Тёмный

How To Install a 30 amp Dryer Circuit With Breaker and Outlet 

askmediy
Подписаться 99 тыс.
Просмотров 81 тыс.
50% 1

Always use a 10/3 wire. The wire will have 4 wires in it. Two hots, a neutral and ground wire.
Where you can find me and more information
If you found this video helpful please subscribe
My website www.askmediy.com
Facebook / askmediy
Twitter / askmediy
Pintrest / askmediy

Хобби

Опубликовано:

 

9 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 114   
@RBG-tr9ce
@RBG-tr9ce 4 месяца назад
I'm doing this exact job tomorrow AFTER I fish the wire down the walls. I had done this 50 years ago so this was a good refresher. "See one, do one , teach one".
@davidparker2173
@davidparker2173 Год назад
You make me feel like an apprentice on the job with a friendly pro who is not dedicated to ruining my day. You also detail fairly well. I would rather hear things again and again than for some guy to assume I already know this, and this, and that. I just hit the like, and subscribe. Thanks
@happycamper137
@happycamper137 Год назад
Thank you for this video, I agree with all the comments. It really helped me, every electrician I talk to say they'll do it and don't. I learned what the wires are for and the positions. Which now gives me knowledge and confidence. Again, thank you.
@CasualRican
@CasualRican Год назад
Thanks again for this video, I installed my dryer outlet by following your instructions. 👍
@Askmediy
@Askmediy Год назад
Hope it works lol. Good deal
@davidgasperlin6807
@davidgasperlin6807 Год назад
Great video im putting in a new line to my dryer so this really helps
@SAWA-nx5co
@SAWA-nx5co Год назад
I spent few hours to find this. Thanks. You explain all from A to Z)))
@insanechevy91
@insanechevy91 Год назад
Guy reminds me of a old guy I worked with last summer wired aleast 4 boxes with him more then I can remember service calls for light fixtures and ceiling fans and outlet replacements lol cool guy 😂
@paulholloway5458
@paulholloway5458 Год назад
Brilliant Work, Thanks.Just needed a fresh reminder.
@Randomuploads2012
@Randomuploads2012 Год назад
Glad your uploading again!!! 💪🇮🇹
@davesillik
@davesillik 5 месяцев назад
Thank you. Haven't ever done 220 but it all worked out beautifully and safe.
@Askmediy
@Askmediy 5 месяцев назад
Awesome glad to hear it
@alsemi-back-up579
@alsemi-back-up579 Год назад
Great Video & Explanation of Wiring The RightWay! Thanks ForThe Upload Keep up The Great Work That You Do From Canada.
@leskleinman3302
@leskleinman3302 2 месяца назад
Brother from the northeast best friggen video hands down no elaborate BS straight to the point, you are the man!!!
@Askmediy
@Askmediy 2 месяца назад
Thanks buddy, yeah who has time for BS
@VicToR_Rider
@VicToR_Rider 26 дней назад
Lol u nailed it with hearing a pop and the wife yelling fire😅 I messed up changing dryer plug. Mixed the black and white.
@jacknelson4212
@jacknelson4212 Год назад
Great video. Only one I could find that hooked up the 4 wires and breaker in the breaker box. Also good explanation for the reason from going from 3 to 4 wire recepticle.
@jesserentas7425
@jesserentas7425 10 месяцев назад
Bro you ain't kidding I'm looking at these other videos thinking where in the world do the other 2 wires go christ!😂
@germangomez7097
@germangomez7097 Год назад
Perfect explanation. Just what I was looking for. Thank you
@Askmediy
@Askmediy Год назад
Awesome, glad I could help you out.
@blizte3
@blizte3 9 месяцев назад
@@Askmediy Nema 14-30, my 30 amp,125/250 volt, 14-30R, 3-pole, 4-wire , my 4 prong plug 30 amp electric dryer is wired to 30 amp outlet is not working why?
@FrankBocker
@FrankBocker Год назад
I really like all the little side details and prerequisite information peppered in this tutorial. There's a lot of higher-budget stuff around that's not nearly as informative.
@Askmediy
@Askmediy Год назад
Thanks Frank. It’s what I try to show
@briankeithhamilton4216
@briankeithhamilton4216 7 месяцев назад
Loved the Ending! Thank you🤗
@DominickAmorosso
@DominickAmorosso 7 месяцев назад
Thanks buddy.
@theadventuresofchris1409
@theadventuresofchris1409 Год назад
thank you for making this video
@youngjimmystro8176
@youngjimmystro8176 2 месяца назад
Lmao I love the ending man thanks for this video. Very helpful. I think I mis connected my outlet thanks for this!
@Askmediy
@Askmediy 2 месяца назад
Thanks buddy, glad you liked it.
@jsville2023
@jsville2023 Год назад
This guy is great. Subscribed.
@Askmediy
@Askmediy Год назад
Thanks buddy
@malindabrowning9240
@malindabrowning9240 Год назад
I think you’re hilarious. I recently wired up my breaker and the outlet for a dryer, and I definitely was a little nervous about turning on the breaker. You made me laugh so hard when you were teasing us about it.
@Askmediy
@Askmediy Год назад
LOL But very true LOL.
@blizte3
@blizte3 9 месяцев назад
@@Askmediy Nema 14-30, my 30 amp,125/250 volt, 14-30R, 3-pole, 4-wire , my 4 prong plug 30 amp electric dryer is wired to 30 amp outlet is not working why?
@AngelerFils
@AngelerFils Год назад
00:43 The counting made me burst out laughing 🤣🤣
@lionwolf5768
@lionwolf5768 8 месяцев назад
Great video thank you!
@be4fourty
@be4fourty Год назад
Thanks for the video
@DelmaRaySmithJr
@DelmaRaySmithJr Год назад
Funny way of sharing what you know, in a humorous manner, thx
@Askmediy
@Askmediy Год назад
Can't be a stiff right.
@IamMattW.
@IamMattW. 9 месяцев назад
Perfect! Exactly what I’ve been looking for. Nobody explains the panel part. And you made this video very entertaining! Hopefully my wife doesn’t yell at me though 🤣
@Askmediy
@Askmediy 9 месяцев назад
Good deal. Thank you so much
@blizte3
@blizte3 9 месяцев назад
@@Askmediy Nema 14-30, my 30 amp,125/250 volt, 14-30R, 3-pole, 4-wire , my 4 prong plug 30 amp electric dryer is wired to 30 amp outlet is not working why?
@robmorse5239
@robmorse5239 Год назад
Thanks... I really like you teaching style
@Askmediy
@Askmediy Год назад
Thank you so much.
@jasonmacdonald27
@jasonmacdonald27 10 месяцев назад
GREAT VIDEO
@user-je3jo1kn8x
@user-je3jo1kn8x 6 месяцев назад
Excellent video
@ReyesCTR0025
@ReyesCTR0025 11 месяцев назад
Nice video!!!
@christianahava
@christianahava 9 месяцев назад
Top notch info
@bryanlipscomb8918
@bryanlipscomb8918 Год назад
You funny dude. Great tutorial
@stevenramsar456
@stevenramsar456 Год назад
Very helpful thanks😂😊
@troyandeviegray9736
@troyandeviegray9736 Год назад
It looks like the wiring on the hot water tank are 12 ga is 10ga okay for the run of about 10 ft and 10ga 3 wire outfit a dryer that’s even closer to the power panel, also I have a Meg welder the plug has a ground and a small and large knife blade the the outlet shows 120/240 at 50amp, how big should the wire be and what size breaker do I need
@whoisradu
@whoisradu Год назад
Hey guys what if the new 30A breaker doesn’t fit in the old box? Do you just get two 30 breaker that are the same type as the old breakers and run the two hots to each? Thanks for any advice
@ricodinero4926
@ricodinero4926 6 месяцев назад
come on askmediy , you make it look easy.
@Askmediy
@Askmediy 6 месяцев назад
Because it is. You can do it
@oliverlu3259
@oliverlu3259 Год назад
make it very clear to me. good job. thank you1
@Askmediy
@Askmediy Год назад
Awesome. thank you so much.
@mikebartoli4755
@mikebartoli4755 Год назад
That was just like standing next to my uncle while he's teaching me something! Well done sir, thank you making this tutorial.
@Askmediy
@Askmediy Год назад
Very nice to hear. Thank you very much
@blizte3
@blizte3 9 месяцев назад
Nema 14-30, my 30 amp,125/250 volt, 14-30R, 3-pole, 4-wire , my 4 prong plug 30 amp electric dryer is wired to 30 amp outlet is not working why?
@marchaney
@marchaney 4 месяца назад
Thank you!
@alangloria939
@alangloria939 4 месяца назад
I was convinced until the end 😅 adrenaline just shocked my body
@LetsGo6009
@LetsGo6009 5 месяцев назад
Thanks!
@hamsbyyams
@hamsbyyams 5 месяцев назад
“Let’s just say this is being inspected. WhiCh iT’s sUppOSed tO Be 🤪.” Had me cracking up lol
@user-ym3nk2ww4c
@user-ym3nk2ww4c 8 месяцев назад
Excellent explanation... should I use 10/3 romex to the panel from a 30 amp inlet plug for a generator (7500 running watts)? Or can I use 10/2 romex?
@whoisradu
@whoisradu Год назад
You make me feel like I can actually do this, even though I am extremely terrified, L O L
@bobbydbuilder2873
@bobbydbuilder2873 Год назад
I have old air compressor with a 10.20 nema. The only outlet I could find does not have a ground screw. Just 2 gold hot and silver neutral. I need some advice or a quick how to. Does it need to have a ground or just wire as is?
@Askmediy
@Askmediy Год назад
Are you sure it's 220 volt?
@Douglaskyle9191
@Douglaskyle9191 7 месяцев назад
If my wire to the black dryer outlet box is damaged by a dog I feel like I could cut it shorter and move the outlet higher instead of running all wire for my outlet. I have exposed silver wires that wrap around the core that are severed but dryer still works.
@Askmediy
@Askmediy 7 месяцев назад
Seems like it would be better to just replace the dryer cord.
@Douglaskyle9191
@Douglaskyle9191 7 месяцев назад
The outlet it plugs into is damage but not the actual cord to the dryer. A dog ripped open the sheet rock and began to tear open the wire leading to the outlet. I found this when getting my house ready to sell. The old owners left me this surprise and I have been living with it for 6 years lol Also the outlet is against the floor which I think I saw is not code anyways. 1987 home
@Askmediy
@Askmediy 7 месяцев назад
@@Douglaskyle9191 There is no code on the height of the outlet. If the wire is coming above it, you should be able to just raise it up to good wire.
@joshcapecod6098
@joshcapecod6098 Год назад
Good video. Except the breaker is required to be GFCI...since 2020. And best to check the dryer cord hookup as well....kind of big things.
@josefcalderonromero8452
@josefcalderonromero8452 Год назад
Beautiful 🤩 exactly what I was looking for . Question. I want to install about 5-8 240 baseboard heaters in my basement. You think 2 30 amp circuits would be enough?
@Askmediy
@Askmediy Год назад
Most baseboard heaters are 20 amp. Please follow the instructions for sure.
@lionelbutnotrichie7703
@lionelbutnotrichie7703 2 месяца назад
Is there code for how far or close an outlet can be to the circuit box. I have to move my dryer to the opposite wall and the opposite wall contains the breaker box
@Askmediy
@Askmediy 2 месяца назад
No not at all. Distance, yes. But nothing you need to worry about.
@skippy493
@skippy493 Год назад
Hey man when are you going to post some new videos I really like your videos
@mattkelley7890
@mattkelley7890 9 месяцев назад
Never showed a close up inside the box. THE MOST IMPORTANT PART
@djreag8614
@djreag8614 Год назад
HEY DOMINIC ,YOU DA MAN ,COME UP TO NOVA SCOTIA AND DO SOME ELECTRICAL ,,
@DominickAmorosso
@DominickAmorosso Год назад
Sure thing
@melquemcleash6607
@melquemcleash6607 9 месяцев назад
This guy is a good teacher!
@djreag8614
@djreag8614 Год назад
Hey Dom, can I put neutral and ground wire on the same side in the panel box?
@DominickAmorosso
@DominickAmorosso Год назад
Sure, as long as it’s not a sub-panel
@djreag8614
@djreag8614 Год назад
@@DominickAmorosso THANKS DOM, TOO EXPENSIVE TO HIRE ELECT. SENIOR YA KNOW ,,, NOW ONE MORE QUESTION THE COPPER GROUND THATS BARE ,CAN I JUST ATTACH IT TO THE SCREW AT THE BACK OF THE BOX THEN CONNECT IT TO THE GROUND PLUG OPENNING ?.. PLUS THERE ARE STILL LIVE WIRES EVEN THOUGH THE PANEL IS SHUT OFF RIGHT?
@Ojeramup12
@Ojeramup12 3 месяца назад
Can the green ground wire be connected to the white ground port? On 10;00 the wire is not connected.
@surferdude642
@surferdude642 11 дней назад
No. Only to the green ground screw and never connect a ground wire to a neutral intended location. The neutral and ground are bonded at first disconnect means (usually the main panel) and nowhere else.
@hwl6969
@hwl6969 Год назад
Does it matter if you use a blue plastic box or a metal one?
@DominickAmorosso
@DominickAmorosso Год назад
No, not at all but if you use a metal box, you will have to ground it
@geyser3445
@geyser3445 Год назад
I have a 220 volt electric hot water heater in my basement and want to add a switch at the top of my basement steps to turn it on and off. Can you show us how to do that and what switch to use? Thanks.
@Askmediy
@Askmediy Год назад
Just like any other switch. But it's a two-pole switch. Meaning that each side of the switch is for each hot. With 240 volts it's essential to switch both hots.
@nickdiamond7595
@nickdiamond7595 Год назад
0:45 He's giving us the neutral finger
@Askmediy
@Askmediy Год назад
Oh shit lol
@fuqui035
@fuqui035 4 месяца назад
The plate cover had Togo first behind the plug
@tomassoyweyvon4902
@tomassoyweyvon4902 Год назад
Hey, Piasan...you mentioned Old vs New dryers with electronics, the question now is, the home dryers are wired with two wire 10, i had a new washer dryer installed with electronics, should i convert the two wire to three 10 ???? access is no problem
@Askmediy
@Askmediy Год назад
Funny you say “piasan” I’m in Italy right now lol. Yes, you should if you can. Because you’ll need the two hots and the neutral. Ground of course
@tomassoyweyvon4902
@tomassoyweyvon4902 Год назад
@@Askmediy Hey, grazie per la reposta..I will do that...Godere!!!
@tomassoyweyvon4902
@tomassoyweyvon4902 Год назад
in addition i found out 1996 was the cutoff for three prong vs 4 per N.E.C., again Thanks
@Shadi2
@Shadi2 Год назад
By any chance, is your brother a botanist?
@jenniferowen-ep2gp
@jenniferowen-ep2gp Год назад
Tbis is a dumb question, but, you said 30 Amp breaker. And it's a double breaker... does that mean 15 and 15? Or 30 and 30
@Askmediy
@Askmediy Год назад
Not dumb at all. This means the total protected circuit is 30 amp
@seanrobbins1916
@seanrobbins1916 Год назад
I would apprentice with you
@marineguy4eva
@marineguy4eva Год назад
That neutral wire doesn't give a.....!
@susancasavant5227
@susancasavant5227 7 месяцев назад
what a goober
@TonyyFlow
@TonyyFlow Год назад
FIRST!
@blizte3
@blizte3 9 месяцев назад
Nema 14-30, my 30 amp,125/250 volt, 14-30R, 3-pole, 4-wire , my 4 prong plug 30 amp electric dryer is wired to 30 amp outlet is not working why?
@DominickAmorosso
@DominickAmorosso 9 месяцев назад
That’s a big question, what did you test?
@blizte3
@blizte3 9 месяцев назад
power on but dryer will not heat up@@DominickAmorosso
@blizte3
@blizte3 9 месяцев назад
also it has power spin tumbler without heat of any kind, on any heat setting, no sparks nor signs electric discharging beyond normal@@DominickAmorosso
@Hayden-sp1ol
@Hayden-sp1ol 8 месяцев назад
Extra grond wire via pig tail...? ?? I lost
@Askmediy
@Askmediy 8 месяцев назад
Ground outlet to metal box via the ground wire coming in
@woodstream6137
@woodstream6137 2 месяца назад
Probably calling an electrician. I need to run a ground to old 3 prong dryer outlet, thankfully its like a foot away from the breaker. My 30yr old speed queen finally finally died and I'm loathing having to buy a new budget machine.
@kavya1638
@kavya1638 Месяц назад
gonna leak something here... your dryer doesn't need to be using 30 amps, in fact, just a few pico amps. the reason it draws so much is because it was designed this way (on purpose), ie, the electric company needs to make money somehow. all your electronics, really, are designed to operate in the high amp range. 15amp vacuum cleaner, blender motor, etc.. turns out, a little project that draws energy out of the air feeds a heating element in the "pico amp range" and gets just as hot as your dryer's heating element. thanks to a few advancements in this field, the electric company is guaranteed to go out of business. give it a few years..
@tomburt5905
@tomburt5905 24 дня назад
Pico... Delicious
@valery9958
@valery9958 Год назад
ρяσмσѕм
@davidcase4600
@davidcase4600 Месяц назад
Unsat, unsafe. If you use a metal box, ground it
Далее
Stray Kids <ATE> Mashup Video
02:17
Просмотров 912 тыс.
How To Install a 220 Volt Outlet
15:20
Просмотров 197 тыс.
Correcting 3 Mistakes On A 240V Outlet Install
8:48
Просмотров 468 тыс.
How to Install a Breaker In Your Panel | LIVE!
16:48
Просмотров 557 тыс.