How to wire in a new 220v outlet for air conditioning! We'll be using a retro fit box to install a new outlet in the wall, then run 10/2 (and 10/3 because I didn't want to buy more wire), and connect the wire to the breaker panel.
Social Media:
Twitch: / rdallen
Instagram: / therdallen
Facebook: / rdallengaming
Twitter: / randydozeman
Support the Channel!
Patreon: / rdallen
Get Your Own RDAllen Shirts: shop.spreadshirt.com/rdallen/
Monthly Snacks! www.universalyums.com/?ref=yum...
Music: www.purple-planet.com

Игры

Опубликовано:

 

7 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 61   
@tenwalls2428
@tenwalls2428 4 месяца назад
Best practices would be to redesignate the white 10/2 with black tape when connecting it to the red 10/3 in the jbox. For sure would do it at the breaker.
@shannoneastwood2233
@shannoneastwood2233 2 месяца назад
When I seen you start without trying to find stud I said watch he hit a stud I be dame you couldn’t have hit it more center stud lol😂
@radozeman
@radozeman 2 месяца назад
Oh I hit that one right in the center! Stud finders don't work really well on lathe and plaster walls in my experience, pretty much just cut and hope you find what you are looking for.
@feardabeard7635
@feardabeard7635 Год назад
And when you need to find a stud you end up putting 1000 holes in your drywall. lololol
@radozeman
@radozeman Год назад
Right lol!
@jrgtz7023
@jrgtz7023 Месяц назад
Like the way it was explained and like the can do attitude, Nicely done Sr.
@radozeman
@radozeman Месяц назад
Thank you!
@gedionsamuel2256
@gedionsamuel2256 Год назад
Nice dual inverter 👌
@radozeman
@radozeman Год назад
Yes I’ve been really happy with it for a window air conditioner!
@shawnw6486
@shawnw6486 Год назад
I'm trying to wire a 6-15 outlet. I have 2 blacks, 2 whites, and a ground. Everyone i tried watching that wired it only had 1 black, 1 white and a ground so they repurposed the white neutral into a hot. Where i have 2 sets of wires, am i able to connect a black to each side, my ground and then cap off my neutrals?
@A-privilege-not.a-right
@A-privilege-not.a-right День назад
Did you ever announce baseball games? You got that voice.
@redsoxvette
@redsoxvette 10 месяцев назад
You should do voice work for the Simpsons 😅
@kjvtruther6374
@kjvtruther6374 Год назад
Great video . I needed this.
@radozeman
@radozeman Год назад
Oh power for AC is always needed! lol
@trevorbelmont4633
@trevorbelmont4633 7 месяцев назад
Maybe its good to Mask the areas to be cut first to prevent paint from chipping too much?
@radozeman
@radozeman 6 месяцев назад
If you really care about it yes! In my case I’m replacing the wall so… eh….
@KevinCoop1
@KevinCoop1 8 месяцев назад
It’s nice that you have a spare Square D breaker in the bottom of a Cutler Hammer panel. NEC violation, you installed a single 250 volt receptacle rated at 20 amps on a 30 amp branch circuit. That’s a no no. It could have been a 15 or 20 amp circuit and device, based on the AC being 9 amps. Not going any further.
@radozeman
@radozeman 8 месяцев назад
What, the breaker that is just lying in the bottom? It's not installed is it? Where that breaker came from I don't know, it was in the panel when I bought the place.
@user-ik7ky1hj3y
@user-ik7ky1hj3y 14 дней назад
Hi kevin. I am not an electrician but I have a question. I’m trying to wire a 230/208v 10/2 wire to my breaker panel. What size double breaker do I need so I won’t burn my house down? Thanks in advance!
@emuench155
@emuench155 Год назад
Hi, I bought a 220V air conditioner and the surge protector on the cord will not reset. It's the same plug as yours. My outlet has 120V on each of the prongs, and a ground. Three wires. Convinced it was the surge protector and I didn't want to have to drag a 130-lb AC back to Home Depot, I chopped the GFI off and direct-wired it. Still didn't work (no surprise, b/c it had tiny sensing wires in the cord). Bought a new different AC, tho same brand, and it's the same as yours (LG #LW2422IVSM); imagine my surprise when it also won't reset; the pilot LED on the cord GFI also never illuminates. This is in my shop, which gets 60A thru 3-wire service via a 60A breaker in my house; one hot goes to each bar, and bare goes to ground/neutral, where all the white/bare wires get connected. My outlet has 115V in each leg. The box for both AC's says 220V, and the manual points out the 220V plug, so I'm assuming it wants 115 in each leg; it draws up to 2290A, so it'd have to be across two 115's, right?. It says it needs a wall receptacle that's "Standard 240V, 3-wire grounding receptacle rated 15A/240VAC/60Hz". I can pull the plug out halfway and with my voltmeter read 115V on of the two powered prongs. House is from '89, shop was added sometime later (before me). Is the GFI on these things maybe too touchy to work in this setup? Perhaps important, the 50A breaker/wire that supplies my outlet branches in the wall to also power a 30A welding outlet (still 115 on each leg and one ground/neutral). I currently have two smal 120V AC's, one old and one new, both with cord GFIs, running on separate circuits in the shop with no problem. Many, many thanks; just moved to Texas and it's getting very hot here :-).
@emuench155
@emuench155 Год назад
Pulling the big outlet and wire-nutting the wires together didn't help. What DID help was discovering the 2-pole breaker in my shop breaker box was not a dual-space (or whatever you call it), so it was pulling both 120's from the same leg. I replaced the breaker with a dually so the leads come from different legs and now the GFI is happy. Seems like an important detail to point out in the instructions :-). Finally figured it out because I calmed down and prayed for help. Followed the power and there it was :-).
@radozeman
@radozeman 8 месяцев назад
@@emuench155 I must have missed this comment! Looks like you have it figured out, and it was exactly what I figured it was! I was going to suggest checking if you actually have 220! If you measure both hots you should have 220-240 volts, each hot to neutral/ground should be 110-120
@jftman53
@jftman53 14 дней назад
Stud finder?
@user-ds6rt3kx5j
@user-ds6rt3kx5j 10 месяцев назад
Do you run wire to inside breaker box or box outside on the pole
@radozeman
@radozeman 10 месяцев назад
Inside breaker panel in my case.
@wolfcantswim
@wolfcantswim Год назад
What kind of framing is that? With the wall having those horizontal posts
@radozeman
@radozeman Год назад
Do you mean the lathe behind the plaster?
@wolfcantswim
@wolfcantswim Год назад
@@radozeman Yeah
@ivane.degonzalez7520
@ivane.degonzalez7520 11 месяцев назад
That's what they used to used to put on plaster walls in the old days before sheetrock.
@jeffnanozny3795
@jeffnanozny3795 7 месяцев назад
Can I use the yellow 12/2 for the ac unit and nothing else will ever hook to this
@radozeman
@radozeman 7 месяцев назад
Only if you use a 20 Amp breaker and your AC will run on a 20 AMP breaker.
@CreativeVisionzGroup
@CreativeVisionzGroup 5 месяцев назад
Brooo…I truly dig the voice over lol are you a Pilot…feels like I’m watching a pre-flight message lolol
@radozeman
@radozeman 5 месяцев назад
Nope, not a pilot.
@user-ik7ky1hj3y
@user-ik7ky1hj3y 14 дней назад
I’m trying to wire up a deceptively to my breaker box and I have a 230/208v cord on my new window air conditioner. Can you tell me how to wire this in layman’s terms. I’ve already wired a 220 into my breaker box to a double 20v breaker. I just can’t afford to get this wrong…! Any help please???
@alexanderplotnikov1424
@alexanderplotnikov1424 13 дней назад
How to connect next outlet or switch to specifically single outlet?
@radozeman
@radozeman 12 дней назад
In this case, you would have to use pigtails to the outlet. These outlets typically only hold one 1 wire
@bobbydbuilder2873
@bobbydbuilder2873 Год назад
I have a nema 10 20r. Has 2 gold and 1 silver screws. No green ground How do I wire it? Black and red on gold and white on silver? I need help
@bobbydbuilder2873
@bobbydbuilder2873 Год назад
It's 20 amp for a old air compressor
@radozeman
@radozeman Год назад
Sounds like the incorrect type of outlet/plug for that compressor. First is the compressor 220? Make sure it is, or wired for 220, some can be wired both ways. Black and red on gold, silver would be white, but you need green, technically it would work that way, but would not be correct.
@loganlease1
@loganlease1 11 месяцев назад
how many amp and volt does your ac need
@radozeman
@radozeman 11 месяцев назад
220v @ 9 Amps per the specs.
@carlthornton3076
@carlthornton3076 Год назад
Very Good!... #6 ✝ {8-21-2022}
@elfollador65
@elfollador65 11 месяцев назад
Someone can help me? What kind of braker he used?
@radozeman
@radozeman 11 месяцев назад
Depends on your panel, but you’ll need a double pole 220v breaker rated for the size of your air conditioner and wiring. I ran 10 gauge wire so I’m using a 30 amp breaker. My panel is a Cutler Hammer.
@damoncampbell8381
@damoncampbell8381 Месяц назад
That panel needs a remodeling because that thang is a cluster fuak After you organize the whole panel, pretty sure you'd be able to work on your appliances and circuit breakers easier, and to maintain.
@radozeman
@radozeman Месяц назад
Oh absolutely! Hasn't happened yet, but I'm planning on a 200 Amp panel upgrade! Panel, breakers, and wire are purchased.
@pakosuarez11
@pakosuarez11 Год назад
What is the single outlet number 30 amp to whats on the outlet
@radozeman
@radozeman Год назад
Not sure I understand what you are asking?
@pakosuarez11
@pakosuarez11 Год назад
@@radozeman yes can i use a 30 amp Orange cable with a single outlet that is 20A 250v
@luiszaragoza3721
@luiszaragoza3721 Год назад
Video was nothing fancy but to the point! 🤙🏼🍻
@phil20_20
@phil20_20 Год назад
You'd be better off doing a horizonal cut first. Then you would have known before you cut the whole thing. 😉😄
@radozeman
@radozeman Год назад
Possibly, could have tried a stud finder, might have help! Had to find studs sometimes in these lathe and plaster thoughs!
@slingshoter8783
@slingshoter8783 6 месяцев назад
that ac pulls 15 amps. Shouldn't that be ran on 14 gauge wire ? I bought the same AC and have to run some new wire is why i watched the video. nice job by the way. But was I was wondering about the wire size being to big if it could lead to warranty issues.
@radozeman
@radozeman 6 месяцев назад
That is true for 15 amps you can run 14 gauge wire and 15 amp breaker, though if the AC takes 15 amps you will want to run 12 gauge wire and 20 amp breaker. Breaker in my panel was 30, so for 30 you need to run 10 gauge wire, plus I already had that wire on hand. Wire size being too big would not cause a warranty issue!
@slingshoter8783
@slingshoter8783 6 месяцев назад
@@radozeman it is that duel converter one it has a 15 amp reset protection switch on the plug. I thought i seen it said it runs on a lot less amps being it a 220v . mine was delivered damaged fins the freon leaked out .. im waiting on the other one i bought to see for sure. With it being in the wall i set it to far in to read the side panel lo something else im going to fix.
@user-vt2vd4ek4b
@user-vt2vd4ek4b 17 дней назад
You shouldn’t use higher amp breaker but u can use the wire
@surferdude642
@surferdude642 8 дней назад
​@@radozemanThe wire gauge is okay, but the receptacle is only rated for 20 amps and the unit is rated for 15 amps. The internal circuitry of the unit is probably not rated for 30 amps, you should be using a 15 amp breaker.
@ConcreteJungle-tw4qj
@ConcreteJungle-tw4qj Год назад
Whos Erwin?
@jftman53
@jftman53 14 дней назад
Who is Evelyn?
@surferdude642
@surferdude642 8 дней назад
I think he said everyone.
@ToddMiley89
@ToddMiley89 Год назад
Why are you talking like an auctioneer?
Далее
How To Install a 220 Volt Outlet
15:20
Просмотров 197 тыс.
Changing an outlet for an A/C 240v
1:01
Просмотров 26 тыс.
How to Get 220v From 110v
14:48
Просмотров 3,2 млн
How to Install and Wire a Sub Panel
35:23
Просмотров 1,3 млн
маленькие кошмары
2:58:44
Просмотров 209 тыс.
VALVE Починили Ранги в CS2! / PUBG
18:19
Просмотров 320 тыс.