Тёмный

How to Test Kohler Charging System 

Sartin Garage
Подписаться 6 тыс.
Просмотров 143 тыс.
50% 1

Check out Sartin Garage Storefront
BEST DEALS
www.amazon.com/shop/sartingarage
See Parts List Below
Check out Merch Store:
sartin-small-engine-garage.cr...
Consider becoming a Patreon
/ sartingarage
How to Test Kohler Charging System includes Testing Stator and Voltage Regulator.
For All Your Kohler Engine Part Needs
Consider Joining FB Group
groups/11043...
MULTIMETERS
Cheap
amzn.to/4bgn85O
Good
amzn.to/3wyCNOJ
Best
amzn.to/3QV9f3s
Rechargeable Digital
amzn.to/3KibDz7
VOLTAGE REGULATORS
Verify Part Number before Ordering
Aftermarket
amzn.to/3JVg1n8
OEM
amzn.to/44FzAJU

Хобби

Опубликовано:

 

7 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 340   
@algentry4382
@algentry4382 4 года назад
Well done. Good camera work. Easy to see and easy to hear and understand
@blackbirdbill
@blackbirdbill 4 года назад
your videos helped us diagnose my son's Troy-Bilt. I've been working on engines for 50 years and I was stumped. It is now running well.
@ronsmith9228
@ronsmith9228 4 года назад
Thank you sir for your great charging system videos, I watched both. They helped me track down a charging wire that was hooked up wrong for an 1999 xmark zero turn. I replaced the engine with a new carbureted 25hp Kohler, I didn’t want a new machine and try to stay away from ecm controlled machines. They had the charging wire from the factory/distributor running to the starter solenoid ? So I put an end on the wire and put it in the harness plug to the switch and now charging good! You speak slowly so I can understand and I appreciate you helping us all, thanks again!! Ron Smith
@user-sk8np3kw5z
@user-sk8np3kw5z Год назад
Your video just helped me fix my e mark with Kohler engine. Wound up being dirty ground on voltage regulator. Awesome video!
@Bill-nd2qd
@Bill-nd2qd 2 года назад
Great video. Also a good idea to test all the relays. My older Craftsman lawn tractor wasn't keeping the battery charged so I followed your procedure. I had voltage at the stator but not the rectifier. Was going to order a new rectifier but figured while I'm at it I might as well check the relays too. I found one bad one and replaced it, tested the rectifier again and got 14 volts. Bad relay was the one with a red wire going into it. I didn't trace all the wiring, just happy the battery is charging again.
@MrRealtorJim
@MrRealtorJim 4 года назад
Great demonstration. I just checked the charging system on my John Deere with the Kohler Command 23 engine. The engine would not turn over fast enough when attempting to start it. I did what you said and found out the stater and the voltage regulator both gave the correct outputs. In conclusion, the battery was not charging to the capacity it needed. So, I replaced the battery. A few years later, I replaced the battery when it turned out the problem was the voltage regulator. I am sure many people blame the battery like I did.
@PapaHepcat
@PapaHepcat 2 года назад
This totally helped me, thank you. My Kohler V-Twin 26hp was weak charging and couldn’t keep up after I added an electric fuel pump. I tested like you demonstrated and found the stator was good. I just head to clean connections like you mentioned, and now it’s back to 14v. Whew. Glad I don’t have to replace the stator.
@randyhobbs2699
@randyhobbs2699 4 года назад
He laid out very easy steps to follow. One of the stater wires slipped out of the plastic connector housing and was not making a good connection with the voltage regulator Did the test (s) like he showed everything tested good. Got the white wire locked back into the plastic connector housing plugged back onto the regulator. Putting out 14.5 volts! Thanks for the info probably saved me $100 + service bill at the shop !!
@customcutter100
@customcutter100 Год назад
Thanks for the video. Been charging my battery for 2 years once a month. Checked for voltage back to the switch and nothing. Verified the charging system was working. Checked the purple wire and it was broken off at the second plug. No voltage due to corrosion, so I stripped the wire and checked again. It was hot regardless of the key position (I decided to cut the wire off and insulate it, didn't like a hot lead all the time). I found another purple lead with a female blade connect that was only hot with the key on and cut the purple lead at the plug. Crimped on a male blade and heat shrunk some insulation, and pressed it into the female blade connect, bypassing the second plug altogether. No more dragging out the battery charger and 100' cord every 3-4 weeks to cut the grass.
@securityfamily
@securityfamily 10 месяцев назад
My battery went dead today, and your video gave me the fix to ground the unit. Working now!
@highpointhillfarm9452
@highpointhillfarm9452 3 года назад
Good video, helped fix my scag that wasn’t charging. Sure enough it was a bad ground at the reg.
@wcb2251jr
@wcb2251jr 3 года назад
You did a great job explaining this. A neighbor gave me a John Deere L130 and it is a Kohler CV23S. It will not stay charge. I am definitely going to try this.
@sartingarage8045
@sartingarage8045 3 года назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-zRwkKNGkymU.html Watch this Video also. Although it is a Kawasaki Engine. Kohler works the same way. Alot of good info in this video
@williamblankenship6571
@williamblankenship6571 2 года назад
Thank you. Helped me diagnose and fix the charging problem on my kolher 20hp rider. 👍👍👍
@rickparran81
@rickparran81 3 года назад
Great video. Step by step,, Boom!!!! Thank you sir.
@vicfirman6585
@vicfirman6585 2 года назад
My son's Kohler 25hp wouldn't charge. I checked the stator output and was a whopping 44v. It was in fact a bad ground on the voltage regulator, easy fix. Thanks a LOT for the video.
@billmazur9002
@billmazur9002 Год назад
Thank you. Great walk through. Helped me save a lot of time and money!
@slick88able
@slick88able 4 года назад
Great video. You were straight to the point and explained the process so the average guy like me who isn’t a Master Tech could follow along. My Kohler C18 regular has a hole melted in in behind one of the stator wires. Thanks for the video!
@mackendw
@mackendw 3 года назад
thx for your video. very helpful and timely. my voltage regulator just crapped the bed...
@lenorabillings2141
@lenorabillings2141 4 года назад
Thank you for this video! I stopped at 3:36, checked the ground wire and Viola! fixed. I've been dealing with this glitch for over a year. Thank you so much!
@utuberdave
@utuberdave 3 года назад
Very clear! Thank you!
@sahmadi1000
@sahmadi1000 Год назад
There is no better explanation that what you have done. THANKS
@sartingarage8045
@sartingarage8045 Год назад
I have another Video that will help you that is more comprehensive. The only difference is this Video is on a Kawasaki Engine. The charging works the same way. The only difference is the output on the kohler Voltage Regulator is the center Pin. On the Kawasaki it's Pin to Right. Left 2 are AC. ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-zRwkKNGkymU.html
@josephmanno3114
@josephmanno3114 2 года назад
Thank you sir. Exactly what I needed
@davidtully8130
@davidtully8130 2 года назад
very good video so informative and easy to understand --good job
@775pop
@775pop 2 года назад
Thanks very helpful very helpful and imagine a little ground wire to mess up your whole charging system thanks again
@robertthehair658
@robertthehair658 Год назад
YOU JUST SAVED ME HOURS, DUDE....!!!!
@Oldslipper
@Oldslipper 10 месяцев назад
Great video, easy to understand. Thanks
@775pop
@775pop 2 года назад
Thanks for posting that video it was very helpful for me and my Kohler engine certainly make a difference a Ground wire to mess up your whole charging system thanks once again thanks ✅✅✅
@MikeGauley
@MikeGauley 3 года назад
Thanks, great video!
@whitebear9699
@whitebear9699 3 года назад
Thanks, very clear! Understand now. Thanks
@chicoreyes5937
@chicoreyes5937 2 года назад
thank you for your help the video was very good hopefully ill get my L. mower going
@petrturcovsky7035
@petrturcovsky7035 2 года назад
Thank you very much, will check my engine soon :).
@pth6060
@pth6060 3 года назад
Very Helpful, thanks
@jasondavis1453
@jasondavis1453 Месяц назад
great vid ps thanks for detailing the settings on the multi meter
@robertyearian227
@robertyearian227 2 года назад
Very good explanation
@Quintavious-Gooch
@Quintavious-Gooch Год назад
This solved my charging problem. I had accidentally left the grounding strap off whilst replacing the two ignition modules. Unfortunately, I found this video after I had ordered a new regulator-rectifier module and waited for it to come in.
@jerrykast7713
@jerrykast7713 2 года назад
Thank you very much. This was very helpful.
@jdprice3043
@jdprice3043 Год назад
THANK YOU FOR YOUR HELP
@annmoulton9348
@annmoulton9348 2 года назад
Thanks. This really helped!
@opinion4246
@opinion4246 Год назад
Thanks that was a big help.👍
@ronniewetherington509
@ronniewetherington509 Год назад
Thanks for sharing.
@lawsonstallings1955
@lawsonstallings1955 Год назад
Well done!
@ericuncapher9922
@ericuncapher9922 3 года назад
Thanks for the the help
@Stomachbuzz
@Stomachbuzz 3 года назад
Thank you very much!
@mauricehumphrey6074
@mauricehumphrey6074 4 года назад
great job
@elwoodrawlings1163
@elwoodrawlings1163 10 месяцев назад
Excellent video troubleshooting a Kohler. My issue was exactly as you described. The yellow right terminal to the block ground, the screw face and inside was corroded with rust. Also, the left side yellow terminal was sparking intermittently . Looks like a poor engineer design, the left terminal going the the rectifier is threaded through and secured by the plastic shroud only, and stripped out if you tighten it. Kohler needs a more robust mount than a screw through plastic fastening method. Thanks again, you earned a new subscriber here.
@michaeldobson1133
@michaeldobson1133 2 месяца назад
Very informative
@robertyearian227
@robertyearian227 2 года назад
Good job 👏
@michaelha7
@michaelha7 2 года назад
I was hoping you might go one more step. I found the video very good , My stator was putting out over 45, The rectifier was putting out 14-15 yet when I check the battery terminal, it was 12.7 which isn't enough to keep my battery charged. I welcome your thoughts as well as others that might have some insight. I checked the bottom fuse on my Exmark 60 Turf Tracer 23hp Kohler . Many thanks
@sartingarage8045
@sartingarage8045 2 года назад
That wire off voltage regulator goes to key Switch A1 or A2 usually Test key switch from B terminal to A1 or A2 terminal. You can disconnect battery and do a continuity test from wire on voltage regulator to key switch connector to find which terminal it is on key switch.
@michaelha7
@michaelha7 2 года назад
@@sartingarage8045 UPDATE: I could not sleep, the little voice inside my head was talking to me and said, Silly Boy , Check the fuses, Everything was reading perfect except at the battery. I had to physically take a pair of pliers and pull the top fuse from the holder (because it had fused to the plastic) It was fried. Put in another fuse and it was reading over 14 at the battery... Very happy and just wanted to share in the hopes it helps someone Else. WE all can learn from each other. Many Thanks
@f7730
@f7730 11 месяцев назад
Thank you
@armandolopez5826
@armandolopez5826 3 года назад
Good vide my amigo
@aslmx1918
@aslmx1918 3 года назад
Thank you sir. Was able to fix mine. Went through 2 batteries in a year. Now it’s charging properly. Mine must have been built at quitting time on Friday. Didn’t have a ground jumper at all.
@flintknappingtools
@flintknappingtools 3 года назад
helpful! thx
@samkaplitz9036
@samkaplitz9036 2 года назад
Fantastic!
@justinh6170
@justinh6170 Месяц назад
I have a kolher 18 craftsman riding mower with a electric powered hydraulic front bucket loader that’s not charging I hope mines simple as a bad ground going to mess with it today thank you didn’t know witch wires went to the stator
@christophermaurer1271
@christophermaurer1271 3 года назад
Thanks, that was a great help . When checking the purple wire part of the metal tab that makes a connection to the voltage regulator has fallen off. This may be the problem that has plagued me for months . Is that whole wire assembly to the voltage regulator easily replaced ? And if it's not too personal , which part of the U.S is your accent from. Cheers from Australia.
@r.curran5870
@r.curran5870 2 года назад
Thank you...
@glenclark3733
@glenclark3733 4 месяца назад
Thanks
@Corey-dy2cq
@Corey-dy2cq 29 дней назад
Thanks for the video. Getting ready to apply this method on my Kohler Command 20. It's 20 years old and just had it serviced. The guy installed a new seal as it was leaking oil so I think he would have noticed any stator issues? Probably some rusty connections.
@Corey-dy2cq
@Corey-dy2cq 29 дней назад
It does the same thing. It seems like it almost dies when I engage the PTO but it never has died from that. It's weird because I can run it all day and once I shut it down it doesen't want to start until it's cooled way down. At least before the guy worked on it. Now I have to jump it every time I shut it down.
@sartingarage8045
@sartingarage8045 29 дней назад
@Corey-dy2cq He may not have checked the charging system if it was took in for just an Oil leak. But even if he did check it, Anything can go wrong after everything checks OK. As far as it almost dies when engaging PTO sound like it maybe running on one Cylinder if it's a twin Cylinder , Or Govenor is not set Correctly is where I would start.
@34tab
@34tab 2 года назад
Thank you sir
@v8hackshack667
@v8hackshack667 2 года назад
I have a nice running k181 a on a go cart I’m finishing up. Quick question with a generic eBay rectifier does it matter witch way I connect the two white engine wires? As long as the middle post off the rectifier goes to the correct post on the key switch right? Also an amp meter can be spliced directly into the wire that powers the key switch without problem?
@sartingarage8045
@sartingarage8045 2 года назад
Pretty sure it doesn't matter
@danielcastillo-jarillo1261
@danielcastillo-jarillo1261 4 года назад
Alguna herramienta que recomiende para la recharge de bateria. Muy buen video e informativo manita arriva.
@sartingarage8045
@sartingarage8045 4 года назад
Need a battery charger. Maximum of 10 amperage. Smaller is better for battery life
@charleschampion5121
@charleschampion5121 4 года назад
Thank you for the kohler video it helped me a lot. Turns out my kohler is putting out 14.5 volts but its not getting to the battery can i just run that purple wire straight to the battery? Instead of messing with the switch?
@sartingarage8045
@sartingarage8045 4 года назад
No you can not It will constantly drain your battery. Most of the time the key switch is the problem. But need to check connections from that wire to key switch From the key switch it goes to starter solenoid If you follow the battery positive cable down to Solenoid , there will be a small wire attached to that same post on the solenoid. That goes to the key switch Check all those connections and test key switch I have a video on testing key switch
@sartingarage8045
@sartingarage8045 4 года назад
So if you start from voltage regulator DC output wire That goes to a connector if you follow the wire. Then it goes to key switch terminal A1 Inside key switch it connects A1 to B terminal. B terminal wire comes from the Battery post side of sokenoid The wire I was telling you about in previous reply
@curtaberle1783
@curtaberle1783 4 года назад
Thanks for this video! I have a Scott's by JD, 2348 Kohler 23hp engine very similar to your video. Any idea why the battery would not charge (batter light comes on) when the mower (PTO) is engaged?
@sartingarage8045
@sartingarage8045 4 года назад
Does it charge when PTO is disengaged And Not charge when PTO is engaged. If so your gonna have to chase the charging wiring to find where the connection is lost. If its not charging only while engaged Most likely PTO switch is losing the connection for charging
@curtaberle1783
@curtaberle1783 4 года назад
Sartin Garage it was not charging until I followed your trouble shooting video. Now it charges only when PTO is NOT engaged. The battery light comes on when PTO is engaged. Thanks
@lestersegelhorst2776
@lestersegelhorst2776 2 месяца назад
My Cub Cadet just up and died this evening while it was in low-idle. I thought it ran out of gas but it ran out of lightning. I just put a new bat. In last summer. It was flat! Apparently I have a charging system problem. Hope it's just a regulator. Thanks for the video
@lestersegelhorst2776
@lestersegelhorst2776 2 месяца назад
An update... found a blown 20amp fuse. (Engine was idling with blades disengaged.) May have been a low voltage situ. (High amp) or possibly a faulty regular or stator.
@michaelkyle4097
@michaelkyle4097 3 года назад
Is it possible to put the connecter that plugs into the voltage regulator on backwards? Mine was just unplugged and it’s hard to tell which way it was plugged in originally. And it well plug in ether way
@sartingarage8045
@sartingarage8045 3 года назад
For most kohler voltage regulators it doesn't matter. But to put it on like it was from factory. There should be a small tab on one side of connector. The other side of connector just flat. Flat side towards the engine
@bryans8193
@bryans8193 2 года назад
Great videos and thank you for them! I have a question about my John Deere Sabre 1948hv. When I turn the tractor on my battery light has been coming on. What are the scenarios that make that light come on?
@sartingarage8045
@sartingarage8045 2 года назад
Multiple things can cause this light to come on. Battery Ground to frame Voltage Regulator Ground connection Key Switch Defective which would depend on how the battery light is wired up Weak Stator There's a few to check
@bryans8193
@bryans8193 2 года назад
Thank you so much for the info and fast reply!
@rickybobby9223
@rickybobby9223 3 года назад
You just saved me from buying a stator that wasn’t needed! Thank you for saving me time and money. It turns out that my connection to the regulator was loose. Thanks again!
@aquariuswithfire
@aquariuswithfire 2 года назад
Great video. One question though - couldn't you start by checking the regulator dc output first. Can't we assume the stator is good if the volts out are good?
@sartingarage8045
@sartingarage8045 2 года назад
Yes you can If you have charging voltage there and not at the battery. Stator and Regulator are working. The problem then would be wiring or faulty key switch
@waynemurphy7394
@waynemurphy7394 4 года назад
The mower your working on in another video looks like my Husqvarna Z246. I have been having trouble with the safety switches . Could you do a video on testing all the switches ? Thank you, Wayne.
@sartingarage8045
@sartingarage8045 4 года назад
The mower I think your talking about is a Husqvarna MZ5424. Its a 24 hp Kawasaki with a 54" Deck
@psjr57
@psjr57 Год назад
Hi I have a Koehler 7000 that keeps popping the fuse as soon as I turn on the key. I have traced it down to the charging system. I have removed the rectifier thinking it was the problem, installed a new one and I get the same results, popes fuse. I also found out that I can turn on the mower and cut grass without the rectifier. I turned i5 on and tested the stator and it is giving me 34 or so AC. I am thinking it is the blue wire between the two white ones. What long term harm will I have if I run it without a rectifier and just place a charge every time I finish mowing.
@sartingarage8045
@sartingarage8045 Год назад
There are many things that can cause that. Any wiring short, maybe defective key switch.
@bud-in-pa589
@bud-in-pa589 Год назад
Will you damage the diodes in the regulator if you hook up a battery charger to the battery without removing the battery leads?
@sartingarage8045
@sartingarage8045 Год назад
I usually remove battery to charge it just to prevent other issues. But if everything is working correctly and key Switch is off. Even though battery is connected in Equipment, It is not connected to anything that is drawing current from battery. Would be hard to short out components.
@inspectorron403
@inspectorron403 4 года назад
Hello!! My mower only runs as long as I have my jumper cables connected from my car, so when I check the output from the mowers regulator am I just reading my cars regulator and not the lawn mower? As soon as I disconnect the jumper cables the mower dies.. all the connections are clean and the voltage regulator ground is good. Thanks!!
@sartingarage8045
@sartingarage8045 4 года назад
Let me get this right Your Battery is Dead and mower wont turn over. So your connecting jumper cables from your car to the mowers battery and then mower will start, but when you disconnect cables from car. Mower engine shuts off immediately. If this is the case First thing you need to do is charge the battery that is in the mower, If it will charge, If not buy a new battery. After you get a good fully charged battery in mower. Start the mower and check charging system to battery.
@sartingarage8045
@sartingarage8045 4 года назад
If your car is running Yes you will show charging voltages from your cars charging system around 14 volts DC
@boatbuilder1954
@boatbuilder1954 4 месяца назад
This was a great video, I don’t have a connector with 3 wires on my voltage regulator, I have the 2 wires and I did what you said and put them on the outside terminals on the regulator however there isn’t a purple wire on the center terminal of the connector but on the other side of the motor there is a purple wire along with a green wire. Do you think the person I got the motor from cut the wire off on the regulator side or does the purple wire connect somewhere else inside the shroud? Your videos are so good thank you for posting them!😊
@teamcummins
@teamcummins 2 года назад
I have a 26.5hp Kohler horizontal engine. It quit charging. Cleaned up all connectors and put a new regulator on. I'm getting 43vac to the regulator but only 1vdc coming out. Any ideas. New battery. Even ran a separate jumper ground from battery to regulator housing and no change. Thank you
@sartingarage8045
@sartingarage8045 2 года назад
Most Regulators have to have battery voltage to the output that your only getting 1vdc out of. This voltage comes from key Switch B terminal on key switch comes from Starter Solenoid, small wire with fuse in it Connects to A1 or A2 terminal thru key switch A1 or A2 go to Voltage Regulator Watch this video it is a Kawasaki But everything works the same Just wires on Regulator are on different There are some good tips and tricks in this video ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-zRwkKNGkymU.html I also have key switch test video link below ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-fAWMFy9L9iI.html
@archrobertson1255
@archrobertson1255 3 года назад
i have a courage 19, stater and dc volts are correct. should the engine once running, continue running with battery disconnected? if not what would be suspect?
@sartingarage8045
@sartingarage8045 3 года назад
I guess I'm not understanding what your saying. But why do you want to run your engine with battery disconnected.
@alaricthedestroyer3491
@alaricthedestroyer3491 Год назад
@Sartin Garage I've got Kawa fh680v with 31 acv coming out of the stator, 14.6 dcv coming out of the regulator, and battery charging voltage showing 14.6 at full throttle. The excessive voltage isn't blowing fuses but is boiling a new battery in 3-4 days. Not sure why this is happening? Please help. Thanks!
@sartingarage8045
@sartingarage8045 Год назад
14.6 volts is Normal Charging Voltage When you say boiling a battery are you meaning battery boils over or are you just meaning battery goes dead. If the battery goes dead over a few days Sounds like you have a draw on battery while mower is not in use. I have a video on testing for this Link below ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-7f2dR0rT1fw.html
@Jeremy-qq2ip
@Jeremy-qq2ip 3 года назад
Nice walk through on the Kohnler charging system. I have a similar setup, but with a Tecumseh twin 25 hp w/elec. PTO that uses a 2 terminal voltage regulator instead of the 3 terminal your Kohler has. I've been nursing along a low/no charge battery for the summer, keeping a 3A charger/maintainer on it between mows, just getting around to taking a look today. Figured I'd share. I initially suspected the alternator winding (stator), but confirmed it's putting out just under 30v AC in to the regulator. When checking the B+ side of the regulator, it's only showing batt voltage at WOT. Two questions; 1) is there a bench test I can do/measure the voltage regulator before condemning it bad, even thought I'm pretty confident it's the root cause? It shows open on continuity and about 15 ohms resistance, but the longer I wait,t the lower the resistance creeps. I thought it should have a reading much higher, but not really certain? 2) the voltage regulator I need (1A183-164) is NLA on all the sites I've checked so far, any ideas where to find an old part that's been discontinued like this? Don't know if I want to trust a used one. Thanks!
@sartingarage8045
@sartingarage8045 3 года назад
You have good AC You have battery voltage to regulator But no output from regulator higher than battery voltage. Make sure base of regulator has a good ground. Base has to be grounded or will not charge. If you have good ground to base Replace regulator
@sartingarage8045
@sartingarage8045 3 года назад
Let me see if I can locate voltage regulator
@sartingarage8045
@sartingarage8045 3 года назад
I'm pretty sure this part # will work. Tecumseh Part # 611184 16 amp 2 pin regulator
@Jeremy-qq2ip
@Jeremy-qq2ip 3 года назад
@@sartingarage8045 Yep, that's the one I ordered the other day. I found it by looking in an old Tecumseh OEM Parts Guide, using the TVT691 engine. It's virtually the same as my VTX691. I also wanted to let you know that I confirmed continuity between the rectifier stack up to my engine and through the mounting hardware. I'll be glad to not have to keep hooking up that charger every time. Thanks again for your feedback!
@d.higginsconstruction8001
@d.higginsconstruction8001 4 года назад
Thank you for your video this is my beginning stages of trying to fix my Kohler CV 22 hp engine. When I tested the two white wires my engine would not stay running to complete the test so I just held the key on and it looks like on my meter I got around 45 to 50 V. Would you happen to know why the engine would not stay running with the connector disconnected? Then I proceeded to check the sea vault on the purple center wire on the connector to ground and did not get any voltage there at all so would that mean it is the stater I am to replace which is under the shroud?
@sartingarage8045
@sartingarage8045 4 года назад
You do not have to disconnect. Leave it connected Touch your probes to terminals
@d.higginsconstruction8001
@d.higginsconstruction8001 4 года назад
Sartin Garage OK Sartin I just tested it with the refractor attached and on my DC voltage on the center terminal I did get the 12 V however when I tested the AC two white terminals I only got 22.8 V so would that mean my stater is bad
@sartingarage8045
@sartingarage8045 4 года назад
I would think 22.8 volts would be enough Its a bit low, but I think its ok Engine off but Key on Should be battery voltage to purple center wire. If the voltage is Ok on purple wire Make sure base of voltage regulator is grounded. Should be a small wire connected to the voltage regulator going to shroud that grounds regulator. One lead on voltage regulator base Other lead to engine block or Negative ground. Dont use the bolt to ground to that is connected from the voltage regulator to engine shroud. As this will give you a false reading of ground due to its actually checking the wire.. If all ground is good and have battery voltage to purple wire Replace Voltage Regulator
@Mike-su8si
@Mike-su8si Месяц назад
I know theres a problem with mine cause i took each drained battery off my zero turn mower and used them on my other mowers and charged it a little then started it up and let it run on my Briggs engines and their staying charged on those. but gets drained on the Kohlers i figured its probably the rectifier not sending juice back to the battery while its running is why the batteries dead each time after using the mower the person i bought that from didn't even have the valve covers screwed down all the way and had to low of a amperage fuse put in had a safety button wire plugged in that kept blowing the fuse had some other wires taped up i took all those out that didn't need to be their I've been needing to check its rectifier but am working on a bunch of other different mowers
@mohmedhosny6094
@mohmedhosny6094 2 года назад
Very good video My issue in Kohler kt735 Stator reading 30at3600rpm Regulator reading 1v I changed stator become reading 40ac volt And change regulator become reading 8.65Dc volt
@sartingarage8045
@sartingarage8045 2 года назад
Kohler engines are bad to lose ground to base of voltage regulator. Make sure base of regulator is grounded Usually small black wire which connects to bolt on regulator and goes to bolt on engine shroud. Loses its ground at bolt on engine shroud. Also with key on make sure battery voltage is at regulator wire that you have 8 volts on. If there is no battery voltage problem is in key switch or bad connection.
@ELTOROLOCOSHOWHOUSTONTX
@ELTOROLOCOSHOWHOUSTONTX 4 года назад
I did everything you say on one of your videos about charging problems I even change the stator, en I'm Still getting 14v ac switch is working fine what else can be?? 60" ex mark z
@sartingarage8045
@sartingarage8045 4 года назад
14 vac is not enough What did the magnets look like inside flywheel. If there is a magnet missing or magnet that has came loose and has moved Stator will not output correctly. Magnets should be equally spaced apart and the magets are push pull push pull Meaning like first magnent is pull which would be like a regular magnet. The second magnet will push away Does the mower have electric Pto to engage blades or a lever to engage blades
@ELTOROLOCOSHOWHOUSTONTX
@ELTOROLOCOSHOWHOUSTONTX 4 года назад
@@sartingarage8045 yes then machine have electric switch to engage the Blades I never change that part get. On the magnets are in place they are all looking nice and clean, when I first see your video I did everything you show in your video and I was getting 16 volts ac and maybe 2v DC now with the new stator I am getting only 14.5 volts ac🤣🤣
@sartingarage8045
@sartingarage8045 4 года назад
Make sure when you check Stator Voltage you have the throttle at full throttle. Stator will show lower voltage at lower engine RPM's. May need to check RPM's with a Tachometer. I dont know what engine you have, but RPM's should be around 3400. Need to check spec on your engine for specific rpm.
@ELTOROLOCOSHOWHOUSTONTX
@ELTOROLOCOSHOWHOUSTONTX 4 года назад
@@sartingarage8045 one or two magnets were broken in one corner not very much you think this is the problem??
@sartingarage8045
@sartingarage8045 4 года назад
It is very possible Ive seen two magnets missing and stator would not output correctly
@bgood267
@bgood267 2 года назад
yep tks...
@jamesallan11
@jamesallan11 3 года назад
I'm getting 30.6 from sator and 12.4 from voltage regulator. Does that mean voltage regulator is weak or bad? Mower shows low voltage 11.7 when mowing .
@sartingarage8045
@sartingarage8045 3 года назад
Make sure base of regulator has a good ground. In this video it shows you how to check this. I also have another video on checking ground connections. If ground to regulator is good Replace voltage regulator
@girlintheblueridge6529
@girlintheblueridge6529 Год назад
Hi, thanks for your video... I'm getting 30V AC from stator but nothing from regulator...with engine off, using a multimetter i probed the center pin and neg post on battery and had no DC voltage... I was told there should be 12V when doing that. So do I have an open circuit on the positive side?.. what is my next step? Thank you.
@sartingarage8045
@sartingarage8045 Год назад
There should be voltage to that center Pin with key Switch in ON position. If there is NO Voltage with key on, Then yes you have a open short, bad key Switch. I have another Video that is on a Kawasaki engine and is more comprehensive. The only difference is your output is in the center on voltage regulator. Kawasaki Output pin is on one side. But watch this Video and it will help you Link below ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-zRwkKNGkymU.html
@girlintheblueridge6529
@girlintheblueridge6529 Год назад
Thanks so much.... I was missing that the key needed to be on. Thanks for the link.
@girlintheblueridge6529
@girlintheblueridge6529 Год назад
I turned key on and still had no voltage so I followed the wire to the plug and the wire had broken off the plug connector! So I reconnected the wire. I have 12V now and will be able to test regulator soon, but hat was more than likely the problem and my battery no charge issue should be fixed. Really appreciate your generous help!
@kenivey4856
@kenivey4856 4 года назад
I have a 27 hp Kohler and I checked the regulator and have 42 volts ac and then I checked the B terminal and I have 0 volts. I made sure that the regulator was grounded and checked the B terminal with one lead on it and the other lead on the battery ground and the motor and don’t have any voltage at all. This is a new regulator.
@sartingarage8045
@sartingarage8045 4 года назад
Disconnect connector to voltage regulator. Turn key to on position Check voltage to center wire in voltage regulator connector. If still No Voltage there. The problem is bad connection or Key Switch. There has to be battery voltage to this wire or voltage regulator will not work. Watch my video on Kawasaki charging System. There are some good tips in that video. Charging system works the same way Just connections are slightly different It will help you
@morrisedmonds7425
@morrisedmonds7425 20 дней назад
Very informative. I have 45vac at the two whites with the connector unpluged from the regulator, but only 9.5vdc at the purple when connected to the regulator. Both checks with Kohler running wide open. What's my problem or next check to be made. Thanks
@sartingarage8045
@sartingarage8045 19 дней назад
Check base of regulator to make sure it is grounded. One lead on base of regulator, other lead on Ground to engine block or battery Negative. Kohlers have a jumper ground wire from base on regulator to engine Shroud and alot of times they lose connection. If base of regulator is not grounded remove and clean this wire where it connects. Also check Purple wire for battery Voltage with Key in ON position. There has to be battery voltage going to Regulator on purple wire for regulator to work correctly.
@morrisedmonds7425
@morrisedmonds7425 19 дней назад
@@sartingarage8045 Thanks .... I'll check it tomorrow!
@morrisedmonds7425
@morrisedmonds7425 18 дней назад
@@sartingarage8045 The regulator was not grounded, so I added a ground wire as per your video. I checked the DC voltage at both the regulator purple and the harness connector at the front of the engine by the spark plug, and I got 3.5vdc at each location with the key switch "on", but not running. Does it make any difference which way the regulator connector plugged into the regulator?
@sartingarage8045
@sartingarage8045 17 дней назад
Sounds like you either have a power problem to key Switch or the Key Switch itself is bad. Here is a key Switch Test Video. ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-rOqwb0KaHQI.html After testing key switch make sure you have battery Voltage to the B terminal in Connector that plugs into Key Switch.
@morrisedmonds7425
@morrisedmonds7425 17 дней назад
@@sartingarage8045 Thanks, heading to that video right now.
@samuelavelar2700
@samuelavelar2700 3 года назад
Nice
@connellfarm315
@connellfarm315 Год назад
Great video.. I have a question. If ur stator is working (30-50vac) but ur regulator output (center pin) is under 12vdc with engine running. Would u say the regulator is bad?
@sartingarage8045
@sartingarage8045 Год назад
@connellfarm315 No It could be but there has to be battery voltage to that wire or will not charge correctly. Also base of regulator has to be grounded. Watch my Kawasaki Charging Video will help alot I know it's Kawasaki But works the same way as Kohler, Just wires are connected different This is link ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-zRwkKNGkymU.html Also this is a Ground test Video Shows you how to test the Voltage regulator Base Ground. ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-ogV7e8x0tZY.html
@connellfarm315
@connellfarm315 Год назад
@@sartingarage8045 thank you so much
@mohmedhosny6094
@mohmedhosny6094 2 года назад
Hi If stator out but 30.2ac V At full throttle Regulator 1DCV Kindly your advice
@sartingarage8045
@sartingarage8045 2 года назад
Turn Key to on position Check Voltage at Regulator where you are getting 1 volt You should have battery Voltage at this wire with just Key On Position. Engine Not Started If there is NO battery voltage at this connection Your problem is wiring to and from key Switch or a faulty key switch. I have a Key Switch Test Video
@Matthewcook572
@Matthewcook572 2 месяца назад
What spade on switch dose the purple wire go to can't get a kholer cammand to charge
@sartingarage8045
@sartingarage8045 2 месяца назад
@Matthewcook572 The purple wire goes to the center Terminal
@TheWaterbug101
@TheWaterbug101 Год назад
Hello, my vintage tractor from the 1970s has a 10 HP iron block Kohler engine that stopped charging the battery. I replaced both the stator and voltage regulator and it still doesn't charge even though the new regulator is properly grounded to the frame. Could it be that the flywheel magnets are too weak to produce voltage? The ohm meter reading shows fluctuwating numbers on the readout from the regulator with the engine running at high speed. Thanks
@sartingarage8045
@sartingarage8045 Год назад
@TheWaterbug101 That is a possibility. It's been awhile since I've had my hands on one like you have But if one magnet is missing or has came loose inside the flywheel. You will get erratic readings on the meter. I think I would pull that Flywheel and atleast check the magnets. Tip: Those Magnets are Push Pull Push pull all the way around the Flywheel. So if you have a magnet and put it to the first magnet, It will either draw magnet to it or you will feel it try to push magnet away. So if the first one is pull Next one will be Push Next one will be pull All the way around
@Maverick4841
@Maverick4841 4 года назад
So I know I need a new battery for my Scag as I've had to put the battery charger on every time I start the mower. Today I started mowing and probably mowed 30 minutes and had to stop and move our trampoline, pushed in electric PTO, set brake and got off mower to moved trampoline. Got back on mower released brake and engaged PTO and the engine started missing bad, disengaged PTO and missing went away. Idled engine down engaged PTO and the missing was gone, gave her full power and and was able to mow another minutes and she died right there in the yard. I would like to know your thoughts on this matter. Tomorrow I will be replacing the battery for sure to start with.
@sartingarage8045
@sartingarage8045 4 года назад
There is two things I can think of most likely wrong. 1st you do need to check the charging system, 2nd thing is if it is a twin cylinder engine, sounds like you may be running on one cylinder. The engine will still run great, but will be low on power. So when you are engaging the Pto. Engine doesnt have enough power to turn the blades as far as spinning the blades. But at the same time if battery is really low This will also cause engine to stall qhen blades are engaged. There is not enough Power in battery to keep PTO clutch engaged
@Maverick4841
@Maverick4841 4 года назад
@@sartingarage8045 Replaced the battery today and it fired right up. I was able to finish mowing without any problems. You were right about the battery not having enough power to keep PTO engaged. I will follow your video on How to Test Kohler Charging System for a more thorough diagnoses and make sure there isn't another underling issue. I can't thank you enough as you saved me a lot of money and more importantly TIME.
@darylwade2335
@darylwade2335 3 года назад
My Kohler 25 hp PS-SV730-3022 Husqvarna riding mower is giving me grief. I went to start it, the battery was completely dead, and it my battery charger advises that there isn't a battery hooking up to it when I tried to charge the battery. I suspect that the voltage rectifier/regulator has failed and allows AC current into the battery. Two brand new batteries, no idea. Would this be a possible solution? The tractor will not turn over, even with a booster battery. Any ideas?
@sartingarage8045
@sartingarage8045 3 года назад
That is possible. Also spark voltage from ignition Coil can go thru ground causing this. Usually will give a high voltage reading especially at the pto clutch connector. Running up to 90 volts. Will damage the clutch eventually. Once you get a good charged battery in the mower. You need to check for this voltage at the clutch. If it is High at the clutch If I remember correctly will be a negative Voltage because power is going thru Ground. Take shroud off of engine and disconnect single wire to ignition coil ( usually Black wire) Put shroud back on for safety from flywheel. Start the engine and see if High voltage is gone at pto clutch. If voltage is Now Normal, Replace ignition Coil
@boco9252
@boco9252 2 года назад
My kohler 30hp runs as long as the key is engaged in the start position, when I release the switch to run mode, it dies every time. I replaced starter switch, and checked all the safety shutoff things like the emergency brake, seat switch, etc. Any ideas why it quits when I release the starter?
@sartingarage8045
@sartingarage8045 2 года назад
Sounds like something inside key switch is connecting to ground Could be for ignition Coil or Carburetor Solenoid. Carburetor Solenoid would be loosing power/voltage or loosing ground. Ignition Coil would be grounding out With key in On position check for voltage on the Carburetor Soleniod. If it has one wire positive lead on wire a d ground other lead. If it has two wires one lead on each wire.
@robertholt8522
@robertholt8522 3 месяца назад
My Kohler 23hp is only getting around 20-23 volts ac from the stator even though just replaced it with a new unit. Any idea what else the issue could be?
@sartingarage8045
@sartingarage8045 3 месяца назад
@robertholt8522 I would check magnets on flywheel. The magnets need to be evenly spaced and each magnet is push pull push pull
@christophermaurer1271
@christophermaurer1271 3 года назад
To add to my previous comment, the first A/C test test was only showing 26 volts. Is that a problem ? as the second test was showing 14.5 volts on a fully charged battery.
@sartingarage8045
@sartingarage8045 3 года назад
As long as your getting the correct 14.5 DC volt output , 26 AC volts from stator ahould be OK
@kaydencapps5497
@kaydencapps5497 3 года назад
I have a kohler engine and it is putting out 19.7 V is that still fine
@sartingarage8045
@sartingarage8045 3 года назад
If that is DC to the battery Its Not OK If it's AC out of stator I would say that's a bit low on voltage.
@Mike-su8si
@Mike-su8si Месяц назад
I don't have no meter so I'll just clean the stuff up or plug one on from one of my other Kohlers shoot a little oil on after cleaning then see if the battery has charge in it after its all cleaned is the best way i can do without a meter for right now any battery put on it is not enough juice to start it without a charger hooked up The batteries are new they do fine on my tractor mowers without a charger hooked up
@sartingarage8045
@sartingarage8045 Месяц назад
That's probably the best you can do without a Multimeter to test to actually see if mower is or isn't charging. There are some links in Description for Several Multimeters from Cheap ones to best ones.
@cobhc1986
@cobhc1986 4 года назад
I need a little bit of help. I've engine swapped mowers before, but just the other day my dad blew the briggs engine in his AYP craftsman, then got a 16.5hp kohler engine that says craftsman on it but was on a MTD when we got it. The regulator was completely bypassed. I got to looking at the stator wires, yellow and black, and noticed that there was a factory installed diode or what I assume was a diode on the black wire that had blown and melted. So my question is, do these kohlers need both a diode and rectifier on the charging wire, or are we dealing with mixed up parts? Can I wire it up using the diode from the briggs or do I need to use the regulator that wasnt hooked up? This mower has manual deck engagement and AC headlights.
@sartingarage8045
@sartingarage8045 4 года назад
Let me get this right The Briggs Engine has No external voltage regulator/Rectifier. But the Kohler engine has a voltage regulator. If this is the case You will use the center pin on voltage regulator to go to the mower factory connector which should only be 2 wire connector. You will have to figure out which wire in the two pin connector to connect center wire of voltage regulator to. One of the wires in the two pin connector is ground. Dont want to connect it to ground. Best to pull key switch and usually terminal A1 on key switch Use a ohm meter and find the wire in the two pin connector that connects to A1 on key switch. This will be the wire that you will connect center pin from voltage regulator to. May have to put other wire in the 2 pin connector to ground for it to charge
@cobhc1986
@cobhc1986 4 года назад
@@sartingarage8045 Yes the original briggs only had a diode on the charging wire, no rectifier. The kohler appears to have had a diode that blew and melted the wire, as well as the 3 pin rectifier, which wasn't even hooked up. Someone had messed with the wiring before. I'm just wondering if the kohler needs both the diode that blew as well as the rectifier, or if some kohlers had only a diode and this fan shroud with the rectifier came off another engine.
@sartingarage8045
@sartingarage8045 4 года назад
The Kohlers Engines came with both. The difference would be if mower has electric Pto Clutch or Electric Pto engagement. Those will have a better charging system on them which will have a rectifier/voltage regulator. Mowers with a lever to engage blades Most would not have a voltage regulator and charging system is less output. Most mowers now have electric pto
@Koontz40SW
@Koontz40SW Год назад
I’m getting 15.62 volts at the battery and voltage regulator when the engine is off. Brand new battery. Engine runs, but the key won’t start it. I can hear it click in the on position but the start position does nothing. I have to put a jumper in the starter and it fires right up. Turning the key off shuts it off. When running, the voltage at the battery and at the regulator is 17.6-17.9. I replaced the voltage regulator and get the same exact readings. I tested the stator from a Koehler video and it showed to be good. Is the high voltage (17.6+ volts) when running a sign of something else or are my switches just fried? John Deere stx38 yellow deck, about 25 years old. Thanks.
@sartingarage8045
@sartingarage8045 Год назад
Test your keyswitch Multimeter on Ohms Test terminal B and S with key in start position.
@Koontz40SW
@Koontz40SW Год назад
I get nothing on the meter doing that. Gonna replace the switch and see if that does it. Thanks Sartin!
@Koontz40SW
@Koontz40SW 11 месяцев назад
@@sartingarage8045 this ended up being the starter relay. Starts right up and runs like a top.
Далее
3.5M❤️ #thankyou #shorts
00:16
Просмотров 726 тыс.
How to Test and Repair a Lawn Tractor Charging System
25:06
How To Test a 3 Phase Regulator/Rectifier
6:51
Просмотров 658 тыс.
KOHLER Command Charging System Test
2:49
Просмотров 20 тыс.
Riding Mower Charging System Check and Repair
7:37
Просмотров 48 тыс.
Slow Mo Spiral
0:11
Просмотров 44 млн