Тёмный
No video :(

Hvac tripping it’s breaker :-( 

Restaurant Repairs
Подписаться 6 тыс.
Просмотров 760
50% 1

Опубликовано:

 

9 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 12   
@justanoldhandyman
@justanoldhandyman Месяц назад
I enjoy your proving what you tell us. 👍
@Ju1yan
@Ju1yan Месяц назад
"but also its here" made me laugh, brilliant joke, good videos in general thank you for making these videos they are very interesting and nice to watch
@harrydickson4575
@harrydickson4575 Месяц назад
👍👍👍
@berylwhite2983
@berylwhite2983 Месяц назад
Good call
@CubbyTech
@CubbyTech Месяц назад
I assume a hard start capacitor has the opposite effect of a soft start? :D
@MariosACandRefrigeration
@MariosACandRefrigeration Месяц назад
Every 1 ph cooler with txv should have a hard start,and every ac unit 1 ph with txv would be better off with a hard start of any kind IMHO.
@restaurantrepairs
@restaurantrepairs Месяц назад
Ewwww. 😂. Naw I love different perspectives especially such experienced ones. I guess I always viewed a hard start as an “it needs a little extra boost” which if that’s the case your on borrowed time. But Mayhap your starting point is more educated. Appreciate the insight
@brentgong2412
@brentgong2412 Месяц назад
Why dont you like the 2 wire hard start capicator?
@restaurantrepairs
@restaurantrepairs Месяц назад
I’m open to critique but how it “works” is it offers a greater charge to those units that have become “hard to start” Meaning in this case that compressor needs 70mfd to get it started. He gave it 70 and it still didn’t so he added a hard start kit and boom she’s running. It’s a shock start and if your compressor needs that, use a hard start to buy you time to replace the compressor. If you just try to run that way it always seems I find dead compressors behind hard start kits. The kits didn’t kill them. The kits treats the symptom not the cause. The cause is a dying compressor. So. If you need a hard start kit, you really need a compressor. My 2 cents
@brentgong2412
@brentgong2412 Месяц назад
@@restaurantrepairs You mentioned that you would use a 3 in 1 all day long. Whats the difference? Thanks for answering
@restaurantrepairs
@restaurantrepairs Месяц назад
@brentgong2412 - a 3 in one is sized appropriately for the hp of the compressor your using. It’s rated in a certain area of appropriate power. Hard start kits are slapped on 1/2 hp to 5 hp units. They just zap the $h!t out of whatever till it starts.
@waynetirrell2358
@waynetirrell2358 Месяц назад
looks like compressor wire is exposed here, or maybe I'm seeing things 😅ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-CMwBhR4zZmU.html
Далее
The Old Goodman AC has a FAKE Hard Start Capacitor
12:16
女孩妒忌小丑女? #小丑#shorts
00:34
Просмотров 24 млн
❌Ему повезло больше всех #story
00:41
When A Gang Leader Confronted Muhammad Ali
11:43
Просмотров 7 млн
SOMEONE MESSED UP BIG TIME
28:20
Просмотров 87 тыс.
HVAC Contractors Hate Me For Sharing This Secret
10:21
Просмотров 878 тыс.
HVAC Scam failed again on 2nd opinion call
18:59
Просмотров 153 тыс.
DIY Vapor Compression Refrigeration System
28:06
Просмотров 1,1 млн
"Flammable" Refrigerant Facts for Residential HVAC
1:02:01
Changing a "Smart meter" - 3 phase
15:29
Просмотров 45 тыс.
HVAC Installation: Brazing Refrigerant Lines
7:35
Просмотров 4,5 млн
女孩妒忌小丑女? #小丑#shorts
00:34
Просмотров 24 млн