Worcester Ri, Heat only boiler. Gas Valve Resistance test. Detailed Multimeter Fault Finding. 

F Raj
Подписаться 1,7 тыс.
Просмотров 955
50% 1

Опубликовано:

 

2 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 17   
@glennbarker222
@glennbarker222 9 месяцев назад
MegOhms, the top solenoid is open circuit.
@BoilerMend
@BoilerMend 9 месяцев назад
Yes
@prawnk1ng
@prawnk1ng 9 месяцев назад
What brand of silicone grease did you use for the O-rings?
@BoilerMend
@BoilerMend 9 месяцев назад
Molykote 111 Silicone Grease 100g tube www.ebay.co.uk/itm/256253244915?mkcid=16&mkevt=1&mkrid=711-127632-2357-0&ssspo=MVD6ImkuRU2&sssrc=4429486&ssuid=uwQ65NXJSK2&var=&widget_ver=artemis&media=COPY
@fbhooligan1907
@fbhooligan1907 9 месяцев назад
Thanks for the video mate. Just wanted to ask a question about pricing the jobs. Do you charge per hour or fix price? Like changing fan, pumps etc Many thanks
@BoilerMend
@BoilerMend 9 месяцев назад
Hi. I usually keep it, to a basic £100 Labor cost + parts, for one component replacement. If it's more components and not too much extra work on top, then add about £30-£40 on top, to keep it reasonable for the Customer 😇
@vandersarlok
@vandersarlok 9 месяцев назад
I love your video, very useful information for break down. Beside, Could you explain to us how/ where condensate water is formed inside a combi boiler?
@BoilerMend
@BoilerMend 9 месяцев назад
. Condensate starts from the flue. . As the flue is required to be installed, falling back to the boiler, it drains, through the main hx, into the condensate tray or pipe, beneath Or . in some models of boiler's and directly into the condensate tray, from flue, under the main hx, in some other boiler models, . further runs into the condensate trap and out of the white condensate drain pipe Eventually, running into a drain or final drain pipe, If installed correctly 👍
@tajmanara6552
@tajmanara6552 9 месяцев назад
Mr raj's videos are the best. You can learn from him as a new engineer, unlike others that seem ti just make videos
@BoilerMend
@BoilerMend 9 месяцев назад
Thanks very much 🫶🫶
@thebeneficiary
@thebeneficiary 7 месяцев назад
I have one of these and the blue light is not indicating a boiler fault…but boiler seems to struggle to start when I have the thermostat on auto settings, makes Klunk klink banging noises, noticed the pump flashing a lot as well but if I turn it off and put thermostat into continuous mode for both water and heat it starts up…is this an issue with the pump i have a grundfos one… I did drain the system and add some cleaner via header tank which has reduced the banging significantly. Would you know why this is happening?
@BoilerMend
@BoilerMend 6 месяцев назад
Sounds like an overheating issue. Maybe due to an intermittent fault on the pump or and faulty diverter valve maybe even a restriction in the system pupework
@BoilerMend
@BoilerMend 6 месяцев назад
*Pipework
@BoilerMend
@BoilerMend 6 месяцев назад
Or a possibility of air in system.
@thebeneficiary
@thebeneficiary 6 месяцев назад
@@BoilerMend Appreciate the reply, I changed the pump and it’s tripping the boiler lol think I bought a duff pump going to get it swapped for another tomorrow hopefully that will fix issue…
@NeoFreshair
@NeoFreshair 9 месяцев назад
I enjoy watching your videos! Very informative and detailed!
@BoilerMend
@BoilerMend 9 месяцев назад
So nice of you to say that 😌🫶
Далее
Учёные из Тринидад и Тобаго
00:23
OYUNCAK DİREKSİYON İLE ARABAYI SÜRDÜ 😱
00:16
Просмотров 4,4 млн
I Took An iPhone 16 From A POSTER! 😱📱 #shorts
00:18
Service Call | How To Diagnose A Bad Gas Valve
10:41
Просмотров 115 тыс.
How to check a Diverter Motor without a multimeter
3:38
The BEST Way TO Perform a Parasitic Draw Test
10:49
Просмотров 4,4 млн
Учёные из Тринидад и Тобаго
00:23