that pipe and cover was winning! there's always days like that, everything goes wrong and slows you down. mumbles something about murphy's laws whilst shaking fist and giving the finger....
Bill is good old Anerican HVAC mechanic,.....very few left.....I start in 1988 till today but dont considered myself other than a svc tech on the field.....saludos
Merry Christmas John hoping life is good for you and your family. Miss your videos but I know you said you were going on your own and hoping you’ve been so busy that you don’t have time to upload videos
Also for all you new guys out there if this is going to be one of your contracted buildings always budget to keep an extra belt in the unit and also always date the belt with a silver or white paint marker makes life so much easier
For good practice it's always easier to start with open the blower section just to see if you have a loose belt or if it's direct drive and also the limit will be right there above the tubes you can check for corroded wires melted wires do all that before the hard stuff
Welcome back ee miss ur videos bro.,,,when u say limit switch I said EFM relay or contactor.....is that Motor 3 phase or single,,,,,seems 3.,,,now ur board help u out as I get help w boards here in Florida. 20 degrees seriously is 85 here. Come down man😏
FYI to everybody also if you knew meaning that you're under 10 years in the service know that the sheave and the pulley misalignment can make the belt flip and can also on the sheave end if it's worn out and it's not at a v shape it'll eat up the sides of the belt which will cause it to kink and snap which would also cause this issue also if somebody put the belt on too tight on an a belt that will result in a snap AX was made as an actual stronger capable belt but they also make a connectable belt adjustable so you can make it any size you want I haven't seen it in the last couple years but that was a lifesaver to keep a box of that on the truck
🤯🤯🤯🤯🤯 oh my God please for the love of God don't ever rotate a door on its corner on an EPDM roof that will tear right through that thing like it's paper
When you hooked your meter to the board, you’re just reading amps, correct? I watched the video is pieces so I may have missed whether or not you mentioned it
I have a single pipe steam system that I suspect leaking somewhere just can't find where. Located in bergen county NJ let me know if you are still sevicing
How comes they don't have no gas regulator on that thing I remember back in the days there's gas regulator then tubes would always be blocked either somebody broke one off and ice froze in the hole or a little spiders or bees crawled into the tube you'd have to clear it out same goes with so carrier I think it was or maybe it was York thing was carrier though The pilot tube where it has the mixing opening would get spiders building an ass right there stopping the gas from going to the pilot
6:30 if there gonna make that rtu same as the weather maker why the hell didn’t they make the heating components the same that shieeet sucks usually I’m twisting my back lol
Know we missed you Bill. Best of luck and blessings with your own HVAC company. I told my wife years ago that you were the type of guy, with your skills, that should have your own company. I expect you to be wildly successful. Your positive attitude, attention to detail, and moral compass will see you through.