No Heat Sunday Service Call Hacking Dead Motor Back To Life 

The HVAC Hacker
Подписаться 32 тыс.
Просмотров 7 тыс.
50% 1

I am on a no heat hot air furnace service car. And this hot air heating system call not enough heat. This furnace is twin together another furnace attached a really large ductwork. I find that one of the furnaces is not coming on. I have power to my inducer motor, yet the motor won’t run. I try to move the fan on the outside of it. It is very tight. Therefore I turn the furnace off. Next I remove the inducer motor. I gave it some time to cool off.
Now that the inducer motor has cooled off. I start to lubricate the bearings on the motor. The stater and the motor also looks a little better. I spray a little bit of grease into there also. I reinstall the inducer motor into the hot air furnace. I reconnect steel work trickle power to it. After that I start up the furnace and the fan motor starts running. Therefore I monitor the operation of the fan motor, watching the Amps. The motor was rated 1.8amps and the motor was pulling 1.5 A. Then I advise the customer we have to order them a new inducer motor, because I couldn’t promise this motor would last. This is just to get them by since it was about 15° outside.

Опубликовано:

 

25 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 31   
@jasonjohnsonHVAC
@jasonjohnsonHVAC 2 года назад
I done this many times before....had a few people cancel their replacement and it always failed again.....put them on the back of the call list...."get there when I can"
@thehvachacker
@thehvachacker 2 года назад
Last one I did there is a vid of it lasted 9 months. Told them it was temp my repair and they should replace. Yet that was a church who always cried poverty
@broken_font1881
@broken_font1881 2 года назад
@@thehvachacker that's why if you know they're cheap... never give them a temporary fix!! Cheap can wait in the cold a day or two 😂🤣
@nilsonnilson6764
@nilsonnilson6764 2 года назад
Hello friend, here in Brazil the devices are different but this always happens too
@williamdyckman9704
@williamdyckman9704 2 года назад
That Fluid Film is great stuff !
@thehvachacker
@thehvachacker 2 года назад
I been impressed so far by fluid film
@--harry_
@--harry_ 2 года назад
We sold all our customers with those space guard 201 filters the upgrade kit to upgrade them to the 213. So much better filter. I hated having to do all those combs on the 201. They are so brittle now and break all the time. 213 is like an accordion and slides in on a metal track and upgrades filtration to merv 13.
@keepthinking2666
@keepthinking2666 Год назад
Use superzilla green wonder oil, Best I found yet just as good as the old zoom spout if anybody remembers that stuff but the best part about the superzilla is that it's non-flammable biodegradable and safe also to use on food equipment
@theoldbigmoose
@theoldbigmoose 2 года назад
I am sure the heat was appreciated!
@TheLOD2010
@TheLOD2010 2 года назад
That was a clever fix to win time for getting the spare 🙂
@keepthinking2666
@keepthinking2666 Год назад
Some twin units are set up a stage so first stage heat second stage heat third stage heat fourth stage have seen crazy things over my two decades
@Eddy63
@Eddy63 2 года назад
Good little vid ... Thx for sharing ...
@douro20
@douro20 Год назад
Not much different from the Payne unit I used to have to contend with...except these are updraft rather than downdraft. (I know Payne is owned by Carrier)
@AmericanFarmerHVAC2024
@AmericanFarmerHVAC2024 2 года назад
Those heat exchangers are more than likely cracked. The right one had alot of disturbance. These model carriers always crack, pull the main limits and look right where the cell makes a loop. They always crack there.
@keithstone3728
@keithstone3728 2 года назад
Been doing that for the last 15 16 years don't know how many I found cracked
@AmericanFarmerHVAC2024
@AmericanFarmerHVAC2024 2 года назад
@@keithstone3728 I found one that was from 2000 oddly enough it was ok... Because it was paired to a heat pump... So it had half the use
@Sparky18059
@Sparky18059 Год назад
What's the name of the penetrating pray you used?
@Tony.gamez6
@Tony.gamez6 2 года назад
Those are some big ducks. I wonder why it needs two furnaces
@scottpalmer2551
@scottpalmer2551 2 года назад
Generator question How do i set weekly test on kohler
@keepthinking2666
@keepthinking2666 Год назад
Also not sure if you noticed that first unit on the left check the flames or should I say check the gas pressure those flames did not look correct it a lot of dirty flames going through there I thought it may have been just a dust particles from the door but it had a lot of kickback
@realestateservicessaleshea99
@realestateservicessaleshea99 2 года назад
😎👍🏻 🥃🥃🍺🍺🍺🎯🏌🏻‍♀️ Stay safe. Retired (werk'n)keyboard super tech. Wear your safety glasses!
@zacharyreed45
@zacharyreed45 2 года назад
Junk, whole assembly was loose? Maybe bearing, maybe wheel rubbing? Sounds like trash but, hate to replace just motor to find out assembly is junk for whatever reason.
@thehvachacker
@thehvachacker 2 года назад
I replace the inducer assembly. I don’t write up motor. Yet it was running smooth when I left. The rotor looked beat up on the motor. The customer wanted it replaced, and it was 2 days later. Still running and not over amping.
@donnellbaxter8050
@donnellbaxter8050 2 года назад
Will compressor oil work.
@adamlogan384
@adamlogan384 2 года назад
Is that a Camelion light you got there?
@thehvachacker
@thehvachacker 2 года назад
It’s a braum folding slim bar from harbor freight been using this lamp for years. Great lamp and fits nicely in my bag
@philq1324
@philq1324 2 года назад
should we be checking those heat exchangers on a call like this ? after hours etc. no hate genuinely curious. I know sometimes its a pain to get to
@TheGhettoLobster
@TheGhettoLobster 2 года назад
Honestly on these ones its easy as pulling the high limit and you'll probably find a crack on the dimple
@donnellbaxter8050
@donnellbaxter8050 2 года назад
Will compressor oil work.
@donnellbaxter8050
@donnellbaxter8050 2 года назад
What was the part that yo put on your drill.
@Dunkdamonk
@Dunkdamonk 2 года назад
Milwaukee 90 impact bit
Далее
No Heat Service Call T-Stat Satisfied Upon Arrival
36:11
No Heat Burners Keeps Cutting Out
37:50
Просмотров 87 тыс.
Cute kitty gadgets 💛
00:24
Просмотров 11 млн
Inducer Motor Not Coming On - How to Check It
29:28
Просмотров 593 тыс.
Boiler Not Firing Up Stuck Flue Draft Damper
17:23
Просмотров 31 тыс.
Gas Furnace Turning Off? Here's What Might Be Happening
15:56
NO HEAT? Top 10 Problems on a Gas Furnace Package Unit!
13:18
Capacitor and Hard Start Myths Busted
28:41
Просмотров 227 тыс.
Failed Compressors - Don't JUST REPLACE IT
24:59
Просмотров 62 тыс.