@BaxiBoilersUK
@BaxiBoilersUK 2 года назад
Thank you so much, it means a lot to receive feedback like that!
@gedheaton1415
@gedheaton1415 10 месяцев назад
X2 @@BaxiBoilersUK
@mas1176
@mas1176 2 года назад
This Man is The Legend Himself met Him directly Amazing Man GeneraL coas=Chief of Army Staff
@willlomas2725
@willlomas2725 8 месяцев назад
Great video..thank you.
@naturelover_9211
@naturelover_9211 2 года назад
Brilliant thanks.
@raul835
@raul835 2 года назад
Brilliant
@coolcashclips
@coolcashclips 2 года назад
Awesome 👍
@johnmac8072
@johnmac8072 Год назад
Hi Richard, So if the sensor does light when we test but does not light when installed what could be the issue? I have an issue when the sensor is installed but it does not light when they run the DHW tap. They have good water pressure so I suspect it is a mechanical issue with the bobbin. Any thoughts would be much appreciated.
@salam238
@salam238 2 года назад
So after testing, it would be needing to change then?
@BaxiBoilersUK
@BaxiBoilersUK 2 года назад
Hi Abdul, if you carry out the test as described in the video and the light does not illuminate, then yes you would change the hall effect sensor. Thanks for your question.
@subevo35
@subevo35 7 месяцев назад
Good stuff
Далее
Zlatan embarrasses Speed 😂 #ishowspeed
00:32
Просмотров 10 млн
How Many Balloons Does It Take To Fly?
00:18
Просмотров 25 млн
Would you help?!😳
00:32
Просмотров 6 млн
Gas Training - How To Test A Boiler Fan - Combi Boiler
22:58
Component Testing Using A Multimeter - Part 3 (of 3)
17:05
Как работает экосистема Apple?
18:08
Собери ПК и Получи 10,000₽
1:00
Просмотров 2,4 млн