Тёмный

Install a new 240 Volt 50 Amp cable for Electrical Range - Part 3 - Connection To Circuit Breaker 

Joseph K
Подписаться 27 тыс.
Просмотров 267 тыс.
50% 1

This video How to install a new 240 Volt 50 Amp cable (240V/220V cable) for Electric Oven, Range Electric outlet or Adding 220 Volt outlet for Electrical Range and connecting a 6/3 Oven Power Cable, 4-Wire Outlet to Electrical Panel 240 cable to a new circuit Breaker amzn.to/3hVQ6LO or Wiring a new 240 volt circuit and Connecting to the Electrical Panel shows how to connect a new 50 amp 240 breaker in the breaker panel to a 240 Volt volt cable in order to add a new 240 Volt 50 Amp outlet for an electric oven, Range. The cable is pulled from the kitchen o the electrical panel and installing the 50 Amp circuit breaker.
Buy 50Amp Siemens amzn.to/3hVQ6LO
Buy 200Amps Breaker Box = amzn.to/39fCk5X
Digital Multimeter = amzn.to/3oqGZ9K
Amazon Deals:
Try Amazon Prime 30 days for free = amzn.to/2JMWaLe
Create Amazon Business account = amzn.to/3mLSyYt
Joint Amazon Prime Watch Thousends Of Movies and TV = amzn.to/33NfsHD
Try Personal Shopper Wardrobe amzn.to/2VClfv9

Хобби

Опубликовано:

 

10 дек 2019

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 255   
@josephk9182
@josephk9182 3 года назад
50Amp Siemens amzn.to/3hVQ6LO 200Amps Breaker Box = amzn.to/39fCk5X 6/3 50 Amps 125' cable = amzn.to/2UWTq3x Digital Multimeter = amzn.to/3oqGZ9K Amazon Deals: Try Amazon Prime 30 days for free = amzn.to/2JMWaLe Create Amazon Business account = amzn.to/3mLSyYt Joint Amazon Prime Watch Thousends Of Movies and TV = amzn.to/33NfsHD Try Personal Shopper Wardrobe amzn.to/2VClfv9
@dimitriberozny3729
@dimitriberozny3729 Год назад
You can use 8/3 wire if range is only a few feet from the breaker box.
@bazilsyed8855
@bazilsyed8855 Месяц назад
For stove. 40 Am.Braker
@tigre2236
@tigre2236 4 года назад
This video was just slow and repetitive enough for my layperson's mind to grasp how it works. Perfect! Thank you so much!
@Yeakerr
@Yeakerr 5 месяцев назад
Thank you my dad was a electrician he recently passed away so I couldn't call him for help but this showed me how.
@josephk9182
@josephk9182 5 месяцев назад
Any time.
@cidllcpro4417
@cidllcpro4417 2 года назад
This was well done , thank you for being so patient to your audience. It was one of the best explanations I've seen. I belive it had to do with the fact that you talk slow and relaxed, explain thing two or three times to make sure the viewers get it.
@josephk9182
@josephk9182 2 года назад
Thank You.
@michaelteel8490
@michaelteel8490 4 года назад
Thank you! Definitely worth watching through especially if you're new and just learning electrical stuff
@josephk9182
@josephk9182 4 года назад
Any time
@radchander
@radchander 3 года назад
Nice video....slow and steady, and no unnecessary haste. Close up of breaker anatomy is really thoughtfu and useful. Thank you,
@josephk9182
@josephk9182 3 года назад
Any time.
@watchmenpropertyinspection3469
@watchmenpropertyinspection3469 4 года назад
what a great job explaining everything. thanks so much
@rmcfadde1
@rmcfadde1 4 года назад
Thanks for the pointers. After reviewing several hours of DIY videos (such as yours), I was able to install my tesla gen 2 HWPC. It was a total pain in the..... but still saved me about 1k doing it myself. I'm going back to all the videos that I was able to get some key information and leaving a "thank you".
@josephk9182
@josephk9182 4 года назад
Thank You.
@chezchezchezchez
@chezchezchezchez 2 года назад
What other info do I need? I want to do same job!!! Thx
@rmcfadde1
@rmcfadde1 2 года назад
@@chezchezchezchez I had zero electrical experience so I had to start from the very basics. I downloaded the install instructions from Tesla then whatever questions I had, I simply "googled" or "youtube'd" for answers. I had to buy all new tools since I didn't have any. I ended up doing a lot of overkill on my setup....I used 6gauge wire which really wasn't necessary..... used a 240 load circuit breaker which was also overkill. It took about 1 week of research.....2 weeks for parts to show up from from home depot (wire and circuit breaker) and maybe 8hrs for the actual install. After installing, I do recommend having an electrician come by and have everything checked out.
@chezchezchezchez
@chezchezchezchez 2 года назад
@@rmcfadde1 The electrician charges $120 to show up, and $80 an hour. If I’m gonna have them just check it out, I might as well have him install the damn thing. Right?
@rmcfadde1
@rmcfadde1 2 года назад
@@chezchezchezchez In my case, the install was going to cost $1400... that wasn't the issue. The issue was they were backed up by 3 months....I didn't want to wait that long....I was ready to drive/charge my car asap. If you are driving a 40k-80k vehicle... just pay the $120 or $200 to have your electrician do a buddy check..... or don't!! Like I said, I didn't know what I was doing so I felt I needed the double check. Good Luck and take care!
@ijohnny.
@ijohnny. 3 месяца назад
Very thorough demonstration. I learned how to do it! Other videos rush through the wiring of the breaker. Thanks, Joseph.
@josephk9182
@josephk9182 3 месяца назад
Any time.
@anthonyfonteno7688
@anthonyfonteno7688 7 месяцев назад
Excellent teacher. The best video on the internet to install a 240
@josephk9182
@josephk9182 7 месяцев назад
Thank You
@salinsarin1
@salinsarin1 3 года назад
Really nice explanation.. All parts were nicely & patiently explained.. The repeating of important points during videos was very helpful for a layperson like me.. It gives more confidence & better understanding of the concept. I am less afraid of the electricity box now 😊. Thank you sooo much 👍👍🙏🙏
@josephk9182
@josephk9182 3 года назад
Any time
@rjf2483
@rjf2483 3 года назад
Great video and explanation! Extremely helpful to anyone connecting new wiring to circuit breaker panel.
@josephk9182
@josephk9182 3 года назад
Glad it was helpful!
@filomenamasci-wagman2138
@filomenamasci-wagman2138 4 года назад
Great educational video. I was able to install my own 240 v 50a thanks to you.
@josephk9182
@josephk9182 4 года назад
Great to hear!
@jakejohnson7714
@jakejohnson7714 2 года назад
Very nice going through everything 2 to 3 times THANK YOU!
@mannyhernan5339
@mannyhernan5339 2 года назад
Thanks for making the video! Not a lot people can make a video explaining everything well explained!
@josephk9182
@josephk9182 2 года назад
Any time.
@aarondavis8652
@aarondavis8652 4 года назад
Extremely helpful! Thank you
@josephk9182
@josephk9182 4 года назад
Thank You
@OVERKILL_PINBALL
@OVERKILL_PINBALL Год назад
Awesome video this is EXACTLY what I needed to know. Some people were telling me the ground and neutral were the same thing...
@josephk9182
@josephk9182 Год назад
Any time.
@Dr.Twisty
@Dr.Twisty 2 года назад
Thank you for being so thorough. Excellent video!
@josephk9182
@josephk9182 2 года назад
Any time.
@PatrickSalisMEDIA
@PatrickSalisMEDIA 3 года назад
Thank You for taking the time to teach us.
@josephk9182
@josephk9182 3 года назад
Any time.
@cuz6657
@cuz6657 2 года назад
Very exciting to learn this. Im ready to install my breaker now. Thanks!
@josephk9182
@josephk9182 2 года назад
You welcome.
@jakejohnson7714
@jakejohnson7714 2 года назад
THIS is the BEST TEACHER on youtube!
@josephk9182
@josephk9182 2 года назад
Any time.
@Rockmaniam500
@Rockmaniam500 Год назад
Very good at explaining how to install the breaker in the proper and safe way. Thanks for sharing it!
@josephk9182
@josephk9182 Год назад
Any time.
@ronshelton4013
@ronshelton4013 3 года назад
Did a great job, very detailed.
@mightypavers
@mightypavers 2 года назад
I love the details you showed. Really helped me understand. Thank you.
@josephk9182
@josephk9182 2 года назад
Any time.
@wrknabe
@wrknabe 4 года назад
Thanks,you showed me what i was trying to figure out.How you get 240 out of the panel.
@josephk9182
@josephk9182 4 года назад
Thank You
@manny1841
@manny1841 3 месяца назад
Best video on electrical box setup.
@josephk9182
@josephk9182 3 месяца назад
Any time.
@marilynbocanegra4960
@marilynbocanegra4960 3 года назад
Best yet I have found on internet u tube explaining...thank you very much
@josephk9182
@josephk9182 3 года назад
You welcome
@Norman1965arg
@Norman1965arg 2 года назад
Thank you for a very detail and easy explanation, very informative and easy to follow, I learn a lot thanks to you.
@josephk9182
@josephk9182 2 года назад
Any time.
@mikerosenblatt6827
@mikerosenblatt6827 2 года назад
Thank you for such a detailed explanation !!! Excellent !!
@josephk9182
@josephk9182 2 года назад
Any time.
@gl35
@gl35 2 года назад
Clear and precise presentation. Thanks for a very informative video.
@josephk9182
@josephk9182 2 года назад
Any time.
@eddiesampson2177
@eddiesampson2177 2 года назад
Very nicely done, well explained, thank you.
@edhenke8507
@edhenke8507 Год назад
Excellent Video. Very well done with great close-up shots.
@MetalFusion10
@MetalFusion10 3 года назад
It’s explained very well I appreciate you brother
@josephk9182
@josephk9182 3 года назад
Any time
@ramirorosiles7448
@ramirorosiles7448 3 года назад
Great video. You've just earned another subscriber here.
@briancrockett3625
@briancrockett3625 3 года назад
This is an awesome i-dont-know-anything video. I wish I found it years ago
@josephk9182
@josephk9182 3 года назад
Thank you
@KennyArrunategui-c9l
@KennyArrunategui-c9l 26 дней назад
❤ great video my friend, you help me out. I’m actually connecting a 50 amp for my generator. You explained it perfectly.
@ORam...
@ORam... 2 года назад
Thank you. Great video. This helped a lot.
@josephk9182
@josephk9182 2 года назад
Any time.
@joedunford6587
@joedunford6587 Год назад
great video, EXACTLY what i was looking for, A++++
@josephk9182
@josephk9182 Год назад
Thank you.
@blisswilsun2899
@blisswilsun2899 3 года назад
Your the best my friend 💛
@sydneyhill7546
@sydneyhill7546 3 года назад
I only have a 60a and a 40a breaker on hand. Could I use one of those?
@oscarmosca1234
@oscarmosca1234 3 года назад
thank you for the video. i wont try it my self but now i can make a more educated decision.
@josephk9182
@josephk9182 3 года назад
Good luck.
@mx5499
@mx5499 3 года назад
Watched too many videos.. YOURS THE BEST.. THANKS A LOT...
@josephk9182
@josephk9182 3 года назад
Any Time
@peterbeater012
@peterbeater012 2 года назад
Thank you for the through demonstration sir.
@josephk9182
@josephk9182 2 года назад
Any time.
@Berrugasnoquiero
@Berrugasnoquiero Год назад
thankyou for explaining it so detailed and beautifully
@josephk9182
@josephk9182 Год назад
Any time
@Iduanereade
@Iduanereade 9 месяцев назад
Wait you mean to tell me you saving me 500 bucks? 😂😂😂😂😂 THANK YOU MY DUDE !!!
@josephk9182
@josephk9182 9 месяцев назад
Thank You
@servantofthelamb9037
@servantofthelamb9037 3 года назад
Awesome thank you very much im actually putting a shore power for my motorhome & its 240v 50 amps and i have a dog bone which converts my 50 amps to 30 amps so when i follow your installation proses i should have power from my breaker box to my 240v 50 amp outlet thank you very much for your video your a very good electrition ill be instslling to day just one question what guage was those wires? And can i find it at home depot? Thanks & God Bless you.
@jejemon123
@jejemon123 3 года назад
Best teacher I watched so far.
@josephk9182
@josephk9182 3 года назад
Thank You
@kevkev5935
@kevkev5935 3 месяца назад
This was very well explained. Thank you so much for putting this video together.
@bobgardner8730
@bobgardner8730 2 года назад
FANTASTIC VIDEO!!!!!!!!!!!!!! Thank you very much!!!!
@josephk9182
@josephk9182 2 года назад
You welcome.
@edgarsgarage1266
@edgarsgarage1266 2 года назад
It’s a long video but it’s very helpful!!! Thanks a lot
@josephk9182
@josephk9182 2 года назад
Any time.
@sirronbailey3109
@sirronbailey3109 3 года назад
Great video thanks !!!
@josephk9182
@josephk9182 3 года назад
Any time.
@mariodelgado-medina6671
@mariodelgado-medina6671 3 года назад
Thank you!
@josephk9182
@josephk9182 3 года назад
You welcome.
@Hamodyusa
@Hamodyusa 4 года назад
You are the best 👍
@josephk9182
@josephk9182 4 года назад
Thank You.
@gearhead5279
@gearhead5279 4 года назад
👍 understood.
@GaryYoung-eq1ph
@GaryYoung-eq1ph Год назад
This guy is one of the best!!
@josephk9182
@josephk9182 Год назад
Thank You
@jemalwright3414
@jemalwright3414 3 года назад
Great Video!
@josephk9182
@josephk9182 3 года назад
Thank You
@armymobilityofficer9099
@armymobilityofficer9099 3 года назад
He is working on a sub-panel. Grounds and neutral must be separate in a sub, but nit in a main panel. Some inspectors want the breakers to be made by the panel manufacturer,
@carapungo
@carapungo Год назад
Very good sir, you explained it clearly.
@josephk9182
@josephk9182 Год назад
Any time.
@coldmember
@coldmember 2 года назад
Thank you very much!
@josephk9182
@josephk9182 2 года назад
Any time.
@EngineerWithGuitar
@EngineerWithGuitar 3 года назад
It's a really minor issue, but a picky inspector might fail a DIYer for installing the NEMA 14-50 receptable upside down or for putting it too close to the floor. Ground terminal should be at the top of the receptacle, not the bottom. This is so that the range/dryer plug cable will go down towards the floor when installed correctly hence why it has to be a minimum height above the floor. Since this was installed so close to the floor, I suspect it was installed upside down on purpose so the plug's cable would go up instead.
@josephk9182
@josephk9182 3 года назад
You are correct and good you noticed it. It was my mistake. I latter rotted the 50 Amp receptacle 180 degrees so the ground will be toward the floor.
@federicomaisch6812
@federicomaisch6812 3 года назад
Very informative
@josephk9182
@josephk9182 3 года назад
Thank you
@futbol1972
@futbol1972 2 года назад
Good video. I have a 3 car garage/ man cave fully insulated, ceilings too and even the garage doors. Garage is about 660 sq ft with 8ft celing hight. The lowest tempature during Christmas will be 37 degrees farenhight. My questions is if I install a 5000-7000w electric heater, I have to installed a 240v outlet too right or it can be just hardwired?? Eventually I will buy a minisplit system and be getting rid of the electric heater. Will I be able to use the 240v outlet previously installed for electric heater when I install mini split in future?? Also we will be getting an electric car down the road so I will need a 240v outlet to charge car so what will be the correct pathway for my projects, install a 240v right now for electric heater so I have heater in man cave before Christmas or maybe just use propane heater just for that day🙄 until I figure out what minisplit system to buy?? Sorry for all the questions
@josephk9182
@josephk9182 2 года назад
You should install 240v/50Amps like I did for range. This will give you maximum of12KW. You can use it for EV car or for heater.
@GaryYoung-eq1ph
@GaryYoung-eq1ph Год назад
Learned a lot from you!!!!
@josephk9182
@josephk9182 Год назад
Any time.
@billwdwc
@billwdwc 2 года назад
Nice video. Quick question. If I check from EACH hot to GROUND I should also 120V correct? Thanks
@josephk9182
@josephk9182 2 года назад
Yes .
@Jamorant12grizz
@Jamorant12grizz 3 года назад
as an experienced electrician i say everything he says is right but would never send people operating this equipment without proper qualifications, youtube is great for diy ers but some stuff is too risky to try from this video alone
@chezchezchezchez
@chezchezchezchez 2 года назад
RU-vid is great for learning all about toilets. It was wonderful for me. 🤪
@Redandranger
@Redandranger Год назад
What is too risky about this? As long as you make sure nothing is hot as you work on it, this is not rocket science. Yes, there are other electrical repair/installs that are more complicated/dangerous but this sure isn't one of them.
@Jamorant12grizz
@Jamorant12grizz Год назад
@@Redandranger dont know where you are from but where i am we understand that even after a successful installation over time problems may occur, there’s a code to go by, wiring methods . this video alone doesn’t say everything. i know the bill can be high but at this point make sure a professional is performing the work. i use youtube to learn stuff and when i do i watch more than one video, that way i make sure i know what i’m doing
@OldGuy70s
@OldGuy70s Год назад
So whats the Diff between 3 wire cables, and 4 wire cables.? white, red, black and the bare one... or black, white and bare wire...
@mathewshoyt1763
@mathewshoyt1763 4 года назад
good job..howver, i dont think you want to the hot wires too short on the breaker. having the plastic too far in could cause arcing and therefore overheating on the cable sheeting
@josephk9182
@josephk9182 4 года назад
Not true. The cable is 50 Amps cable. The maximum current that Range can take is $40 Amps. This cable only start to get hot if the current will go over 50 Amps. But if current is going over 50 Amps the breaker will break the circuit (disconnect power.) By the way the insulation of the wire is fire resistance.
@gaffneyguy8389
@gaffneyguy8389 4 года назад
I agree with Joseph. It seems like arcing would only be more likely if he had left more wire exposed
@timmybui6062
@timmybui6062 2 года назад
Thank you so much sir
@josephk9182
@josephk9182 2 года назад
Any time.
@freddygutierrez902
@freddygutierrez902 3 года назад
Thank you
@josephk9182
@josephk9182 3 года назад
Any Time
@williamho4739
@williamho4739 3 года назад
Good overview. 1. The ground/neutral does not come from the electrical company. It comes from the ground stake into the ground. 2. General Electric and Siemens are not compatible. May fit bit not approved UL method and should fail inspection. 3. May want to lockout the main to prevent a family from switching it on while you work.
@josephk9182
@josephk9182 3 года назад
The neutral come from the transformer of the electrical company. The ground is a wire connected to a cupper rod or a water pipe which are in the ground at least 2 feet. 2. It is incorrect. GE breaker is preferable but not a must. I had an inspector. Any breaker sold in US must be according to the electrical standard In the US. 3. The house was empty, if it was not I would locked the box.
@williamho4739
@williamho4739 3 года назад
Joseph K thanks for the response! Sorry it is a matter of perspective. I see often the neutral bonded to the ground at the service entrance. / As for the breakers unlisted on the panel label, I did not know of the other allowable provision you stated.
@josephk9182
@josephk9182 3 года назад
@@williamho4739 Thank for make it clear.
@jasminerogers9971
@jasminerogers9971 Год назад
Thank you 💙
@josephk9182
@josephk9182 Год назад
Any time.
@EmpireTextbooks
@EmpireTextbooks 3 года назад
Should a 50 amp breaker be used for most ranges? And a 6/3 wire? I have a standard 30” GE Range but it doesn’t specify what to use in the user’s manual
@josephk9182
@josephk9182 3 года назад
You should use 6/3 wire. Usually a range will take maximum 40 Amp when all heads are on. You breaker should be slightly above 40 Amps which is 50 Amps.
@EmpireTextbooks
@EmpireTextbooks 3 года назад
@@josephk9182 great thanks for the reply! You video was extremely useful and I’m now confident in doing this installation.
@josephk9182
@josephk9182 3 года назад
@@EmpireTextbooks Good luck.
@gerohansalas9046
@gerohansalas9046 4 года назад
thank you for this video i am now ready to install a 50 amp outlet for my 50 amp motorhome now to find out what size wire i need to do the connection ? ...
@josephk9182
@josephk9182 4 года назад
Please use a 50 Amp cable 660 V . Please look at video part 1.
@gerohansalas9046
@gerohansalas9046 4 года назад
@@josephk9182 would that be #6/3 copper
@gerohansalas9046
@gerohansalas9046 4 года назад
@@josephk9182 romex #6/3 copper
@josephk9182
@josephk9182 4 года назад
@@gerohansalas9046 Yes.
@gerohansalas9046
@gerohansalas9046 4 года назад
@@josephk9182 thank you
@jamesford1577
@jamesford1577 Год назад
Great video! I have electric stove 40 amp breaker. However the cable is 4 wire just like the one u have on video, I was wandering is it ok to live it like it's?
@josephk9182
@josephk9182 Год назад
Yes it is OK.
@jamesford1577
@jamesford1577 Год назад
@@josephk9182 good to know thanks!
@EmpireTextbooks
@EmpireTextbooks 3 года назад
What do you do if you don’t have a switch outside next to the meter to turn off the power? Can’t you just turn off the main switch within the circuit breaker panel?
@josephk9182
@josephk9182 3 года назад
I did not have main switch in the circuit breaker panel that turn off electricity to the panel. If you have a main breaker switch that shout off electricity to the panel you should use it. After you turn off electricity to the panel You must verify that there is no electricity in the panel !!.
@wslwang
@wslwang 2 года назад
thank you
@josephk9182
@josephk9182 2 года назад
Any time.
@RobertBuddDwyer45
@RobertBuddDwyer45 10 месяцев назад
I get 99 volts on leg 1 and 136 volts on leg 2 but get exactly 240 volts from leg to leg.I also have 22 volts when testing neutral to ground at receptacle. Any ideas of what's happening?
@josephk9182
@josephk9182 10 месяцев назад
You have some issue here. The potential between the natural and the ground should be 0 unless you have a disconnection or load between the neutral and ground. Try to replace the breaker If it does not work I suggest you will use certified electrician.
@kurt2439
@kurt2439 3 года назад
When you're testing to see if the line conductors are energized you tested between the two hots. Wouldn't the voltage be 0 there even when they are energized since they're both at 120V?
@josephk9182
@josephk9182 3 года назад
No. Both are 120v from hot to neutral but from hot to hot is 120 + 120 = 240 V
@kurt2439
@kurt2439 3 года назад
@@josephk9182 Thanks for the video!
@josephk9182
@josephk9182 3 года назад
@@kurt2439 Any Time
3 года назад
By the way, both hot lines should be about 120 volts to neutral. Ground has nothing to do with it, other than that if there's a big potential difference between ground and neutral, you have a screwed-up electrical installation.
@josephk9182
@josephk9182 3 года назад
@ Wrong ! The potentioal from the hot to the ground is 120V.
@ikabarkrane16
@ikabarkrane16 3 года назад
What Oteri wire would you use
@josephk9182
@josephk9182 3 года назад
I am not sure what was your question. I used 6/3 cable (50 Amps 600V)
@navyretired230
@navyretired230 2 года назад
Does it matter if the red wire is on top of bottom screw?
@josephk9182
@josephk9182 2 года назад
No it does not matter.
@garyhawthorne1678
@garyhawthorne1678 2 года назад
can i us 6/2 wire
@viavictoreletrica3527
@viavictoreletrica3527 Год назад
Gostei
@josephk9182
@josephk9182 Год назад
Thank you
@MrGreatnessHimself
@MrGreatnessHimself 2 месяца назад
Ty sir
@lallen968
@lallen968 2 года назад
so the red and black wire, doesnt matter which hole to put right? in the breaker
@josephk9182
@josephk9182 2 года назад
Yes, that is correct.
@KevinCoop1
@KevinCoop1 3 года назад
Joseph. Very nicely done video! There are a couple issues you may want to address. Even though we all know Siemens breakers and GE breakers will fit in the other panels, a Siemens breaker was not tested not listed for use in a GE panel. Therefore a violation of NEC. Also, must follow written instructions from the manufacturer. GE will not tell you ok to install Siemens. I'm not sure why you think Siemens breakers are better than GE. The second thing is, NEC and manufacturers tell you do not put two neutral wires in the same hole in the neutral bar. This has been found to cause loose connections, arcing, and melted insulation. It is ok for the ground conductors though. Hoping this helps you. Please be safe, the life you save may be your own. Respectfully, Kevin
@josephk9182
@josephk9182 3 года назад
Thank you for the input. You can put Siemens breakers in GE panel. There is a standard for breaker that companies follows. Regarding put two neutral wires in the same hole I agree it will be better.
@ramirorosiles7448
@ramirorosiles7448 3 года назад
Kevin Coop can you provede the NEC article number if you're so kind? I'm studying the NEC book and would be great to gather that information. Thanks in advance
@KevinCoop1
@KevinCoop1 3 года назад
Ramiro Rosiles I am very happy to guide you. I am referencing NEC 2017. The first part of my comment is about listings. Please read all of 110.3, (A), (B), and (C). Equipment must be installed as listed meaning as it was tested. And also per manufacturers written instructions. As far as the second comment about neutral(grounded conductor) terminations in panelboards, please read 408.41. I hope this helps. Respectfully, Kevin
@ramirorosiles7448
@ramirorosiles7448 3 года назад
Thanks a lot for your feedback Kevin
@KevinCoop1
@KevinCoop1 3 года назад
Ramiro Rosiles For what purpose are you trying to learn NEC?
@toddrichards3176
@toddrichards3176 2 года назад
Maybe can y repeat what is N and what is ground. The black wires those come from area 51 right. I don't have a main could it be in the truck?
@josephk9182
@josephk9182 2 года назад
I do not understand your question?
@rockstaremilio
@rockstaremilio 3 года назад
Good!
@josephk9182
@josephk9182 3 года назад
Any time.
@TheSilverlocks
@TheSilverlocks Год назад
My panel does not have a neutral bar. Should I tie the neutral wire to ground at the outlet or at the panel?
@josephk9182
@josephk9182 Год назад
Yes you can.
@TheSilverlocks
@TheSilverlocks Год назад
@@josephk9182 yes I can WHAT? Either?
@josephk9182
@josephk9182 Год назад
@@TheSilverlocks Only in the panel !!! you can tie the neutral to the ground .
@TheSilverlocks
@TheSilverlocks Год назад
@@josephk9182 Thank you,
@josephk9182
@josephk9182 Год назад
@@TheSilverlocks Good luck
@elgatillo863
@elgatillo863 3 года назад
Where can I get that breaker box?
@josephk9182
@josephk9182 3 года назад
200Amps Breaker Box = amzn.to/39fCk5X comes with breaker also.
@jermico007
@jermico007 Год назад
ok, I know this video is over two years old but I had a question anyways. anyone can answer for me if t hey know. my Sisters house. its an electric range circuit. it has a 50 amp breaker I wish to replace and the wire on this video appears to be the same size as the one on my sisters house. it is aluminum. the draw of the range is 47.9 amps when everything is on full blast. the wire appears to be the same size but also it might be 6 gauge aluminum. if it is 6 gauge double pole breaker, is this wire ok for the range? also, is the size of the wire you are using 4 gauge or 6 gauge copper?
@josephk9182
@josephk9182 Год назад
6 gauge is perfectly correct. Remember the 50 Amps breaker will break the circuit when the effective current on the wire exceeds 50 Amps.
@michaelgrossmann6902
@michaelgrossmann6902 3 года назад
תודה רבה
@josephk9182
@josephk9182 3 года назад
Any time.
@boobletownbobby9255
@boobletownbobby9255 Год назад
Thanks for doing this video but I noticed one glaring issue with your panel. And I'm not trying to be one of those guys who points out everything you did wrong because you did a lot correct. This is a safety issue. You have neutrals double tapped under one lug on the bus bar. This is a major no no and against NEC code. If one of those neutrals is loose, it can cause arching and is a fire hazard. You have more than enough room to move those neutrals to their own lug on that side of the bus bar. With grounds you can do that, as long as they are the same size.
@josephk9182
@josephk9182 Год назад
I didn't do it . It was done by the contactor who built the house.
@bigtom1948
@bigtom1948 3 года назад
Why are there so many neutral and ground double taps? There are plenty of connection points and it's against code to do this as well.
@josephk9182
@josephk9182 3 года назад
nothing against code.
@rmcfadde1
@rmcfadde1 4 года назад
Thank you a ton for the upload, extremely helpful!
@josephk9182
@josephk9182 4 года назад
Thank You
@jamaalaziz9910
@jamaalaziz9910 3 года назад
If its a subpanel neutral and grounds have to be seperate.. not on main panel tho
@josephk9182
@josephk9182 3 года назад
This is the main panel !!!
@danboquist
@danboquist 3 года назад
@@josephk9182 No it isn’t. Your indooor panel is a sub panel. The primary disconnect outside is the main panel. In the outside panel, the neutrals and grounds would be bonded together. On a sub panel they are not bonded. If you didn’t have a disconnect outside, your breaker box would be the main panel and the grounds and neutrals would be bonded together.
@GuillermoGarcia-qc6eq
@GuillermoGarcia-qc6eq 4 года назад
Thank you so much
@josephk9182
@josephk9182 4 года назад
Any time
@frankt4700
@frankt4700 3 года назад
50amps wouldn’t that burn up the wire?
@josephk9182
@josephk9182 3 года назад
No. The wire is 6/3 designed for 50 Amps 600V
@OldGuy70s
@OldGuy70s Год назад
And im wondering why my electrician guy said i only needed 8 gauge wire instead of 6 gauge, for my 50 amp 240 volt welder hook up...... hmmm
@sofiadasa77
@sofiadasa77 3 года назад
what gage is the wire?
@josephk9182
@josephk9182 3 года назад
6/3 I bought it on Amazon: amzn.to/2UWTq3x
@sofiadasa77
@sofiadasa77 3 года назад
@@josephk9182 do i need 6/3 or 6/4 my stove is rated 50am 240v
@josephk9182
@josephk9182 3 года назад
@@sofiadasa77 6/3
@sofiadasa77
@sofiadasa77 3 года назад
@@josephk9182 thank u so much
@josephk9182
@josephk9182 3 года назад
@@sofiadasa77 Any time
@MyGarageWorkshop
@MyGarageWorkshop 3 года назад
You can’t always use Siemens or any particular brand. It has to be made for the panel.
@josephk9182
@josephk9182 3 года назад
The breaker built according to standard so you should be able to use diffrent breakers on diffrent board.
Далее
Does Current Flow Through The Neutral Wire?
7:41
Просмотров 326 тыс.
3 Mistakes I Made Installing a NEMA 14-50 Outlet
9:53
Просмотров 342 тыс.
How To Install a Sub Panel Start to Finish!
31:44
Просмотров 2,3 млн
Adding 220 Volt Outlets to the Garage
5:29
Просмотров 2,3 млн
Самогон из маракуйи
0:59
Просмотров 2,5 млн
Amazing weight loss transformation !! 😱😱
0:24
Необычное растение! 😱🌿
0:27
Просмотров 2,1 млн
Необычное растение! 😱🌿
0:27
Просмотров 2,1 млн