Тёмный

How To Install an Outside Socket | External Plug Installation Guide 

The DIY Guy
Подписаться 320 тыс.
Просмотров 179 тыс.
50% 1

Welcome to my tutorial on how to fit an external power point. In this video I'm going to show you how I fit an outdoor socket step by step. If you like the content leave a like and please subscribe for more content like this.
My Shop: 🛒 My Shop -www.amazon.co.uk/shop/thediyguy
Check out the other videos on my channel and like and subscribe for more!
► BECOME A MEMBER OF THE DIY CLUB Click! 👇🏼
/ thediyguy1
► Get FULL access to the Discord Group and other perks!
Follow me on Instagram 👉 the_diy_guy_youtube
Thanks for watching The DIY Guy. My mission is to bring you the best Tips, Tutorials and Tools to help you learn and save money.
Please be advised that this is only a guide which is intended for informational, educational and entertainment purposes and The DIY Guy cannot accept responsibility for any work undertaken. Be safe and have fun! The Amazon links above are affiliate links and as an Amazon Associate I earn from qualifying purchases. I may earn a small commission if you purchase via the recommended links, however this will not cost you any extra.

Опубликовано:

 

8 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 229   
@walkerrobinson9614
@walkerrobinson9614 3 года назад
An excellent teacher you are. Straight to the point, clear explanations, breaks things down. Better job than many teachers out there.
@TheDIYGuy1
@TheDIYGuy1 3 года назад
Thanks,im glad the videos help you.
@41vidbarber
@41vidbarber 10 дней назад
This bloke really knows his stuff. Follow him and you'll save time and do the job safely.
@deborahsharpe6371
@deborahsharpe6371 3 года назад
Very good description of how wire up an outdoor socket. Easy and clear. Thank you. As a diy beginner, I will enjoy following your channel.
@me1love2max
@me1love2max Год назад
Nice one. Thank you. I need an outdoor double socket so I can get power to my greenhouse and so I can plus my mower in outside instead of going through a window or door. I was going to pay somebody to do it for me but this looks super simple... I've fitted electric sockets before but was a tad worried about moisture with an outdoor socket. This has eased my worries of doing it myself. Thanks 👍🏾 😁
@stanley325
@stanley325 6 месяцев назад
Clear instructions, great explanations of why to do something, no ego (ain't I clever) just confidence boost to make me give it a go. Thanks
@shendrew
@shendrew 3 года назад
Very straight forward and to the point. Keep it up!
@ID29794
@ID29794 3 года назад
Brilliant video really easy to follow and clear. Got a nice outside waterproof socket now installed👍🏻👌
@ashvanbro9329
@ashvanbro9329 3 года назад
Always love your vids brother
@Rajjjjjjjjjjjjjjjj
@Rajjjjjjjjjjjjjjjj 3 года назад
Very informative ! Thanks a lot !
@alisdair9
@alisdair9 3 года назад
Your video was very clear mate. Well done. Look forward to more just like it. Good luck 🤞🏻
@TheDIYGuy1
@TheDIYGuy1 3 года назад
Thanks very much
@schmutzlibuab
@schmutzlibuab Месяц назад
I know that this is 3 years old but I followed your instructions today for tge exact same outside socket and am thrilled that I was able to do it tha ks to you 👍 I really enjoy your videos and they have not only helped me do jobs myself but my confidence is growing as well. Thanks DIY King 👑
@TheDIYGuy1
@TheDIYGuy1 Месяц назад
Great to hear! Thanks 🙏
@justjim4711
@justjim4711 3 года назад
very informative and helpful thanks a lot
@hectorheath9742
@hectorheath9742 3 года назад
Nice video, thanks. I have an aversion to knocking nails into masonry, it just don't seem right, but I know that's how the professionals do it. Also my experience of using the plastic clips is the plastic part eventually cracks and splits, so I use nylon 'P' clips and screws.
@jamescutting5589
@jamescutting5589 Год назад
Great video 😊thanks always learning from you 👍
@stevied1125
@stevied1125 Год назад
fantastic video and properly done
@mattissakw
@mattissakw 3 года назад
Great vid very helpful thankyou look forward to seeing more
@TheDIYGuy1
@TheDIYGuy1 3 года назад
Thanks and welcome
@PilbeamMP97
@PilbeamMP97 2 года назад
Spot on thanks - exactly what I was looking for, well presented cheers 👍
@TheDIYGuy1
@TheDIYGuy1 2 года назад
Glad you found it useful 👍
@leeroberts5668
@leeroberts5668 10 месяцев назад
Brilliantly presented Really clear and concise and given me the confidence to tackle the job 👍🏻
@TheDIYGuy1
@TheDIYGuy1 10 месяцев назад
Glad it helped
@a.a.alexander6030
@a.a.alexander6030 2 месяца назад
Thanks for this video. This is exactly the sort of job I want to do but have never tried. Thanks for the ABC style step by step guide. The tools, the method and the 'just how much of a job is it' - those are elements a lot of us look at as it may be a one-off job for many of us.
@TheDIYGuy1
@TheDIYGuy1 2 месяца назад
Glad it was helpful!
@Huntelaar13
@Huntelaar13 2 года назад
Nice video, exactly what I needed. Cheers mate.
@TheDIYGuy1
@TheDIYGuy1 2 года назад
Your welcome, cheers
@peterchiu1979
@peterchiu1979 Год назад
You made this look so easy and gave me confidence to try it! I hope I can locate the cable for my socket behind the back box but I assume that'll be easy
@TheDIYGuy1
@TheDIYGuy1 Год назад
You can do it!
@anthonyoconnell9389
@anthonyoconnell9389 3 года назад
Great job very helpfull keep up the good work ☘️🥃💚👍
@adammunaf5661
@adammunaf5661 3 года назад
Very helpful
@dg-artist
@dg-artist 11 месяцев назад
Very helpful video. Thanks for making it!🙂👍
@TheDIYGuy1
@TheDIYGuy1 11 месяцев назад
Glad it was helpful!
@user-John666
@user-John666 9 месяцев назад
Good job, well explained and although it isn’t exactly what I need to do, (I need to put one out to a decking area)it’s given me a good idea of what’s involved. Thanks
@TheDIYGuy1
@TheDIYGuy1 9 месяцев назад
Glad it was helpful!
@sianwilliams9550
@sianwilliams9550 8 месяцев назад
That's awesome! Thank you! I thought it would be harder to get the electricity to it, but it's so simple! X x
@TheDIYGuy1
@TheDIYGuy1 8 месяцев назад
Glad I could help!
@intothemultiverse1033
@intothemultiverse1033 3 года назад
Greg video mate. Keep up the good fight.
@paulpincher4998
@paulpincher4998 3 года назад
Great video thanks very helpful
@TheDIYGuy1
@TheDIYGuy1 3 года назад
Glad it helped you out!
@pauloroarty1799
@pauloroarty1799 2 года назад
Brilliantly explained.I've Subscibed Thank you
@TheDIYGuy1
@TheDIYGuy1 2 года назад
Thanks, glad it helped you
@marcusregan4815
@marcusregan4815 3 года назад
Good video, very clear
@TheDIYGuy1
@TheDIYGuy1 3 года назад
Glad you found it useful
@Andiiiio
@Andiiiio 4 месяца назад
thank you for all your help
@TheDIYGuy1
@TheDIYGuy1 4 месяца назад
You are welcome!
@Mrsprint90
@Mrsprint90 3 года назад
Hi. I need to drill a hole from my living room to outside. It’s standard drywall then brick work. Would you just cable detect then drill straight though. Thanks
@Tichx
@Tichx 9 месяцев назад
Lovely video, nice and easy to follow.
@TheDIYGuy1
@TheDIYGuy1 9 месяцев назад
Glad you liked it!
@steve11211
@steve11211 3 года назад
If you drill from the outside in at a slight upward angle or inside out at a slight downward angle then no water can get inside. Its not relevant in your case but it should be said that if you come off a ring circuit you can only spur once so you cant spur off a spur. Another tip I would always put an outside socket connected to a fcu, think about this, its christmas day and hammering it down with rain, water has as it always will eventually got into that socket and has tripped the rcd, you have a freezer in the garage that you need but everytime you turn on the garage circuit it trips the rcd. If you have a fcu you can isolate the outside socket so you can deal with it at a later date. I would also run a bead of silicone over the top and sides of the socket just to reduce the chance of any water ingress. You could make life easier for yourself by stripping more of the outer sheathing, there is plenty of room in the socket and you will find it easier to terminate if you leave more of the single insulated conductors in the socket. pull the cable out, measure 3 fingers beyond the box then cut and strip back as much as possible. If you terminate only one cable into a socket it is really better to fold the end of the conductor over so it fills the terminal better which will ensure a better connection.. Finally as a minimum do a zs test and test your rcd to make sure it will trip, no point having an rcd if it wont trip in the required time.
@TheDIYGuy1
@TheDIYGuy1 3 года назад
You certainly know your stuff my friend. If I were working in the house rather than the garage I would certainly tilt the drill bit. This for example is the type of thing I chose to leave out of the video due to length of the video if it were all added in. Believe me, some stuff mentioned in your comment was originally recorded but it's very difficult not to make a long and boring video when you add all of this stuff in. For those of you reading this comment. In the situation(my case) where your circuit is radial you don't need to worry about the maximum spur off(1). Steve however is correct in stating that you should check the RCD. Thanks
@gettingrounderroundthemidd9769
@gettingrounderroundthemidd9769 3 года назад
Good extra tips to a good video 👍
@darknessdestroyer5524
@darknessdestroyer5524 3 года назад
A FCU will reduce the load capacity of the socket to 13A, move the circuit over to the non RCD protected side of the CU and install a 20amp RCBO to achieve discrimination and therefore avoid tripping the RCD protected circuits 👍.
@JB-tc8el
@JB-tc8el Год назад
@@darknessdestroyer5524 either you haven’t thought that through or you have little experience with UK domestic wiring.
@darknessdestroyer5524
@darknessdestroyer5524 Год назад
@@JB-tc8el before I reveal my experience please enlighten me with the problem you see with my proposal.
@jakovfilimonov9698
@jakovfilimonov9698 8 месяцев назад
Smashing! 👌
@rosanadancel7225
@rosanadancel7225 Год назад
Thank you, I lean more.
@g41images70
@g41images70 Год назад
Thanks for your great videos. I want to fit an outside socket for my hot tub. Is it advisable to run a spur from my internal socket to a fused spur point and thereafter wiring the external sockets to the fused spur?
@msmalik681
@msmalik681 2 года назад
absolute legend
@TheDIYGuy1
@TheDIYGuy1 2 года назад
Cheers 👍
@nosycatUK
@nosycatUK 6 дней назад
Hi from 2024. Nice content.
@kcomfortsystemshvac7060
@kcomfortsystemshvac7060 Год назад
Good stuff,,,,mate appreciate,,,,👌
@TheDIYGuy1
@TheDIYGuy1 Год назад
Anytime 👍
@ruthgolding7424
@ruthgolding7424 3 года назад
hi mate how do i do it for double socket 1 either side of the house as all the power is on 1 side only
@elbowtoe84
@elbowtoe84 5 месяцев назад
A fab grand job
@TheDIYGuy1
@TheDIYGuy1 5 месяцев назад
👍
@RossHbn
@RossHbn 3 года назад
Thanks.
@asheu5511
@asheu5511 Год назад
I am installing an external power socket and re-watched your excellent video. One thing, I'd like to check: what is the main reason for using the 15mm barrier pipe? Is it to protect the electric cable from the elements (inside the wall)? Would it matter much if I omitted using it? Many thanks for you channel. I particularly liked the video you did on installing lights in the loft. Kind regards...
@willappleton
@willappleton Год назад
hey i have a double waterproof socket that has two sets of 3 wires 1 on each plug... i want to convert it to a single timer based outdoor socket.. it should be ok to double up the wires as you said?? thanks now
@jtmac5745
@jtmac5745 2 месяца назад
Top man👍
@TheDIYGuy1
@TheDIYGuy1 2 месяца назад
🤙
4 месяца назад
Awesome video! Thanks for sharing! Quick question: the socket has 2 earth entries, why did you use only one? Does it mean one gang will not be earthed? Thanks!
@grahamrousell691
@grahamrousell691 Год назад
Completely logical and efficient approach and excellent video. With your experience can you please clarify how the regs apply to this? I always understood all wiring in Kitchens, Bathrooms and outside had to be done by a NICEIC approved electrician and measurements taken of the new circuit. Are these reg requirements more relaxed now with the general installation of RCDs? Thank you
@TheDIYGuy1
@TheDIYGuy1 Год назад
🙏thanks
@montystelevision3238
@montystelevision3238 3 года назад
No peksy adverts in this video - subbed as a result.
@3000shifty
@3000shifty 11 месяцев назад
Thank you.
@TheDIYGuy1
@TheDIYGuy1 11 месяцев назад
You're welcome!
@misterjefferson6707
@misterjefferson6707 7 месяцев назад
Excellent video. I have no DIY knowledge at all. I have a single socket outside - is it the same process to change from single to double as your indoor single to double socket change? Thanks!
@chriswilkinson3260
@chriswilkinson3260 Год назад
Oh it has helped mate spot on I have a outside socket on my new house I've just bought would I be right in saying I can bounce of that like you have in your garage and then put two double in my shed or would that overload it it's a new build I've got so one socket is on the house outside already it's only to run a dryer some led lights and maybe a spare in there for charging my drill up ect
@TheDIYGuy1
@TheDIYGuy1 Год назад
You can spur off once on a ring circuit so it's best to check what circuit type you have first. The circuit in the video is a radial circuit.
@chriswilkinson3260
@chriswilkinson3260 Год назад
@@TheDIYGuy1 thanks I don't know so I'll pay someone in that case then I know it's safe
@rayc1503
@rayc1503 Год назад
Masterplug BG Outdoor Mains Socket Power Kit & RCD Protected Plug Weatherproof. (Google this). You can attach further sockets to this as long as the rcd plug socket is protecting all the cables.
@robertpeters8531
@robertpeters8531 2 года назад
Thanks
@TheDIYGuy1
@TheDIYGuy1 2 года назад
Your welcome
@rosivison6526
@rosivison6526 Год назад
Nice video and very easy to follow. Do you have a ring or radial circuit? I see you are taking the power off the socket that only has one set of wiring in it? Is this the end of the circuit or is it already a spur?
@TheDIYGuy1
@TheDIYGuy1 Год назад
Hi. This is a radial circuit. Thanks
@Danieltammadge
@Danieltammadge 2 месяца назад
In the uk don’t you need to get new outside sockets or wiring of that case signed off by a P certified installer. Or you void your house insurance and face fines etc?
@chrisuk1287
@chrisuk1287 11 месяцев назад
New subscriber so of course checking out your back catalogue, great content thanks, need to do this myself, it is always great to see a a video guiding you through it, yours is clear and concise so thank you :) Can I ask, we do have RCD protection at home, is there any good reason to still use an RCD protected outdoor box? Extra protection in some way? If there was an issue which would trip first the RCD in the outdoor socket or the house RCD? Like you there are lots of circuits on our setup at home protected by the 1 RCD so if the outdoor socket tripped first that of course would leave all the house circuits still live, any idea?
@VanyaYani
@VanyaYani 5 месяцев назад
If I understood the question correctly, he's not using a separate RCD for the outdoor box. He's using the same RCD for both outdoor and indoor sockets. There's not RCD inside the socket. The RCD is the thing in the consumer unit. The RCD protects a fault in the thing plugged into the socket, so yeah, it makes sense to protect the outdoor socket as well, especially considering those are heavy duty things that are usually plugged into it. You could install several RCDs to protect different groups of consumers so that you would isolate the issue quicker and still have half of the house working.
4 месяца назад
One other question: could you have used wago connectors on the "source" wiring instead of double wiring the socket?
@jigneshmistry2341
@jigneshmistry2341 Год назад
Legend
@TheDIYGuy1
@TheDIYGuy1 Год назад
👍
@KristopherPorter1986
@KristopherPorter1986 2 года назад
Are the wires between the originally installed socket loops more sturdy/capable than the wire you use for a spur?
@TheDIYGuy1
@TheDIYGuy1 2 года назад
Hi. The wire is exactly the same 2.5 t&e. Cheers
@samanthastewart8849
@samanthastewart8849 9 месяцев назад
Hi I have an outdoor plug but it's at the bottom of my garden in a shed and it's an old plug that's always been on as it was for our oil boiler but it has stopped working what do I do?
@williamhastings4491
@williamhastings4491 Год назад
First Class
@TheDIYGuy1
@TheDIYGuy1 Год назад
Cheers 😊
@Ramskill85
@Ramskill85 4 месяца назад
I’m thinking of doing this myself. I’m just wondering if this needs to be signed off by an electrician? Don’t really want the hassle when coming to sell the house in the future.
@sulemanyusufadam4315
@sulemanyusufadam4315 3 года назад
Great video! I’m assuming that’s a radial and that you didn’t spur off a spur? 🤔 Personally I’d probably run it through an FCU first but not necessary I suppose. Often people don’t use conduit but it’s important to protect the cable.
@TheDIYGuy1
@TheDIYGuy1 3 года назад
Hi, thanks. Yes this is a radial. Thanks for your input
@RajSidhux
@RajSidhux 2 года назад
Hi, great and easy to follow video. Question: I'd like to install one of these in my back garden. Can you tell me would you need an electrical cert. for this? When do you need cert.s?
@TheDIYGuy1
@TheDIYGuy1 2 года назад
Thanks. Technically yes, outside is an area where electrical work should be undertaken by a qualified electrician. But it depends if you want to follow the rules or undertake it yourself, the decision remains yours. This video is purely an instructional video.
@RajSidhux
@RajSidhux 2 года назад
@@TheDIYGuy1 I understand. I want to know if i do it myself, there are no laws against it right? And also, if i do it myself, could i then get a qualified electrician in to retro cert. them for me?
@rayc1503
@rayc1503 Год назад
@@RajSidhux It's notifiable under a minor works cert. The only way it wouldn't be is if you fitted an RCD protected plug. It would have to have no fixed point of wiring inside the house. Like in this video.
@andyneary6448
@andyneary6448 Год назад
Great video, thanks again. Is it safe to attach an outside plug and light to the corrugated metal sheeting I have around my shed? If it is safe to do so - Does the plug need to be fitted to a flat surface? If yes, then presumably I can attach it to a piece of ply and then screw the ply to the corrugated sheet.
@TheDIYGuy1
@TheDIYGuy1 Год назад
I'd go for a flat surface for sure 👍
@rayc1503
@rayc1503 Год назад
Ip rated 20mm Cable gland and some 2.5mm weatherproof arctic cable coming out the bottom through the wall in conduit and fit it to a 13 amp rcd plug.
@CS-rf6jq
@CS-rf6jq Год назад
I. could. do. this. Thanks for making these videos without sounding like an arrogant know it all (except at 5:08 lol ;) ) and keeping the videos gibberish free.
@nitinkoli5nk
@nitinkoli5nk 3 года назад
Hi the socket box is 13 A do we have to use a socket fuse spur with 13 A fuse or we wire directly as you have show in this video?
@bradreeve6233
@bradreeve6233 3 года назад
Just come straight out the socket either way doesn’t matter really
@nitinkoli5nk
@nitinkoli5nk 3 года назад
@@bradreeve6233 Thanks for info.
@Brynben1
@Brynben1 7 месяцев назад
Stop banging the tools and materials around 😂😂 Another well explained tutorial, thank you
@WJCTechyman
@WJCTechyman Год назад
I find it interesting your boxes don't require the non-metallic (Twin and Earth/Bare) to be clamped in place inside the box like we have in Canada. I also find it interesting that you put a sleeve over your grounding/earth conductor.
@acelectricalsecurity
@acelectricalsecurity Год назад
We stopped having bare earth's probably before the 60's
@ConradWilliams400m
@ConradWilliams400m Год назад
Nice and simple you don’t need a lot of tools . Hahahahahahaha😂 brill video
@TheDIYGuy1
@TheDIYGuy1 Год назад
Absolutely, thanks 👍
@TheMartyJD
@TheMartyJD Год назад
Was going to do something similar, but the only socket I could find inside was already a spur and therefore was looking for somewhere else to connect to. I see that you've done exactly that (assuming it is a ring rather than radial). Is there any issue of spurring off an existing spur?
@TheDIYGuy1
@TheDIYGuy1 Год назад
This is a radial circuit on the video. You can only spur off once on a ring.
@tabraham1992
@tabraham1992 Год назад
@@TheDIYGuy1 the radial you spurred off was the end of line, so all you’ve done is extend the radial
@rayc1503
@rayc1503 Год назад
If you can put a 13a fused connection unit before the existing spur then run a new cable to both it and the new point. Then the 2.5mm t&e cable itself is protected from overload. Better still buy an outdoor socket which has an rcd type plug. The fuse and rcd plug should trip incase of fault, thus protecting the existing cable.
@terex1983
@terex1983 3 года назад
Good DIY video, some nice detail with the protection of cables through walls for example but for anyone that may attempt to follow it: Check the inside face of the wall for services not just the outside with those detection devices, they will not penetrate a cavity wall. Also, electrical cables can/should be run directly vertically and/or horizontally in any direction from any accessories (switches and sockets etc). PROVE that the circuit is dead before working on it - don't just rely on the fact it says it's off at the Consumer unit as it may be mis-lablled or fed from a different circuit entirely. TEST your modification afterwards. Plug in testers are a minimum as you will not notice a disconnected earth(CPC) conductor. As this is an outside socket has a high potential for faults.
@clitherowkid
@clitherowkid 3 года назад
Is that a soured socket and did you use 1.5 or 2.5 T & E ? Great video, I’m going to install one myself.
@TheDIYGuy1
@TheDIYGuy1 3 года назад
Thanks. It is a spur from a radial circuit. 2.5t&e. See this video which may help to explain further ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-reOctcb_5dU.html
@harrymonk6909
@harrymonk6909 3 года назад
I'm looking to put up an outside light, I've run 1.5 into it and a plug on the other end then just plugged it into my outside socket, I'd rather it be run directly into a switch inside, can you do a video for that please?
@TheDIYGuy1
@TheDIYGuy1 3 года назад
Hi, i will see what i can do for you. thanks for reaching out
@johnpaulcameron2162
@johnpaulcameron2162 3 года назад
Brown in common blue in L1 and earth connector blocked behind light switch
@tomedwards4489
@tomedwards4489 Год назад
Whats the Ze,zs,r1+r2, polarity and insulation resistance.was it a ring main if so did you calculate your readings of the ring r1x1.66 for the 1.5 cpc expected end to end result? Or was it x2.5 because you had a 1mm cpc in that old twin? On the rcd did it test OK 1x 5x. Type Ac rcd in the fuse board is that going to be OK. Just in case it don't comply have we checked the bonding.just some of the cheeks a competent person should be doing.
@jonthecarpenter8093
@jonthecarpenter8093 Год назад
So you have spured off a spur? Is there a fused spur before your first original outlet?
@TheDIYGuy1
@TheDIYGuy1 Год назад
Nope, radial circuit.
@markwelsh9068
@markwelsh9068 Год назад
Here's my problem: Where I need to install the outside socket is on a wall which, on the other side, is a landing with no sockets. The nearest socket is in a bedroom and, to get there from the inside wall where the outside socket is placed on the other side, I'd have to run cabling up and down and around a whole bunch of walls or lift up carpets and flooring to run underneath. The alternative would be, I guess, to, somehow, run directly from the main switch/consumer unit which is located downstairs (but on the same wall as the outside socket) and then it's a matter of, somehow, running cable from the consumer unit (all switches are used however) but how to run the cable up those stairs, I have no idea. Any suggestions? Thanks.
@paulbowmer9507
@paulbowmer9507 6 месяцев назад
Move house?😊
@flashmg89
@flashmg89 5 месяцев назад
Come out of house where convenient into outdoor junction box and then run cable along outside wall in trunking and enter socket box via side knockout?
@apocreg11
@apocreg11 Год назад
So I have a ring circuit and I have taken a spur to a double outside plug off a single plug, then a SWA to a second single socket off that double socket. So 4 sockets in all off one spur. Given all 13 amp this should be ok?! Despite you normally saying only one spur off a ring circuit plug?
@TheDIYGuy1
@TheDIYGuy1 Год назад
Hi. Unfortunately this isn't advisable and I wouldnt feel comfortable with it. This is due to the load on the cable.
@deansharpe6527
@deansharpe6527 Год назад
I’m going to be doing this using 2.5 my flex, I know this is probably a daft question but should I be using a 13amp plug?
@TheDIYGuy1
@TheDIYGuy1 Год назад
👍
@elbowtoe84
@elbowtoe84 5 месяцев назад
@george9710
@george9710 Год назад
Nice video. IMO pex is a total overkill and you can easily seal the hole with silicone, mastic, etc. Since the electrics are attached to the wall, you will get no movement and mechanical degradation of the protective sleeve. That said it's a really nice touch and makes things very serviceable. One trick to save yourself a lot of potential problems, don't pre drill the box. Level it on the wall, and use some duct tape to hold it (temporarily). Drill though the box and into the wall. That way you know it's all lined up and you'll never have to deal with poor placement of plugs. In case this is not clear, you need to turn the hammer function off when you drill the plastic. ABS plastic is strong but you can still crack it. Also a masonry bit will technically rub the plastic until it sort of melts away rather than drill it but it absolutely works. Once you have a hole in the wall, depending on the plugs you use, you may even be able to insert them though the box into the wall ( with the screw slightly attached). Small size Rawplugs work like this but Fisher doesn't so you'll need to move the box out of the way for a bit.
@andrewappleyard796
@andrewappleyard796 Год назад
I oready have a outside light , could you use a terminal strip ( not use on the amp needed ) use a terminal strip inside a waterproof junction box to split the wire intoo 2 lights off the one wire Sorry might sound like a stupid question but I'd rather ask then find out the hard way , tia
@rayc1503
@rayc1503 Год назад
As long as the cable isn't overloaded. Let's say 1.0mm twin and earth on 2 400w flood lights off an existing 6A mini circuit breaker, it should be Ok. Better if it's fused from inside (3A for loads under 690 Watts)
@MrMedicalUK
@MrMedicalUK 2 года назад
Can I run conduit under the soil along my path down to my pool and fit this to a solid wooden fence post?
@MrMedicalUK
@MrMedicalUK 2 года назад
About 10 metres
@MrMedicalUK
@MrMedicalUK 2 года назад
Also where did you find 15mm solid Conduit? I can only find flexi at 15mm Wanted to run solid from the outside wall into the ground then flexi along the ground
@TheDIYGuy1
@TheDIYGuy1 2 года назад
Hi. I would advise using armoured cable for underground use.
@barry10ish
@barry10ish Год назад
Have you done a video on how to wire a shed ?
@TheDIYGuy1
@TheDIYGuy1 Год назад
Not as yet but maybe in the future 🙂
@rayyg2508
@rayyg2508 2 года назад
What size cable was used?
@TheDIYGuy1
@TheDIYGuy1 2 года назад
2.5mm twin and earth.
@kerryman9589
@kerryman9589 3 года назад
How much mastic do I need and were can I get it
@spencerwilton5831
@spencerwilton5831 3 года назад
Minimum ten gallons. Only available from a little stall in Bagdad market, turn left at the knock off Nike seller and if you pass the guy selling mosque shaped alarm clocks you have gone too far.
@hughwilliams5995
@hughwilliams5995 Год назад
I see below that this circuit has been tapped off a radial rather than a spur. Many people will be tapping from ring mains, and it's important that they don't do this off already existing spurs. Perhaps this should have been included, especially as it means that they'll be attaching 3 lots of connections into the back of the socket (two for the ring and one for the outside spur) which can be hard to do given the inflexibility of modern gauge wiring, and more likely to end with loose connections from having three wires in each terminal.
@TheDIYGuy1
@TheDIYGuy1 Год назад
A fair point that. This was my first RU-vid video. If I were to make it now(nearly 3 years later) I would have included that point
@abdulmaajid3030
@abdulmaajid3030 3 года назад
Because it’s ip66 if you drill the drain whole would it still be ip66
@entercybotron6154
@entercybotron6154 3 года назад
I've watch other video's and they say NO it won't be after you drill it out
@chaos.corner
@chaos.corner 8 месяцев назад
IP66 is waterproof. Unless you are mounting it to a submarine, you probably are better off avoiding condensation problems.
@badgerburns521
@badgerburns521 9 месяцев назад
really good instructional video but could you amend the description text with a list of the tools and equipment needed please?
@TheDIYGuy1
@TheDIYGuy1 9 месяцев назад
Thanks
@stuartcraigon2003
@stuartcraigon2003 9 месяцев назад
DOH! As soon as you drill that drain hole its not ip66 rated anymore. Youll see on the instructions or the writing on the back box that it clearly says that.
@tj9382
@tj9382 2 месяца назад
But he threw them away 😂😂😂
@goldslcc02
@goldslcc02 2 месяца назад
Actually in the UK it is still ip66 rated if the designated drain hole in the bottom most part of the box is no bigger than 4mm, so it's absolutely fine it's used because of the high humidity levels in the uk, the box protects against water ingress but not air and we all know when air reaches 100% humidity it condenses in the box and forms dew.
@singe81
@singe81 10 дней назад
Yep. A video on eFIXX channel shows the drain hole being drilled.
@thomasparsons4999
@thomasparsons4999 3 года назад
I’ve got brown,blue and back wires is that normal ?
@kevinwhite2380
@kevinwhite2380 3 года назад
Not normal! Get a Qualified Electrician if you don't know what what cores do what? #Blue_Wizzard
@malachydixon9187
@malachydixon9187 Год назад
Brown and red is live black and blue is neutral and earth is always yellow and green
@lllCostalll
@lllCostalll 7 месяцев назад
what size electrical cable
@TheDIYGuy1
@TheDIYGuy1 7 месяцев назад
2.5mm t&e
@phill3144
@phill3144 9 месяцев назад
Is this not a spur off a spur, and no isolation point after the internal wiring.
@TheDIYGuy1
@TheDIYGuy1 9 месяцев назад
No, it’s a radial circuit
@hectorheath9742
@hectorheath9742 3 года назад
Isn't that running a spur from a spur?
@TheDIYGuy1
@TheDIYGuy1 3 года назад
Radial circuit not ring main so it's within regulations
@Mike_5
@Mike_5 3 года назад
Virgin Media teach you to drill from the inside and push all your weight on the drill so it comes out the other side like DumDum bullet hole and busts all the brick face out ...
@leebrailsford251
@leebrailsford251 7 месяцев назад
Your newest videos are ssssoooooo much better than this. Thank god.
@TheDIYGuy1
@TheDIYGuy1 7 месяцев назад
Hah your right!
@charliehead94
@charliehead94 4 месяца назад
Surprised you did not run the power into a fused spur internally then to run it through the wall to the socket.
@adamdean4322
@adamdean4322 Год назад
Should never be done by Diyer though. Unless you can test the circuit how do you know it’s safe.
@TheDIYGuy1
@TheDIYGuy1 Год назад
It’s very simple for a DIY’er to make safe. Thanks
@andyb7507
@andyb7507 Год назад
Basically you need the contents of B&Q to do this job
@LeapOfFaith121
@LeapOfFaith121 2 года назад
Where abouts are you based?
@TheDIYGuy1
@TheDIYGuy1 2 года назад
Norwich, UK
@LeapOfFaith121
@LeapOfFaith121 2 года назад
@@TheDIYGuy1 I thought I recognised that accent. Great videos. 👍
@TheDIYGuy1
@TheDIYGuy1 2 года назад
@@LeapOfFaith121 haha! Thanks
Далее
How to Install the Easiest Outdoor Socket
15:22
Просмотров 750 тыс.
How to Add a Socket to a Wall - Easy Step By Step Guide
18:55
What turned out better to repeat? #tiktok
00:16
Просмотров 3,4 млн
Cabeças erguidas, galera! 🙌 Vamos pegá-la!
00:10
5 Mistakes Everyone Makes Changing Sockets ❌
11:44
Просмотров 480 тыс.
Installing an outdoor socket
29:05
Просмотров 32 тыс.
Installing power to a garage building! Fusebox F2004M
19:19
What turned out better to repeat? #tiktok
00:16
Просмотров 3,4 млн