Real world plumbing where We will show you how to install a magnaclean professional 2 with a nice tip on how to work out how much pipework to cut out, from there we will demonstrate how to connect up the magnacleanse and start cleaning the system step by step.
Customer wanted 4 new radiators and a powerflush, as it was a 1 pipe system we decided a magnacleanse would be a better option, also there was only 5 original radiators left on the system plus the pipework to clean out, system had also been pre dosed.
We started off with good results but things didn’t go to plan in the end, that’s real world plumbing sometimes jobs go wrong or not the way you would suspect and you have to walk away and come up with a plan to get the results you want.
Let us know what you you think in the comments
Also the giveaway prize is revealed for the 1k giveaway, if you want to enter check out the linked video on todays upload
Subscription goal 1150/1500
Thanks again for all your support

Хобби

Опубликовано:

 

19 авг 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 31   
@shaneshankly4518
@shaneshankly4518 Месяц назад
Great video as always 👍 love how you show when things don't go smooth, the real life of plumber's
@lukebell8780
@lukebell8780 5 месяцев назад
Behind the pump between F&E and pump is the neutral point. So I’d say it’s the best place for the filter to go 👍. The boiler return is still under positive pressure
@shaunmcc9861
@shaunmcc9861 11 месяцев назад
Very informative....really interesting
@bluebulldog_uk
@bluebulldog_uk 11 месяцев назад
Thanks mate appreciated 👍
@smburr1
@smburr1 9 месяцев назад
Just watched the video. Sweep tees in-line with the flow will allow the heat
@LcLheat
@LcLheat 5 месяцев назад
Hello... how's the going.. not being a pain.. only a bit of a tip use an old towel to protect radiators when you agitate ,so you save the rads from being damaged.. invest in a thermal camera 📸 , so you can see radiator ,hot and cold and spots... and it all so helps when balancing rad systems...
@trieditusedit5846
@trieditusedit5846 11 месяцев назад
Excellent thanks mate. Quick question where would you fit the magnacleanse on a combi if there was the same issues you had. No filter and no room to fit one.
@bluebulldog_uk
@bluebulldog_uk 11 месяцев назад
Close to the boiler as possible to be honest on the return is preferred but if it really can’t get onto it flow is better than nothing, before any branches for rads as well 👍
@AlexRocks24-7
@AlexRocks24-7 11 месяцев назад
Good luck on the rads 🙏 Been there 😢
@bluebulldog_uk
@bluebulldog_uk 11 месяцев назад
Hopefully I can sort it mate 👍
@ChristianBHough
@ChristianBHough 11 месяцев назад
Hi mate. I noticed you didn't show the cold flush part. Did you link the cold main to cold feed for the mains flush. It may have heped with filing back up and avoiding the air locks.
@bluebulldog_uk
@bluebulldog_uk 11 месяцев назад
I’m leaving cleaner in there so didn’t wanna flush it out with cold mains flush but I have gotta go back so will do cold mains flush then, hopefully it will help 👍
@petersmith2650
@petersmith2650 6 месяцев назад
I’d be cutting out and repipe the open vent and feed as it’s likely heavily restricted with magnatite in that area, stick a magnet on it. One pipes are a nightmare, good luck and thanks for the vid👊
@bluebulldog_uk
@bluebulldog_uk 6 месяцев назад
They have had a combi fitted now 😅 I did take out open feed and vent when I installed new boiler and was pretty clear which was surprising
@leepickett3655
@leepickett3655 11 месяцев назад
@mattygeepph4115
@mattygeepph4115 11 месяцев назад
Top work mate I know it sounds mad but have you tried x800 it's abit more fast acting plus the vent and fill looks abit to far away from pump sometimes can be the cause of sludge keep up the good work 😎👍😎👍😎👍😎👍👍😎
@bluebulldog_uk
@bluebulldog_uk 11 месяцев назад
Yes mate on power flush or where I can’t pre dose I find x800 works really well…it’s normally my go to but because I pre dosed I thought just adding the ADEY cleaner would be ok, I will see when I go back 👍
@actorlyric
@actorlyric 11 месяцев назад
What I used to do was put a gate valve on the cylinder return so you can isolate it , much like a rad. Then I would remove the header tank & loop out the cold feed to the open vent with some hep & gate valve so you can flush both CF & OV biggest issue in open vent systems. I use x800 sentinel as its faster acting imo. Double dose if need be. Would of been better using a power flush machine then reverse flow it. With a one pipe system often or not when trying to flush, it bypasses the rad altogether. The connections on a one pipe tend to be sweep tees as opposed to standard tees & back in the 70's they'd use top bottom opposite on the rad connections so the flow through it would be better. Another thing that can happen is when a rad is closed it can stop the flow altogether through the system. That might be the reason why those rads don't work . One pipe systems are a nightmare and you only have to look at them for them not work 🙈 Great explanation about the maganacleanse 👍 Look forward to finding out why those rads don't work.
@bluebulldog_uk
@bluebulldog_uk 11 месяцев назад
Thanks for the advice mate, will keep you posted when I go back 👍
@thebear4740
@thebear4740 11 месяцев назад
Boilers in the kicken😂😂😂put some silicon grease on your magnaclean spigots 🤠
@gunsey876
@gunsey876 11 месяцев назад
think you would have had better results if you had gone for the powerflush rather than trying to lift the debris into the filter in the loft with the circulating pump and you could have reversed the flow 👍
@user-li8gr8ur8l
@user-li8gr8ur8l 6 месяцев назад
Don’t worry mate it happens to the best of us
@wolvolad25
@wolvolad25 11 месяцев назад
All my stop taps either dont close fully are ridiculous hard to turn, they dont ages well at all 2:07
@bluebulldog_uk
@bluebulldog_uk 11 месяцев назад
Always the same, gate valves am the worse for turning off and never turning back on again 😫😅
@johnward5006
@johnward5006 11 месяцев назад
You can only do your best given what you've got I always double dose with quality inhibitor, you can't go wrong. Sadly, back in the 60s,70s and 80's the ballvalve was often fitted in that position. The reasoning was based on the expansion tank being just that!, the water level would be set low to allow for for expansion. The ballvalve 's should have been fitted as per convention, but you can see the thinking, the water level would have been set very low.
@bluebulldog_uk
@bluebulldog_uk 11 месяцев назад
I’ve learnt something new there with the FE level cheers mate 👍👍
@MrRawMonkey
@MrRawMonkey 6 месяцев назад
That cylinder needs insulation.
@Mattj361
@Mattj361 10 месяцев назад
With it being a one pipe system you wont get the black water you would expect from vibra cleaning the rads as the pump doesnt actualy pump through the rads it pumps round the pipe under neath. Thats my understanding of it anyway.
@bluebulldog_uk
@bluebulldog_uk 10 месяцев назад
I’ve always been taught not to flush a one pipe, you won’t get very good results but I wasn’t sure if the results on this one with the magnacleanse
@Mattj361
@Mattj361 10 месяцев назад
@bluebulldog_uk I was always told only way to clean a one pipe was rads of and manually flush then
@bluebulldog_uk
@bluebulldog_uk 10 месяцев назад
@@Mattj361 I’m going back to install a combi and have quoted to repipe so when I do the clean on the boiler after install I’m going to have a look see what I think
Далее
HOW TO: Set Up ADEY's MagnaCleanse
9:19
Просмотров 10 тыс.
Elden Ring DLC - ПОДОЖГЛО ПОПУ!
07:26
Просмотров 472 тыс.
How To Price Plumbing or HVAC Jobs
8:18
Просмотров 10 тыс.
Flushing a microbore system
13:01
Просмотров 6 тыс.
ADEY MAGNACLEANSE CLEAN HEATING SYSTEM SLUDGE
21:49
Просмотров 247 тыс.
One moment can change your life ✨🔄
0:32
Просмотров 33 млн
World Record Tunnel Glide 🪂
0:19
Просмотров 27 млн