In this video I try a new way to replace a reversing valve. Hope you enjoy. #hvac #hvactechnician #fieldpiece #hvacguy #hvaclife #hvactech #acrepair #hvacinstall #milwaukeetools #trane #heatpump #reversingvalve
Merch Store : hvac-guy-2.cre...
HVAC LIFE FB Group: / 521086622906115
Here are links to the tools I use, And it costs you nothing extra to buy from this list:
Inficon D-Tek Stratus: amzn.to/3RvnXOl
Fielpiece SC680 Clamp Meter: amzn.to/33rhxvE
Fieldpiece SC480 Clamp Meter: amzn.to/33kfgCB
Fieldpiece SMAN 480 Digital Manifold: amzn.to/3twfVvA
Fildpiece SVG3 Vacuum Gauge: amzn.to/3udursu
Fieldpiece DR58 Leak Detector: amzn.to/3nt1TXw
Fieldpiece JL3KM2 Bluetooth Manometer set: amzn.to/3blMrJR
Fieldpiece Blutooth Scale: amzn.to/3Gzveab
Fieldpiece SDMN6 Manometer: amzn.to/3qwk9RP
Fieldpiece MR45 Recovery Machine: amzn.to/3cUFX5h
Fieldpiece 8CFM VP87 Vacuum Pump: amzn.to/3qC2wA2
Yellow Jacket Tubing Expander: amzn.to/3sjuK3a
Milwaukee M12 Impact Driver: amzn.to/37xXkqk
Makita XDT16: amzn.to/3riXuaJ
Makita 18V Light: amzn.to/3Fw4GW4
Makita Wet/Dry Vacuum : amzn.to/3tw4dAL
Makita 18V Battery Mounts in Van : amzn.to/3GxpVID
Makita Jobsite Radio: amzn.to/3HuVp2u
DIY Vacuum Attachment for drains: amzn.to/3tDpfNU
Fieldpiece Smart Probe Kit : amzn.to/34NG3HL
Klein Heavy Duty Wire Strippers : amzn.to/3I8YNzT
Klein Needle Nose Crimpers/Stippers: amzn.to/3fuwXlw
Klein Knee Pad: amzn.to/3cy6FB0
Klein 7in1 Flip Socket: amzn.to/3bpabwG
Klein Journeyman Pliers: amzn.to/3tvB60w
Milwaukee Slim Packout On My Torch: amzn.to/3KeLm3j
Aluminum Packout Wall Mount on torches : amzn.to/3Kf9hQg
Milwaukee Tool Box: amzn.to/322iyK9
Veto Pro Pac Tech MCT: amzn.to/3nwwQdA
Milwaukee Hook Blade Knife: amzn.to/33F3m5T
Testo 300 flue gas analyzer: amzn.to/3IcS3Bd
Western Nitrogen Regulator: amzn.to/3rmdKrx
Klein Canvas Bucket: amzn.to/3FyzKVf
Flag Velcro Patch Kit: amzn.to/3K8Eswx
Supco Magnetic Door Switch Holder: amzn.to/34IcXcL
Milwaukee Magnetic Light: amzn.to/3FulCfF
Milwaukee Rechargeable Headlamp: amzn.to/3nuXsvf
SS2 Float Switch: amzn.to/3K7LJMW
3-Amp Breaker: amzn.to/3nxaSXJ
Appion Valve Core Removal Tool: amzn.to/33CFArw
Appion G5 Twin Recovery Machine: amzn.to/33Dvd6C
Yellow Jacket Large Tubing Bender: amzn.to/3qwJv1U
Similar Small Tubing Bender: amzn.to/3fJsziJ
Fluke Twist Guard Test Leads: amzn.to/3216R6j
Fluke 975 Air Meter: amzn.to/3GwD9oM
Honeywell T-4, 2-Heat, 1-Cool Programmable Thermostat: amzn.to/3qtIuaX
Kidde Carbon Monoxide Alarm: amzn.to/3qtIIyP
SolderWeld Flame Resistant Magnetic Blanket: amzn.to/3qtJ4Wb
Malco 1/4 - 5/16 flip bit : amzn.to/3nr67yU
Quick Check Acid Test: amzn.to/3GA2XAy
Aims Power Inverter: amzn.to/3qOSc87
Wiha Torqe Screwdriver : amzn.to/3u1swH6
Wiha Torqe Screwdriver 1/4” adapter: amzn.to/3IH22Pw
American Flag Gator : amzn.to/3rKBl5u
Compressor Tote: amzn.to/3H8xHst
Inspection Mirror: amzn.to/3r9PERV
Wiha TorqueVario-S 10-50 in/lb Torque Screwdriver : amzn.to/3GbKAku
1/4” adapter for Wiha Torque Screwdriver : amzn.to/3u8g0pq

Опубликовано:

 

11 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 84   
@jesusdisciple7343
@jesusdisciple7343 Год назад
Hey Curtis my name is Oscar I own an ac company here in Houston TX. Thats the space where a Captain Hook tip comes handy.
@jsundevil1
@jsundevil1 Год назад
Just found out my reversing valve went out on a 2 year old unit. Tech was telling me it’s one of the worst repairs to do and now I see why. Cheers to you HVAC techs who bust ass and do things the right way
@bigdaddy5948
@bigdaddy5948 Год назад
Yeah. Getting the compressor out might have been easier. Tough job
@phillipjoy1305
@phillipjoy1305 Год назад
You should try a rosebud tip to unsolder those fittings.Great videos 😊
@amersingh2557
@amersingh2557 Год назад
Great job. Your workmanship is perfect. That was a tough one to weld.
@MariosACandRefrigeration
@MariosACandRefrigeration Год назад
The sawsall made the difference,great job.
@benkuxhouse787
@benkuxhouse787 Год назад
That was a real tight job. I’ve done that a whole bunch of times cutting out reversing valves and then unsoldering them. I’m surprised by how a few people use turbo torches I have 1 with all the tips. I love the way the heat goes around the pipe with the turbo torch especially in a tight spot. I am also surprised you were able to do that with silphos instead of the silver bearing solder with the flux that I’ve always had use for a reversing valve.
@cutzwithrazzor
@cutzwithrazzor Год назад
I love my turbo torch! I do mostly residential compressor jobs. That almost looks like it would of been easier to just take out the compressor.
@benkuxhouse787
@benkuxhouse787 Год назад
@@cutzwithrazzor I’m surprise he was able to make those welds with silphos. I had a really tight job very summer to this on a water source two-stage heat pump with two compressors. I had to remove 1 compressor to access the reversing valve and was still very difficult. I soldered on tips so I could pressurize the system before I put the compressor back. I’ve cut out reverse calves before with a saws all that’s what I’ve done many times. You would think that Trane could’ve come up with a better idea than this. If the back panel was removable, you could take the blower out remove the panel and then reversing valve would be right there. I don’t think that is removable I think it is all one piece and you’d have to disassemble the whole unit. It’s a job I wouldn’t want to have to do I hope I never have to I am in a school district job now we don’t have any units like that
@Bryan-Hensley
@Bryan-Hensley Год назад
I bet I've changed 10 expansion valves on those Trane package units. I usually replace reversing valves at the joints further out if possible, like the factory installed them.
@c_young-hvac4586
@c_young-hvac4586 Год назад
I use an old pair of green tin snips to cut the pipe below the solder joint and the un solder of course . I like to pull the compressor ...but you handled it like you wanted to and I say to each their own as long as the results are the same
@jthonn
@jthonn Год назад
Great job! Tight little area to braze in. I thought you were going to pull the compressor so you could get at it, but you pulled it off.
@biblebloopers946
@biblebloopers946 Год назад
I just did a reversing valve a few months ago exactly like this. Cut it out with a sawzall
@joshuat2751
@joshuat2751 Год назад
nothing i hate more than seeing a dispatch to replace a damn reversing valve... especially in water sourced heat pumps in condos.
@donnyjackson1908
@donnyjackson1908 Год назад
Tough job. Definitely one you do first thing and keep the day open to give yourself plenty of time.
@williamserver4332
@williamserver4332 Год назад
That looked like a tough one for sure. Great video
@DanO181919
@DanO181919 Год назад
Been waiting for this one.
@kg4muc
@kg4muc Год назад
That valve was in a mean location to braze! Yanking the compressor out might have made a little more easy to braze. But a nice job for sure
@harrygilbert4593
@harrygilbert4593 Год назад
Why not pull the compressor. So much blind brazing. Had me watching till the end to see the repair swooshed.Nice work.
@kylegreene1583
@kylegreene1583 Год назад
Even though the compressor was in the way, good job.
@michelgrenier1878
@michelgrenier1878 Год назад
Excellent job on that valve replacement ; They are such a pain to replace !
@guybonin8050
@guybonin8050 Год назад
Looks like it may have been quicker and easier taking the compressor out. But I know at the time you’re thinking a 50/50 shot.
@johnwalker890
@johnwalker890 Год назад
Good job Curtis.
@michigantrapper5687
@michigantrapper5687 Год назад
I need a T shirt that says I'm the guy your wife calls when she gets hot..🤣🤣😎👍
@JamesBrown-db9pk
@JamesBrown-db9pk Год назад
call biden jill will take u over poopy pants
@stephenbullock1443
@stephenbullock1443 Год назад
Great work Curtis.those reversing valves can be difficult to braze in with out melting the nylon inner piston sleeve
@juncusbufonius
@juncusbufonius Год назад
Ha BigClive demonstrated on of those schrader valve tools a few days ago. And now I've seen it on the front line. Neat.
@tonydelgrego2906
@tonydelgrego2906 Год назад
Nice professional repair
@jaymz0074
@jaymz0074 Год назад
Good Job and another great video.
@raytinsman2672
@raytinsman2672 Год назад
Best way I found is to braze the discharge, then position a hose and secure it, to put a layer of water on the body, then braze all the other lines. Valve never gets even warm
@mikemalone6103
@mikemalone6103 Год назад
Great work but I can’t believe you didn’t remove the compressor, that job would have been sooooooo much easier.😂
@tonykillingsworth9247
@tonykillingsworth9247 Год назад
It's gonna cost them but I turn the compressor around so the valve is out and re pipe everything accordingly ...next guy has a much better day !
@hinspect
@hinspect Год назад
Great video👍 I looked at an American Standard package unit like that about 12 years or so ago. I believe they were made by the same company. That looked like a pain to do, looks like it turned out great😀🇺🇸
@EastDallasKicks
@EastDallasKicks Год назад
You like American standard? Quality good? Fun to work on?
@MegaDysart
@MegaDysart Год назад
Trane owns American standard, or maybe the other way around. Pretty sure it's been that way since the early 2000s maybe even longer. They were both owned by Ingersoll Rand up until a few years ago. Same company that owns bobcat and a few other major companies
@JamesBrown-db9pk
@JamesBrown-db9pk Год назад
all that heat fr torchin keep u warm
@sergiohernandez4163
@sergiohernandez4163 Год назад
That's one thing I have done yet changed reversing valve.. I fixed a hole on one once. I was lucky that I fixed it or wise I had to change it.
@Mapdotgolf
@Mapdotgolf Год назад
I always sweat mine out and wouldn’t you be worried about shaving getting in the copper when using a saw ?
@miguelperdomo786
@miguelperdomo786 Год назад
He cut the top not the bottom
@douglaskahane141
@douglaskahane141 Год назад
Nice. Lots of work.
@germanlopez7506
@germanlopez7506 3 месяца назад
bent the reversing valve top- pipes with pliers then cut them with the metal cutter plier.. unsolder the Rvalve
@carlsousa7382
@carlsousa7382 Год назад
I have a wall mount heat pump that is going off on high head pressure only in heat. It works fine in cooling but the suction is a little low. Do you think it is the reversing valve or expansion valve at the outdoor or maybe plugged orfice at indoor coil? Love watching your trouble shooting skills and the way you don't get frustrated when things go wrong.
@timrob0420
@timrob0420 Год назад
Call a reputable technician to diagnose it. Nobody can diagnose something off youtube comments section lol
@douglaskahane141
@douglaskahane141 Год назад
Use an expander just a little to make the lines easier to go in.
@uratruffatore
@uratruffatore Год назад
Dude...cut the tag out of your left glove...I promise the mattress police won't come and get you...lmao
@timrob0420
@timrob0420 Год назад
Reversal valve is definitely the hardest repair on a heat pump
@imwojo
@imwojo Год назад
Put some metal tape over the scorched area will look just fine.
@mortalfoolproductions
@mortalfoolproductions Год назад
Can I replace my Trane 2 ton reversing valve with a 3 ton valve? Thanks for the great video
@artwalters6871
@artwalters6871 Год назад
reversing valves are a pain no matter how you do them.
@roywright5485
@roywright5485 Год назад
If the copper pipe is heated properly, shouldn’t the capillary action of the soldering suck the solder around to the backside of the joint? And I’m assuming the flax is in solder rods?
@chaneystarnes1959
@chaneystarnes1959 Год назад
If you would cut your video length in half, I believe you could double your viewership. I love your videos. But I can’t invest 35 minutes per day watching them. Just some friendly advice.
@HVACGUY
@HVACGUY Год назад
I try when I can. Kinda hard to do on this one.
@benlund3905
@benlund3905 Год назад
@@HVACGUY I definitely like the meal deal. Want to see it all. If its 10 min I usually dont bother. Liking your videos more and more.
@carlostapper87
@carlostapper87 Год назад
@@HVACGUY We like the long videos... From beginning to end 👍
@MegaDysart
@MegaDysart Год назад
Idk man the HVACR VIDEOS channel has lots of 35+ minute long videos and I'm freaking glued to both channels. He has a few hundred thousand subs. I think Curtis is doing really well in the sub count area. A little more fine tuning with video titles and thumbnails and he's gonna take off.
@dougellis2736
@dougellis2736 Год назад
Shame on Trane for locating 4 way in that location.
@JoseSantiago-wp8uw
@JoseSantiago-wp8uw Год назад
😎
@jamesfitzsimmons381
@jamesfitzsimmons381 Год назад
Sorry for the Monday morning quarterback comment . I think it would have made it easier on you by taking the compressor out
@HVACGUY
@HVACGUY Год назад
I agree
@jamesfitzsimmons381
@jamesfitzsimmons381 Год назад
@@HVACGUY I still think you did a great job
@drodriguez394
@drodriguez394 Год назад
Your flame runs in your torch tip because as I commented before.. you aren’t running a good ratio.
@drodriguez394
@drodriguez394 Год назад
Don’t take that as hate I still love the content !! The only thing I hate is how you run your torches 🤣 thanks for taking the time to share.
@tphvac87
@tphvac87 Год назад
What’s the model number of that unit got a trane class coming up wanna ask why they put it there? That’s a terrible location for that valve man!
@HVACGUY
@HVACGUY Год назад
4WCY4030A100BA
@Silky_boi
@Silky_boi Год назад
Trane package units just suck period! Reversing valve in a horrible spot, and they make the damn units so unnecessarily wide and offset the duct terminations to the left so 90% of existing plenums never fit. The engineer who designed this is a jackass to say the least.
@tphvac87
@tphvac87 Год назад
@@HVACGUY thanks
@HVACOG
@HVACOG Год назад
Pain in the ass job. AS doesn’t make it easy on us. Just like stuffing the the txv cooling txv behind the blower
@mypindiwala
@mypindiwala Год назад
How many hours for this from start to finish?
@HVACGUY
@HVACGUY Год назад
3
@Empty7775
@Empty7775 Год назад
How do you know that a reversing valve is bad? How did you diagnose that?
@fernandofhernandez899
@fernandofhernandez899 Год назад
i guess good calibrated thermocouples will tell you if the valve piston is stucked or not closing all the way
@HVACGUY
@HVACGUY Год назад
This one was leaking
@Empty7775
@Empty7775 Год назад
@@HVACGUY thanks
@Sctronic209
@Sctronic209 Год назад
I would take the compressor out.
@christopherscott8853
@christopherscott8853 Год назад
So much wrong here.
@alexandermcdougall8313
@alexandermcdougall8313 Год назад
Tell you what I'd do .. remove the panel to your left and go thru the back panel.
@robertpeters9438
@robertpeters9438 Год назад
I still think you should not use a saw. I give this episode thumbs down for that reason. Get a mini pipe cutter please.
@michaelazuela
@michaelazuela Год назад
Send him one
@HVACGUY
@HVACGUY Год назад
I used a pipe cutter on the bottom. But, the top I figured shavings will fall into valve and not a big worry. Those were my thoughts
@jcbecker2800
@jcbecker2800 Год назад
I install Trane. That RV location sucks.
@robertwood9628
@robertwood9628 Год назад
Easier in this case to remove the compressor...period.
@dougellis2736
@dougellis2736 Год назад
Shame for that location.
@bonexsher
@bonexsher Год назад
what a PAIN IN THE ASS..
Далее
Heat Pump 03 Reversing valve
21:04
Просмотров 32 тыс.
Decompress small game, have time to play it!
00:35
An Unusual No Cooling Call
22:56
Просмотров 161 тыс.
Heat Pump Out on Low Pressure - Pumping Down
31:38
Просмотров 14 тыс.
Thermostat Was Just the First Problem I Found
24:43
Просмотров 18 тыс.