Тёмный

DIY Fault Finding - Home Electrics 

The Diligent DIYer
Подписаться 12 тыс.
Просмотров 979
50% 1

DIY fault finding on my kitchen socket circuit.
Amazon links:
- Stabila Mini Level - amzn.to/3wPlcCm
- Long nose VDE pliers - amzn.to/3yvpxLn
- VDE screwdrivers - amzn.to/3Vc9ACD
- Multi meter - amzn.to/4bsJCRi

Хобби

Опубликовано:

 

22 май 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 15   
@patburke5740
@patburke5740 Месяц назад
Great video, please do a follow up video to show us how you got on.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Месяц назад
Thanks Pat! All fixed and filmed, just need to edit it and upload, I expect it will be some time early next week. Thanks for watching!
@BLOCKsignallingUK
@BLOCKsignallingUK Месяц назад
My preference (assuming the cable damage is below the backbox) would be to chop out a new backbox below to hold some terminals and replace the burnt end. Cover with a blanking plate.
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Месяц назад
Yep that is a good idea and had been one of my plans, depending on how bad the damage was. Unfortunately it wasn’t an option that would work, as you’ll see in the follow up video next week. Thanks for watching!
@wackypeace1135
@wackypeace1135 Месяц назад
Great vid
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Месяц назад
Thank you! And thanks for watching!
@sunnydavies3990
@sunnydavies3990 Месяц назад
Couldn't see if there was a grommet on one of the backboxes, I'm sure its there!
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Месяц назад
Yep there is, probably just not that easy to see on the video. Thanks for watching!!
@JamesBrown-yn7xr
@JamesBrown-yn7xr Месяц назад
I would have expected the RCD to trip and not just the MCB as the RCD should detect earth faults. I'm not qualified and just curious as a theoretical question why is your MCB triped with over current and not the RCD with Earth fault? Is you earth cable continuity ok?
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Месяц назад
They both tripped every time actually, the rcd switch just doesn’t fall as far as the mcbs, so in the video might not have looked like it tripped, but I assure you both did! Thanks for watching!
@hb5777
@hb5777 Месяц назад
Tripped circuit = RCD Vertical screw heads = OCD 😅
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Месяц назад
Haha yes it is a little OCD, thanks for watching!
@iainhay2823
@iainhay2823 Месяц назад
@@TheDiligentDIYer1759and a level for the socket as well. Totally approve👍
@covbloke511
@covbloke511 Месяц назад
Why not just guess!!! Very dangerous for a DIY?
@TheDiligentDIYer1759
@TheDiligentDIYer1759 Месяц назад
Thanks for sharing your opinion
Далее
Repairing Damaged Cables in a Wall
7:32
Просмотров 1,1 тыс.
Everything I Got Wrong On My Bathroom Renovation
18:18
Просмотров 1,3 тыс.
МНЕ ИСПОРТИЛИ МАШИНУ #shorts
00:30
Fault Finding RCD tripping - Electrician
20:18
Просмотров 78 тыс.
Things to know BEFORE starting on a Switchboard
8:06
WORST DIY ELECTRICS I'VE EVER SEEN! 🤯
22:52
Просмотров 649 тыс.
How to Fit a Security Light - Easy DIY
16:38
Просмотров 2,4 тыс.
BIGGEST DIY Mistakes Joining Cables
8:52
Просмотров 214 тыс.
Kitchen Lighting Upgrade: Easy Under Cabinet LED Strip
9:10