Тёмный

How To Wire a Dryer Outlet or Receptacle - Materials Needed for Dryer Wiring 

Benjamin Sahlstrom
Подписаться 436 тыс.
Просмотров 365 тыс.
50% 1

My Favorite Tool: amzn.to/3NIFJuO
4 Wire Flush Mount Dryer Receptacle: amzn.to/2tOC2uE
Double Gang Cover Plate: amzn.to/2gRqMw5
Double Gang Electrical Box: amzn.to/2ujKKVi
10/3 Wire: amzn.to/2ujOeH9
Wire Stripper: amzn.to/2gRgQ5U
QO 30amp Double Pole Breaker: amzn.to/2ujLIAU
Other Receptacle Options:
4 Wire Surface Mount: amzn.to/2vtApEt
3 Wire Flush Mount: amzn.to/2vtPPZo
3 Wire Surface Mount: amzn.to/2gRE4Jh
Tools We Recommend: www.amazon.com/shop/benjamins...
Video explaining how to install a dryer receptacle and the necessary materials.
0:00 - Dryer Receptacle Wiring Intro
0:17 - Breaker To Use For Dryer
0:37 - Wire Gauge To Use For Dryer
1:08 - Electrical Box For Dryer Receptacle
1:34 - What Receptacle To Use For Dryer
2:20 - Stripping The Wire
3:58 - How To Wire 220V Dryer Receptacle
7:45 - Mount The Receptacle
9:12 - SUBSCRIBE!!!
Thanks for watching and subscribing! As an Amazon affiliate I earn from qualifying purchases. Thank you for your support!
Ben

Опубликовано:

 

28 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 98   
@jgscott2100
@jgscott2100 4 года назад
Short, sweet, and to the point.... without a 20 minute lecture on BS just to hear yourself talk. If only everybody would do this!
@neillefevre7158
@neillefevre7158 Год назад
220 v
@edgarm9020
@edgarm9020 3 года назад
Thank you very much for your hard work and dedication making these videos. I work at a "Big Box Retailer" and ppl come in expecting is to know everything like an electrician. Guy came in wanting to install a 30 amp receptacle, but had no clue what parts he needed.
@AtticusDraco
@AtticusDraco 6 лет назад
thanx for your time, effort and list/links on this matter
@ken48229
@ken48229 3 года назад
Good video shows everything from the electrical panel including the type of wire with conductors and gauge all the way to the type of box to use four gang
@billmcclelland1393
@billmcclelland1393 4 года назад
Great tutorial ! May be the best, most clear instruction I have ever come across. Thanx alot !!
@RitchPaprocki
@RitchPaprocki 6 лет назад
Panel wiring was beautiful...a good electrician will even make the wiring you'll never see look nice! A pro!
@josegarcia6841
@josegarcia6841 6 лет назад
Installing a dryer outlet
@BestAccessDoors
@BestAccessDoors 7 лет назад
Great work, Ben! Will you be doing more videos on this topic soon?
@sarahwood2518
@sarahwood2518 2 года назад
Thank you for this video! I just moved my dryer down to my basement in an older house I just bought. In the process I found that I have to rewire it with new 10-3 instead of using the old 10-2 wire that was originally installed in the house. I was confused with how I needed to connect my 10-3 to the circuit breaker box. This helped me out so much!
@charlessjogren4971
@charlessjogren4971 5 лет назад
Thanks! This helped a lot
@garybrown7044
@garybrown7044 3 года назад
bravo! someone who knows how to insall a dryer receptacle. dryers & rangers were improperly wire for decades with 3 conductor romex which tied ground & neutral together. so many youtube videos on wiring are scary, this one is o.k.
@hippygypsy777
@hippygypsy777 3 года назад
The groud wire does need to be actually hooked up on the 4 prong receptacle. I found this out the hard way. Can't leave them hanging anymore.
@carlosargoncillo
@carlosargoncillo 4 года назад
thanks for this video.. well done.,.. very clear!
@kungfungify
@kungfungify 3 года назад
Would have been nice to see you hook it up at the breaker
@alexsummers3309
@alexsummers3309 12 дней назад
This
@Avarose-h7t
@Avarose-h7t Год назад
Thank you,, short and sweet and to the point exactly what I was looking for!!
@abrahamvaro775
@abrahamvaro775 4 года назад
Allways the best videos,thanks
@losmoore3358
@losmoore3358 2 года назад
Great video. I was going to hire someone, but seeing this video I gain confidence. Thank you. Well done..
@losmoore3358
@losmoore3358 Год назад
Now the only bad thing is I have to hire a electrician certified to ok my work and show the building inspector as well.
@bobychirayil8099
@bobychirayil8099 4 года назад
Very good info. Simple
@robertochavez8196
@robertochavez8196 3 года назад
Hello, Ben! First of all I wanna say thanks for your videos!! Now I would like to know how high should that box be. Could you please tell me?
@warrenwiz5
@warrenwiz5 5 лет назад
Good choice on carpet knife.
@MrLucifuge1973
@MrLucifuge1973 4 года назад
If you use that knife to install carpet then you need to find a new trade. If ya haven't already lost your fingers and buckets of blood. I remember my third day like it was yesterday even though it was over 20 years ago. I thought I was doing good by bringing my own folding knife and 12' tape to work. The old man seen them both and said get rid of them. It wasn't a long time before I realized why. If they fold then they can collapse. Our knives need to be solid and one piece. Folding knives are meant to be more convenient and are not able to handle the stress we put them under. Trust me it would be nice to just fold a knife up and put it in my pocket and not have to use a sheath or pouch. There just isn't any that work. Sorry for the long reply. Kind regards
@FranciscoCollio
@FranciscoCollio 3 года назад
Thanks for video but please don't use a ring when your work have a great week
@JamesMesidor
@JamesMesidor 5 лет назад
nice video thanks
@nickraffone1598
@nickraffone1598 5 лет назад
Make sure all screw are vertical!!!!
@rc3074
@rc3074 Год назад
Awesome video, thank you
@erickmendoza2486
@erickmendoza2486 5 лет назад
Thanks it work
@gaston.
@gaston. 3 года назад
thanks.. good info! Helped me out!!
@Lilmiket1000
@Lilmiket1000 5 лет назад
Sorry to ask. but your washer hookup. I see your supply and drain lines aren't connected like most of them are. they are placed on either side of the stud. where did you get those from? I've been looking but cant find them. Also the recessed dryer exhaust too. thanks!
@khord2857
@khord2857 3 года назад
Can this be done to any outlet? For example the house my wife and I are moving into has gas connector for the dryer. Our dryer that we have in love is electric. If there’s an outlet close by in the laundry room am I able to change it to be for this type of outlet? Thanks
@jamescc2010
@jamescc2010 2 года назад
What is I don't have a ground wire for condo built in 1987? Should have one but just wondering. We will need to replace the old 3-prong receptacle for an old electric dryer with 4-prong receptacle.
@tedlahm5740
@tedlahm5740 2 года назад
Orientation for the receptacle to match the plug on the cord? Cord does not come with appliance ?
@stevekennison1379
@stevekennison1379 3 года назад
What about the CB panel hookups?
@bullet9109
@bullet9109 2 года назад
Thank you sir!
@MrMed-hl2fq
@MrMed-hl2fq 3 года назад
why don't we have to ground to the metal box as is common with other wiring of fixtures?
@hernimnimeisa9776
@hernimnimeisa9776 Год назад
Very good information
@fg146
@fg146 Год назад
does the latest NEC codes require a 30 AMP GFCI breaker?
@user-im5tk5te5c
@user-im5tk5te5c Год назад
so the ground wire is indicated on the plug outlet and the rest of the wires you just made it neatly and snug?
@dwoodog
@dwoodog 3 года назад
Wish you had explained why a dryer receptacle (240v) needs a white neutral wire.
@rickbradley5373
@rickbradley5373 2 года назад
Dryer plugs and stove plugs look the same. But are different. Dryer plug he used the neutral was shaped like an L. That’s your white wire. The stove plug the neutral doesn’t have the L shape. It’s straight. Just to let everyone know the difference
@twicv912
@twicv912 3 года назад
Why does an electric dryer outlet burn /melt with dryer cord. Reasons?
@whoisradu
@whoisradu Год назад
I wish I could do this!
@corazondestrozado1890
@corazondestrozado1890 7 лет назад
what side wire can i use for light LED CAN YOU MAKE A VIDEO LED LIGHT
@romyjimenez1462
@romyjimenez1462 7 лет назад
Bansnsnbsbd
@davidfarina8958
@davidfarina8958 Год назад
Maybe want to mention 8/3 wire for voltage drop if the dryer is quite a distance from the box like mine but otherwise great
@jcmftobi14
@jcmftobi14 Год назад
by code, how far does an elec outlet have to be from a water source?
@bmarie8965
@bmarie8965 6 лет назад
Im moving my dryer to a spot that dont have an outlet. Can i rewire from the regular plug thats 5 ft away. And route the wire to a dryer plug. If that makes sense
@goaliedude32
@goaliedude32 6 лет назад
No. Regular plugs are 15 or 20 amp. Dryers need 30 amp circuits. You probably have this fixed already but if not hopefully I helped.
@LostTechnologiez
@LostTechnologiez 5 лет назад
the wire is to small
@sianteo1986
@sianteo1986 3 года назад
Thanks. Is there any specific height for the dryer outlet in the basement.
@MrItalianfighter1
@MrItalianfighter1 3 месяца назад
A minimum of 3 ft from the finished floor. I just put mine around 38" from the floor, so it's accessible to unplug without having to pull the dryer out of the way. That lands the plug just behind the top side of the dryer and mostly out of sight.
@jerylcarter330
@jerylcarter330 6 лет назад
You didn't hook it up in the breaker box
@BenjaminSahlstrom
@BenjaminSahlstrom 6 лет назад
Jeryl Carter Sorry man. Will try to get a video up about how to get that part done step by step in the future. Thanks for the tip.
@zueszues3178
@zueszues3178 3 месяца назад
Are you supposed to remove the copper strip?
@richardtrevino8216
@richardtrevino8216 3 года назад
Are ground and neutral bonded or connected on the outlet? So if you did an ohm test they would be connected?
@tedlahm5740
@tedlahm5740 2 года назад
Not on 4 wire install.
@nickjones9613
@nickjones9613 5 лет назад
6:32 It’s not color coded so how did you know what wire to put for each screw?
@slugh8499
@slugh8499 5 лет назад
nick jones the plug typically says “W” for the neutral and the ground slot looks different from everything else (opposite side of neutral) and “X” and “Y” r interchangeable red and black
@mialgri
@mialgri 2 года назад
Thanks
@jdjensen2416
@jdjensen2416 4 года назад
How did you run the wire into the wall on the other side of the receptacle?
@BenjaminSahlstrom
@BenjaminSahlstrom 4 года назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-7R8SxBXC86w.html This is not the same exact installation but I show another range wiring example with the wall open. Hopefully it will help a bit!
@sidvids48
@sidvids48 Месяц назад
How boyt the breaker box connection
@DIYDr.
@DIYDr. Год назад
Explaining the wiring was helping
@KenNYC212
@KenNYC212 4 месяца назад
Hi, hoping you can help... All I'm trying to do is hookup a dryer in an older building (1976 condo) and I've added a ground and converted from 3-prong to 4-prong, standard US 30AMP circuit. I've watched like 30 videos and everyone seems to claim 240V is either RED or ORANGE, and showing a FLAT wire. I have a single Romex BLACK, ROUND 10/3 wire (2 white/black hot, 1 ground, and 1 neutral bare wire) coming into a 1-gang old metal box (is this legal?). I am in the US/North American (NJ state). I simply want to move the receptable down lower on the wall out of sight, i.e. extend the Romex a foot or two inside the existing drywall, using up-to-date code and the correct type of cable, connector, and junction box(es). Please explain: 1) Why is my 10/3 a BLACK cable, and round not flat RED or ORANGE? Is this just common in older construction, or was the wrong type of cable used all the way back to the circuit breaker? 2) What is the difference between Romex 10/3 300V vs. Romex 10/3 600V, which are currently the only ones still being sold at Home Depot. No sign of any red or orange 10/3. Are these ROUND BLACK cables still current and OK to use inside drywall (like what appears to be there now), or is that the older style, for outdoor use, or some application? When did they switch from red or orange to black, and flat to round, or vice versa? 3) Does it matter whether I use 300V or 600V? What is the typical application for each? (I've googled till I'm blue in the face...can't find ANY videos talking about this anywhere!!) Is 600V just overkill? What is that typically used for? Would it hurt anything to use 600V in a 300V application (ie either fine for an electric dryer 240 30AMP circuit), or is it bad to use a higher rated voltage wire for any reason? 4) What is the proper size ELECTRICAL / JUNCTION box for a 30AMP Dryer 240V circuit with a METAL BOX (ground screw in box)? Except for yours, 90% of the 4-prong dryer outlets stocked at Home Depot and almost every video on RU-vid seem to show people installing these newer 4-prong dryer outlets into 1-gang boxes. Even the receptable instructions itself claim "Do not install in 1-gang" yet the plate itself is sized for 1 gang (only two screws top and bottom, like on a normal light switch)! What is the code for 240A? 1-gang or 2-gang? Why are the majority of outlets sold with a 1-gang plate if the box is supposed to be 2-gang? 5) What is the code and safety requirements to SPLICE and EXTEND the cable inside existing drywall? I read somewhere code says you can't have a junction box behind drywall. So do I need to actually REMOVE the existing junction box, splice all 4 wires including ground using push-fit or butt connectors to extend the cable inside the drywall, then leave that cable there loose in the wall outside of a junction box, just to relocate a new metal outlet box 2 feet lower with an outlet on it? Is it OK to drywall over the existing spliced section? (This seems a lot more unsafe to me than just leaving the spliced section inside the existing metal junction box, and then extending on down to the next one.) Thanks if you can help. Will vote up the video...because I can't find these basic answers anywhere! Thanks
@tacoma5964
@tacoma5964 5 лет назад
Where do ur wires the white on the breaker ?thanks
@travismeyers5087
@travismeyers5087 4 года назад
Neutral bus bar in breaker panel.
@ncinteriorsplus3520
@ncinteriorsplus3520 Год назад
Need the panel box installation too. I was expecting the whole instruction of complete installation.
@HandyTim
@HandyTim Год назад
So 2 12-3 wires won't work?
@norcaloutdoor5462
@norcaloutdoor5462 Год назад
how come my dryer outlet only has 3 pins
@ReyShady05
@ReyShady05 3 года назад
Just moved to new house and my new dryer chord only is a 3 prong. So I am running 10/3. I bought a 3 prong dryer receptacle. I am using a metal box. Do I ground the ground to the box? Because the receptacle doesn't have a spot for the ground?
@tedlahm5740
@tedlahm5740 2 года назад
The NEW DRYER came with a 3 prong chord?
@robertobronson8345
@robertobronson8345 5 месяцев назад
Where do the other 2 wires go on the other end you showed 4 wires 0:35
@simplewick350
@simplewick350 4 года назад
Is there a reason for having the ground face up vs down?
@leadupont1895
@leadupont1895 4 года назад
I learned in school that having the ground facing up is just like a safety precaution say if the faceplate somehow fell off and hit the ground screw it could cause problems but if the ground is facing up there’s no chance of that happening. Idk that’s not exactly the technical answer but that’s what I remember! :) Same reason as why when your installing receptacles sideways the neutral side should be facing upwards
@simplewick350
@simplewick350 4 года назад
@@leadupont1895 Then why do we install all other standard home receptacles with ground facing down.
@leadupont1895
@leadupont1895 4 года назад
SimpleWick I’m not sure! I go to a trade school and our shop teacher always tells us do what the homeowners asks for, and if they have no preference then grounds up it is. I suppose it doesn’t do much extra protection and likely is just a little trick people like to do.
@simplewick350
@simplewick350 4 года назад
@@leadupont1895 Yeah that's probably just it.
@ReyShady05
@ReyShady05 3 года назад
There is no code for installing grounds on top or bottom. It's preference.
@rbcbronc6593
@rbcbronc6593 4 года назад
Never showed where the neutral went in the panel.
@tedlahm5740
@tedlahm5740 2 года назад
Where every neutral goes?
@jab2ez
@jab2ez 3 года назад
What would you do for the 3 prong dryer outlet? Is everything the same?
@tedlahm5740
@tedlahm5740 2 года назад
not on new construction since 1996..
@jab2ez
@jab2ez 2 года назад
@@tedlahm5740 Ah so no new 3 prong. Noted.
@MySpace662
@MySpace662 6 лет назад
You failed to mention that this circuit is for 240 V/120 V Dryers.
@MrLucifuge1973
@MrLucifuge1973 4 года назад
Of course it is for 240v. Why would you need to hook up a seperate receptacle for a normal every day plug?
@danadouglass9028
@danadouglass9028 5 лет назад
I have red white and black wires no neutral
@shuumai
@shuumai 5 лет назад
White is neutral. Black is hot. Red is hot. Green or bare wire is ground.
@Cdmxforever
@Cdmxforever 3 года назад
White is neutral! Better call an electrician. ....
@danadouglass9028
@danadouglass9028 5 лет назад
I have only 3 wires
@anon31415
@anon31415 5 лет назад
Check out videos "converting 3 wire dryer outlet to 4" or "3 prong to 4 prong"
@LostTechnologiez
@LostTechnologiez 5 лет назад
don’t tighten your screws to tight !
@adamsilva280
@adamsilva280 6 лет назад
95 percent of electrical connections are over torqued...only 7lb/in needed ...just busting chops here haha
@everythinghomerepair1747
@everythinghomerepair1747 6 лет назад
Adam Silva Better over torqued then under torqued!
@joeybenain92
@joeybenain92 2 года назад
Your orange cable looks like it already has black white red and ground wires, at what point did your yellow (ground) cable merge into the box. You lost me there
@Cskyle22
@Cskyle22 11 месяцев назад
Working with a ring or any jewelry is a no no…. 😮
Далее
МЕГА ФОКУС С ЧИПСАМИ
00:42
Просмотров 163 тыс.
EVOLUTION OF ICE CREAM 😱 #shorts
00:11
Просмотров 6 млн
Changing a 3 Prong Dryer Outlet to 4 Prong
4:51
Просмотров 88 тыс.
HOW TO: Replace a Dryer Outlet
6:49
Просмотров 259 тыс.
How to Install 3 and 4 Wire 240 Volt Dryer Cords
6:29
Просмотров 757 тыс.
МЕГА ФОКУС С ЧИПСАМИ
00:42
Просмотров 163 тыс.