REASONS YOU MIGHT NEED TO SERVICE / REPAIR THE DIVERTER VALVE:
- Your radiators are getting warm whilst using the hot water
- Your boiler is overheating and cutting out when trying to use the heating
- The hot water is not getting as hot as it used to (it's sharing heat with the radiators)
- It's leaking
A simple test to see if your diverter valve could possibly be a problem:
1.) Run your hot water
2.) Put your hand on the central heating flow pipe underneath the boiler
If the flow pipe is getting hot then either your diverter valve is faulty or your plate heat exchanger is blocked and forcing it's self back through the diverter and down the flow pipe.
This video is for these boiler models
MAIN
- Main Combi 24
- Main Combi 24 HE
- Main Combi 30 HE
BAXI
- Baxi Combi 105E
- Baxi Combi 105HE
- Baxi Combi 80 ECO
- Baxi Combi 80 MAXFLUE
- Baxi Combi 80E
POTTERTON
- Potterton Performa 24
- Potterton Performa 24 ECO HE
- Potterton Performa 28
- Potterton Performa 30 HE
& Any similar models I might have forgotten