See how easy it is to connect, use and program the excellent (XSY-AT1)variable frequency drive inverter from Banggood to a new 3 phase 1HP motor. For use on my Chinese Mini Lathe & Myford ML7. SEE BUYING LINKS BELOW FOR THIS MODEL BUT CHECK WHAT VOLTAGE & PHASE TYPE OF VFD YOU NEED BEFORE BUYING.
2.2KW 220V AC 12A Single Phase Variable Frequency Inverter General -- goo.gl/sbQccx
US Warehouse -- goo.gl/6gKvN9

Опубликовано:

 

25 май 2018

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 233   
@SteveJordan
@SteveJordan Год назад
facebook.com/steve.jordan.3766952
@28gwdavies
@28gwdavies 5 лет назад
Hi Steve, thank you so much for taking the mystery out of inverters and 3 phase. I will be making the pulley carrier spindle and finding a 3 phase motor as soon as you show the video of it. I am actually sat in my shed right now waiting for my new Chinese lathe to be delivered! ... keep the videos coming Steve, they are very informative and the links to everything are invaluable.
@markamy357
@markamy357 5 лет назад
Thanks Steve, Mine arrived yesterday, I have a heap of 1 and 3 phase motors and now with your help I will drive everything
@cmonster6
@cmonster6 6 лет назад
Excellent setup Steve,you now have a super mini lathe
@Man-in-da-shed
@Man-in-da-shed 6 лет назад
Thank you Steve. As I'm still on with my reassembly I've been looking at motors and VFD. Interesting .
@johnbucknall2394
@johnbucknall2394 6 лет назад
Great stuff, been waiting for this for my own personal use later.
@grahameblankley3813
@grahameblankley3813 6 лет назад
Hi Steve, you timed this video just right for me! My Chester 9-20 lathe 18yrs old now, motor failed, so I'll do same as you have done, thanks so much, from Cov' Uk.
@SteveJordan
@SteveJordan 6 лет назад
Hi Grahame Thanks, Just check out the above comments, as I had a couple of things configured wrong which I had to alter. When I do the next video I will mention this. I have just finished putting everything on the lathe now and its all back running.... I am totally impressed with it. Regards Steve
@lawrenceogden8682
@lawrenceogden8682 3 года назад
following you word for word brilliant video and brilliant vfd got mine delivered in ten days
@scroungasworkshop4663
@scroungasworkshop4663 3 года назад
Good demo Steve, I have the identical VFD and motor and found it just as easy to set up. Cheers Stuart 🇦🇺
@gubelly
@gubelly 6 лет назад
Very interesting and inspiring. Thanks I look foreward to your use of the control terminals.
6 лет назад
Thanks for explaining how to connect 3 phase motor to single phase mains.
@AtticusDraco
@AtticusDraco 6 лет назад
I was unaware that you planned to do this on the Myford as well Good show
@SteveJordan
@SteveJordan 6 лет назад
Hi Yes I hope to do this at some point. I'm thinking about whether it will be an advantage though, as the top speed on the ML7 is only meant to go up to about 1170RPM for the bearing type.
@tinkermouse-scottrussell3738
@tinkermouse-scottrussell3738 6 лет назад
Nice project Steve, my friend has a similar set up on his lathe but suffers with low speed torque and a high squeal at certain RPM's. From Elliot Lake Ontario Canada.
@stemer1149
@stemer1149 6 лет назад
Excellent video. I have a VFD on my 1941 Flott drill press, works really well. I have connected a potentiometer and buttons for forward, reverse and stop, all of these run on 5/12V so you can use low voltage versions.
@SteveJordan
@SteveJordan 6 лет назад
Hi Thanks....Was it easy to connect all of these? Regards Steve
@stemer1149
@stemer1149 6 лет назад
Steve Jordan Hi Steve, yes, very easy, it was described in the VFD manual. I have HuanYang 1.5kW and it has I believe 6 freely programmable button inputs where you cann connect a simple push button to each and connect them all to ground. Then you program the VFD for each of the buttons with one of the available functions, e.g. forward, reverse and stop (but thre are more, e.g. preselects for given rpm etc.) ie you define a param in the firmware specifying which function to execute when the button is pressed. The potentiometer is just wired with 0 and 10V and the middle contact which are 3 dedicated connections on the VFD. It should be similiar for your VFD as they are all quite alike. Take care. Steffen
@SteveJordan
@SteveJordan 6 лет назад
Hi Steffen, What about an emergency stop button?
@stemer1149
@stemer1149 6 лет назад
Hi Steve, I have not wired an emergency button, however, the parameter list for the multi-input offers both a normal stop function and emergency stop, so I could add another button for an emergency stop. Or, I could just put another button parallel to the existing stop button (wired OR) and use a more prominent aka RED button housing for that one. One could even put a "do not press this button" notice up (Terry Pratchet..) However, for real emergency stop (that stops the machine rather quickly) one needs a serious amps braking resistor to convert the kinetic energy of the machine into heat, I believe, and these are quite bulky and expensive, used on big milling machines and such. Besides active braking, one could program if the motor coast to stop or is decelerated by the VFD and the ramp times for start and stop functions, so with changing those parameters one can decelerate faster if so required.
@Ringwolf1
@Ringwolf1 3 года назад
Excellent video , thanks you for your detailed explanation .
@nikond90ful1
@nikond90ful1 6 лет назад
Thanks for the video Steve, Very interesting as always.
@rayfalcone6897
@rayfalcone6897 6 лет назад
hi steve, nice review,and video,thanks for sharing.......
@serdarxxx1073
@serdarxxx1073 5 лет назад
The Fan of the VFD is very noisy,louder than the Motor.Must change the Fan.Great Vid,thank you😉
@lawrenceogden2162
@lawrenceogden2162 2 года назад
great video
@davidpope1218
@davidpope1218 5 лет назад
Hello, great video by the way. Very informative , I have one of these and have misplaced instructions, wondering if you could give me the parameters for this and how to set up with the motor I want to control... being an amateur electrician...
@umargul5644
@umargul5644 4 года назад
Well done sir
@yangamy8829
@yangamy8829 3 года назад
very good show
@qasemalmansuri2414
@qasemalmansuri2414 5 лет назад
Great Video ... Any information where to find manual for 3 phase 3kw inverter AT3-04K0X
@laurentthommet8313
@laurentthommet8313 6 лет назад
Hi Steeve I have done a similar modification on my lathe. I have added an potentiometer and a forward / backward switch directly on my lathe. It"s more convenient to control . I'm sure that your inverter has that option for external control. Greetings from France Laurent
@SteveJordan
@SteveJordan 6 лет назад
Hi Laurent My lathe already has a potentiometer for now, a separate unit that I fitted some time ago, but I do hope to add one plus the forward/reverse switch to the VFD and lathe at some point. Regards Steve
@SteveJordan
@SteveJordan 6 лет назад
Hi Laurent, Yes mine has the connection block for external control. I have a few wiring diagrams for this block in the instructions, but it will take me a while to work it all out. Unless I find a video showing this...
@SasquaPlatypus
@SasquaPlatypus 5 лет назад
I recently picked up a vfd from that same at series and unfortunately it came with no documentation... Any idea where I can get a copy of the manual or barring that, what's the function number that will switch control from the panel to the external terminals so I can wire up external start/stop switches? Thanks!
@Alex-lh8pm
@Alex-lh8pm 4 года назад
I have this current vfd and I need help. I get an error one which is amp overload... Motor is 3HP 8.5A rated 220V 3 phase. I have the same VFD as you but we hooked it up 1 phase input to 3 phase output. Everytime I switch my lathe into gear the error arises. Please let me know how to fix this
@leaflee2066
@leaflee2066 6 лет назад
Hi Steve, great video I've been building up a selection of tools to get back in to home engineering and your videos have provided a wealth of information, thank you. Just a quick question do you have a link for the motor you are using in this video, as I am after this upgrade for my ml7. thanks in advance for any help.
@SteveJordan
@SteveJordan 6 лет назад
Hi Thanks www.ebay.co.uk/itm/3-PHASE-ELECTRIC-MOTOR-0-37KW-TO-11KW-1400RPM-2800RPM-2-POLE-4-POLE-ALUMINIUM/191770300135?ssPageName=STRK%3AMEBIDX%3AIT&var=490794456079&_trksid=p2057872.m2749.l2649
@redditroom2981
@redditroom2981 5 лет назад
Steve, do you know how to increase the motor torque with this inverter? I can see it must be Program 70-72 but can't seem to increase the torque?
@en2oh
@en2oh Год назад
thanks for sharing this! is there a 110vac to 3 phase 110v?
@shaunwhiteley3544
@shaunwhiteley3544 6 лет назад
Thanks another great video, quick question, when you were showing the jog, can you jog, 90 degrees or 45 degrees for example so you could use it for indexing? If so fancy doing a video on it 😀. Cheers
@chipcity3016
@chipcity3016 4 года назад
No this would require a proper servo drive and an encoder for positioning feed back.
@ramkitty
@ramkitty 6 лет назад
can you please publish the manual on gdrive or something. I am looking at this same unit and want to make sure it will work
@theoboeman
@theoboeman 3 года назад
HI Steve, thanks for sharing this video, I'm looking for a new motor for my S7, can you tell me which model motor this is? Thanks!
@tobyw9573
@tobyw9573 3 года назад
A low RPM motor has the advantage of requiring a fully twice the diameter of a 3600 rpm motor which is easier on the belt(s) for the same input speed on the lathe in this case.
@jas20per
@jas20per 2 года назад
External control cables coming out of the top of the VFD does not lend its self to cable neatness, I have noticed that the majority of low Kw VFD they exit from the bottom as the motor supply cables do.
@vladimirmarkovic1369
@vladimirmarkovic1369 6 лет назад
Hi Steve, I'm learning a lot from your videos, thank you and please don't stop making them, quick question would this size motor and vfd work on my super 7? Can the motor be mounted instead of the crompton? Thank you
@SteveJordan
@SteveJordan 6 лет назад
Hi Vladimir Thanks, Yes it would be great. I hope to do the same set-up on my Myford ML7 at a later date. Regards Steve
@dronesvisionsaeriennes
@dronesvisionsaeriennes 4 года назад
so directly attached to the round case alu to the converter earth ...?
@sarkistatuljan2950
@sarkistatuljan2950 5 месяцев назад
Question - is it possible to set up the XSY-AT1 frequency converter so that when turned on it works at high speed, about 2-3 minutes, but after 2-3 minutes of operation to a pre-set low speed? A pool water pump is connected to the XSY-AT1 frequency converter.
@gofai1
@gofai1 2 года назад
good afternoon... thank you very much for your information. I'm having problems with my VFD by any chance could you tell me from p65 to p83, what parameters they have?
@carllie4848
@carllie4848 6 лет назад
I will also say thanks for all you videos . I'm new inn hobbylathe'. I learn a lot of you. How low rpm do you need, and will use? If the motor runs to low = No cooling?
@lastick56
@lastick56 3 года назад
Thats right. The cooling of most cheap motors is not enough if ran at low rpm. You could mount an external powerd fan.
@davecox900
@davecox900 Год назад
Ste Can you wire that in to Mach 3 for constant surface speed on Cnc turn
@kenzetterdahl1248
@kenzetterdahl1248 4 года назад
Hi Steve! Thank's for your educational videos. Dare I buy a lathe now 🙂? Regards Ken Sweden
@martik778
@martik778 2 года назад
Which setting will reduce the ramp-up time to full speed? Mine take 2 seconds to get up to speed
@SL-ez7qn
@SL-ez7qn 11 месяцев назад
Nice review. What’s the voltage rating of your motor, 220v or 380v?
@jbrawo9732
@jbrawo9732 3 года назад
Hello, I have a problem with the same inverter, namely after connecting according to the instructions and starting the motor starts to vibrate, do you know what could be the reason
@albertlavorata9359
@albertlavorata9359 2 года назад
So.... Here in America we have 110 volts per leg, so if you want 220 you have two separate wires and a neutral, BUT, this drive only gives you one terminal for "220v". So what do you do?
@msuleman973
@msuleman973 7 месяцев назад
Hi any idea how we connect potentiometer with this device
@maximojavi2433
@maximojavi2433 2 года назад
If your drive has rs port -485, have you been able to configure it to work with the modbus rtu protocol? and if so, what parameters are used? a greeting
@hkhjg1734
@hkhjg1734 5 лет назад
hey guys, i just found 6 3phase motors in the dumpster. Any ideas about what i could do with them?
@razvanvalentin1426
@razvanvalentin1426 2 года назад
hi u can tell me if u running whit a low revolution of motor he have the same torque like he running fast?
@abumoslemtamer7331
@abumoslemtamer7331 2 года назад
If a motor that works only on 380 volts is connected to a suitable inverter (220 volts input, 380 output)... will the motor run at its full efficiency without decreasing torque or speed? Thanks!
@vetdoc35
@vetdoc35 4 года назад
Wjat would i give for this Set to wotlrk like in the Video......but i am a dump Vet and probably would never get this like you did...... is there maybe somewhere where you can buy this so finished assambled like you show rhis?
@kingsupra5023
@kingsupra5023 3 года назад
Hi Is it a good quilty? Also can I use it for 380v
@ro8v28
@ro8v28 4 года назад
We were given a xsy-at1. We have no manual. Could we get a copy of the manual that you scanned? Please.
@MavG
@MavG 10 месяцев назад
I'm looking to buy this model on september 2023. After all theses years, this chinese model is a good one?, they are still manufacturing?.
@trabbipaul
@trabbipaul 4 года назад
Hello. I want to build by myself a Beltgrinder for making Knives. My question ,can i use like this VFD for my Projekt ??. The E Motor ,2850 U on 380V,1,5 hp. Here some Videos about a beltgrinder u know. Since Paul.
@amirinam2933
@amirinam2933 5 лет назад
does it have braking system??
@christianwolf5842
@christianwolf5842 4 года назад
Just one remark: The GND (not neutral) MUST BE CONNECTED under ANY circumstances. I do not know why the swich changed the measurement at around 4:05. That should not happen! GND must be connected anytime.
@IljaSara
@IljaSara 4 года назад
I came here to say the same.
@nicolaspillot5789
@nicolaspillot5789 4 года назад
@Christian Wolf my guess is that in the box is a 3 contact switch, and he wired phase neutral and earth on the switch, thus disconnecting chassis ground from the earth when the switch is off
@christianwolf5842
@christianwolf5842 4 года назад
@@nicolaspillot5789 That might be true but is definitively a security issue! There should be no need to break the GND line. What happens if the switch (only on GND) fails? Or it connects slightly after the mains line. You have a metal case, do not think too much of it and have contact with it while turing on. This will fry you in just the moment between connection of mains line and GND connection (which will trigger the fuse in this case just too late). At least in Germany you ALWAYS bypass the PE aka GND by any switches.
@afsharkalabi4680
@afsharkalabi4680 Год назад
Hello Sir I've got the error 7 and it is in stop mode and I can't do anything and I need your advise to fix or reset the AT1. I would really appreciate your time. Please and thanks
@richardplane2155
@richardplane2155 4 года назад
Thanks Steve I've installed the exact same VFD on a table saw. Everything is fine except the motor hasn't nearly the same todrque as it did under direct three phase. Are there any settings i can tweak to make it better? Maybe not and fm this comes with the territory of fixing up single phase to make a synthetic three phase ...... Thanks for any ideas....
@MrWizards1974
@MrWizards1974 4 года назад
Without a rotary phase converter you lose 1/3 of the power from the motor with a VFD like this. Thats why when you buy a rotary phase converter you get it with 1.5 - 2 times the HP of the motor you are running.
@k4be.
@k4be. 3 года назад
It is possible that your motor is configured for Y connection (400V) and the VFD outputs 230V so it needs Delta connection.
@kencroft7933
@kencroft7933 5 лет назад
Another good one Steve. Do you have a source for reasonably priced 3 phase motors? Do Banggood sell them?
@SteveJordan
@SteveJordan 5 лет назад
Hi I bought mine on Ebay the new 1HP 3 phase are about £98 post free. It pays off over time as they cost less to run, so I've heard
@hkhjg1734
@hkhjg1734 5 лет назад
still looking for a 3 phase motor?
@billpierce6792
@billpierce6792 2 года назад
Hi Steve .. love your videos and I've by chance bought the same VFD already wired up to a 1 hp motor, unfortunately it came with no instructions to adjust the parameters.. would I be able to trouble you for a copy?
@SteveJordan
@SteveJordan 2 года назад
Hi Bill if you go on my RU-vid community page tab and scroll down you will see a PDF file with the instructions you can download or copy. Regards Steve
@msuleman973
@msuleman973 4 месяца назад
Hi I have same device it’s showing error 4 any idea how we can solve that issue
@BritishLifeSafetySystems
@BritishLifeSafetySystems 3 года назад
What’s the size of the inner cores? 6mm?
@nickarmstrong3042
@nickarmstrong3042 10 месяцев назад
Hi Steve, Can you make this VFD auto start after power loss (ie after a power cut) Thanks Nick
@SteveJordan
@SteveJordan 10 месяцев назад
Sorry, I don't know about that. Maybe someone else does.
@stevewilloughby2169
@stevewilloughby2169 6 лет назад
It seemed to me that you had to turn on the power switch to get contact for the earth (safety) ground. Was this by design? In US nothing is supposed to interrupt the safety ground. Might be a chance to get a nasty shock.
@SteveJordan
@SteveJordan 6 лет назад
Hi Steve, No that was my mistake...I have altered that now to be continuous...Regards Steve
@petemacrae5982
@petemacrae5982 6 лет назад
Good video! Is there any interferance on other electrical appliances when the VFD is running, like ,say your TV etc. Cheers
@SteveJordan
@SteveJordan 6 лет назад
Hi Pete, Thanks....no, it all seems to be ok with no interference...Regards Steve
@MrObiwankanoobi
@MrObiwankanoobi 3 года назад
sweet gee-bus watching you jab your finger in that box made me feel things.
@ronbianca9722
@ronbianca9722 3 года назад
Good video Steve! How is the low end torque using the 3 phase?
@SteveJordan
@SteveJordan 3 года назад
Hi Ron Thanks the torque is excellent.
@victoryxists
@victoryxists 2 года назад
Hello Steve. Do you know how to reset the default settings. We had someone mess with ours and it needs to be reset to begin again. Thank you.
@SteveJordan
@SteveJordan 2 года назад
Hi Victor. I don't know how to set the default settings. It maybe in the instructions. There is a copy of those in PDF form on my RU-vid community page.
@johnziello8797
@johnziello8797 Год назад
Hey There I'm hoping you can help me out, I have the same VFD but lost my manual and need to set it up again. Need all the programming codes ect.
@SteveJordan
@SteveJordan Год назад
Hi John, If you click on my RU-vid community page tab and scroll down you will find a PDF file with the inverter instructions. It may not be in page order but it's all there. Regards Steve
@michaelmayo3127
@michaelmayo3127 4 года назад
This is OK for the UK but, most European households have both single and three phase power as their standard domestic power installation.So those Europeans watching this very informative video should check their supply criterion before ordering a converter because you most probably will need a converter with a 380 volt supply and not 240 volt.
@samuronkanen1307
@samuronkanen1307 5 лет назад
Hi Steve. Do you get good torque in low speed? I bought the same VFD as yours based on this video and got it working, but get low torque out of my 500W motor. The parameters I have set are motor RPM for 1400 and torque compensation to 50 (I think it was setting 72), minimum frequency to 10hz and max frequency to 100hz. Other than that I think I'm running on default settings.
@SteveJordan
@SteveJordan 5 лет назад
Hi Samu, The torque seems to be ok on mine but I don't push it too hard with very low speeds and large drills, anything over 1". I have my lathe set so that the belts will slip if anything were to crash, or if a drill became too blunt though. I notice the RPM slowing a bit sometimes on the display but nothing that would concern me.
@samuronkanen1307
@samuronkanen1307 5 лет назад
OK thanks Steve. It could also be due to my motor. I don't understand much about these things. My motor is a two speed motor, and who knows it that affects the torque somehow. @@SteveJordan
@carllie4848
@carllie4848 6 лет назад
Hi Thank's for the vid' How good will the torque be at low speed? 100 rpm, 300rpm?
@SteveJordan
@SteveJordan 6 лет назад
Hi Carl, Thanks....I hope to show this in coming videos.
@forgecro
@forgecro 5 лет назад
hello! great video , I have a question , just got xsy-at1 in manual it says to connect delta circuit on the motor , you didnt made clip with connection so is it star or delta? thanks
@forgecro
@forgecro 5 лет назад
just saw the other video...what an idiot I am you explained everything great...
@SteveJordan
@SteveJordan 5 лет назад
Hi It was my mistake in the first video.....Thanks for watching
@MrTrollBeast
@MrTrollBeast 6 лет назад
Hi I have to exact same VFD, I would like to know which program changes the maximum frequency and the maximum voltage, also does the VFD compensate for the change. I’m make a free energy device where I feed power at a higher frequency to a motor and the motor spins a generator that gives me higher power at a lower frequency.
@has997
@has997 4 года назад
Thanks for video. How you connect motor star or delta ? How much the voltage of two output phases ?
@k4be.
@k4be. 3 года назад
Likely delta connection for 230/400V motor
@exbof19
@exbof19 5 лет назад
Very helpful video. Many thanks. I’ve recently bought an AT4 model from same manufacturer using Banggood. According to spec it is supposed to be an input 220v single phase and output 380v 3 phase model. If correct it is useful for driving older single voltage star point 3 phase motors without having to locate star point in windings and convert to Delta. I’m wanting to drive a 380v 3ph 1/2hp motor with this 3hp vfd. I would like to limit the current this vfd can output in order to protect the motor but I don’t see a parameter which permits me to limit the current to the motor’s plated full load current (1.05 amps) The instructions I received cover AT1, AT2, AT3, and AT4 models. I’m wondering whether you limited the output current and if so which parameter you used? Another strange things is that the AT4 model does not have an earthing terminal.
@84Prerunner
@84Prerunner 5 лет назад
my AT1 does have current limit option. It doesnt limit the current per say, but it trips over current if it goes over what you input.
@andrewfirman5437
@andrewfirman5437 5 лет назад
84Prerunner Which parameter limits the current? I'm having difficulty understanding some of the Chinese English. I've connected my AT4 up to a 380 volt star configured motor (only 1/2hp). Only parameters I changed were from 60hz to 50hz and motor rpm to 1425. Motor seems to run OK but don't know whether it has full power as currently just testing on bench.
@84Prerunner
@84Prerunner 5 лет назад
Andrew Firman P78 through P85 are all over current settings. P24 is allowed time for over current
@exbof19
@exbof19 5 лет назад
84Prerunner Thanks. The default values seem somewhat arbitrary - I’ll play around with some of those and see what happens.
@pf2302
@pf2302 3 года назад
is vector driver?
@SuperGrover
@SuperGrover 6 лет назад
Hi Steve. Is there any chance of a link to the copy of your instructions? Mine's a different brand, the instructions are rubbish and I can't work out how to adjust the torque compensation, your instructions might give me a clue...
@SteveJordan
@SteveJordan 6 лет назад
The Torque settings are on (P70 & P72 Torque compensation). (P71 Torque compensation voltage).
@SuperGrover
@SuperGrover 6 лет назад
Yeah I know where my settings are at, there's just no information on how to correctly use them. Trial and error is all I got...
@alfredprestwick7774
@alfredprestwick7774 Год назад
Thanks for your video. Could you please explain something that confuses me. At 1:49 the still image shows your motor wired as STAR and not as DELTA, yet the illustration in the instruction manual shows AT1 must be wired as DELTA. Regarding your electronic tacho, it relies on reflected light, so is never going to work well on a curved surface. Better to put your target reflection window on the end of the shaft, then it is flat, not curved.
@SteveJordan
@SteveJordan Год назад
I made a mistake on that, and corrected it later in a follow-up comment.
@alfredprestwick7774
@alfredprestwick7774 Год назад
@@SteveJordan Ok. Thanks. There is an AT-4 description in the manual which added to the confusion, but I have worked out it must have meant to say AT-3
@MrFosdan
@MrFosdan 2 года назад
Looks like you have it wired in star for 415v? The motor might run in delta for 220v.
@SteveJordan
@SteveJordan 2 года назад
Hi I changed that soon after making the video. I updated it in the following one. Regards Steve
@whidbeyman
@whidbeyman 6 лет назад
Why was it necessary to actuate the switch to check your earth connections for continuity? Does this mean that your earth wire is switched? It should be a continuous connection, unswitched. That way, any switch contact failures cannot result in a disconnected earth.
@SteveJordan
@SteveJordan 6 лет назад
I changed that to continuous already...Regards Steve
@blackbearbowie8162
@blackbearbowie8162 5 лет назад
hi love your content, iv hooked my vfd like the one in your vid to a motor I pickup and iv got error code 1 on the readout can these things be reset ? the booklet says nothing about resetting what do you think? regards
@charisantonatos9156
@charisantonatos9156 5 лет назад
Hello sir. Did you find a solution on how to reset to factory settings? Thank you in advance.
@StormbringerMM
@StormbringerMM 4 года назад
Error code one is possibly triggered because your 3 phase motor is in the Star or “Wye” configuration and if you’re trying to start it at say, 60Hz, you won’t have enough starting torque and you’ll get a current spike. So this error code is protecting your device. Press reset, or unplug and reset, and then turn the frequency dial to Zero, start the process again, with your motor switched on, and slowly increase the frequency. If your motor is in delta configuration you’ll be fine.
@joeygonzo
@joeygonzo 4 года назад
how about wiring forward, rev and off switches ?
@SteveJordan
@SteveJordan 4 года назад
I didn't need to on this one as the VFD is directly above the Myford lathe and near. I did wire up forward and reverse etc on my Chinese Mini Lathe VFD though.
@davespringate5469
@davespringate5469 5 лет назад
Hi Steve could you put a link up for that motor please ?
@SteveJordan
@SteveJordan 5 лет назад
www.ebay.co.uk/itm/3-PHASE-ELECTRIC-MOTOR-0-09KW-TO-11KW-1400RPM-2800RPM-THREE-PHASE-MOTORS-400V/192580042652?hash=item2cd6aa3f9c:m:m8NAG17pMR2cqvXc-dUilvw
@mamerto1339
@mamerto1339 2 года назад
How much is this available
@brunomtn
@brunomtn 5 лет назад
Hi Steve, so... can we set all parameters of the motor on this VFD? like RPM, VOLT, A, Hz....
@SteveJordan
@SteveJordan 5 лет назад
Hi Bruno.....Yes you can.
@5b4aezmarinoscyprus71
@5b4aezmarinoscyprus71 6 лет назад
Have you checked if this VFD has the option for emergency stop mushroom button, so you can stop the motor instantly....
@SteveJordan
@SteveJordan 6 лет назад
Yes I'm I have just ordered one.
@5b4aezmarinoscyprus71
@5b4aezmarinoscyprus71 6 лет назад
Steve Jordan Very nice. When you just hook it up, let as know how it works.... 😁
@DoctorJ3kyll
@DoctorJ3kyll 6 лет назад
What connections are needed for the estop and do you have a link to the one you have ordered?
@44Celt
@44Celt 6 лет назад
Can you run this size VFD/motor from a 13 amp household socket?
@SteveJordan
@SteveJordan 6 лет назад
Hi yes that is exactly what this model is designed for which is great for us in the UK.
@BritishLifeSafetySystems
@BritishLifeSafetySystems 3 года назад
Heya, where did you get the cable for the motor from? I have an air raid siren and I’ll be running it on a VFD but idk what size cable I need
@SteveJordan
@SteveJordan 3 года назад
Hi I just bought a 3 phase extension lead and cut some off that. It was the cheapest way at the time. Have you searched eBay?
@BritishLifeSafetySystems
@BritishLifeSafetySystems 3 года назад
@@SteveJordanits 3HP, 3ph, 2850rpm and its running current is 5A
@philiprogers5772
@philiprogers5772 6 лет назад
Please can you tell me the parameter to alter the torque. I fitted a similar one of these to my pedestal drill, I have plenty of speed but hardly any torque.
@SteveJordan
@SteveJordan 6 лет назад
Hi Phillip, The AT1 VFDs parameters for torque are p71/p72/p73. Most people though make the mistake that you can alter these and get 'very high torque' which usually isn't possible. An acceptable torque should first be attained by using the correct sizes pulleys Ie..You should have A very large one on the main spindle drive, (mine is around 6.7" in diameter). You can see this in my next video. The VFD's parameter settings won't compensate if you have the pulley configuration wrong as the parameters are only for small adjustments.
@philiprogers5772
@philiprogers5772 6 лет назад
Thanks for the reply, I very much appreciate it. For P71-Action time of TIMER. P72-Simple PLC auto-operating option and P73-The first period time set of auto-operating. I was expecting to be able to increase the current output in some way. Any thoughts? I do totally agree with the larger pulley idea however I have the largest I can fit and I have only managed about 3:1. This aside I have a 2.2kW inverter driving a 2kW 3 phase motor and I can stop the pillar drill chuck with a gloved hand. I feel that it is so underpowered that there is some parameter I have not set correctly.
@alt-w7130
@alt-w7130 4 года назад
Good ideas, what the make and model of the 3 phase motor you use.
@SteveJordan
@SteveJordan 4 года назад
Hi Thanks....It an Electro Tech 3 phase 1HP (1400 RPM) motor with B3 foot mount. You can get them on Ebay. eBay item number:192580042652 Regards Steve
@alt-w7130
@alt-w7130 4 года назад
@@SteveJordan thanks
@cherhanamiya1
@cherhanamiya1 4 года назад
Hi Steve I have noticed that you’ve said that your VGD is 2.2Kw & the Motor is 1Hp. I have read that VFD’s should be sized to the motor ! Ie I have a 0.75kw motor and though that I should have to get a 0.75kw VFD. Any thoughts about this ?
@SteveJordan
@SteveJordan 4 года назад
As far as I know you can have more Kw than required but not less than required.
@cherhanamiya1
@cherhanamiya1 4 года назад
Hmmm I’ve been looking for that information as I have a 2.2kw VFD. ( same as yours ) but as I’d not found any information that testified as to your belief. I was therefore reluctant to try the 2.2kw VFD WITH MY 0.75kw Motor. Am I correct in thinking that there is no information that I’ve noticed in the attached user information regarding “inserting motor Dataplate information “ into the parameters ?
@wgh011
@wgh011 4 года назад
@@cherhanamiya1 I'm running the Tec .75kw 1hp motor (4 pole) with a 2.2 vfd, gives the option of a bigger motor later on, less stress on the components too, I've had no problems.
@bk1468
@bk1468 6 лет назад
Keep in mind these low cost VFD's are not to be confused with real vector drive VFD's. Which means in simplest terms; no closed loop torque control. This means your motor will perform at rated power only in very narrow frequency range. Low speeds will current-saturate winding, and high speed will experience sharp power drop-off. So keep your motor speed at rated +/- 20Hz for reliable performance.
@paultoman889
@paultoman889 6 лет назад
B Smith Perhaps you could elaborate, and confirm, as I suspect, that I've made a big mistake. I'm in Canada and I just bought a low cost VFD from a US supplier. It's a GS2 11P0 from Automation Direct (if you care to look it up). I discovered very quickly that I cannot run the motor at the speed I would use for single-point threading. With the gear reduction in my lathe (Sieg SC4) that's about 3Hz. Without adjusting the torque-boost or slip- compensation I can stop the chuck from spinning with my finger. If I adjust either of those setting it makes it hard to stop the chuck, but the VFD quickly overloads and shuts down. So, have a made a huge mistake? Many thanks, if you respond to this! Desperate for help here. The vendor hasn't been terribly helpful or reassuring to this point.
@SteveJordan
@SteveJordan 6 лет назад
Well I haven't had any problems with the low cost Chinese VFD's. They run my motors perfectly at all speeds with excellent torque.
@bk1468
@bk1468 6 лет назад
Limitations of non-vector VFD's is well characterized and documented in motor drive theory. It is important to understand performance differences between various drive methodologies prior to application. You may get lucky and experience reasonable performance; depending on your system and expectations. However you may also end up with system supplying insufficient torque at desired speed, or overheating, etc. Closed-loop motor drive systems incorporate multiple feedback elements and calibrate drive electrical parameters to properly match system variants. Vector drives can adapt and perform optimally over wide variations in application parameters (speed, load, temperature, motor parameter variants, and dynamic variances). This is why true vector-drives are more expensive. Chinese VFD's are also built with $15.00 assembly budget; you will find internal components at below minimal standard for AC high-voltage applications. Forget about UL or CE certifications; these stamps are counterfeited routinely on imported equipment. Try requesting certification certificate from manufacturer, or even identifying actual manufacturer for most Chinese brands.
@paultoman889
@paultoman889 6 лет назад
Steve Jordan Thank you for replying. All of the RU-vid vids I've seen seem to be very much like yours; no problems, no issues. That's what I was expecting as well. That wasn't my experience. I'm a bit lost now.
@paultoman889
@paultoman889 6 лет назад
B Smith I was aware that these things have limitations, but following the lead of Steve, AvE and several others I wasn't expecting to encounter them (whatever they are). There has to be something won't with either the drive or the second hand motor I'm using.
@johnbucknall2394
@johnbucknall2394 6 лет назад
Where did you purchase the motor? No link in description lol.
@SteveJordan
@SteveJordan 6 лет назад
Hi I bought this new on Ebay. There's loads of different sellers. I went for one where in the description it was said they are suitable for use with VFD's.
@RuiSjm
@RuiSjm 4 года назад
Hi, can you share the user manual? Mine came without it... Thanks a lot
@SteveJordan
@SteveJordan 4 года назад
I will do a PDF copy and put it on my RU-vid Community page later if I get time.
@steveu235
@steveu235 5 лет назад
How do you vary the Torque? Thank you
@SteveJordan
@SteveJordan 5 лет назад
I haven't looked into that as I gained very high torque with the pulley sizes I chose.
@michaelfgmail7506
@michaelfgmail7506 6 лет назад
Hi Steve I've learnt a lot from your videos. But I was surprised to see you have connected the motor in “star” those small motors are usually dual voltage ie “star” configuration for 415 volts 3 phase (UK mains) and “Delta” for 240 volts 3 phase, which VFD’s usually output. Check the voltage output for you're VFD and the motor rating plate on the motor, if it is indeed 3 phase at 220/230 volts and the motor is dual voltage rearrange the links at the motor for “delta” In your purchasing link one of the photos shows a motor connected this way, but calls in “Triangle” connection, some thing lost in translation! I've been unable to check the above as I can't find the manual on line and the video does not show the motor rating plate. Michael
@SteveJordan
@SteveJordan 6 лет назад
Hi Michael....Well thank you very much! It is a dual voltage motor and I have just changed the links around. This is my first experience with 3 phase equipment. The actual instructions that came with the VFD doesn't show the product listing photo/diagram, where it shows the actual motor link configuration. When I bought the motor it came as set as in the video and I wrongly presumed that it was correct. This is why I overlooked this. Thank you so much for pointing this out....Regards Steve
@michaelfgmail7506
@michaelfgmail7506 6 лет назад
Hi Steve Your welcome. One other thing I meant to comment on, it appeared that the isolator needed to be on for earth continuity, this is wrong, here in the UK no switches are allowed in earthing wires as they can go open circuit leaving the metal work unprotected. Michael
@SteveJordan
@SteveJordan 6 лет назад
Ok thanks... I will change that as well......Regards Steve
@SteveJordan
@SteveJordan 6 лет назад
Hi Michael, Do you know if is ok to connect a 3 phase emergency stop button between the VFD output to the motor?
@michaelfgmail7506
@michaelfgmail7506 6 лет назад
Steve Jordan No need to do it that way, and not recommended as inverters don't like to see open circuit on there output terminals, as this causes large surges (voltage spikes from the collapsing magnetic fields) which can blow the electronics. I'm pretty sure you'll find that you can simply remove a link from the control side of inverter to fit the emergency stop, which would be in the low voltage control circuit. This wiring should be kept separate from any other wiring. Best read the manual first though, I would like a copy of it, as I will probably be doing the same job some time, then I could read through as well, 2 heads always better than 1 Michael
@ramkunwarkilak9592
@ramkunwarkilak9592 3 года назад
15 hp 1 phaes ac 3phaes ac h kay
@dronesvisionsaeriennes
@dronesvisionsaeriennes 4 года назад
Hi Steve, i'd like to buy the same VFD for my CnC which wil be equipped with ER11 spindle with 46V DC, 500W, 12000 Rpm and 220V at home...But i only have 2 wires on it...red ( + ) and black (- )...Is it possible to connect it but without Earth...? Thank's a lot...Phil
@SteveJordan
@SteveJordan 4 года назад
You could but it would be best to put an earth wire from the motor housing I think although I only know basic electronics.
@tribal165
@tribal165 5 лет назад
Hi did you configure the motor to run 240 delta or leave it in the star configuration?
@SteveJordan
@SteveJordan 5 лет назад
Hi I changed it to Delta.
@tribal165
@tribal165 5 лет назад
Steve Jordan ok thanks, I’ve got exactly the same setup except I think my motor is a bit bigger 2.2kw I’ve configured mine in star and delta and doesn’t seem to make any difference, I was just wondering if it matters or shortens the life of the vfd?
@tribal165
@tribal165 5 лет назад
Or motor
@wgh011
@wgh011 4 года назад
@@tribal165 Use Delta, VFD prefers it and I ead somewhere that the motor should be in the delta config, I think it's in the instructions for the motor too.
Далее
LM 9300
0:42
Просмотров 2,2 тыс.
다리에 힘이 풀려버린 슈슈 (NG Ver.)
00:11
Просмотров 2,7 млн
O-Zone - Numa Numa yei на русском!🤓
00:56
Просмотров 177 тыс.
Вопрос Ребром: Сергей Бурунов 2
1:03:47
HS127 Inverter type AT1 setup and test
18:49
Просмотров 13 тыс.
Myford ML7 3 Phase VFD Inverter Set-Up & Working
11:50
Lathe VFD 1: How to wire a 3-Phase motor and VFD
24:16
Просмотров 308 тыс.