50% 1

Basic pressure switch triggered wiring for your air suspension compressors. Relay wiring diagram, for air compressor circuits.

Опубликовано:

 

26 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 42   
@EliteBussin
@EliteBussin Год назад
Nothing better than getting air management/compressor wiring tutorial from Jeff Goldblum
@gregoryhigh2751
@gregoryhigh2751 4 месяца назад
Great video! One question. There's 2 red wires going into the pressure switch on the one side... What's the second red wire?
@x2industries
@x2industries 4 месяца назад
This system has two compressors, so the second red wire activates a second relay which in turn powers the second compressor.
@louiet4905
@louiet4905 4 года назад
Thanks everything kicks on my system bags go up automatically but not by my switches my switches stop shooting air in my bags but my switch will fill up the bags then I turn it off with the kind of switch you have in your hand why my box switches not giving air to my bags
@indy007jones
@indy007jones 2 года назад
A rating of 30/40 means the relay can handle a load of 30 amps on the Normally closed contacts (30 to 87a) and 40 amps on the Normally Open contacts. (30 to 87). most compressors us 40 amp.
@x2salesdepartment662
@x2salesdepartment662 2 года назад
Thanks for the copy, we don't use the center closed circuit 30 amp pin for air suspension. Compressor pressure switch wiring only uses the 40 amp open side hence why we trim the center wire which I believe is 87a.
@cletoreyes9074
@cletoreyes9074 4 года назад
Bro thanks for the video,my compressor stop working I can not turn it on with the switch I have to connect direct to a battery what do you think it could be
@Pugsandhugs94
@Pugsandhugs94 4 года назад
Might be a bad relay or bad compressor.
@HiFiP
@HiFiP Год назад
if you have a second compressor do you need 2 reallays ? amd 2 complete set of those wire ?
@HiFiP
@HiFiP Год назад
just saw the image you posted bellow tks for that !
@x2industries
@x2industries Год назад
@@HiFiP you can use one relay if it is large enough to handle the current of two compressors. The main power line will also need to be able to handle 2 x the current.
@HiFiP
@HiFiP Год назад
@@x2industries yeah I saw that ! I watched a guy video and he was saying 80 amps should be good
@gingging3959
@gingging3959 2 года назад
So it’s 2 side of pressure switch rite ? 1 goes to relay RED 1 goes to the BATTERY ?????
@darionnguyen111
@darionnguyen111 3 года назад
I have everything wired up but i think i may have done something wrong. Once i hook up my battery the compressor turns on, even if my key isnt in the ignition
@x2salesdepartment662
@x2salesdepartment662 3 года назад
This is likely due to the pressure switch being wired directly to the battery instead of a keyed on connection... If you would like a dual compressor wiring diagram, you could check out the link below: www.x2industries.com/wp-content/uploads/woocommerce_uploads/2018/07/dual-compressor-circuit-wiring.jpg
@betmitler8747
@betmitler8747 4 года назад
The pin that goes into the air solenoid that controls the rear air level springs on my 2000 expedition broke off....how can I fix this
@x2salesdepartment662
@x2salesdepartment662 2 года назад
re pin it or solder direct temporarily and replace.
@El-Coco.0.
@El-Coco.0. Год назад
What wire gauge did you use for all this?
@x2industries
@x2industries Год назад
There are two diffrent gauge wires, the pressure switch circuit is a smaller 16 - 18 gauge and the compressor wire should be 8 - 10 gauge.
@x2industries
@x2industries 4 года назад
Does the relay click when connected to the pressure switch and good ground? In most cases the pressure switch goes bad, not usually the relay. You can test the relay by connecting 85 & 86 pins to +12 and ground (it should click) and turn on the compressor. It is not polarized so it does not matter which pins connect to which. This bypasses the pressure switch. Hope that helps.
@classic9147
@classic9147 4 года назад
My compressor stopped kicking on this morning it is connected to a switch first time I've owned a vehicle on air ride with a switch for the compressor I've always connected straight to the battery what could be the issue or how would I go about fixing it.
@x2industries
@x2industries 4 года назад
@@classic9147 have you tried to bypass the switch by tieing the two wires together? Does this switch connect to a pressure switch in the tank and then to a relay or is it just a switch in the circuit? To elevate any issues with the compressor, you can take a hot 12 volt lead and touch it to the power input on you compressor to see if it will power up, if not then it's most likely a worn out brush or armature in the compressor and likely need a new compressor.
@fozan9419
@fozan9419 2 года назад
I got questions sir. So I have 2 compressor 444valve.. So I need 2 relay right? The question is what are suggest, do I have to take 2 cable to the battery from every relay. Or i can just use fuse 60 amp 2 way and then 1 cable to the battery Hope ur answer I'm struggling with this two things Sorry for the bad English I'm trying my best🙏
@x2industries
@x2industries 2 года назад
Hello, you can do either way. If you want to use a larger 4 or 6 gauge wire and split off then that is ok,. It is also OK to run 2 separate power wires. If you are using two compressors then two relays would be needed.
@x2industries
@x2industries 2 года назад
www.x2industries.com/wp-content/uploads/woocommerce_uploads/2018/07/dual-compressor-circuit-wiring.jpg
@harrywalker5836
@harrywalker5836 Год назад
@@x2industries very confusing.the pressure switch turns the power on & off to fill the tanks,bags,diff. why you need a manual switch.?.my comp needs to be on,all the time, the pressure switch controls when on/off. i need a relay so it doesnt burn out, like the last 5,. this vid does not show or help..i have 3 tanks, 15 gallon, for tires ect. a power tank would be better, but illegal in aus..stupid..
@x2salesdepartment662
@x2salesdepartment662 Год назад
@@harrywalker5836 here is the wiring diagram if that helps: www.x2industries.com/wp-content/uploads/woocommerce_uploads/2018/07/dual-compressor-circuit-wiring.jpg
@yahama4life
@yahama4life Год назад
The wire that runs to the compressor will be pos correct
@x2industries
@x2industries Год назад
Yes, a positive will run from battery to relay then to your compressor.
@stirfry59
@stirfry59 2 года назад
Where can I get this relay
@x2industries
@x2industries 2 года назад
www.x2industries.com/product/40amp-heavy-duty-relay/ If you need it quick you should be able to pickup a standard 40 amp relay from a local auto parts store. Use one relay per compressor so you don't over draw your relay circuit amperage.
@streetclasscc5189
@streetclasscc5189 Год назад
what happen if you dont use a pressure switch?
@x2industries
@x2industries Год назад
Comps would stay running.. it's just an on and off pressure sensor.
@streetclasscc5189
@streetclasscc5189 Год назад
@@x2industries would the compressors get burned up if your going over the maximun psi (200psi)
@x2industries
@x2industries Год назад
@@streetclasscc5189 they will not burn up immediately, it will be pushing the compressors max pressure / duty cycle which means if ran at that rate for too long can and will cause the compressors to generate too much heat which in turn will compromise the output and or cause premature failure.
@moneymay1062
@moneymay1062 4 года назад
What size is the breaker
@x2industries
@x2industries 4 года назад
It depends on the compressor, we include a 30-40 amp for initial turn on spike amperage. You should be good with the same type of rating in a fuse as well.
@moneymay1062
@moneymay1062 4 года назад
Im running a single fire stone compressor for airbags.
@x2industries
@x2industries 4 года назад
@@moneymay1062 should only need 30 amps or so..
@x2industries
@x2industries 4 года назад
They are usually 15 to 20 amp consistent, so 30amps should cover the cold start spike.
@rogersolis6903
@rogersolis6903 3 года назад
This is a confusing video to be honest. I’m wiring one of your systems and I’m working with two relays. The install of the hardware is easy it’s all the wiring that’s so confusing with your system. Oh yeah that’s me asking for help. Thanks.
@x2industries
@x2industries 3 года назад
Sorry about that.. This document may help a bit more.. www.x2industries.com/wp-content/uploads/woocommerce_uploads/2018/07/dual-compressor-circuit-wiring.jpg
Далее
How to wire compressors for your Air Bag Suspension
11:23
WILL IT BURST?
00:31
Просмотров 17 млн
Install of a Ebay Air Ride System
17:12
Просмотров 50 тыс.
Unboxing The Cheapest Air Bag Suspension I Could Find
12:54
Understanding Compressor Wiring
10:59
Просмотров 434 тыс.
Evolve Dual Compressor Wiring Kit Instructions
19:39
Просмотров 13 тыс.
How to Plumb a Remote Switch for your 4WD Air Bags
9:41
AIR SUSPENSION: PART1 - SOLENOID SETUP
19:16
Просмотров 39 тыс.