Welcome to HVAC with John Israel RU-vid Channel. On this channel I Bring you along on HVAC Service calls, HVAC Installs, HVAC Maintenance and pretty much anything else HVAC related. Enjoy and thanks for watching.

Опубликовано:

 

3 июл 2022

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 53   
@grantbrown2432
@grantbrown2432 2 года назад
John i just installed a condenser today and made $1,500 and im 19. Love ur videos bro you inspire me alot to work more even on weekends.!!!
@jtg1528
@jtg1528 2 года назад
I’m thinking about joining. Are you with the union or do you work for a Corporation?
@dc9039
@dc9039 2 года назад
If you made $1,500 profit to replace a condenser; you overcharged your customer.
@grantbrown2432
@grantbrown2432 2 года назад
@@dc9039 no i didnt who are you telling me i overcharged?
@grantbrown2432
@grantbrown2432 2 года назад
@@dc9039 it was a used condenser so it was %100 profit u jackass
@thedirtysouth4980
@thedirtysouth4980 2 года назад
Mars 2 and Jard is identical... a call back in a box. I threw every cap and relay I had on my truck in the dumpster.
@Eddy63
@Eddy63 2 года назад
Good little vid John ... I noticed you have a cute little helper with ya ... Thx for sharing
@williamsmith6
@williamsmith6 Год назад
Pull vacuum on a system with a leak?
@stevevlahos1
@stevevlahos1 2 года назад
How hard is it to get a HVAC license.
@scotta9114
@scotta9114 2 года назад
Nice video John. You are looking great. If MO99 is $100 a pound, I wonder what my old jug of R22 is worth in my garage? I think it only has 20# left in it. I'm not a Tech by trade. I bought a jug of R22 from a Tech that was fired while doing a service call. He asked me if I wanted anything from his Truck and sold me the R22. I had a Duplex in Washington State that had 2 down R22 Heat Pumps. No one would service them so I did. Bought around $1k of test equipment and went to work. Both were working great and then I eventually sold the place.
@cameronrimmer2819
@cameronrimmer2819 2 года назад
I see some goodmana’s
@picklerix6162
@picklerix6162 2 года назад
I bought some Goodman 16 SEER equipment for my house right before the pandemic hit. I was really surprised that the condensing unit looked like an Amana with an ECM fan motor and the wire grate on top. The equipment package came with a GMVC furnace which has to be programmed via a Bluetooth connection with Goodman’s CoolCloud app.
@brianporter4352
@brianporter4352 2 года назад
I work for a Rheem dealer in NC and yes both the condenser and the evaporation coils on the pkg units are micro channel. Have been i think since 2015. We have had a few issues, but overall they've held up pretty well. We shall see when the warranty runs out.
@princesspumpkinpanty
@princesspumpkinpanty 2 года назад
Not to confuse people but if you get a rheem ac for your house, it will not be and has never been micro channel.
@johnisraelhvac2019
@johnisraelhvac2019 2 года назад
On package units yes sir it is
@princesspumpkinpanty
@princesspumpkinpanty 2 года назад
@@johnisraelhvac2019 never put a packaged unit on a residential unit. take 3 seconds to read a comment before you reply
@andrewpierce2213
@andrewpierce2213 2 года назад
Rheem uses micro channel evaps and condensers ONLY on their RACA14/15 straight cool and RGEA14/15 gas package units for the residential market. Their residential packaged heat pumps are tube and fin condenser and evaporator coils.
@brianporter4352
@brianporter4352 2 года назад
@@andrewpierce2213 Yes you are right, the 14 and 15 SEER packs are micro channel. The 16 SEER is conventional coil, as is the pkg HP's. Sorry should've clarified that. Thanks for setting the record straight.
@thedirtysouth4980
@thedirtysouth4980 2 года назад
You’ll be back with that Jard crap. Buy some Amrad please...
@gainestruk1
@gainestruk1 2 года назад
I really like your content, also you are looking good after the surgery !
@joshl.158
@joshl.158 2 года назад
Looking good John.
@crazydan2327
@crazydan2327 Год назад
Around here u are not supposed to be putting refrigerant into a leaking system u are supposed to recover existing refrigerant and leave if customer doesn't want to have leak repaired be responsible and do the right thing u are directly venting refrigerant
@johnisraelhvac2019
@johnisraelhvac2019 Год назад
Please come on my show
@crazydan2327
@crazydan2327 Год назад
How would I do that u should have at least put a super seal in that old clunker it costs 100 charge 200 and make an extra hundo
@johnisraelhvac2019
@johnisraelhvac2019 Год назад
@@crazydan2327 it’s very easy. I’m tired of your keyboard cowboy shit. I want to embarrass you live on RU-vid
@crazydan2327
@crazydan2327 Год назад
😂😂 u dont have the knowledge or skills ur a sub standard tech
@johnsherk7699
@johnsherk7699 2 года назад
Great work!
@tphvac87
@tphvac87 2 года назад
You should call it the Louisiana purchase Facebook group Copyright 😂 idk just saying. Looking heathland pal keep it up bro!
@tank_9er
@tank_9er 2 года назад
A system that you pulled a vacuum on means you fixed all leaks....shldnt require topping off each year. But what wld i know im a refrigeration tech
@dong4617
@dong4617 2 года назад
No rest for the weary.
@dc9039
@dc9039 2 года назад
Do you charge new price for the used capacitor on the first job?
@davetempeny9928
@davetempeny9928 2 года назад
John , what the hell is MO99? Never heard of it up north here
@56mountaindew
@56mountaindew 2 года назад
Hi John this question originated on your ( Old GE Condenser Change Out ) video but I didn't know if you still reply to your old videos, so I'm asking here, I have a old GE model #21TA936H1F, I wanted to check or just change the 2 capacitors, I pulled the 2 capacitors, but they are so rusty you can't read anything and the suppliers I tried said they need the uf can you get your buddy Ted Cook to find out the references for both fan and run capacitors. I don’t know if he sell parts? Thanks John, I appreciate it 96 deg today 98, 100 tomorrow
@picklerix6162
@picklerix6162 2 года назад
I thought that most companies were dropping that micro channel design? Perhaps Rheem has fixed the leaking issues but $1200 is a lot of money so the ICP sounds great.
@titom2916
@titom2916 2 года назад
Great video bro always good to leave them a quote. Hey bro what are your thoughts Leak sealers?
@biblebloopers946
@biblebloopers946 2 года назад
Looks like you lost some weight. You look really good man
@Mapdotgolf
@Mapdotgolf 2 года назад
Or just do a load calculation and see what size they need
@firstlast---
@firstlast--- 2 года назад
When my ac shuts off it rattles like an engine without oil. How do I diagnose this?
@243wayne1
@243wayne1 2 года назад
You just did. Class dismissed.
@coolramone
@coolramone 2 года назад
How do you request to get in the group?
@origtex
@origtex 2 года назад
What if I don't answer the security questions at Facebook? Just kidding.😀
@richardfossani6421
@richardfossani6421 2 года назад
Wouldn't it be better to recover 99% of the 22 and then just recharge with the replacement refrigerant. If your pulling a vacuum on a system with a leak, your just pulling in air.
@grantbrown2432
@grantbrown2432 2 года назад
Pulling all of the noncondensible out but i see what ur saying
@richardfossani6421
@richardfossani6421 2 года назад
Your actually pulling all of the noncondensibles in when your pulling a vacuum on a leaking system.
@stephwaylonwells3218
@stephwaylonwells3218 2 года назад
👍
@jayyys7143
@jayyys7143 2 года назад
I wonder how you remove the refrigerant.. 😂I’ve never seen you with a recovery machine or recovery tank 😂😂💀💀 I would just stay quiet about you “removing” refrigerant 😬
@johnisraelhvac2019
@johnisraelhvac2019 2 года назад
I have a G5 and two 30lbs recovery tanks. I wonder how you pleasure your wife? I would shut up and stop making assumptions!!
@dyershvac5884
@dyershvac5884 2 года назад
@@johnisraelhvac2019 Well said Isreal!
@patrickmcgraw5865
@patrickmcgraw5865 2 года назад
He usually fast forwards thru that part
@porky7753
@porky7753 2 года назад
LOL John, "Mexico made capacitor". Mexican capacitor sounds better. lol
@Android_Warrior
@Android_Warrior 2 года назад
"Mexico, Mexican" both are spicy!!! 😆 😅 😂 🤣
@89dhvac
@89dhvac 2 года назад
Hey John, you are looking well! Thanks for some more good content! You really do attract some morons in the comment section lol.
@wehvacwehvac5612
@wehvacwehvac5612 2 года назад
Sir, Question. Why wasn't your 460's being used correctly? You can NEVER charge a unit the correct amount of charge without using wetbulb, drybulb indoor, outdoor temperatures and pressure, your PT chart which should NEVER be left alone ever!!... Did you use the rule of thumb #3? Plus 30*f for surrounding temperatures? To help you become a better Mechanical Engineer Service, Maintenence, Installer and or a Tech. Here's something that you most definitely need to use and always remember when you're out in the field!!... Heat can be transferred in three ways: by conduction, by convection, and by radiation. Conduction is the transfer of energy from one molecule to another by direct contact. ... Convection is the movement of heat by a fluid such as water or air. ... Radiation is the transfer of heat by electromagnetic waves. I retired as a MES Mechanical Electrical Serviceman Local 250 before becoming a CEC State Inspector. I'm not trying tobe a dickhead just trying to help you, from one MES to another!!... The Widowmaker a man of God!!... "E Pluribus Unum" D'n Deus Le' Vult!!...
Далее
HVAC No Cooling Service Call WORST HELICOPTER EVER !!
22:15
No Cooling/Electrical Issue
23:27
Просмотров 4,4 тыс.
No Cooling/Compressor in Thermal Overload
16:05
Просмотров 17 тыс.
HVAC Scam failed again on 2nd opinion call
18:59
Просмотров 147 тыс.
No Cooling Call/Clogged Drain
13:51
Просмотров 2,7 тыс.
No Cooling Calls On Several AC Units!
24:52
Просмотров 5 тыс.
How to Cool Your House when Your AC Cannot Keep Up
15:11
HVAC No Cooling Call
13:10
Просмотров 17 тыс.
Commercial RTU HVAC Service Call
10:12
Просмотров 19 тыс.
Cheap Contactor Strikes Again
11:55
Просмотров 6 тыс.