Тёмный

NEC Code Practice Test Quiz 

Electrician Practice Test
Подписаться 17 тыс.
Просмотров 191 тыс.
50% 1

NEC Code Practice Test Quiz . This section consists of National Electric Code (NEC) Code Practice Questions. All the NEC Practice Tests are as per the NEC 2014 Code.
_____________________________­__
Please subscribe to update new videos:

Опубликовано:

 

15 янв 2016

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 78   
@DaironFrias
@DaironFrias 4 года назад
I like this video. It helped. It would be better if in the answers you put the article where we can find it !!!
@DPacVV
@DPacVV 6 лет назад
i took all 20 of these tests using my NEC book and they were a tremendous help in helping me get used to using the book and confirming answers. I took my low voltage test after using this for practice and even if all this info was way more than low voltage questions. I passed with ease. So thanks for having these on the line.
@joeljahnke9000
@joeljahnke9000 3 года назад
Question 15 is incorrect. Article 386.22 states adjustment factor shall not apply when ALL of the following conditions are met. If you are using this as review for your Inside Wireman Certification, understand, most of these questions are good, however they are pretty basic. Make sure you utilize more reputable online NEC practice tests like Dewalt. It also behoves you to study with material that tells you where in the NEC you will find the answer.
@michaelrose9556
@michaelrose9556 2 года назад
I highly recommended the KEY WORD INDEX by Tom Henry. It makes finding references in the code book much easier. Cheers and good luck to everyone.
@jesusnieves2175
@jesusnieves2175 6 лет назад
If possible use the 2014 NEC for your Real Exam if your test is still based on the 2014 NEC. My instructor told me that the NEC 2017 changes shouldn't affect passing the 2014 Exam, but one question could mean pass or fail. On some of these questions like the "Underground Wiring for Pools in Metal raceway" is no longer in the 2017. I spent a long time looking for it and couldn't find it, until I checked Ryan Chappell's code reference and yup Its no longer in there. Just a heads up.
@Lucio..
@Lucio.. 3 года назад
I think this is for someone that already knows how use the next code book ,is just to memorize the questions .
@noelalvarez98
@noelalvarez98 3 месяца назад
Thanks for the NEC TIPS.
@birtbernard
@birtbernard 10 месяцев назад
I got 21 right, I missed 3 for not taking my time, and 1 I just did not understand. I Passed Score with a 84%
@thechameleon77
@thechameleon77 8 лет назад
Great practicing tool. It would be great if you showed code sections though. Thanks!
@chadmellon4662
@chadmellon4662 5 лет назад
I believe you should be using the 60 degree column as it will be under 100A. Plus the double asterisk leads you to 240.4D (5) maximum over current device 20A
@foundfreemagna
@foundfreemagna 5 лет назад
All the same questions in this one, plus most of the NEC references www.electricianexampracticetests.com/nec-code/nec-code-practice-test-quiz-1/
@beeps7
@beeps7 5 лет назад
@@foundfreemagna Links for the 2014 manual, a little outdated.
@ajj1115
@ajj1115 6 лет назад
Question 6 is specific for dwelling units only, and also conf/meeting rooms per NEC 2017. No code requirements for general receptacles, in corporate, industrial etc.
@keving1774
@keving1774 6 лет назад
Anthony Jimenez great job, where is it in the code and what article?
@Toekneepowers
@Toekneepowers 6 лет назад
kevin g (2014 nec 210.52 A1) 210.52 through 210.64 applies only to residential. The question should have stated..... what is the spacing for dwelling units.
@cesarperez2216
@cesarperez2216 4 года назад
How does this help anybody trying to prepare for the NEC exam? It really doesn’t. It would be more helpful if you showed us how you picked the keywords in the question, how you searched for them, and ultimately, how and where found the answer. You are not expected to remember every thing in the NEC, but all journeymen and contractors and the students taking the exam are expected to understand and know how to navigate the book and find any of these answers in under two minutes. Add feedback to your videos, and you have a great educational video. The video itself is not helpful
@caymanisland20
@caymanisland20 7 лет назад
Thanks Ryan Chappell!
@escobarlopez14
@escobarlopez14 6 лет назад
I agree code ref. would be great to verify answers, Thanks!
@mellsmuts1433
@mellsmuts1433 4 года назад
Thank you.
@187mykel
@187mykel 6 лет назад
I wish the questions were like this on the Minnesota test it would be a lot easier
@sarhanhasan6324
@sarhanhasan6324 Год назад
Nice video
@ericanderson8606
@ericanderson8606 3 года назад
question 13 really makes your robot voice step and fetch!
@tlrmd4you
@tlrmd4you 6 лет назад
what aabout the telecommunication part? Any suggestions on preparing for this section? I am struggling with this...thank you
@abdelmou2140
@abdelmou2140 6 лет назад
Q 3 article 110.33 -A (3) PERSONNEL DOORS,
@dabiggcrunk
@dabiggcrunk 6 лет назад
Article 110.26 ( C )(3) Personnel Doors
@raulromano2029
@raulromano2029 7 лет назад
You raise me up
@arcticfunky621
@arcticfunky621 6 лет назад
question 3 article 110.26
@Rico702Vegas
@Rico702Vegas 3 года назад
ALL BUT 4 ANSWERS WERE "A".... AND MY 6YR OLD WAS THE ONE WHO NOTICED, AND HE DIDN'T WALK IN TO THE ROOM UNTIL QUESTION 20.
@bernardoprovenzanno9487
@bernardoprovenzanno9487 4 года назад
Lololol..amp perrys..😄😁👍👍
@CakTV
@CakTV 8 лет назад
เสียง สังเคราะห์ = Synthesis voice
@Michigan4Life1984
@Michigan4Life1984 6 лет назад
Whoa! What happened on question 13 and 15?
@anthonyt1316
@anthonyt1316 2 года назад
I would be completely lost had i lacked the spirits.
@DaironFrias
@DaironFrias 4 года назад
Where do i find the answer for question 16, ??? What I found in comercial garages is that is 4 hours for air change .........
@FirstnameLastname-vr3fn
@FirstnameLastname-vr3fn 4 года назад
Dude i cannot find this in the code book. If this is on the test most people will get it wrong unless they learned it from somewhere else.
@DaironFrias
@DaironFrias 4 года назад
Firstname Lastname thanks body, I learnt it like you said, failing the exam, because in NEC says that is 4 hours for air change. But it must be some where !!
@haroldglancy8872
@haroldglancy8872 3 года назад
@@FirstnameLastname-vr3fn 511.3 (3)a
@Toaster81
@Toaster81 3 года назад
Same here. 511.3(E)(1) states at a rate of 4' or more per hour. Could not find anything regarding a pit. I am using the 2017. If someone knows what article the 6' came from let me know
@Toaster81
@Toaster81 3 года назад
I did find mention of pit in the tables. I haven't done the calculation that's associated with it yet, but in the same table it does say 4hr.
@Toekneepowers
@Toekneepowers 6 лет назад
Question 6 is misleading,it should have stated what is the spacing in dwelling units. 2014 nec 210.52 through 210.64 only applies to dwelling units better known as residential. FYI code book term is dwelling unit not residential.
@MrUsmanghani0092
@MrUsmanghani0092 3 года назад
where i can get this access to this website
@arhodehamel2615
@arhodehamel2615 3 года назад
Little bit of a typo on questions 13 & 15
@davidgoossen113
@davidgoossen113 7 лет назад
when in doubt pick A.
@MR-nl8xr
@MR-nl8xr 7 лет назад
+dave. I hate your comment.
@arunkumar-mf8xs
@arunkumar-mf8xs Год назад
What’s the reference for question 14
@she3121
@she3121 6 лет назад
anybody help hanging emt conduit 3/4" on C-channel 41*41 mm 2 how many distance between the saddle and next saddle as per NEC
@tracyhawley2740
@tracyhawley2740 4 года назад
Do away with computer voice
@chef6150
@chef6150 4 года назад
where can you find number 25 and 24 in the nec?
@ericgandler2945
@ericgandler2945 Год назад
Your question is exactly why this video is not a good test prep. If you want to pass the exam, you should buy stallcups books.
@cmfrizzz
@cmfrizzz 5 лет назад
Question 6 is a joke. I guess your supposed to know it's by and outlet(another misleading word means doorway or passthrough) or another receptacle ? And that's how people flunk....
@LucifersDeathSquad
@LucifersDeathSquad 5 лет назад
Whys it a joke ? Its covered extensively in art. 210.52 of n.e.c. , just pay attention to exact wording.
@cristoferramirez3890
@cristoferramirez3890 5 лет назад
Anybody know where i can find qustion 8
@Shibsterr
@Shibsterr 5 лет назад
Article 220.12 General lighting loads by occupancy. Index, "lighting" ---"calculation of loads"
@rustygladden9781
@rustygladden9781 5 лет назад
Look at table 220.12 in the 2017 code
@ReformedTradesman
@ReformedTradesman 2 года назад
It would be better if you presented how you acquired your answers. It’s kind of pointless if you give your answer without showing how. That’s the entire point of learning to navigate the NEC.
@ericgandler2945
@ericgandler2945 Год назад
I agree. In fact I've taken multiple tests where you were required to cite the NEC code section.
@SuperVstech
@SuperVstech 6 лет назад
Question 9 is incorrect... either you need to state in residential breaker panel, or state nmc conductor... because the 75C rating for 12 copper is 25, and the 90C rating for 12 is 30 amps
@daveg.4862
@daveg.4862 5 лет назад
Question is clearly answered in 240.4(d)
@angeldjesusg
@angeldjesusg 2 года назад
It's not wrong. It's 20 amps(240.4(d)(5))
@embro4564
@embro4564 4 года назад
"must be rated not less than"---poor English jargon. "Should not be rated less than" Better. Why can't the "changes " in the code, include removal of the 1940 jargon cluttering it? As far as I'm concerned, that book, NEC ILLUSTRATED should BE the codebook. Just add in what's missing. Who make this hard? It's not like this has anything to do with the quality of the work a customer ends up getting.
@Mas0niq
@Mas0niq Год назад
Is this an AI voice? What the hell kind of accent is that?!
@embro4564
@embro4564 4 года назад
WIRES STRUNG OVER AN AMUSEMENT PARK RIDE?!? THAT RIGHT THERE SHOWs THE STUPIDITY of this. It would be more logical to have a mess of questions about rules in a hospital than a friggin ride!
@ericgandler2945
@ericgandler2945 Год назад
This is not a good video for test prep. This video fails to state what the code sections are with each answer. It is not "full answers." Many code exams require you to cite the code section along with the answer. And many exams are fill in the blank not multiple choice. If you want to pass the exam, I would highly recommend Stallcups Master Licensing Exam book. You will also need to purchase the answer book separately. If you need videos to pass, that is okay, but you should stick to industry vetted sources like Mike Holt.
@Toekneepowers
@Toekneepowers 6 лет назад
Question 9 is also misleading 😡 starting to think these quizzes are crap 💩
@daveg.4862
@daveg.4862 5 лет назад
Question is clearly answered in 240.4(d)
@RS-io6vm
@RS-io6vm 5 лет назад
In the world of modelling and marketing you don't use this book. This book is meaningless to you.
@oscarmoht
@oscarmoht 3 года назад
Not helpful
Далее
How To Use The NEC, NEC 2020, (29min:15sec)
29:15
Просмотров 157 тыс.
Test Taking Tips for your Electrical Journeyman Exam
10:28