Vaillant Arotherm Plus Air Source Heat Pump 2021 

Dore Woodman
Подписаться 1,9 тыс.
Просмотров 10 тыс.
50% 1

In this episode we look at the Vaillant Arotherm Plus in more detail, the general package you would look to purchase and data and guidelines for a typical installation.
We also take a quick peek inside the unit to see what components are in place and what generates and provides the heating and hot water to the property.
Please share, subscribe and hit that notification button.
#SeriousAboutSustainability #sustainability #sustainable #sustainablehomes#heating #homeheating #airsourceheatpump #gasboiler #boiler #heatpump#renewableenergy #renewableheating #renewable #renewables #netzero #climatechange#climatecrisis #homeowners #homeownerlife #warmth #globalwarming #carbonfootprint #affordablewarmth

Опубликовано:

 

21 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 31   
@TrevHutt
@TrevHutt 4 месяца назад
Excellent
@TimiStyle93
@TimiStyle93 2 года назад
Great video. What is your take on the uniTower?
@debs55
@debs55 Месяц назад
Hi bill do you leave your emersion on all the time because so far I'm not thrilled with it as radiators coming on when it feels like it.
@handle1196
@handle1196 2 года назад
Do you still need planning for a self build that has recent planning permission accepted? Any idea of the cost of planning for a ASHP? Are you adding multiple room stats per floor for multi zone, or adding one stat per floor that opens or closes all zones on that floor, and are you using weather compensation or load compensation? weather
@myatix1
@myatix1 Год назад
Nice video! It would be nice to see a detailed installation of a vaillant ashp
@dorewoodman
@dorewoodman Год назад
Hi Alan, we do have a couple of videos on our channel with a full installation
@blackmagnetec
@blackmagnetec 2 года назад
what brand is the compressor?
@hvacdesignsolutions
@hvacdesignsolutions 2 года назад
How are those SCOPs calculated?
@skiiddy
@skiiddy 3 года назад
I’m impressed. Could you explain how the aeroTherm plus is able to generate heat flows at 75 degrees as advertised by Vaillant?
@dorewoodman
@dorewoodman 3 года назад
Hi Simon, Thank you. It is all down to the refrigerant used, it has the ability to heat water at higher temperatures without the need to use a larger quantity of refrigerant and a larger compressor therefore enabling the heat pumps to work and comply for domestic uses etc. Of course the higher the temperature of the flow used for heating the less efficiency you get from the units themselves and I would always err on the side of caution with looking at heat pumps to supply these high temperatures. I hope that helps. Jason
@skiiddy
@skiiddy 3 года назад
@@dorewoodman thank you Jason. I’m building a passive house next year and been advised that we would need a 12kw system to accommodate four en-suite bathrooms and a the house overall will extend to almost 300m2. I’ve only ever had vaillant in my properties and would likely only ever use their kit however, I’m torn between this system and Viessmans Vitovalor, in essence a fuel cell which, although relies on natural gas, converts it to hydrogen and simultaneously, generates electricity. Do you install these?
@dorewoodman
@dorewoodman 3 года назад
@@skiiddy the Viessmann Vitovalor is certainly an interesting alternative. I think it comes down to a few variables; Will planning allow for effectively a fossil fuelled heating system? Is the area in which you are building the property "off grid" i.e no gas supply? Will a gas supply need to be installed to the property? With that in mind, comparative install costs? Do you wish to achieve a carbon zero house? What grants will be available etc? Which area of the country are you based Simon?
@UpsideDownFork
@UpsideDownFork Год назад
Great content but get yourself a microphone. Rode videomic pro or something similar will make all the difference. Or a rode wireless go. There are so many easy options to improve it.
@markgaudie80
@markgaudie80 Год назад
I’m hoping I don’t need a buffer with my Vaillant install. Take up more space than I would like in my small utility.
@dorewoodman
@dorewoodman Год назад
What size is the heat pump? Rads or UFH?
@markgaudie80
@markgaudie80 Год назад
@@dorewoodman we have 30 meter squared of under heating in the lounge/kitchen/diner. Then 2 older lounges with 2 massive double connector rads about 12000 plus BTU. 3 bedroom on the first floor with large double convector rads then a 4th bedroom with electric under floor heating and a massive towel rad in the en-suite. The bedroom itself has a 6 foot tall decorative double rad.
@markgaudie80
@markgaudie80 Год назад
Half of the downstairs is new build with all 150mm insulation in the floors and walls.
@markgaudie80
@markgaudie80 Год назад
We have all brand new windows and doors and the loft conversion was only completed Feb this year so all to latest building regs. The only other thing we could do to the house is to dig all the concrete floors up downstairs in the 2 old lounges and hallway then insulate the floors and lay new slab. This wouldn’t be a viable option for us with expensive solid oak parquet flooring in these areas. Or maybe rip all the new glazing out for triple glazing.
@glenphillips6634
@glenphillips6634 3 года назад
Hi I’ve just had the 12kw system installed and was wondering how hot the ufh pipes should be ,coming into the manifold they don’t seem to be getting warm but the pumps are working I would of thought it should be coming in around 45 degrees my installer says it is working but will be a slow process as in if it’s 5degrees in the pipe the heat would be 5 degrees more and increase as necessary which doesn’t seem as efficient as it’s on constantly could you give me any advice please
@dorewoodman
@dorewoodman 3 года назад
Hi Glen, Thank you for your comment. A couple of points: The heat pump is usually set up with a 'Heat Curve' and uses its weather compensation components to determine the flow temperature. As the temperature outside increases, the flow temperature from the heat pump decreases and vice versa as outdoor temperatures fall. You should get 45 degree flow temperatures when the outdoor temps are cold enough to allow it, if that is how the design parameters are set up. In the summer the heat pump shouldn't be on at all for heating; if for any reason it was the flow temperature could be as low as 15-17 degrees. That said your heating system is not only determined by the flow temperatures but also the thermostat temperatures. If your thermostats for the UFH are set to 20 - 21 degrees and you have achieved these temperatures then there will be no need for the heating to be on at all, if that is the case and the pumps on the UFH manifolds are still running then it may be incorrectly installed/wired. I hope that helps.
@glenphillips6634
@glenphillips6634 3 года назад
@@dorewoodman thank you I think that explains it better I was just trying to test it and had set the temp to 24 but the pipes just didn’t seem to get any warmer so was really confused as to if it was working
@dorewoodman
@dorewoodman 3 года назад
@@glenphillips6634 You are welcome.
@highlandjournalart654
@highlandjournalart654 Год назад
We’ve just had this unit fitted, we’ve got hot water but can’t get the central heating on despite outside temperature falling and a high demand one chosen. Any ideas?
@dorewoodman
@dorewoodman Год назад
There are a number things that could be influencing that ... Is the outdoor sensor reading the outdoor temperature correctly? ..... which thermostat do you have controlling the heating? .... is it set up correctly under the settings? .... Do you have a buffer and are the thermistors positioned correctly? .... How many heating zones do you have?
@highlandjournalart654
@highlandjournalart654 Год назад
@@dorewoodman thank you for your reply, I’ve found a fault logged re outdoor sensor so suspect it’s that.
@zalkhirsan9481
@zalkhirsan9481 3 года назад
Are these the pressure cylinders size on left and right
@dorewoodman
@dorewoodman 3 года назад
Hi Z Alkhirsan, The cylinder to the left of the heat pump as you look at it is a Buffer Tank which can be in different capacities and the Hot Water Cylinder is to the right. The one in this video is a 45 litre buffer tank and a 250 litre cylinder for this particular installation. The Hot Water Cylinders can range from 150 to 300 litres typically but that is not to say for much larger properties 500 to 800 litre cylinders are available. Many thanks, Jason
@zalkhirsan9481
@zalkhirsan9481 3 года назад
@@dorewoodman thanks for that so both are needed
@dorewoodman
@dorewoodman 3 года назад
@@zalkhirsan9481 generally yes, with this particular heat pump.
@paddyeason9677
@paddyeason9677 Год назад
Interesting. I’m surprised how messy and ugly the layout was on the inside… looks like something from a car boot sale!
@beatacosgrovephotography283
@beatacosgrovephotography283 2 года назад
Great video, could you please tell me if - these are the the best products in the market now? -Vaillant aroTHERM plus 12kW (with interface) and Vaillant uniTOWER ? Also what would be the volume of the air source heat pump outdoor compressor unit (including housing) measured in cubic(m3) for the above products?
Далее
Mitsubishi Ecodan Air Source Heat Pumps
39:20
Просмотров 73 тыс.
Камень, ножницы, нейронка
00:33
Просмотров 113 тыс.
Strong cat !! 😱😱
00:19
Просмотров 1,4 млн
НОВАЯ ПАСХАЛКА В ЯНДЕКСЕ
00:20
Просмотров 664 тыс.
Heat Pumps The Ugly Truth - The Rebuttal
18:57
Просмотров 54 тыс.
Vaillant Arotherm Plus Installation
11:51
Просмотров 16 тыс.
aroTHERM plus installation guide
7:59
Просмотров 40 тыс.
Can you swap a Gas boiler for an Air Source Heat Pump?
21:21
How Does A Heat Pump Work? Alpha Hybrid Heat Pump ASHP
1:19:11
Камень, ножницы, нейронка
00:33
Просмотров 113 тыс.