Тёмный

FAN PRESSURE TEST 

Geoffrey Needs training
Подписаться 7 тыс.
Просмотров 20 тыс.
50% 1

Worcester cdi fan negative pressure test fault finding test if heat cell is block

Кино

Опубликовано:

 

24 янв 2018

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 22   
@justsendmelocation5068
@justsendmelocation5068 4 года назад
I enjoy your videos very informative. I always clean out the combustion chamber First, flush the dirt in siphon then FGA and gas rate.
@snigie
@snigie 5 лет назад
I’m having quite a few low fan pressures due to a lazy fan. Tends to be more on the cdi’s too
@pasgas12safe58
@pasgas12safe58 5 лет назад
Great video mate, thanks for sharing with us. 5⭐⭐⭐⭐⭐
@TheBisdak12
@TheBisdak12 6 лет назад
great video from worcester legends
@manjsingh6500
@manjsingh6500 2 года назад
U9 fault on green star 532i. On ch/hw. Takes 25 mins to get to 82 deg Cleaned heat exchanger
@Jamesskinner11
@Jamesskinner11 6 лет назад
Class video bud!
@jezlucas3878
@jezlucas3878 Год назад
Hi got poor negative fan presure, just done full service. Blown though test point and I know manometer OK. Any pointers on negative can cause this
@adamcarter781
@adamcarter781 6 лет назад
Good video. Did same job recently with same outcome on fan pressure, at -4.5mbar, plus some minor adjustments on gas valve. Interested in how you tested seal integrity, can you say more about the sensor. Thanks again, look forward to next video.
@cousinbenson2336
@cousinbenson2336 5 лет назад
Adam Carter use a small mirror, if it steams up the seal has gone
@adriatikqypi9356
@adriatikqypi9356 4 года назад
Brilliant
@umarg06
@umarg06 4 года назад
You are superstar
@francoporco9780
@francoporco9780 6 лет назад
What was the probe you used to check seal integrity? Thanks
@rayc1503
@rayc1503 5 лет назад
It's an Anton Ng sniffer, if you haven't already figured it out.
@theplumbersmate2471
@theplumbersmate2471 5 лет назад
franco porco f&
@craighetherington8992
@craighetherington8992 2 года назад
Hello. I recently gave a full service to Worcester CDI. Cleaned heat cell, new electrodes installed, new baring plate and all seals installed. Max and min readings perfect. But fan pressure and gas rate is still less than they should be. What else could be causing these low readings?
@johnabiodun5540
@johnabiodun5540 2 года назад
Faulty fan not running as fast as it should be.
@craighetherington8992
@craighetherington8992 2 года назад
@@johnabiodun5540 Thank you. I’ll look into that 👍🏽
@johnabiodun5540
@johnabiodun5540 2 года назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-GiRo01XDd5M.html In this video he shows how to check the bearing plate and adjust the fan speed. Maybe try that 1st 👍🏽
@BrosnanEvans
@BrosnanEvans 6 лет назад
What tool you using to clean heat ex?
@cousinbenson2336
@cousinbenson2336 5 лет назад
BrosnanEvans it's the cdi cleaning kit. There's a part number for the kit in the back of the MIs or look for it on internet
@anthonybennett3616
@anthonybennett3616 4 года назад
What fault made you check the fan pressure?
@paulrossiter9567
@paulrossiter9567 3 года назад
Fan pressure should always be checked irrespective of faults 👍
Далее
greenstar erp cross leaking heat cell
9:04
Просмотров 8 тыс.
МОЙ НОВЫЙ ДОМ
1:01:04
Просмотров 1,5 млн
expansion fault finding
4:55
Просмотров 20 тыс.
Gas Training - How To Test A Boiler Fan - Combi Boiler
22:58
How to test a CAN bus network with a meter
16:07
Просмотров 450 тыс.
Greenstar gas valve
9:21
Просмотров 10 тыс.
Must watch new special comedy wait for end 😆🤣
0:49