Тёмный

weil mclain CGI gas boiler with running issues 

steven lavimoniere
Подписаться 200 тыс.
Просмотров 32 тыс.
50% 1

weil mclain CGI gas boiler with running issues
merch = teespring.com/stores/steve-lav
/ stevenlavimoniere
lavimoniere productions llc
subscribe to my channel
/ @stevenlavimoniere
lavimoniereplumbingandheating....

Хобби

Опубликовано:

 

9 окт 2020

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 32   
@J-Colt
@J-Colt 3 года назад
Enjoying the boiler vids. Thanks for posting Steven!
@WeatherNut27
@WeatherNut27 3 года назад
Cool to see how to change the flame sensor. Enjoy the weekend Steve!
@nmccw3245
@nmccw3245 5 месяцев назад
As the owner of a CGi-3, I’m yelling Steve, the CGi is an intermittent pilot / electronic ignition boiler! 😜 Mines been running great for 25 years.
@fourqs
@fourqs 3 года назад
Thanks for the video, Steve and Molly! Have a great weekend!
@williamdyckman9704
@williamdyckman9704 3 года назад
Enjoyed the video, your experience shows with getting the job done !
@rodneyskinner7741
@rodneyskinner7741 3 года назад
Great job as always Steve
@RJG772
@RJG772 Год назад
"Good enough for this neighborhood" got me laughing.
@PRO4XKEV
@PRO4XKEV 3 года назад
Looks like some new windshield wipers are needed for winter. I can see they do not wipe the rain off very well. Probably dry rubber blades.
@antoniosantiago2770
@antoniosantiago2770 3 года назад
Checking the sensor with micro amps takes the guessing out.
@rjwinz
@rjwinz 3 года назад
I got those in the truck. Lol.
@nadiagallagher9159
@nadiagallagher9159 3 года назад
The dog is so, so cute!
@fuqewetoo7148
@fuqewetoo7148 3 года назад
K. Cast iron boilers always run high co until the system heats up. Also that Honeywell intermittent pilot gas valve is prone to opening main valve on call for pilot. Most times they light np. Other times.....boom
@donnierobertson3088
@donnierobertson3088 3 года назад
Nice job and video
@kylebass4635
@kylebass4635 3 года назад
Tell her to add a zero to the replacement cost.
@pauly540
@pauly540 3 года назад
Who else misses the 'Value Testers' ad, at the beginning of Steve's videos?
@dwight.bennett
@dwight.bennett 3 года назад
@@JD987abc it was discussed in a Q&A a while back, related to the shutdown earlier this year.
@cclpokerpoker5619
@cclpokerpoker5619 3 года назад
Always have a question why we try to clean the flame sensor and it only worth like $5. Should we just change a new one?
@Fireship1
@Fireship1 3 года назад
Funny that she wanted to replace that boiler. It didn’t look that old.
@zekenzy6486
@zekenzy6486 3 года назад
Great Video. Have a nice weekend . Thank you for sharing ^_^
@geeoye
@geeoye 3 года назад
Steve, not sure if it helps but I have the exact same boiler in my house that would turn on and off all day long. After doing some research online, I found out the boiler temperature was set to 140 so as soon it reached 140, it would shut it off and then start again after 10-15 minutes. I raised the temp to about 200 and now more more On and off issue. Just my 2 cents since you help so many of us learning from your videos.
@bobbywenger5595
@bobbywenger5595 3 года назад
You done a hell of a good job on that stove but I believe she probably need a new one in the future
@elpuffy11
@elpuffy11 3 года назад
Great video, you just saved me 495$. Thank you!
@inhibited44
@inhibited44 2 года назад
I am watching this because HVAC guys are stretched thin here Nov 2021 and gas company hasn't called back about an appointment to have someone clean the flame sensor. I took classes in oil burner in 1990. This can't be much worse.
@vickaminski
@vickaminski Год назад
I have the same issue right now with Is a Weil McLean CGA 4 I replace the flame sensor unit And it kicks on runs for a few then shuts off kicks on runs for a few and shuts off it does not stay running long enough to generate any heat. I don't know what to look for next any suggestions what to check. Sometimes it goes through the start of process but never actually fires up sometimes it fires up runs for a few stops and then tries to kick on again. I'm just mechanically inclined homeowner Not an HVAC specialist.
@bobbywenger5595
@bobbywenger5595 3 года назад
Steve bring some rain towards our way Missouri
@dsciarrino3663
@dsciarrino3663 Год назад
Have 1 from 1985.
@jeffsmith2022
@jeffsmith2022 3 года назад
Looks like a rather small boiler there...
@richardkirts7298
@richardkirts7298 3 года назад
Why replace it? If taken care good for another 15 yrs.
@mikeg3888
@mikeg3888 3 года назад
Seems like a perfectly good boiler, you will get 25 years out of it with regular maintenance
@potbelliedolman8939
@potbelliedolman8939 3 года назад
I didn't hear it cutting on and off from East Texas!! Ha ha!
@markpowell1031
@markpowell1031 3 года назад
Second comment
Далее
LEAKING BOILER WITH MULTIPLE ISSUES ADDRESSED
43:35
Просмотров 54 тыс.
Steam Boiler Piping Tips
9:33
Просмотров 65 тыс.
НЕ ДЕЛАЙТЕ УКЛАДКИ В САЛОНАХ
00:43
Weil McLain Boiler inspection
29:57
Просмотров 14 тыс.
Weil-McLain CGI Install
6:26
Просмотров 29 тыс.
GAS BOILER NO HEAT FOR FOUR DAYS
27:18
Просмотров 39 тыс.
WEIL MCLAIN STEAM BOILER TROUBLESHOOTING
18:21
Просмотров 3,5 тыс.
GAS BOILER NO HEAT CALL ODD FIND
16:58
Просмотров 18 тыс.
Crucial Knowledge To Heat Pump Troubleshooting
14:15
Просмотров 18 тыс.