How to Install an EV Charger - Legrand Hardwired Level 2 EV Charger 

Mad Electrician
Подписаться 56 тыс.
Просмотров 75 тыс.
50% 1

How to install a hardwired level 2 EV charger from Legrand. In this video I give a very thorough explanation on how to install the this EV charger. The Legrand hardwired level 2 EV charger is a fantastic EV charger and I highly recommend checking it out!
Link to Legrand Hardwired Level 2 EV Charger:
www.legrand.us...
► MY WEBSITE
-MadElectrician.com
► ELECTRICIAN TOOLS, GEAR, BOOKS, ETC.
-Troll Co. Clothing (10% off using code MAD10): bit.ly/madelect...
-Tutoring and Books: store.upstryve...
► FOLLOW ME
-News Letter: MadElectrician.com
-Instagram: ...
-TikTiok: www.tiktok.com...
-Link Tree: linktr.ee/MadE...
Thanks for watching!
Cheers!
#electrician #evcharger #legrand

Опубликовано:

 

26 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 153   
@jamesparthun3529
@jamesparthun3529 6 месяцев назад
Great Video. One thing to check You need to check breaker 1a,1b. The original wires were on breaker 1&3 (A&B). When you put in the tandem breaker you landed them both on A Phase 1a,1b. If it’s sharing the neutral on a network it needs to be on different phases so you don’t overload the neutral.
@enriquehamilton5693
@enriquehamilton5693 4 месяца назад
A new apprentice here how can you check the neutral ? Thanks in advance
@bryonraisch4673
@bryonraisch4673 Месяц назад
@@enriquehamilton5693 you can see coming out of the romex that it only has one neutral. Therfore cant be on the same phase!
@taylormills08
@taylormills08 7 месяцев назад
Great video! Your procedure of fishing the conduit up the wall is GOLD! No drywall work! Cord under the garage door is questionable if you were in a cold climate. Thanks for sharing your expertise!
@dempower
@dempower 11 месяцев назад
This was an awesome video, I really enjoy this type of content.
@MadElectrician
@MadElectrician 11 месяцев назад
Thanks! That’s great to hear! I haven’t posted much “How to install” type content yet but this was a fun one! I’m definitely open to posting more videos like this ⚡️
@FergusonElectric
@FergusonElectric 11 месяцев назад
post more service calls/home upgrade videos
@TrendyStone
@TrendyStone 2 месяца назад
Very well done! I had to install two Tesla Wall connectors in my garage and the process is nearly identical. Thanks for the helpful video.
@surferdude642
@surferdude642 2 месяца назад
I would prefer to have the holster and coiled cable mounted inside the garage. The way it's currently mounted it will interfere with the garage door when the charger is not in use, plus it's subject to weather and tampering. You could have mounted it on the front to eliminate garage door interference, but the weather and possible tampering issues would still exist, and it could be a bit unsightly. Mounting it inside means that you have to open the garage door to use it, but it's a better option imo since opening it is entering a code and pushing a button. The only other nitpick is that the conduit body is not really fastened where it enters the wall. A strap near that end could resolve that issue. Overall, it still looks pretty well done.
@PeaceChanel
@PeaceChanel 7 месяцев назад
Thank You for All that you are doing for our Planet Earth.... Peace.. Shalom.. Salam.. Namaste 🙏🏻 😊 🌈 ✌ ☮ ❤
@b3arwithm3
@b3arwithm3 Месяц назад
Great tutorial. Very clear and detailed. I didn't get what the role of the junction box is. Can't we run a wire straight from the panel to the charger?
@GEORGEMONTEVERDE
@GEORGEMONTEVERDE Месяц назад
Thank you for your very informative video. I gather you did this connection to charge your EV, OUTSIDE the garage. My newbie friend has a standard wall plug the electrician ran from the Dryer Circuit from inside the house when they build the new garage. I personally feel this upgrade was done on the cheap and charged top dollar. I warned my friend that the wires were getting too hot and to remove an extension cord and go right into the wall plug.
@ChelsMoClark
@ChelsMoClark 11 месяцев назад
Please please please upload more, LOVE your videos 😊
@MadElectrician
@MadElectrician 11 месяцев назад
Thanks, Chelsea!! I definitely intend to! I’ve been pretty busy working on a lot of behind the scenes stuff for Mad Electrician lately but am now getting back into the rhythm of creating more content again. Thanks for the encouragement and thanks for watching! ⚡️🤘🏼⚡️
@williamgrissom9022
@williamgrissom9022 3 месяца назад
An advantage of hard-wiring vs using a charger w/ plug is that you need only run 3 wires - 2 hots and gnd, with no neutral since chargers don't need it. A 4-wire plug has a neutral terminal, though perhaps you could not wire it if only an EV charger would be using that plug, that would seem strange. Good for me since I have a 50 A 240 VAC wire to a former electric oven, so can re-purpose that long cable for future EV charging by terminating it in a box and continuing conduit to the nearby garage to a box for future hard-wiring. That cable had no neutral wire, which surprised me until I found typical, at least in the past, for large appliances like stoves and clothes dryers. A 2nd reason for not using a plugged charger is that the latest NEC code requires an outlet to have GFCI protection. A 3rd reason is that plugs can give resistance to melt and cause a fire. Re the video, I'm surprised your local code allows using a wire-nut to connect ground wires. I thought one had to twist the wires and use a copper crimp, though I've seen many youtubes wiring overhead lights where they use a Wago lever connector on the ground wires (to code?).
@carlosberrioselectrician777
@carlosberrioselectrician777 11 месяцев назад
💯Safe and clean work🙏 👋Greetings from Orange City Florida 🐊 😎✌️
@MadElectrician
@MadElectrician 11 месяцев назад
Thanks! I appreciate you taking the time to watch! ⚡️🤘🏼⚡️
@hjlee303
@hjlee303 9 месяцев назад
It is such a great and much detailed vid on how to. Thanks a lot. I think I am ready to install mine fir the new BMW i4. Happy holidays!
@alexsanoff585
@alexsanoff585 11 месяцев назад
Awesome video! Very clear and easy to follow, thanks for explaining the entire process. I would love to apprentice under someone like you once I get into the apprenticeship! Keep it up and thanks for posting this quality content ✌️
@hrguille
@hrguille 2 месяца назад
Than pannel cover needs some paint. Thanks for the video. Great hack on the tandem 15amps
@lohmiperez5258
@lohmiperez5258 Месяц назад
Very detail instructions. Good Job!
@shshshs2
@shshshs2 11 месяцев назад
This was a great video. You lucky your wife don’t mind the pipe. My didn’t want to see a pipe so I had to open up the wall and get my carpenter friend to put it back up
@MadElectrician
@MadElectrician 11 месяцев назад
Thanks! I enjoyed the installing part but it was tricky setting up my camera and light for every shot 😂 I actually really considered doing that but I wanted to do “simpler” install for the video. That’s definitely the cleaner route to go though ⚡️🤘🏼⚡️
@borismcgiver7764
@borismcgiver7764 5 месяцев назад
Great Detailed, and nice clean work and very concise explanations . Much appreciated this. Thanks.
@ricodinero4926
@ricodinero4926 8 месяцев назад
Dude you're the Man! great vid.
@MadElectrician
@MadElectrician 8 месяцев назад
Thanks!! Glad you enjoyed the video! ⚡️🤘🏼⚡️
@standtall7646
@standtall7646 8 месяцев назад
Great video, Steven! Clear, great speed of explanation and clear on materials/tools used/needed. I'll save this video as reference. I'm a general/Handyman and I have wired in e few EV Charger receipts. Ive wired in many dryers(Yes electrical :). Thanks, for this video. Where did you purchase the Adjustable Pliers and the Strippers with Flat end?
@johnpayton4633
@johnpayton4633 3 месяца назад
Great detail explained. Thank you brother
@MadElectrician
@MadElectrician 3 месяца назад
Glad you found this useful! Thanks for watching!
@samisaadedin6797
@samisaadedin6797 6 месяцев назад
👏👏👏 only issue i would have i imagine is my garage door would just open on it's own cuz there's resistance from the hose
@Matthew-tb7cc
@Matthew-tb7cc 11 месяцев назад
#8 ground? Could have gotten away with a #10 just an fyi. Great video tho keep em coming.
@robbe8858
@robbe8858 11 месяцев назад
Nice video! Very detailed and thorough step by step .Thanks .
@antoniojones1356
@antoniojones1356 11 месяцев назад
Craftsmanship superb makes me excited as an apprentice
@AK-qo6tx
@AK-qo6tx 11 месяцев назад
How are you closing the garage door with the charger mounted on the outside of the garage?
@miguelrodfher
@miguelrodfher 8 месяцев назад
Exactly what I was going to ask! Seems that is possible, but no one makes a video about it
@allencharbonnet8585
@allencharbonnet8585 6 месяцев назад
That’s exactly what I was thinking.
@samisaadedin6797
@samisaadedin6797 6 месяцев назад
He lives in a very safe area
@S777H
@S777H 6 месяцев назад
No response to this question?
@samisaadedin6797
@samisaadedin6797 6 месяцев назад
Guys, if you actually took the time to watch the video you would have an answer, he literally says, you can close the garage door no problem. 19 min 50 seconds. Thank you
@Jomanscool2
@Jomanscool2 10 месяцев назад
Is the top breaker not feeding a MWBC? That'd be two 15 amp circuits, same phase, with one neutral, potentially overloading the neutral. Could be remedied by putting it on the other tandem, though you should also have a handle-tie I think?
@jakerasp
@jakerasp 6 месяцев назад
How do you know they share a neutral?
@gargolart
@gargolart 4 месяца назад
Is the handle tie necessary even if the same circuit is connected to different fase?
@Jomanscool2
@Jomanscool2 3 месяца назад
@@gargolart Handle ties are so the entire wire is dead. If you are running 12/3, which we can see that top breaker goes back to Romex with one white, a black, and a red, so it’s 12/3 or 14:3, and you have a MWBC, so two separate hot phases, and a common neutral, if you shut off one hot phase, current is still running on the neutral, and on the other hot, so it’s not safe to work on receptacles or switches on the “partially shut off phase”. We can see both phases were in use previously via a MWBC on a single Romex wire, and it was unsafely merged onto a single phase with a tandem breaker providing 15A on each hot, and a potential 30A (or 20/40A respectively for 12AWG), which can overload and overheat the neutral conductor. My understanding when moving circuits to tandems is you need to look at panel capacity, service capacity, and MWBC, and this video failed to look at the last.
@jeffjackson6358
@jeffjackson6358 28 дней назад
Next time show/tell your viewers they should torque their lug points to the specified torque amount shown on the breaker. Also, why not just run continuous wire from the breaker to the charger and eliminate the wire nuts? Improper wire nut tightening will result in a big problem. You are just adding a fail point for no reason. Unless the charger did not allow you to open it and attach longer wires. Otherwise loved the video!
@erictorbet8104
@erictorbet8104 4 месяца назад
Thank you, very clear. If it were a new home and dry wall wasn't there yet, I presume you would not use conduit and just run the wires inside the wall?
@GlenMacNeil
@GlenMacNeil 8 месяцев назад
Do you torque your connections at the panel?
@mathewshoyt1763
@mathewshoyt1763 13 дней назад
i would have left the cord inside the garage to prevent any damage to the cord and garage door as well as having anyone drive up your drive way for a free charge when no one is home. hope you put a disconnect later after this video. great video though
@loucinci3922
@loucinci3922 5 месяцев назад
If that panel wasn’t bonded, where would you land the ground wire? Assume on ground bar. Would you then have to run a common too?
@surferdude642
@surferdude642 2 месяца назад
If this was a sub panel, then yes. The hot wires would be connected to the double pole breaker the same way and the breaker would be in the sub panel.
@jhseam
@jhseam Месяц назад
Great video. It's easy to setup. If i have the toolkit i hope i can also do that 😅
@polepole9066
@polepole9066 6 месяцев назад
Thanks so much for this. It will help me install ours when we pull the trigger on an EV. Question: I will need about 25 ft of cable length from the charger to the car because I can’t park close to the garage (slope/winter). Do I lose efficiency by having a longer charger cable ? Or should I run underground wire closer to the car parking location. And mount the charger outside ? Cheers mate 🥂
@erikkarling2176
@erikkarling2176 10 месяцев назад
Nice, clean work.
@rtsolution11
@rtsolution11 5 месяцев назад
Curious if you have changed the location of the charging cord dock? All but that, and what James mentioned below I liked.
@dougsprelude1
@dougsprelude1 11 месяцев назад
Good job sparkie
@MadElectrician
@MadElectrician 11 месяцев назад
Thanks! ⚡️🤘🏼⚡️
@Antiorganizer
@Antiorganizer 9 месяцев назад
rrrrrrrrrrrrrrrrrrrrrrrr
@Dianfarida-g9n
@Dianfarida-g9n 7 месяцев назад
What size of wires did you hardwire ,? What brand did you choose? What brand is the 60 amp breaker?
@Fetecheney
@Fetecheney 5 месяцев назад
Late reply, but it should be #6 AWG wire. You can buy it as sheathed Romex where all the four wires are in a rubber sheathing, or you can buy the stranded wires individually but you have to make sure that you run them in conduit so they're protected. It's a lot safer to put them in metal conduit. Make sure you keep doing your research but hopefully this gives you a starting point. If you did need to know what size they are. Also, if anyone sees this and knows otherwise, please chip in
@shawnwinget2337
@shawnwinget2337 Месяц назад
I am considering a Honda Prologue. My panel is at the front of my garage about where you put your charger so it would be right next to the panel. Can the wires from the charger be wired directly to the breaker in the panel? My panel is flush like yours.
@brothermanvlogs3767
@brothermanvlogs3767 11 месяцев назад
Can you please do a video on how to prepare for and take the state exam 🙏🏽
@zhongmingwu
@zhongmingwu 8 месяцев назад
i have 200amp panel with all 30 breakers used up. One company give me an estimate with your solution involving tandem breaker with about $1400 quote. Two others insist to install a subpanel next to it with $2700 to $3500. Now that i have seen your work i feel good that first solution is not really wrong. anyone know why two companies insist on new subpanel; one of them didn't even visit though he did work on my house 3 yrs ago. i am in dallas and google does not say that i need a permit but one company says that i need it very good video ❤
@loucinci3922
@loucinci3922 5 месяцев назад
Great video. Thanks for sharing
@jerrypruden887
@jerrypruden887 10 месяцев назад
Good content but you were measuring voltage and saying amps?
@MadElectrician
@MadElectrician 10 месяцев назад
Thanks! Which part are you referring to? When I was measuring voltage I was mentioning 240v between phases.
@ldiamond3290
@ldiamond3290 25 дней назад
​@@MadElectrician7:28
@ldiamond3290
@ldiamond3290 25 дней назад
Btw passing the cable under the door is against code in most places.
@tylerc4700
@tylerc4700 10 месяцев назад
i just joined the field 4 weeks ago and i want to find a great book for exam prep and training. im finding books on amazon but the reviews are all mixed and i struggle to find a book thats has good information. are there any training books that you recommend? i am in the residential field in the seattle area. thank you, your videos have taught me so much!
@tomballman5243
@tomballman5243 3 месяца назад
GREAT VIDEO!! My only question is, how can you close your garage door?? LMAO!!
@kennethreddy5749
@kennethreddy5749 2 месяца назад
Straps are installed wrong. Screw holds the pipe up not the strap . Very important in commercial. Other than that I would’ve just used black taps/clear taps . Big blues no if it was my own house
@MccormickJr
@MccormickJr 5 месяцев назад
For the flexible metal conduit in the wall to the panel, don't you have to properly ground/bond it to the panel? Such as a grounding bushing or bonding locknut?
@The360Electrician
@The360Electrician 11 месяцев назад
Great video as usual. Evergreen content here!
@MadElectrician
@MadElectrician 11 месяцев назад
Thanks! Just trying to make you proud, Jeff 🥹
@yeminacci
@yeminacci 5 месяцев назад
Great work. Very clean. But the charger rack for the cable? How do you close the garage 😮
@alexxp503
@alexxp503 8 месяцев назад
watch out with that multibranch circuit bro!!!!! You should kw that already (overload neutral)...... booooom
@apwelsh
@apwelsh 8 месяцев назад
So, red and black are L1 and L2. Was green neutral or ground? If ground, why didn’t you ground the j-box?
@MadElectrician
@MadElectrician 8 месяцев назад
Black - L1 Red - L2 White - Neutral Green - Ground I did bond the ground to the j-box 👍🏼
@apwelsh
@apwelsh 8 месяцев назад
Sorry. I thought I only saw 3 wires in the video, and must have missed the grounding.
@apwelsh
@apwelsh 8 месяцев назад
Definitely only seeing 3 wires. So that charger doesn’t need neutral.
@don1estelle
@don1estelle 10 месяцев назад
Grate Job exept those old Wire Nuts shurly there is a better Solution!
@MadElectrician
@MadElectrician 10 месяцев назад
Thanks! The wire nuts are fine and legal, but there is a better, probably more mechanically sound solution. I could have used small Polaris lugs. They take up a little bit more space but will never come undone. They are just more expensive and I didn’t have them on hand when making the video.
@sedona1234566
@sedona1234566 9 месяцев назад
Definitely, they are compliant but with that load and length of time it is pulling a full load I would recomeend a type of crimp or mechanical connector.
@don1estelle
@don1estelle 10 месяцев назад
They should make a gard plate to protect you from the live wires.
@matta5160
@matta5160 10 месяцев назад
Not sure why they don’t UK fuse boxes (the more modern ones) usually have a plastic cover for the incoming wires.
@don1estelle
@don1estelle 10 месяцев назад
It would that seem nearly US power pannels seem to have bare wires in them, electricians nead to carry a temporary plastic barrier plate to make it safer when working inside one.
@ken62310
@ken62310 Месяц назад
doesn't that block your garage door?
@darwinfussle5031
@darwinfussle5031 7 месяцев назад
Always use a regular hammer 🔨 to punch a hole. Not a hole saw or a screw driver. It can be easily patched once your finish....i suggest this method it takes a neat hole no dusk no debris.
@Dianfarida-g9n
@Dianfarida-g9n 7 месяцев назад
Legendary video!!!
@MadElectrician
@MadElectrician 7 месяцев назад
I’m glad you think so! Thanks for watching! ⚡️
@Dianfarida-g9n
@Dianfarida-g9n 7 месяцев назад
@@MadElectrician one question I have though is how to call an inspector? Do they charge money ?
@jmahtab
@jmahtab 9 месяцев назад
Just curious why you chose to use fmc from the box to the lb instead of seal tight like you used from charger to the 4 11/16 box? Nice clean install.
@rayzinz5938
@rayzinz5938 7 месяцев назад
How would this install change if you were to mount the EVSE (charger) on the outside of the wall? I assume you'd probably want to run the liquid tight conduit through the wall but you'd also want to do something to prevent water getting into the wall. Thoughts? Also, do you have to change the ampacity or pick a different temp rating for that THHN while running in the liquid tight conduit?
@DiegoVargas3773
@DiegoVargas3773 11 месяцев назад
Hey Steven I just applied for limited residential 2.5 and got a ranking of 382 is that good?
@Dianfarida-g9n
@Dianfarida-g9n 7 месяцев назад
Hello could you please let me know if we can use #6 white in place of #6 black? And will it be an overkill if we use all #6 thhn red, black and green wires ?
@taylormills08
@taylormills08 7 месяцев назад
By code you are not to re-phase conductors unless they are 4awg or larger. 6awg and smaller should be color phased from manufacturer. You must buy colored conductors according to NEC.
@rj-zn3cw
@rj-zn3cw 3 месяца назад
Both, you and Legrand seem pretty "generous" if you know what I mean... wink wink
@FishFind3000
@FishFind3000 11 месяцев назад
6:30 just gotta be carful with those tandums. The panel needs to be rated for their use and location.
@MadElectrician
@MadElectrician 11 месяцев назад
100% ⚡️
@briandillard8125
@briandillard8125 8 месяцев назад
Does the top tandem have both conductors from multi wire branch circuit terminated to it?
@k20909
@k20909 8 месяцев назад
A gfci breaker is not required?
@MadElectrician
@MadElectrician 8 месяцев назад
Nope! I actually specifically asked my local inspector about that before doing this install and he said no.
@TrendyStone
@TrendyStone 2 месяца назад
I know the Tesla Wall Connector specifically says NOT to use a GFCI. The reason is that it is already built into the car and an additional GFCI may cause problems.
@barriepkr
@barriepkr 11 месяцев назад
Current equals voltage / resistance. The same amount of current will pass through you touching a main lug as it would a regular outlet. Why are people so scared of panels
@MadElectrician
@MadElectrician 11 месяцев назад
Good ol’ ohm’s law baby. A couple of reasons, though definitely not all: It’s very easy to make a mistake and touch a main lug working in an energized panel, especially for someone who isn’t very experienced. It would be easier to get hung up or be in an arc flash/ blast situation vs just by working on a regular outlet. There’s the potential of a phase to phase to short, resulting in a very high fault current. Etc. Thanks for watching!
@cynthiaayers7696
@cynthiaayers7696 3 месяца назад
At home charging systems should come with the price of the vehicle.
@deas1anguy
@deas1anguy 8 месяцев назад
Couldn’t you just run emt straight to the ev charger?
@MadElectrician
@MadElectrician 8 месяцев назад
I could have but it wouldn’t have been where I wanted the charger mounted and I also wanted my EMT to be ran down low so that it wasn’t taking up too much wall space. This was more work but I’m happier with the placement of everything.
@zebadiahsprenkle8395
@zebadiahsprenkle8395 2 месяца назад
Thats a whole lotta vamps
@faheemuddina
@faheemuddina 13 дней назад
Easy peasy lemon squeezy. Csgo much?
@surferdude642
@surferdude642 2 месяца назад
60 amp breaker? Should be 50 amp with 6 gauge wire.
@MadElectrician
@MadElectrician 2 месяца назад
@@surferdude642 It’s considered a continuous load (operating for minimum of 3 hours at max current). 48A x 1.25 (multiplier for continuous loads) = 60A.
@surferdude642
@surferdude642 2 месяца назад
@@MadElectrician Shouldn't the wire be 4 gauge then? Personally, I'd be more comfortable with a 50 amp breaker and from what I understand, no EV is going to draw close to that much current anyway.
@surferdude642
@surferdude642 2 месяца назад
​@@MadElectricianI understand the 1.25 multiplier and how you arrived at the 60 amp breaker. I did some research and your charger I believe is rated for 48 amps and THWN wire is apparently rated for 65 amps, so you are correct. My concern is using wire nuts for this much current allowance. I would prefer using terminal blocks rated for 60 amps for the hot wires.
@goosfraba911
@goosfraba911 3 месяца назад
Why didn't you pull all the way through instead of splicing?
@MadElectrician
@MadElectrician 3 месяца назад
I would have much rather done that but the internal terminations weren’t designed to be undone. I didn’t want to mess with the listing of the car charger either. Also, this was a video that I partnered with Legrand to make and I wanted to show how someone would do an installation the way that they designed it to be done. The best situation would be going right into the side or bottom of a surface mounted panel without needing to use any extra wire. That just didn’t work for my situation unfortunately.
@MrAcruz2
@MrAcruz2 5 месяцев назад
great video, hows the garage door gonna close if u have it in the way like that ?
@Fetecheney
@Fetecheney 5 месяцев назад
Cut a 1½" slot in the garage door from about 4' to the ground. Piece of cake.
@cadelawlor3457
@cadelawlor3457 11 месяцев назад
So how much do you make as an electrician
@chad10006
@chad10006 11 месяцев назад
They typically charge $150-$200 per hour.
@Hatim.13
@Hatim.13 11 месяцев назад
He is part of Local union 46, so as an employee he makes 70$/H (140k) on the check + benefits (different retirement plans, medical, dental, vision...) Total package is around 97$/H.
@jamieeisenhower1560
@jamieeisenhower1560 4 месяца назад
😂 my question is how you going to shut the garage door
@MadElectrician
@MadElectrician 4 месяца назад
It doesn’t affect the garage door at all. There’s unfortunatly a slight gap already in that corner so this fits right underneath without getting smashed.
@fordsrmaster
@fordsrmaster Месяц назад
I take it that charger didn't use a neutral.
@kikodelacruz96
@kikodelacruz96 11 месяцев назад
Will a neck tattoo affect my interview for the apprenticeship?
@mikenormandy9250
@mikenormandy9250 10 месяцев назад
It should not BUT with that said, you cannot rule out people’s own opinions and judgments- so maybe hold off until you get in! Good luck!
@chief5981
@chief5981 10 месяцев назад
Yeah. If you don’t have at least 1 neck tat and 1 felony they probably won’t take you serious. You’re applying to a trade not a bank.
@MWorsa
@MWorsa 5 месяцев назад
A generous 3 feet 😂
@vladbagdasarov1672
@vladbagdasarov1672 3 месяца назад
50 amps of constant current for 8 hours daily, I don't know if I'd trust those wire nuts.
@surferdude642
@surferdude642 2 месяца назад
Most of the EV's allow the user to select the current draw and/or they max out at 35 amps or less. Still, 6 gauge wire and a 50 amp breaker is appropriate.
@vladbagdasarov1672
@vladbagdasarov1672 2 месяца назад
@@surferdude642I think you misread, the wire is appropriate, the wire nuts on the other hand is sketch.
@ldiamond3290
@ldiamond3290 25 дней назад
240 amps? 😬
@MadElectrician
@MadElectrician 25 дней назад
@@ldiamond3290 Did I accidentally say 240 amps somewhere?
@ldiamond3290
@ldiamond3290 25 дней назад
@@MadElectrician 7:28 I'd be stressed out dealing with a 56kw device.
@MadElectrician
@MadElectrician 25 дней назад
@@ldiamond3290 Shoot, I definitely misspoke 😅 Good catch! I think you’re the first person to point that out. I didn’t even catch that while editing this.
@davidmerkrebs9967
@davidmerkrebs9967 3 месяца назад
don't understand the cord under garage door there had to be a better way totally not professional
@MadElectrician
@MadElectrician 3 месяца назад
It’s a little weird for sure. It’s at my house though, not somebody else’s. This is also for charging a car in the driveway, not in my garage. The best place to mount the charger was in the garage (no good spaces anywhere outside my garage). There was also a gap under my garage door which this cord has no affect of. At the end of the day, this made the most sense to me for my situation. It’s been over 6 months of it being like this with no issues and no marks or anything on the cable. I also saw somebody else in my neighborhood do the same thing and it worked great for him with no issues. I can always put the cord holster in the garage if I ever want to move it in the future.
@hillppari
@hillppari 8 месяцев назад
why tf would you put the holster outside????
@MadElectrician
@MadElectrician 8 месяцев назад
Most of the time my garage door is shut, and it’s rated to be installed indoor or outdoor. I don’t want to open my garage door every time I need to charge and any car I charge will be parked in the driveway.
@stevekight1955
@stevekight1955 6 месяцев назад
Does it make any sense to show people how to do your job? When you're out of work, maybe you can watch plumbing videos and learn a new trade.
@MadElectrician
@MadElectrician 6 месяцев назад
It sure makes sense to me ⚡️🤘🏼⚡️
@h7opolo
@h7opolo 5 месяцев назад
you should've showed the ground wire connected to the ground bus after you were done wiring the 60A breaker. the fact you omitted proof of this most crucial step undermines the rest of the video which is otherwise painstakingly thorough. this is the method of youtube con artists who falsely pretend to have expertise.
@MadElectrician
@MadElectrician 5 месяцев назад
Can’t remember to film everything my friend. I think it can be safely assumed that since I pulled the wire it got landed. Not sure how accidentally forgetting to film landing the equipment grounding conductor makes me a con artist by any definition of the word, or not an expert. Pretty sure it just makes me human.
@MadElectrician
@MadElectrician 5 месяцев назад
Hilarious dude, I did show myself landing the ground wire and I even mentioned it. I just assumed that since you made such a big deal about it I forgot, but lo and behold, here it is. 23:45
@Mohammad-bq5hh
@Mohammad-bq5hh 7 дней назад
That was great
@Mohammad-bq5hh
@Mohammad-bq5hh 7 дней назад
Is it ok to use Number 2 or 4 or it has to be number 6?
@DailyElectrician
@DailyElectrician 11 месяцев назад
Lets gooooooooooooo
@MadElectrician
@MadElectrician 11 месяцев назад
⚡️🤘🏼⚡️🤘🏼⚡️
@beltrams
@beltrams 2 месяца назад
Dirty, stained panel covers drive me crazy. You need some grey spray paint 🙂
@jamesking6174
@jamesking6174 5 месяцев назад
Is it a bi directional charger.
@freshgino
@freshgino 5 месяцев назад
Great job, keep up the good work
@leedaq7767
@leedaq7767 5 месяцев назад
how is the owner closing the garage door?
@MadElectrician
@MadElectrician 5 месяцев назад
This is my house. I didn’t explain it in this video but there was an existing gap in the corner of my garage door that the cable fits under without being squished. Not a great solution but it works fine in my situation.
Далее
How Many Amps Do You Need For Home EV Charging?
26:08
Просмотров 476 тыс.
Офицер, я всё объясню
01:00
Просмотров 2,4 млн
Новый вид животных Supertype
00:59
Просмотров 74 тыс.
How to Install an Electric Vehicle Charger Receptacle
14:27
How A Top Gear Review Made Tesla Sue Jeremy Clarkson
14:51
Hubbell NEMA 14-50 is TOO EXPENSIVE! Do this instead.
6:56
EV Charging Disaster
9:11
Просмотров 447 тыс.