Gas Furnace Basics: Part 2 

TheWXTV
Подписаться 15 тыс.
Просмотров 100 тыс.
50% 1

Part 2 of the diagnostic process is combustion analysis. Mike takes temperature readings, checks for gas leaks, measures carbon monoxide and draft, and inspects the burn.
For a high-res version of this video, please visit: www.weatherization.org/wxtv6p2

Опубликовано:

 

3 янв 2011

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 15   
@mjba852
@mjba852 8 лет назад
Very clear video and helpful What if the fan is not running or damaged or not connected does the burners will turn on with no air flow ? Or it will shut off the gas automatically.
@DONALD1951
@DONALD1951 5 лет назад
MJ BA it will fire up then shut off quickly by the high limit
@kfpark1969
@kfpark1969 11 лет назад
Hey Mike, How about using some mastic to seal up those holes so you don't have a possible negative pressure near draft hoods in a CAZ zone, you already determined that there isn't enough combustion air and make-up air for that space. Change that filter and better inspect for leaks or cracks in those heat exchangers, if it's been hitting the high limit like that and not moving enough air across the exchanger, my agency just changes anything out with a draft hood, standing pilot, and over 900ppm.
@DONALD1951
@DONALD1951 5 лет назад
Is the right side of the furnace against a combustible wall? Wood? Doubt if it’s 0 clearance on the sides. High limits are usually set for 180 degrees.
@bootman4er
@bootman4er 11 лет назад
That old Johnston should have been replaced years ago. It must be about 60% efficient. Looks like the gas valve was recently replaced. That thing don't even have a/c ! Ask the customer "Are there any registers closed"? They'll say no but when you go check about half of them will be closed. Put them in a Trane XV 95 and a 16 seer a/c and save them some money.
@justinfrias9030
@justinfrias9030 10 лет назад
And the filter made it quieter not beccause it's rubbing against anything it's probably Just so dirty that it's not giving you enough return air so your blowers working harder to get the air
@vihuelero1001
@vihuelero1001 9 лет назад
actually if a blower is moving less air than it is supposed to, it is working less. If you were to actually use an amp probe and check how many amps it is pulling, you will find that with less air flow it will be pulling less amps. Therfore the blower is working less. I know you posted this 11 months ago, but I couldn't help but to correct you on this
@rocker8692
@rocker8692 8 лет назад
What's an ok level of CO safe to work around?
@RyanMinaker
@RyanMinaker 7 лет назад
like 200 if you want a headache and nausea, 400 is life thretning after a few hours, 800 you'll die in an hour or so.
@DONALD1951
@DONALD1951 5 лет назад
0
@topg893
@topg893 3 года назад
Anything over 100 ppm is unacceptable
@billybassman21
@billybassman21 11 лет назад
I didn't know Eric Wareheim from Tim and Eric Awesome show did HVAC work.
@justinfrias9030
@justinfrias9030 10 лет назад
Ya get a new furnace
@InkedUpHonda
@InkedUpHonda 6 лет назад
What dumpy tools brother. My analyzer is 12,000 dollars. Start buying Ecom.
Далее
Gas Furnace Basics: Part 3
18:20
Просмотров 68 тыс.
Sequence of operation
19:05
Просмотров 474 тыс.
NOOOOO 😂😂😂
00:15
Просмотров 3,3 млн
Я КУПИЛ САМЫЙ МОЩНЫЙ МОТОЦИКЛ!
59:15
Understanding HVAC (For Non-Technical People)
16:01
Просмотров 375 тыс.
Boiler Basics: Part II - Clean, Test, & Tune
15:17
Просмотров 248 тыс.
Gas Furnace: Component Identification (1 of 2)
14:59
Просмотров 103 тыс.
Boiler Basics: Part I - Combustion Air and Drafting
15:07
Furnace Parts and Functions Explained
15:10
Просмотров 716 тыс.