Тёмный

How does the T&P water heater safety valve work. 

grayfurnaceman
Подписаться 158 тыс.
Просмотров 25 тыс.
50% 1

This one disassembles this combination pressure and temperature relief valve. I explain the temperature portion of the valve and the rather simple action of the pressure relief.

Хобби

Опубликовано:

 

5 май 2019

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 62   
@jimobrien84
@jimobrien84 5 лет назад
I gotta say I watch a lot of hvac videos on RU-vid from several dozen channels and yours are consistently some of the most useful to me. You’re exceptionally good at explaining and demonstrating these concepts in a plain and understandable way
@jeffneedstogivejakeaturnon1083
Holy Taco pumps!! I started watching your videos after I took one of your classes in early 2015 and I just saw that your videos have been viewed almost 49 MILLION times! Thats awesome. Thanks for taking the time to do them. We appreciate it.
@gpdewitt
@gpdewitt 5 лет назад
Thanks for the video, great training for some of my home inspector friends. Watts recommends yearly inspection by opening and closing the valve, and every 3 years having a plumber remove and inspect the valve. This is written on the yellow plastic tag attached to the valve. More in-depth info used to be on their site, but due to a recent remodel, this is now very difficult to find.
@Rico-ns5dt
@Rico-ns5dt Год назад
Man I can't seem to find anything on these because I'm curious about shank length. Found one about an inch shorter than original but I don't see anything crucial about length. Besides maybe some surface volume 🤔. Any who, when GFM popped up I already knew I was going to get some quality information I never knew I needed. Big fan here. My college hvac/r instructor turned me onto you in 2014/15. Here in fresno calif. Whats funny is we seen a video of a water heater explosion during safety class and I remember him saying his wife was puzzled how that could happen and he said to her, that shouldn't happen ever it's next to impossible someone somebody did something they weren't supposed to do. It's literally the reason I can't just use the inch shorter shank valve haha. 3.5in I guess I need 4in. But he literally beat every single subject, theory and science into us including safety. Big thanks.
@stevenlake4316
@stevenlake4316 Год назад
I tend to believe that the length has to do with the temperature that the valve opens at.
@capefalconkayak
@capefalconkayak 4 года назад
hey, thanks for this, it answered a question I needed to know but couldn't find elsewhere.
@averyalexander2303
@averyalexander2303 5 лет назад
Thank you for taking the time to make these awesome videos and congrats on 100K subscribers!
@danielthechskid
@danielthechskid 5 лет назад
I would imagine that the temperature probe works exactly the same way as a coolant thermostat on an engine, the wax melts and the liquid is less dense than the solid so it takes up more volume and forces out the pin via hydraulic pressure.
@grayfurnaceman
@grayfurnaceman 5 лет назад
I think you have it. GFM
@throttlebottle5906
@throttlebottle5906 5 лет назад
wax motor, 'aka' linear actuator :) you got it on the temp relief. the spring/compression height is obviously the pressure relief control.. that being said, as the rubber/nylon/ptfe disc seal compresses with age/thermal cycling the spring height changes as does seat pressure... yeah, this thought is well beyond plumbing/hvac and heavy into mechanical/engineering lol
@iliketakingshowers
@iliketakingshowers 5 лет назад
I like goo better
@sbxdotcom
@sbxdotcom 2 года назад
Lol I wasn't the only one referencing cars when trying to think what that stuff was.. you guys are cool
@alphaomega8373
@alphaomega8373 4 года назад
Thank you for lifting up the vavle! My brain refused to figure it out and dont want to get burned!
@MsFishingdog
@MsFishingdog 5 лет назад
another great video from the one and only. thank you
@grayfurnaceman
@grayfurnaceman 5 лет назад
Welcome GFM
@philfalz01
@philfalz01 5 лет назад
great info i always wondered how they worked
@masterpaine9161
@masterpaine9161 8 месяцев назад
One thing is for sure. Before assuming the t&p valve is bad and replacing it, you always check the p.s.i. and temp of the water heater/boiler. Too often ive heard my plumber buddy say. "I replaced the damn thing and found out the setpoint was too high". Lol
@lcampm2
@lcampm2 5 лет назад
More specifically, this invention relates to an improved thermal relief valve of the type described in U.S. Pat. No. 5,641,119, which is incorporated herein by reference. In that patent, a thermal relief valve is described as suitable for conventional or miniature fluid piping systems. The thermal relief valve includes a cylindrical valve body with a bore that houses a thermal actuator. The actuator has a piston and wax that melts and expands at a predetermined temperature. When fluid temperature exceeds the predetermined level, wax expands and causes the piston to extend, thereby moving the thermal actuator axially within the housing. The actuator moves from its normal closed position in which the actuator engages an O-ring seal to an open position in which the actuator unseats from the O-ring and forms a gap therebetween. Fluid may then pass through the valve, flowing first through an annular passage between the circular exterior of the thermal actuator and the circular interior wall of the bore in the valve body that houses the actuator. The fluid next flows through the gap adjacent the O-ring seal and exits the valve.
@grayfurnaceman
@grayfurnaceman 5 лет назад
Very thorough explanation, thanks GFM
@tommyt5815
@tommyt5815 5 лет назад
These r always great and informative videos
@glennhanson6843
@glennhanson6843 2 года назад
B&G had or still has heat motors that worked on that principle in zone valves. Some kind of wax or something inside would get hot and expand opening the zone valve.
@thefloridaplumber2631
@thefloridaplumber2631 5 лет назад
wow great video, I really like how you show how it works.
@grayfurnaceman
@grayfurnaceman 5 лет назад
Glad it helped. GFM
@Geobli
@Geobli Год назад
Great video, very informative and detailed.
@mrsergiog9
@mrsergiog9 3 года назад
Clear and simple!
@sbxdotcom
@sbxdotcom 2 года назад
Saving this video... super awesome 👌
@parker1038
@parker1038 Год назад
Great video thanks
@watermanone7567
@watermanone7567 5 лет назад
very good explanation. Thanks
@grayfurnaceman
@grayfurnaceman 5 лет назад
Welcome GFM
@ppark1229
@ppark1229 4 года назад
learning every day!
@starlite528
@starlite528 5 лет назад
The Goo is wax. It's a wax motor, as also used in automotive thermostats. AvE has a video on them.
@starlite528
@starlite528 5 лет назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-MiADday0mDA.html
@grayfurnaceman
@grayfurnaceman 5 лет назад
Good thoughts. Probably true. Thanks GFM
@throttlebottle5906
@throttlebottle5906 5 лет назад
"shmoo" lol
@johnkrim8377
@johnkrim8377 5 лет назад
I would think the material inside the tube is similar to the wax in a taco zone valve head that expands at a set temp and maybe contracts when it cools down . Retired master plumber.
@Sparky-ww5re
@Sparky-ww5re Год назад
I've replaced a T&P valve that failed once, I'm not a plumbing expert by any means but I understand how a water heater works and that the T&P valve is a safety feature that can save your life in the unlikely event a thermostat is locked up and the hi limiter fails. I always wondered how the valve works to provide high pressure and high temperature protection in one device.
@NZ2STROKE
@NZ2STROKE 10 месяцев назад
Normally when they "fail" they are doing their job and there is another problem that needs to be fixed.
@Sparky-ww5re
@Sparky-ww5re 10 месяцев назад
@@NZ2STROKE it became jammed with minerals. I was testing it by flipping the lever to make sure it can relieve if it needs to, and the water wouldn't stop and kept dripping when I let go. Exercising the lever didn't help and I think the water heater in question was close to 10 years old. But you're right, if the valve is dripping there's likely a reason, thermal expansion is a more common issue than you might think because many local plumbing code require a pressure reducing valve or check valve at the water meter to prevent contamination of the water main if there's ever a sudden drop in water pressure.
@tipper87
@tipper87 3 месяца назад
The goop is a wax seal. No water is supposed to be in it. The wax is meant to prevent water from leaking to the bottom of probe.
@masterofnone7846
@masterofnone7846 27 дней назад
Neat video
@rodpaget9796
@rodpaget9796 2 года назад
Goo might be high expansion liquid that acts against the piston
@throttlebottle5906
@throttlebottle5906 5 лет назад
it could be combo wax/alcohol motor, alcohol or \similar, liquid behind the wax, wax just used as a seal/buffer. it staying out could be due to passing the motors spring thermal rating, maybe it melts also.never cared to dissect one
@xelaju8
@xelaju8 5 лет назад
I liked it. Thanks for your videos.
@grayfurnaceman
@grayfurnaceman 5 лет назад
Welcome GFM
@JoeLinux2000
@JoeLinux2000 5 лет назад
Very interesting. There is lots of information on the web related to how they are supposed to work but virtually nothing about how they are constructed so that they do work. Have you done a video on the old style thermocouples? I've always wonder how they work. I have about 15 of them that I saved after they were taken out of service.
@grayfurnaceman
@grayfurnaceman 5 лет назад
Check my channel. Lots of them. GFM
@ATeamAdam
@ATeamAdam 5 лет назад
How does it feel to have the most popular HVAC channel?
@grayfurnaceman
@grayfurnaceman 5 лет назад
Interesting. No one told me. I do hope the videos help. GFM
@throttlebottle5906
@throttlebottle5906 5 лет назад
the plastic on the wax motor is probably "pex" but I'm not 100% sure, never gave it a thought before :)
@Rickmakes
@Rickmakes 5 лет назад
On the topic of water heaters, are you familiar with a product called Mag-Erad? I saw an ad on Facebook for it the other day. I guess it is for descaling a tank water heater. I thought about getting some to test out.
@grayfurnaceman
@grayfurnaceman 5 лет назад
I have no experience with it. GFM
@DLTrally
@DLTrally 3 года назад
Does the prove has to be in contact with water? I got a little water heater with the valve on top but I would like to install a elbow and connect it to a pipe so it can be installed horizontally, would that work? It won’t fit unless I do that. Thank you
@grayfurnaceman
@grayfurnaceman 3 года назад
I would not move the valve. It is a high liability safety device. GFM
@BlessedFloridaMom
@BlessedFloridaMom 5 лет назад
Sir if you don't mind ~ our issue with outside AC: When we turn it on it runs fine - as soon as it runs awhile - it goes off and you will hear the compressor come on and the click, but the big fan won't start back - is it a relay problem do you think?
@BlessedFloridaMom
@BlessedFloridaMom 5 лет назад
We already replaced the capacitor.... Thank you for any thoughts you may have....
@grayfurnaceman
@grayfurnaceman 5 лет назад
@@BlessedFloridaMom If the outdoor fan stops, and the capacitor has been replaced. the fan motor is probably failing. Check to see if the motor is hot. GFM
@BlessedFloridaMom
@BlessedFloridaMom 5 лет назад
Thank you Thank you!!!! You are so wonderful to share your knowledge.... We watched your videos and learned about the fan motor and yes thats the key we think as well - we finally got tired of being ripped off! Do you believe we paid $300 for a fuse that when we took the cover off was sitting in the front???!!!! Now that I am learning about this stuff I am insulted! A friend of my neighbors who runs his own outfit today came for free and confirmed just what you said - fan motor - you are wonderful!!! Thank you and God Bless you and your work!!!
@Ultrajamz
@Ultrajamz 2 года назад
Tapped the pin on the top of mine and it stopped weeping
@grayfurnaceman
@grayfurnaceman 2 года назад
Hopefully, that will continue to keep it sealed. GFM
@Ultrajamz
@Ultrajamz 2 года назад
@@grayfurnaceman it shouldn’t cause the mechanism to stop working though right? I can still open and close the valve (had to re-tap the pin to seat it again) i’m very light tapping with barely much force using a rubber mallet
@grayfurnaceman
@grayfurnaceman 2 года назад
@@Ultrajamz You are doing correct with the rubber mallet. These valves are are pretty much idiot proof. Even if the lever is clamped with a C-clamp, (yes, I have seen this) it will still relieve. GFM
@kirbyjohnson5487
@kirbyjohnson5487 3 года назад
Yada yada yada yada yada yada yada yada yada yada!
Далее
Как похудеть на 10 кг ?!
07:06
Просмотров 622 тыс.
Why does a geyser need a TP Valve?
6:04
Просмотров 25 тыс.
PRV's How do Pressure Relief Valves work? Altecnic PRV
10:57
Water Heater Leaking At Relief Valve Diagnose / Fix
15:29
How an Electric Water Heater Works
14:33
Просмотров 265 тыс.
Replace Water Heater T&P Valve (Step-by-Step!)
6:05
Просмотров 26 тыс.
Refrigeration Videos:   Pressure Releif Valves leaking
17:14