Тёмный
No video :(

Condenser fan blade placement is critical 

Michigan Heating Guy
Подписаться 20 тыс.
Просмотров 54 тыс.
50% 1

Condenser fan blade placement is critical. Have to make sure the air is blowing out of the top of the condenser not through the top part of the coil.
Get it on amazon
1/6 HP Condenser Fan Motor 1075RPM. amzn.to/2NAH0r0
1/4HP Condenser Fan Motor, 1075RPM amzn.to/3i7Rzjm
1/6-1/3HP Condenser Fan Motor 1075RPM amzn.to/3eE4xU3
Milwaukee 48-22-6330 Tongue and Groove Pliers Set
amzn.to/3kfch0R
GoPro Hero 8 Black Action Camera with Accessory Bundle
amzn.to/34AGamf
Veto Pro Pac Tech XL Tool Bag
amzn.to/2U1QqPF
OLIGHT Bundle H2R LED Headlamp, 2300 Lumens Rechargeable Flashlight
amzn.to/370rGiq
Amprobe AMP-320 Clamp Meter
amzn.to/2GNxUHe
Fluke 117 Electricians True RMS Multimeter
amzn.to/3iFZP9t
Milwaukee 2364-20 M12 Rover
amzn.to/2HNvitK
Milwaukee Rocket light 2132-20
amzn.to/341OTPm www.amazon.com/shop/miheatingguy
Milwaukee 2131-20 M18 ROCKET Dual Power Tower Light
amzn.to/3pe2hYH
Milwaukee M12 Surge Hydraulic Driver Kit 2551-22
amzn.to/3n5offb
Makita E-01563 Impact XPS 3 Pc. 6" Magnetic Nut setter Set
amzn.to/2JdAcku
Milwaukee 48-22-6330 Tongue and Groove Pliers Set
amzn.to/3kfch0R
GoPro Hero 8 Black Action Camera with Accessory Bundle
amzn.to/34AGamf
Veto Pro Pac Tech XL Tool Bag
amzn.to/2U1QqPF
OLIGHT Bundle H2R LED Headlamp, 2300 Lumens Rechargeable Flashlight
amzn.to/370rGiq
Amprobe AMP-320 Clamp Meter
amzn.to/2GNxUHe
Fluke 117 Electricians True RMS Multimeter
amzn.to/3iFZP9t
Milwaukee 2364-20 M12 Rover
amzn.to/2HNvitK
Milwaukee Rocket light 2132-20
amzn.to/341OTPm
#MIHeatingGuy

Опубликовано:

 

27 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 51   
@acconboy
@acconboy Год назад
I just did this today on mine. Replaced the fan motor last year and only option was a full sized motor. Looked like the blade was nearly 3 inches below the lip at the top of the unit. Figured that couldn't be good for airflow so wen out, cut the motor body mount bolts down to a couple threads above the nuts, set the fan blade as close as I could get it to the motor body on the shaft and still clear and holy crap - the noise level cut by almost half and the airflow more than doubled coming out the top. Big difference! - can't believe I missed that on assembly but live and learn.
@prmayner
@prmayner 4 дня назад
I did the same thing, I put the fan blade at the end of the shaft and jees did it make a hell of a racket you could here it down the street I left it that way till the next day to the thank you's of my neighbors. the next day I cut the bolts that hold the motor till just a few threads were left and slid the fan blade toward the motor and what a difference. That was 4 years ago and now I'm starting to get a rumble moan so I'm going to go back in there and see if I can fix that.
@prmayner
@prmayner 4 дня назад
Well i could only go about another 3/8" but that made the difference, no more noise. Thanks man.
@acconboy
@acconboy 4 дня назад
@@prmayner happy to help
@TheLarryBrown
@TheLarryBrown 5 лет назад
I learned a lot. I learned fancy test equipment is available to see how your unit is running. I learned that lower head pressure, whatever that is, is better. I learned that the fan blade needs to be located properly, and I learned raising the fan blade up higher on the shaft makes it work better. That's a lot, so thank you.
@Jeff_S...
@Jeff_S... 7 лет назад
Amazing that there is a guy in your area so clueless to basic physics and aerodynamics, that keeps placing fans that low in the coil. Thanks for your videos, they are so realistic to field work.
@MiHeatingGuy
@MiHeatingGuy 7 лет назад
+Jeff S hey thanks for your comments I really appreciate them keep watching thank you
@scrambler350
@scrambler350 7 лет назад
I do my best to get a measurement from the fan grill to the hub BEFORE pulling the bad CFM off, then get it as close as I can to that same distance when I install the new one - I figure it was manufactured with the fan blade at the optimal position. If I forget, I just try and get it as high on the shaft as I can with it still clearing the bottom of the motor.
@markleise3749
@markleise3749 11 месяцев назад
The fan needs to be closer to the top also so that it can pull the air more efficiently through the cooling fins and coil. In order to achieve proper cooling.
@MatthewWatches
@MatthewWatches 18 дней назад
Is there ever a reason to lower it or should you always have it up higher? Why is it adjustable
@erickbravo5800
@erickbravo5800 Год назад
Yup, I killed a motor within 2 days by installing the blade leveled to the bottom of the exit. Blade needs to go at least an inch or two above the bottom exit level.
@aircooledtx
@aircooledtx 7 лет назад
Good video, Lennox had re-call on fan shroud , was told to remove it.2001-2005 Will stop noise too.
@MiHeatingGuy
@MiHeatingGuy 7 лет назад
+Michael Lee Mike that's good information I will have to check into that I was not aware of that thanks for your support keep on watching
@throttlebottle5906
@throttlebottle5906 7 лет назад
whiiirrrrrrrrrrrrr
@airmechanical7163
@airmechanical7163 7 лет назад
Very good demostration!
@NorCal-refrigeration
@NorCal-refrigeration 7 лет назад
Enjoyed the demo. I think a UFO got in there. Lol
@manfredman5075
@manfredman5075 4 года назад
Surprised the subcooling did not go up with higher blade placement.
@andresmurillo5117
@andresmurillo5117 2 года назад
Do you check the amp in the motor if there is any difference in the location of the blade? Thank you Very good video..
@LucindaGaskill-zv3hk
@LucindaGaskill-zv3hk 4 дня назад
I replaced the fan blade but now the unit won’t start.
@bronxlords
@bronxlords Месяц назад
How do you know what size
@leoashrae4199
@leoashrae4199 7 лет назад
Thanks for doing the demo. Some really good information here.
@MiHeatingGuy
@MiHeatingGuy 7 лет назад
+LEO ASHRAE hope I could help thanks for watching
@ThattfooRichie
@ThattfooRichie Месяц назад
I have a question is the fan blades supposed to blow up and out or downwards and in? I think I installed my blades the wrong direction but not sure
@MiHeatingGuy
@MiHeatingGuy Месяц назад
Up
@ThattfooRichie
@ThattfooRichie Месяц назад
@@MiHeatingGuy thanks I actually had it the right way found out it was a leak from the fan blades flying off and hitting the side coils inside, gonna have to get a whole new unit.
@dh5594
@dh5594 2 года назад
You never even said weather it was better or worse for a layman to know 🙄
@jhhvacplumbing1944
@jhhvacplumbing1944 7 лет назад
nice little demo , very important
@TheRealJRC
@TheRealJRC 5 лет назад
It is unbelievable how many people out there work in HVAC and don't have a clue what they are doing. I bet the homeowner is much happier with performance and I guarantee the system will experience more durability as a result.
@TheHonorableMrPedro
@TheHonorableMrPedro 6 лет назад
Good video, it answered a big question I had 👍
@alfredomontoya8466
@alfredomontoya8466 7 лет назад
Great video, thanks. Were you able to address the loud noise after adjusting the fan blade? You mentioned that it may be the fan blade hub. Is that what it was? My unit just started making this exact same noise this morning.. loud!
@SodaStereo1984
@SodaStereo1984 6 лет назад
What application are you using on your tablet to measure the head pressure?
@NordicDan
@NordicDan 4 года назад
The fan on my unit sits almost a quarter of the way down the height of the coil, but is still set as close as possible to the motor housing. Motor was replaced several years ago (by a dope who didn't know what he was using and banged the hell out of the inside of the coil) while my ex wife was living in my house during our divorce. Only way I have to raise the blades would be to raise the entire grille & motor assembly using some sort of spacers oe bezel, but that would mean several inches. Would that even be advisable?
@MiHeatingGuy
@MiHeatingGuy 4 года назад
Sounds like the wrong motor
@NordicDan
@NordicDan 4 года назад
@@MiHeatingGuy I had wondered that. The top of the housing is only an inch higher than the top of the coil though as well, so would a shorter motor do much if it's only raising the fan an inch or so higher? I did finally give my coil an extensive cleaning a few days ago and that lowered the air temperature in my ducts just a hair more than 5 degrees, which makes a BIG difference.
@RobHVAC
@RobHVAC 7 лет назад
Nice experiment
@Sctronic209
@Sctronic209 4 года назад
Great info.
@mikewilliams7330
@mikewilliams7330 5 лет назад
Amazing video now I can fix my moms.
@bnappi22
@bnappi22 6 лет назад
Looking down should the fan turn clockwise or counterclockwise?
@tony37068
@tony37068 4 месяца назад
It can be either CW or CCW, depends on brand and factory setup. I have 2 units, one is CW and the other is CCW. The blades on the two are bending in opposite direction, so both pull air upward. One day one motor was broken, I swapped the motor, found out that. It is not a big deal as you can swith the dirction easily.
@throttlebottle5906
@throttlebottle5906 7 лет назад
unsure if they do it because they don't know better or a mix of dont care/job assurance/making future sales the bad way, so it works poorly/cooks, then they can sell a new unit :|
@bookooc5605
@bookooc5605 6 лет назад
Thanks for the video. I just replaced a motor and the fan on a 13 year old Goodman. It is shaking the grills in front like crazy. I put it at the same position as the old motor and fan. If If press gently on any point of the top where the motor mounts, it stops. This is the 2nd fan, the first was bent out of the box. Any ideas?
@hey.hombre
@hey.hombre 4 года назад
I'm not an expert since I'm having issues too. I replaced a condenser fan motor and it's vibrating. Another guy said that the four mounting screws on top might be over tightened. And yes it could be one of the fan blades could be tweaked. Here's the youtube link. I hope it helps. I hope it helps me too. ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-QSDUkmoebYs.html
@johnisraelhvac2019
@johnisraelhvac2019 7 лет назад
Great video brother
@MiHeatingGuy
@MiHeatingGuy 7 лет назад
+Israelhvac thanks john
@TheLarryBrown
@TheLarryBrown 5 лет назад
Maybe you think we should already know all that, but you're here to teach, right? I have no knowledge, but let me just make something up: The purpose of the fan is to pull cool outside air into the center of the unit, cooling the condensor coils by drawing the air past them. If the fan is too low in the unit, the highest coils on the unit are not cooled in this fashion. Even worse, as the air is passed over the lower coils it gets heated, and then this hot air is "blown" by the fan past the higher coils, not giving them the cooling that is desired. The result is the condensor working at only 66% of what it could, obviously a disaster. The lesson is to locate the fan blade as high as possible on the motor shaft with out having anything interfere with the fan blade.
@TheLarryBrown
@TheLarryBrown 5 лет назад
However, how about some theory? What is head pressure? Why is lower better? Can it ever be too low? Is lower always better? How does moving the fan blade higher make it work better? Should you always make the fan blade as high as possible? Or is it not that simple?
@danielfranklin9062
@danielfranklin9062 4 года назад
I'm going to take a stab at answering some of these questions. "Head pressure" is another term for high side pressure or discharge pressure. That being said, if your head pressure is near your low side pressure, you are either low on refrigerant or you might have a problem with your compressor, so, yes, it can be too low, so lower isn't always better. In this case, lower is better because 182 psi means the system is running much less efficient than at 162 psi. How does that work? Well, pressure builds up heat and heat builds up pressure, the point of the condenser fan is to force air through the condenser coil to dissipate heat. Here's a quick demonstration of why the fan dissipates more heat when blade is located closer to the top: Blow on your hand from 1 inch away. Now blow on your hand from 1 foot away. Now, hold your hand as far away from your face as you can and try again. The further away your hand is, the less force you'll feel and the more air flow is lost in other directions. By moving the fan blade as close to the grill as possible, you are forcing ALL of the air to be forced in that direction, and with all of that air coming from outside of the condenser through the condenser coils, thereby dissipating more heat and lowering the head pressure. There might be designs in which placing the blade closer might not be the most optimal, but for a general idea, this is roughly where it should be.
@TheLarryBrown
@TheLarryBrown 2 года назад
@@danielfranklin9062 Hey ! You got a love heart from the video author. I'll take that as his endorsement of the accuracy of what you wrote.
@gonzgarr1592
@gonzgarr1592 7 лет назад
nice info
@brianellsworth4767
@brianellsworth4767 4 года назад
I had the same problem today. I am the culprit who replaced the motor last year. There was only one supply house open at 5 pm and they didn't have the right motor . The replacement motor was longer than the original and the fan blade was set to deep below the shroud . Again they called me at 5 pm and the compressor was tripping the internal over loads. I went to the depot and bought pvc couplings that were an inch and a half long. Using long screws I mounted the grill higher up and the fan blade position was close to the original setting .No kid can stick their fingers in deep enough to get close to the spinning blade . When the heater breaks customers will wait . When the AC breaks they have no patience on a 90 plus day. Butchery happens when things get desperate and you worry about their comfort. Don't be like me. Use the right parts or don't fix it. I' going to check the unit again if the weather gets hot and replace the capacitor. 16 year old r22 unit
Далее
Музыкальные пародии
00:28
Просмотров 22 тыс.
ФОТОГРАФИЯ ЦЕНОЙ ЖИЗНИ
32:38
Просмотров 1,7 млн
No Cooling/Goodman Fan Blade
10:55
Просмотров 3,8 тыс.
How to fix fan blade alignment
4:17
Просмотров 129 тыс.
How to fix condenser fan out of balance
4:15
Просмотров 80 тыс.
How to Wire a 4 Wire AC Condenser Fan Motor
3:22
Просмотров 295 тыс.
Музыкальные пародии
00:28
Просмотров 22 тыс.